-
Characterization of the phonon sensor of the CRYOSEL detector with IR photons
Authors:
Hugues Lattaud,
Elsa Guy,
Julien Billard,
Jules Colas,
Maryvonne De Jésus,
Jules Gascon,
Alexandre Juillard,
Stefanos Marnieros,
Christine Oriol
Abstract:
The sensitivities of light Dark Matter (DM) particle searches with cryogenic detectors are mostly limited by large backgrounds of events that do not produce ionization signal. The CRYOSEL project develops a new technique where this background in a germanium cryogenic detector is rejected by using the signals from a Superconducting Single Electron Device (SSED) sensor designed to detect the phonons…
▽ More
The sensitivities of light Dark Matter (DM) particle searches with cryogenic detectors are mostly limited by large backgrounds of events that do not produce ionization signal. The CRYOSEL project develops a new technique where this background in a germanium cryogenic detector is rejected by using the signals from a Superconducting Single Electron Device (SSED) sensor designed to detect the phonons emitted through the Neganov-Trofimov-Luke effect by the e$^-$h$^+$ pairs as they drift in a close-by very high-field region. A tag on signals from this device should suppress the heat-only background. The measurement of the response to IR laser pulses of the first CRYOSEL prototype show the relevance of such sensor technology.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
First demonstration of 30 eVee ionization energy resolution with Ricochet germanium cryogenic bolometers
Authors:
C. Augier,
G. Baulieu,
V. Belov,
L. Bergé,
J. Billard,
G. Bres,
J. -L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chala,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
E. Cudmore,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. -B. Filippini
, et al. (55 additional authors not shown)
Abstract:
The future Ricochet experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the Ricochet collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector…
▽ More
The future Ricochet experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the Ricochet collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30~eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar heat-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector. Additionally, we discuss the implications of these results in the context of the future Ricochet experiment and its expected background mitigation performance.
△ Less
Submitted 31 May, 2023;
originally announced June 2023.
-
Results from a Prototype TES Detector for the Ricochet Experiment
Authors:
Ricochet Collaboration,
C. Augier,
G. Baulieu,
V. Belov,
L. Bergé,
J. Billard,
G. Bres,
J-. L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chala,
C. L. Chang,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
E. Cudmore,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol
, et al. (66 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of $\sim$30 g and a targeted energy threshold of 50 eV. Nine of these detectors (the "Q-Array") will be based on a novel Transition-Edge Sensor (TES) readout style, in which the TES devices are thermally coupled to the absorber using a gold wire bond. We present initial characterization of a Q-Array-style detector using a 1 gram silicon absorber, obtaining a baseline root-mean-square resolution of less than 40 eV.
△ Less
Submitted 12 January, 2024; v1 submitted 28 April, 2023;
originally announced April 2023.
-
Tagging and localisation of ionizing events using NbSi transition edge phonon sensors for Dark Matter searches
Authors:
EDELWEISS Collaboration,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
J. Colas,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. B. Filippini,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
E. Guy,
Y. **,
A. Juillard,
H. Lattaud,
S. Marnieros,
N. Martini
, et al. (14 additional authors not shown)
Abstract:
In the context of direct searches of sub-GeV Dark Matter particles with germanium detectors, the EDELWEISS collaboration has tested a new technique to tag ionizing events using NbSi transition edge athermal phonon sensors. The emission of the athermal phonons generated by the Neganov-Trofimov-Luke effect associated with the drift of electrons and holes through the detectors is used to tag ionizati…
▽ More
In the context of direct searches of sub-GeV Dark Matter particles with germanium detectors, the EDELWEISS collaboration has tested a new technique to tag ionizing events using NbSi transition edge athermal phonon sensors. The emission of the athermal phonons generated by the Neganov-Trofimov-Luke effect associated with the drift of electrons and holes through the detectors is used to tag ionization events generated in specific parts of the detector localized in front of the NbSi sensor and to reject by more than a factor 5 (at 90% C.L.) the background from heat-only events that dominates the spectrum above 3 keV. This method is able to improve by a factor 2.8 the previous limit on spin-independent interactions of 1 GeV/c2 WIMPs obtained with the same detector and data set but without this tagging technique.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor
Authors:
C. Augier,
G. Baulieu,
V. Belov,
L. Berge,
J. Billard,
G. Bres,
J. -L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. -B. Filippini,
J. A. Formaggio,
S. Fuard
, et al. (58 additional authors not shown)
Abstract:
The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW resear…
▽ More
The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment's shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $^3$He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance.
△ Less
Submitted 2 August, 2022;
originally announced August 2022.
-
EndoMapper dataset of complete calibrated endoscopy procedures
Authors:
Pablo Azagra,
Carlos Sostres,
Ángel Ferrandez,
Luis Riazuelo,
Clara Tomasini,
Oscar León Barbed,
Javier Morlana,
David Recasens,
Victor M. Batlle,
Juan J. Gómez-Rodríguez,
Richard Elvira,
Julia López,
Cristina Oriol,
Javier Civera,
Juan D. Tardós,
Ana Cristina Murillo,
Angel Lanas,
José M. M. Montiel
Abstract:
Computer-assisted systems are becoming broadly used in medicine. In endoscopy, most research focuses on the automatic detection of polyps or other pathologies, but localization and navigation of the endoscope are completely performed manually by physicians. To broaden this research and bring spatial Artificial Intelligence to endoscopies, data from complete procedures is needed. This paper introdu…
▽ More
Computer-assisted systems are becoming broadly used in medicine. In endoscopy, most research focuses on the automatic detection of polyps or other pathologies, but localization and navigation of the endoscope are completely performed manually by physicians. To broaden this research and bring spatial Artificial Intelligence to endoscopies, data from complete procedures is needed. This paper introduces the Endomapper dataset, the first collection of complete endoscopy sequences acquired during regular medical practice, making secondary use of medical data. Its main purpose is to facilitate the development and evaluation of Visual Simultaneous Localization and Map** (VSLAM) methods in real endoscopy data. The dataset contains more than 24 hours of video. It is the first endoscopic dataset that includes endoscope calibration as well as the original calibration videos. Meta-data and annotations associated with the dataset vary from the anatomical landmarks, procedure labeling, segmentations, reconstructions, simulated sequences with ground truth and same patient procedures. The software used in this paper is publicly available.
△ Less
Submitted 10 October, 2023; v1 submitted 29 April, 2022;
originally announced April 2022.
-
Coherent elastic neutrino-nucleus scattering: Terrestrial and astrophysical applications
Authors:
M. Abdullah,
H. Abele,
D. Akimov,
G. Angloher,
D. Aristizabal-Sierra,
C. Augier,
A. B. Balantekin,
L. Balogh,
P. S. Barbeau,
L. Baudis,
A. L. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
A. Bento,
L. Berge,
I. A. Bernardi,
J. Billard,
A. Bolozdynya,
A. Bonhomme,
G. Bres,
J-. L. Bret,
A. Broniatowski,
A. Brossard,
C. Buck
, et al. (250 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion source with CsI detectors, followed up the detection of CE$ν$NS using an Ar target. The detection of CE$ν$NS has spawned a flurry of activities in high-energy physics, inspiring new constraints on beyond the Standard Model (BSM) physics, and new experimental methods. The CE$ν$NS process has important implications for not only high-energy physics, but also astrophysics, nuclear physics, and beyond. This whitepaper discusses the scientific importance of CE$ν$NS, highlighting how present experiments such as COHERENT are informing theory, and also how future experiments will provide a wealth of information across the aforementioned fields of physics.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Search for sub-GeV Dark Matter via Migdal effect with an EDELWEISS germanium detector with NbSi TES sensors
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Caze,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. B. Filippini,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
E. Guy,
Y. **,
A. Juillard,
M. Kleifges,
H. Lattaud,
S. Marnieros
, et al. (15 additional authors not shown)
Abstract:
The EDELWEISS collaboration reports on the search for Dark Matter (DM) particle interactions via Migdal effect with masses between $32$ MeV$\cdot$c$^{-2}$ to $2$ GeV$\cdot$c$^{-2}$ using a $200$ g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a Transition…
▽ More
The EDELWEISS collaboration reports on the search for Dark Matter (DM) particle interactions via Migdal effect with masses between $32$ MeV$\cdot$c$^{-2}$ to $2$ GeV$\cdot$c$^{-2}$ using a $200$ g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a Transition Edge Sensor made of a NbSi thin film. The detector was biased at $66$ V in order to benefit from the Neganov-Trofimov-Luke amplification and resulting in a resolution on the energy of electron recoils of $4.46$ eV$_{ee}$ (RMS) and an analysis threshold of $30$ eV$_{ee}$. The sensitivity is limited by a dominant background not associated to charge creation in the detector. The search constrains a new region of parameter space for cross-sections down to $10^{-29}$ cm$^2$ and masses between $32$ and $100$ MeV$\cdot$c$^{-2}$. The achieved low threshold with the NbSi sensor shows the relevance of its use for athermal-phonon sensitive devices for low-mass DM searches.
△ Less
Submitted 3 October, 2022; v1 submitted 8 March, 2022;
originally announced March 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
High impedance TES bolometers for EDELWEISS
Authors:
S. Marnieros,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. -B. Fillipini,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
H. Lattaud,
D. Misiak
, et al. (13 additional authors not shown)
Abstract:
The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge bolometers equipped with high impedance thermistors based on a NbxSi1-x TES alloy. High aspect ratio spiral designs allow the TES impedance to match with JFET or HEMT…
▽ More
The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge bolometers equipped with high impedance thermistors based on a NbxSi1-x TES alloy. High aspect ratio spiral designs allow the TES impedance to match with JFET or HEMT front-end amplifiers. We detail the behavior of the superconducting transition properties of these sensors and the detector optimization in terms of sensitivity to out-of-equilibrium phonons. We report preliminary results of a 200 g Ge detector that was calibrated using 71Ge activation by neutrons at the LSM underground laboratory.
△ Less
Submitted 5 January, 2022;
originally announced January 2022.
-
Phonon and charge signals from IR and X excitation in the SELENDIS Ge cryogenic detector
Authors:
H. Lattaud,
Q. Arnaud,
J. Billard,
J. Colas,
L. Dumoulin,
M. De Jésus,
A. Juillard,
J. Gascon,
S. Marnieros,
C. Oriol
Abstract:
The aim of the SELENDIS project within the EDELWEISS collaboration is to observe single $e^- h^+$ pairs in lightweight (3.3 g) cryogenic germanium bolometers with charge and phonon readout at biases up to $\sim 100$ V. These devices are ideal to characterize in detail the mechanism of charge creation and collection in cryogenic germanium detectors. Electron-hole pairs are produced in the bulk of t…
▽ More
The aim of the SELENDIS project within the EDELWEISS collaboration is to observe single $e^- h^+$ pairs in lightweight (3.3 g) cryogenic germanium bolometers with charge and phonon readout at biases up to $\sim 100$ V. These devices are ideal to characterize in detail the mechanism of charge creation and collection in cryogenic germanium detectors. Electron-hole pairs are produced in the bulk of the detector either by the injection of pulsed IR laser or by neutron activation of germanium inducing the K, L and M lines from $^{71}$Ge electron capture decays. Low-energy laser pulses are also used to probe the single $e^- h^+$ pair sensitivity of Ge bolometers. Preliminary results are used to compare these two modes of charge creation, an important step toward a detailed characterization of Ge bolometers for their use in sub-MeV Dark Matter (DM) searches.
△ Less
Submitted 22 December, 2021;
originally announced December 2021.
-
Low-mass Dark Matter searches with EDELWEISS
Authors:
J. Gascon,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoit,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. -B. Filippini,
D. Filosofov,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
H. Lattaud,
S. Marnieros,
D. Misiak
, et al. (13 additional authors not shown)
Abstract:
The EDELWEISS collaboration searches for light Dark Matter (DM) particles using germanium detectors equipped with a charge and phonon signal readout. Using the Neganov-Trofimov-Luke effect, an rms resolution of 0.53 electron-hole pair was obtained on a massive (33.4 g) Ge detector operated underground at the Laboratoire Souterrain de Modane. This record sensitivity made possible a search for Dark…
▽ More
The EDELWEISS collaboration searches for light Dark Matter (DM) particles using germanium detectors equipped with a charge and phonon signal readout. Using the Neganov-Trofimov-Luke effect, an rms resolution of 0.53 electron-hole pair was obtained on a massive (33.4 g) Ge detector operated underground at the Laboratoire Souterrain de Modane. This record sensitivity made possible a search for Dark Photon DM down to 1 eV/c2 and to DM-electron interactions below 1 MeV/c2. This demonstrates for the first time the high relevance of cryogenic Ge detectors in searches at low thresholds and is an important step of the development of Ge detectors with improved performance in the context of the EDELWEISS-SubGeV program.
△ Less
Submitted 10 March, 2022; v1 submitted 10 December, 2021;
originally announced December 2021.
-
Optimization and performance of the CryoCube detector for the future RICOCHET low-energy neutrino experiment
Authors:
T. Salagnac,
J. Billard,
J. Colas,
D. Chaize,
M. De Jesus,
L. Dumoulin,
J. -B. Filippini,
J. Gascon,
A. Juillard,
H. Lattaud,
S. Marnieros,
D. Misiak,
C. Oriol,
L. Vagneron,
the RICOCHET collaboration
Abstract:
The RICOCHET reactor neutrino observatory is planned to be installed at Institut Laue-Langevin starting in mid-2022. The scientific goal of the RICOCHET collaboration is to perform a low-energy and percentage-precision CENNS measurement in order to explore exotic physics scenarios beyond the standard model. To that end, RICOCHET will host two cryogenic detector arrays : the CryoCube (Ge target) an…
▽ More
The RICOCHET reactor neutrino observatory is planned to be installed at Institut Laue-Langevin starting in mid-2022. The scientific goal of the RICOCHET collaboration is to perform a low-energy and percentage-precision CENNS measurement in order to explore exotic physics scenarios beyond the standard model. To that end, RICOCHET will host two cryogenic detector arrays : the CryoCube (Ge target) and the Q-ARRAY (Zn target), both with unprecedented sensitivity to O(10)eV nuclear recoils. The CryoCube will be composed of 27 Ge crystals of 38g instrumented with NTD-Ge thermal sensor as well as aluminum electrodes operated at 10mK in order to measure both the ionization and the heat energies arising from a particle interaction. To be a competitive CENNS detector, the CryoCube array is designed with the following specifications : a low energy threshold ($\sim 50$eV), the ability to identify and reject with a high efficiency the overwhelming electromagnetic backgrounds (gamma, betas, X-rays) and a sufficient payload ($\sim 1$kg). After a brief introduction of the future RICOCHET experiment and its CryoCube, the current works and first performance results on the optimization of the heat channel and the electrode designs will be presented. We conclude with a preliminary estimation of the CryoCube sensitivity to the CENNS signal within RICOCHET.
△ Less
Submitted 24 November, 2021;
originally announced November 2021.
-
Ricochet Progress and Status
Authors:
Ricochet Collaboration,
G. Beaulieu,
V. Belov,
L. Berge,
J. Billard,
G. Bres,
J-. L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. B. Filippini,
J. A. Formaggio,
S. Fuard
, et al. (55 additional authors not shown)
Abstract:
We present an overview of recent progress towards the Ricochet coherent elastic neutrino nucleus scattering CE$ν$NS experiment. The ILL research reactor in Grenoble, France has been selected as the experiment site, after in situ studies of vibration and particle backgrounds. We present background rate estimates specific to that site, along with descriptions of the planned CryoCube and Q-Array dete…
▽ More
We present an overview of recent progress towards the Ricochet coherent elastic neutrino nucleus scattering CE$ν$NS experiment. The ILL research reactor in Grenoble, France has been selected as the experiment site, after in situ studies of vibration and particle backgrounds. We present background rate estimates specific to that site, along with descriptions of the planned CryoCube and Q-Array detector payloads.
△ Less
Submitted 12 November, 2021;
originally announced November 2021.
-
QUBIC IV: Performance of TES Bolometers and Readout Electronics
Authors:
M. Piat,
G. Stankowiak,
E. S. Battistelli,
P. de Bernardis,
G. D Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
T. D. Hoang,
S. Marnieros,
S. Masi,
A. Mennella,
L. Mousset,
C. O Sullivan,
D. Prele,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi
, et al. (104 additional authors not shown)
Abstract:
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are…
▽ More
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are controlled and amplified by an SiGe application specific integrated circuit at 40 K. We report the performance of this readout chain and the characterization of the TES. The readout system has been functionally tested and characterized in the lab and in QUBIC. The low noise amplifier demonstrated a white noise level of 0.3 nV.Hz^-0.5. Characterizations of the QUBIC detectors and readout electronics includes the measurement of I-V curves, time constant and the noise equivalent power. The QUBIC TES bolometer array has approximately 80% detectors within operational parameters. It demonstrated a thermal decoupling compatible with a phonon noise of about 5.10^-17 W.Hz^-0.5 at 410 mK critical temperature. While still limited by microphonics from the pulse tubes and noise aliasing from readout system, the instrument noise equivalent power is about 2.10^-16 W.Hz^-0.5, enough for the demonstration of bolometric interferometry.
△ Less
Submitted 20 October, 2021; v1 submitted 17 January, 2021;
originally announced January 2021.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
QUBIC I: Overview and ScienceProgram
Authors:
J. -Ch. Hamilton,
L. Mousset,
E. S. Battistelli,
M. -A. Bigot-Sazy,
P. Chanial,
R. Charlassier,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
M. M. Gamboa Lerena,
L. Grandsire,
S. Lau,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
M. Piat,
G. Riccardi,
C. Scóccola,
M. Stolpovskiy,
A. Tartari,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade
, et al. (105 additional authors not shown)
Abstract:
The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical fo…
▽ More
The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.
△ Less
Submitted 26 August, 2021; v1 submitted 4 November, 2020;
originally announced November 2020.
-
QUBIC II: Spectro-Polarimetry with Bolometric Interferometry
Authors:
L. Mousset,
M. M. Gamboa Lerena,
E. S. Battistelli,
P. de Bernardis,
P. Chanial,
G. D'Alessandro,
G. Dashyan,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
F. Incardona,
S. Landau,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
M. Piat,
G. Ricciardi,
C. G. Scóccola,
M. Stolpovskiy,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (106 additional authors not shown)
Abstract:
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foreg…
▽ More
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust map** and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.
△ Less
Submitted 28 March, 2022; v1 submitted 28 October, 2020;
originally announced October 2020.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
QUBIC VII: The feedhorn-switch system of the technological demonstrator
Authors:
F. Cavaliere,
A. Mennella,
M. Zannoni,
P. Battaglia,
E. S. Battistelli,
D. Burke,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
C. Franceschet,
L. Grandsire,
J. -Ch. Hamilton,
B. Maffei,
E. Manzan,
S. Marnieros,
S. Masi,
C. O'Sullivan,
A. Passerini,
F. Pezzotta,
M. Piat,
A. Tartari,
S. A. Torchinsky,
D. Viganò,
F. Voisin,
P. Ade
, et al. (106 additional authors not shown)
Abstract:
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration…
▽ More
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.
△ Less
Submitted 1 April, 2022; v1 submitted 28 August, 2020;
originally announced August 2020.
-
QUBIC VI: cryogenic half wave plate rotator, design and performances
Authors:
G. D'Alessandro,
L. Mele,
F. Columbro,
G. Amico,
E. S. Battistelli,
P. de Bernardis,
A. Coppolecchia,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
L. Lamagna,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
G. Pisano,
G. Presta,
A. Tartari,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade
, et al. (104 additional authors not shown)
Abstract:
Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used t…
▽ More
Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).
△ Less
Submitted 19 November, 2020; v1 submitted 24 August, 2020;
originally announced August 2020.
-
QUBIC V: Cryogenic system design and performance
Authors:
S. Masi,
E. S. Battistelli,
P. de Bernardis,
C. Chapron,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
L. Mele,
A. May,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
L. Piccirillo,
G. Presta,
A. Schillaci,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (104 additional authors not shown)
Abstract:
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the map** speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interfe…
▽ More
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the map** speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.
△ Less
Submitted 25 August, 2021; v1 submitted 24 August, 2020;
originally announced August 2020.
-
QUBIC VIII: Optical design and performance
Authors:
C. O'Sullivan,
M. De Petris,
G. Amico,
E. S. Battistelli,
D. Burke,
D. Buzi,
C. Chapron,
L. Conversi,
G. D'Alessandro,
P. de Bernardis,
M. De Leo,
D. Gayer,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
S. Masi,
A. Mattei,
A. Mennella,
L. Mousset,
J. D. Murphy,
A. Pelosi,
M. Perciballi,
M. Piat,
S. Scully,
A. Tartari
, et al. (104 additional authors not shown)
Abstract:
The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or p…
▽ More
The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or planned experiments using the novel technique of bolometric interferometry. This technique takes advantage of the sensitivity of an imager and the systematic error control of an interferometer. A cold reflective optical combiner superimposes there-emitted beams from 400 aperture feedhorns on two focal planes. A shielding system composedof a fixed groundshield, and a forebaffle that moves with the instrument, limits the impact of local contaminants. The modelling, design, manufacturing and preliminary measurements of the optical components are described in this paper.
△ Less
Submitted 25 August, 2021; v1 submitted 23 August, 2020;
originally announced August 2020.
-
QUBIC III: Laboratory Characterization
Authors:
S. A. Torchinsky,
J. -Ch. Hamilton,
M. Piat,
E. S. Battistelli,
C. Chapron,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
M. M. Gamboa Lerena,
M. González,
L. Grandsire,
S. Masi,
S. Marnieros,
A. Mennella,
L. Mousset,
J. D. Murphy,
D. Prêle,
G. Stankowiak,
C. O'Sullivan,
A. Tartari,
J. -P. Thermeau,
F. Voisin,
M. Zannoni,
P. Ade,
J. G. Alberro
, et al. (103 additional authors not shown)
Abstract:
A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam,…
▽ More
A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.
△ Less
Submitted 15 March, 2022; v1 submitted 23 August, 2020;
originally announced August 2020.
-
First germanium-based constraints on sub-MeV Dark Matter with the EDELWEISS experiment
Authors:
EDELWEISS Collaboration,
Q. Arnaud,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
E. Elkhoury,
J. -B. Fillipini,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
Y. **,
A. Juillard,
M. Kleifges,
H. Lattaud
, et al. (17 additional authors not shown)
Abstract:
The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting…
▽ More
The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting with electrons, as well as on dark photons down to 1 eV/c$^2$. These are competitive with other searches. In particular, new limits are set on the kinetic mixing of dark photon DM in a so far unconstrained parameter space region in the 6 to 9 eV/c$^2$ mass range. These results demonstrate the high relevance of cryogenic Ge detectors for the search of DM interactions producing eV-scale electron signals.
△ Less
Submitted 10 March, 2022; v1 submitted 2 March, 2020;
originally announced March 2020.
-
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Authors:
E. S. Battistelli,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi,
D. Auguste,
J. Aumont,
S. Azzoni,
S. Banfi,
P. Battaglia,
A. Baù,
B. Bèlier,
D. Bennett,
L. Bergè,
J. -Ph. Bernard,
M. Bersanelli,
M. -A. Bigot-Sazy,
N. Bleurvacq,
J. Bonaparte,
J. Bonis,
A. Bottani,
E. Bunn,
D. Burke,
D. Buzi
, et al. (114 additional authors not shown)
Abstract:
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addr…
▽ More
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.
△ Less
Submitted 28 January, 2020;
originally announced January 2020.
-
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
Authors:
M. Piat,
B. Bélier,
L. Bergé,
N. Bleurvacq,
C. Chapron,
S. Dheilly,
L. Dumoulin,
M. González,
L. Grandsire,
J. -Ch. Hamilton,
S. Henrot-Versillé,
D. T. Hoang,
S. Marnieros,
W. Marty,
L. Montier,
E. Olivieri,
C. Oriol,
C. Perbost,
D. Prêle,
D. Rambaud,
M. Salatino,
G. Stankowiak,
J. -P. Thermeau,
S. Torchinsky,
F. Voisin
, et al. (113 additional authors not shown)
Abstract:
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detec…
▽ More
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.
△ Less
Submitted 9 December, 2019; v1 submitted 27 November, 2019;
originally announced November 2019.
-
The CROSS Experiment: Rejecting Surface Events by PSD Induced by Superconducting Films
Authors:
H. Khalife,
L. Bergé,
M. Chapellier,
L. Dumoulin,
A. Giuliani,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi,
C. Nones,
V. Novati,
E. Olivieri,
Ch. Oriol,
D. V. Poda,
Th. Redon,
A. S. Zolotarova
Abstract:
Neutrinoless double beta ($0νββ$) decay is a hypothetical rare nuclear transition ($T_{1/2}>10^{26}$ y). Its observation would provide an important insight about the nature of neutrinos (Dirac or Majorana particle) demonstrating that the lepton number is not conserved. This decay can be investigated with bolometers embedding the double beta decay isotope ($^{76}$Ge, $^{82}$Se, $^{100}$Mo,…
▽ More
Neutrinoless double beta ($0νββ$) decay is a hypothetical rare nuclear transition ($T_{1/2}>10^{26}$ y). Its observation would provide an important insight about the nature of neutrinos (Dirac or Majorana particle) demonstrating that the lepton number is not conserved. This decay can be investigated with bolometers embedding the double beta decay isotope ($^{76}$Ge, $^{82}$Se, $^{100}$Mo, $^{116}$Cd, $^{130}$Te...), which perform as low temperature calorimeters (10 mK) detecting particle interactions via a small temperature rise read out by a dedicated thermometer. CROSS (Cryogenic Rare-event Observatory with Surface Sensitivity) aims at the development of bolometric detectors (Li$_{2}$MoO$_{4}$ and TeO$_{2}$) capable of discriminating surface $α$ and $β$ interactions by exploiting superconducting properties of Al film deposited on the crystal surface. We report in this paper the results of tests on prototypes performed at CSNSM (Orsay, France) that showed the capability of a-few-$μ$m-thick superconducting Al film deposited on crystal surface to discriminate surface $α$ from bulk events, thus providing the detector with the required surface sensitivity capability. The CROSS technology would further improve the background suppression and simplify the detector construction with a view to future competitive double beta decay searches.
△ Less
Submitted 11 February, 2020; v1 submitted 26 July, 2019;
originally announced July 2019.
-
The $0\nu2β$-decay CROSS experiment: preliminary results and prospects
Authors:
I. C. Bandac,
A. S. Barabash,
L. Bergé,
M. Brière,
Ch. Bourgeois,
P. Carniti,
M. Chapellier,
M. de Combarieu,
I. Dafinei,
F. A. Danevich,
N. Dosme,
D. Doullet,
L. Dumoulin,
F. Ferri,
A. Giuliani,
C. Gotti,
Ph. Gras,
E. Guerard,
A. Ianni,
H. Khalife,
S. I. Konovalov,
E. Legay,
P. Loaiza,
P. de Marcillac,
S. Marnieros
, et al. (12 additional authors not shown)
Abstract:
Neutrinoless double-beta decay is a key process in particle physics. Its experimental investigation is the only viable method that can establish the Majorana nature of neutrinos, providing at the same time a sensitive inclusive test of lepton number violation. CROSS (Cryogenic Rare-event Observatory with Surface Sensitivity) aims at develo** and testing a new bolometric technology to be applied…
▽ More
Neutrinoless double-beta decay is a key process in particle physics. Its experimental investigation is the only viable method that can establish the Majorana nature of neutrinos, providing at the same time a sensitive inclusive test of lepton number violation. CROSS (Cryogenic Rare-event Observatory with Surface Sensitivity) aims at develo** and testing a new bolometric technology to be applied to future large-scale experiments searching for neutrinoless double-beta decay of the promising nuclei $^{100}$Mo and $^{130}$Te. The limiting factor in large-scale bolometric searches for this rare process is the background induced by surface radioactive contamination, as shown by the results of the CUORE experiment. The basic concept of CROSS consists of rejecting this challenging background component by pulse-shape discrimination, assisted by a proper coating of the faces of the crystal containing the isotope of interest and serving as energy absorber of the bolometric detector. In this paper, we demonstrate that ultra-pure superconductive Al films deposited on the crystal surfaces act successfully as pulse-shape modifiers, both with fast and slow phonon sensors. Rejection factors higher than 99.9% of $α$ surface radioactivity have been demonstrated in a series of prototypes based on crystals of Li$_2$MoO$_4$ and TeO$_2$. We have also shown that point-like energy depositions can be identified up to a distance of $\sim 1$ mm from the coated surface. The present program envisions an intermediate experiment to be installed underground in the Canfranc laboratory (Spain) in a CROSS-dedicated facility. This experiment, comprising $\sim 3\times 10^{25}$ nuclei of $^{100}$Mo, will be a general test of the CROSS technology as well as a worldwide competitive search for neutrinoless double-beta decay, with sensitivity to the effective Majorana mass down to 70 meV in the most favorable conditions.
△ Less
Submitted 16 September, 2019; v1 submitted 24 June, 2019;
originally announced June 2019.
-
Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
A. Benoit,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapelier,
F. Charlieux,
D. Ducimetière,
L. Dumoulin,
K. Eitel,
D. Filosofov,
J. Gascon,
A. Giuliani,
M. Gros,
M. De Jésus,
Y. **,
A. Juillard,
M. Kleifges,
R. Maisonobe,
S. Marnieros,
D. Misiak
, et al. (16 additional authors not shown)
Abstract:
The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding…
▽ More
The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding and the high-background environment, the first sub-GeV spin-independent dark matter limit based on a germanium target has been achieved. The experiment provides the most stringent, nuclear recoil based, above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The experiment also provides the most stringent limits on spin-dependent interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the dark matter search results were studied in the context of Strongly Interacting Massive Particles, taking into account Earth-shielding effects, for which new regions of the available parameter space have been excluded. Finally, the dark matter search has also been extended to interactions via the Migdal effect, resulting for the first time in the exclusion of particles with masses between 45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from $10^{-29}$ to $10^{-26}$~cm$^2$.
△ Less
Submitted 2 April, 2019; v1 submitted 11 January, 2019;
originally announced January 2019.