Experimental determination of the E2-M1 polarizability of the strontium clock transition
Authors:
Sören Dörscher,
Joshua Klose,
Sarath Maratha Palli,
Christian Lisdat
Abstract:
To operate an optical lattice clock at a fractional uncertainty below $10^{-17}$, one must typically consider not only electric-dipole (E1) interaction between an atom and the lattice light field when characterizing the resulting lattice light shift of the clock transition but also higher-order multipole contributions, such as electric-quadrupole (E2) and magnetic-dipole (M1) interactions. However…
▽ More
To operate an optical lattice clock at a fractional uncertainty below $10^{-17}$, one must typically consider not only electric-dipole (E1) interaction between an atom and the lattice light field when characterizing the resulting lattice light shift of the clock transition but also higher-order multipole contributions, such as electric-quadrupole (E2) and magnetic-dipole (M1) interactions. However, strongly incompatible values have been reported for the E2-M1 polarizability difference of the clock states $(5s5p)\,{}^{3}\mathrm{P}_{0}$ and $(5s^2)\,{}^{1}\mathrm{S}_{0}$ of strontium [Ushijima et al., Phys. Rev. Lett. 121 263202 (2018); Porsev et al., Phys. Rev. Lett. 120, 063204 (2018)]. This largely precludes operating strontium clocks with uncertainties of few $10^{-18}$, as the resulting lattice light shift corrections deviate by up to $1 \times 10^{-17}$ from each other at typical trap depths. We have measured the E2-M1 polarizability difference using our ${}^{87}\mathrm{Sr}$ lattice clock and find a value of $Δα_{\mathrm{qm}} = -987^{+174}_{-223} \; \mathrm{μHz}$. This result is in very good agreement with the value reported by Ushijima et al.
△ Less
Submitted 26 October, 2022;
originally announced October 2022.
Submillimeter-wave cornea phantom sensing over an extended depth of field with an axicon-generated Bessel beam
Authors:
Mariangela Baggio,
Aleksi Tamminen,
Joel Lamberg,
Roman Grigorev,
Samu-Ville Pälli,
Juha Ala-Laurinaho,
Irina Nefedova,
Jean-Louis Bourges,
Sophie X. Deng,
Elliott R. Brown,
Vincent P. Wallace,
Zachary D. Taylor
Abstract:
The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the 25-degree cone angle hyperbolic-axicon lens illuminating metallic spherical targets demonstrate a monotonically decreasing, band integrated, backscatter intensity for increasing radius of curvature from 7 - 11 mm, when lens reflector and optic…
▽ More
The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the 25-degree cone angle hyperbolic-axicon lens illuminating metallic spherical targets demonstrate a monotonically decreasing, band integrated, backscatter intensity for increasing radius of curvature from 7 - 11 mm, when lens reflector and optical axis are aligned. Further, for radii >= 9.5 mm, maximum signal was obtained with a 1 mm transverse displacement between lens and reflector optical axes arising from spatial correlation between main lobe and out of phase side lobes. Thickness and permittivity parameter estimation experiments were performed on an 8 mm radius of curvature, 1 mm thick fused quartz dome over a 10 mm axial span. Extracted thickness and permittivity varied by less than ~ 25 $μ$m and 0.2 respectively after correction for superluminal velocity. Estimated water permittivity and thickness of water backed gelatin phantoms showed significantly more variation due to a time varying radius of curvature.
△ Less
Submitted 26 February, 2023; v1 submitted 25 June, 2022;
originally announced June 2022.