Prototype study of $0.1\%\,X_0$ and $\mathrm{MHz/cm^2}$ tolerant Resistive Plate Chamber with Diamond-Like Carbon electrodes
Authors:
Kei Ieki,
Weiyuan Li,
Atsuhiko Ochi,
Rina Onda,
Wataru Ootani,
Atsushi Oya,
Masato Takahashi,
Kensuke Yamamoto
Abstract:
A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{μm}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use of thin films coated with DLC enables an ultra-low mass design of $< 0.1\%\,X_0$ with up to a four-layer configuration. At the same time, 42% MIP efficiency, and…
▽ More
A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{μm}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use of thin films coated with DLC enables an ultra-low mass design of $< 0.1\%\,X_0$ with up to a four-layer configuration. At the same time, 42% MIP efficiency, and 180 ps timing resolution per layer were achieved in a measurement performed under a $1\,\mathrm{MHz/cm^2}$ non-MIP charged particle beam. In addition, we propose a further improved design for a $20\,\mathrm{cm}$-scale detector that can achieve 90% four-layer efficiency in an even higher $4\,\mathrm{MHz/cm^2}$ beam. In this paper, we describe the detector design, present the results of performance measurements, and characterize the rate capability of the DLC-based RPCs with a performance projection for an improved design.
△ Less
Submitted 24 January, 2024;
originally announced January 2024.
-
A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment
Authors:
MEG II collaboration,
K. Afanaciev,
A. M. Baldini,
S. Ban,
V. Baranov,
H. Benmansour,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
A. Corvaglia,
F. Cuna,
G. Dal Maso,
A. De Bari,
M. De Gerone,
L. Ferrari Barusso,
M. Francesconi,
L. Galli,
G. Gallucci,
F. Gatti,
L. Gerritzen,
F. Grancagnolo
, et al. (57 additional authors not shown)
Abstract:
The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtain…
▽ More
The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.
△ Less
Submitted 7 January, 2024; v1 submitted 19 October, 2023;
originally announced October 2023.
-
Operation and performance of MEG II detector
Authors:
MEG II Collaboration,
K. Afanaciev,
A. M. Baldini,
S. Ban,
V. Baranov,
H. Benmansour,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
A. Corvaglia,
F. Cuna,
G. Dal Maso,
A. De Bari,
M. De Gerone,
L. Ferrari Barusso,
M. Francesconi,
L. Galli,
G. Gallucci,
F. Gatti,
L. Gerritzen,
F. Grancagnolo
, et al. (60 additional authors not shown)
Abstract:
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation…
▽ More
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.
△ Less
Submitted 8 January, 2024; v1 submitted 18 October, 2023;
originally announced October 2023.
-
Development of ultra-low mass and high-rate capable RPC based on Diamond-Like Carbon electrodes for MEG II experiment
Authors:
Kensuke Yamamoto,
Sei Ban,
Kei Ieki,
Atsuhiko Ochi,
Rina Onda,
Wataru Ootani,
Atsushi Oya,
Masato Takahashi
Abstract:
A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector is required to have extremely low mass and a high rate capability. A single-layer prototype detector with 2 cm $\times$ 2 cm size was constructed and evaluated…
▽ More
A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector is required to have extremely low mass and a high rate capability. A single-layer prototype detector with 2 cm $\times$ 2 cm size was constructed and evaluated to have a high rate capability of 1 MHz/cm$^2$ low-momentum muons. For a higher rate capability and scalability of the detector size, the electrodes to supply high voltage were segmented at a 1 cm pitch by implementing a conductive pattern on diamond-like carbon. Using the new electrodes, a four-layer prototype detector was constructed and evaluated to have a 46% detection efficiency with only a single layer active at a rate of $\cal O$(10 kHz). The result with the new electrodes is promising to achieve the required detection efficiency of 90% at a rate of 4 MHz/cm$^2$ with all the layers active.
△ Less
Submitted 26 February, 2023; v1 submitted 22 November, 2022;
originally announced November 2022.
-
Study on degradation of VUV-sensitivity of MPPC for liquid xenon scintillation detector by radiation damage in MEG II experiment
Authors:
K. Ieki,
T. Iwamoto,
S. Kobayashi,
Toshinori Mori,
S. Ogawa,
R. Onda,
W. Ootani,
K. Shimada,
K. Toyoda
Abstract:
In the MEG II experiment, the liquid xenon gamma-ray detector uses Multi-Pixel Photon Counters (MPPC) which are sensitive to vacuum ultraviolet (VUV) light under a high-intensity muon beam environment. In the commissioning phase of the detector with the beam, a significant degradation in the photon detection efficiency (PDE) for VUV light was found, while the degradation in the PDE for visible lig…
▽ More
In the MEG II experiment, the liquid xenon gamma-ray detector uses Multi-Pixel Photon Counters (MPPC) which are sensitive to vacuum ultraviolet (VUV) light under a high-intensity muon beam environment. In the commissioning phase of the detector with the beam, a significant degradation in the photon detection efficiency (PDE) for VUV light was found, while the degradation in the PDE for visible light was much less significant. This implies that the radiation damage is localized to the surface of the MPPC where incoming VUV photons create electron-hole pairs. It was also found that the PDE can recover to the original level by thermal annealing.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
Development of high-rate capable and ultra-low mass Resistive Plate Chamber with Diamond-Like Carbon
Authors:
Atsushi Oya,
Kei Ieki,
Atsuhiko Ochi,
Rina Onda,
Wataru Ootani,
Kensuke Yamamoto
Abstract:
A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this detector is required to be high-rate capable and ultra-low mass. Using a prototype detector with 2 cm $\times$ 2 cm size and 0.1 % $X_0$ material budget, perfor…
▽ More
A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this detector is required to be high-rate capable and ultra-low mass. Using a prototype detector with 2 cm $\times$ 2 cm size and 0.1 % $X_0$ material budget, performance studies were conducted for MIP detection efficiency, timing resolution and high rate capability in low-momentum muon beam. In this paper, the measured performance is presented including the result with low-momentum muon beam at rate up to 1 $\mathrm{MHz/cm^2}$. Based on the result, the expected performance of the full-scale detector in the MEG~II experiment is also discussed.
△ Less
Submitted 28 September, 2021;
originally announced September 2021.
-
Fast Estimation Method for the Stability of Ensemble Feature Selectors
Authors:
Rina Onda,
Zhengyan Gao,
Masaaki Kotera,
Kenta Oono
Abstract:
It is preferred that feature selectors be \textit{stable} for better interpretabity and robust prediction. Ensembling is known to be effective for improving the stability of feature selectors. Since ensembling is time-consuming, it is desirable to reduce the computational cost to estimate the stability of the ensemble feature selectors. We propose a simulator of a feature selector, and apply it to…
▽ More
It is preferred that feature selectors be \textit{stable} for better interpretabity and robust prediction. Ensembling is known to be effective for improving the stability of feature selectors. Since ensembling is time-consuming, it is desirable to reduce the computational cost to estimate the stability of the ensemble feature selectors. We propose a simulator of a feature selector, and apply it to a fast estimation of the stability of ensemble feature selectors. To the best of our knowledge, this is the first study that estimates the stability of ensemble feature selectors and reduces the computation time theoretically and empirically.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment
Authors:
The MEG II Collaboration,
Alessandro M. Baldini,
Vladimir Baranov,
Michele Biasotti,
Gianluigi Boca,
Paolo W. Cattaneo,
Gianluca Cavoto,
Fabrizio Cei,
Marco Chiappini,
Gianluigi Chiarello,
Alessandro Corvaglia,
Federica Cuna,
Giovanni dal Maso,
Antonio de Bari,
Matteo De Gerone,
Marco Francesconi,
Luca Galli,
Giovanni Gallucci,
Flavio Gatti,
Francesco Grancagnolo,
Marco Grassi,
Dmitry N. Grigoriev,
Malte Hildebrandt,
Kei Ieki,
Fedor Ignatov
, et al. (45 additional authors not shown)
Abstract:
The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$)…
▽ More
The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while kee** the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.
△ Less
Submitted 1 September, 2021; v1 submitted 22 July, 2021;
originally announced July 2021.
-
Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment
Authors:
A. M. Baldini,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
A. Corvaglia,
A. de Bari,
M. De Gerone,
M. Francesconi,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
D. N. Grigoriev,
M. Hildebrandt,
Z. Hodge,
K. Ieki,
F. Ignatov,
R. Iwai,
T. Iwamoto
, et al. (46 additional authors not shown)
Abstract:
We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $μ^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to γγ$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for l…
▽ More
We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $μ^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to γγ$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20--40 MeV/c$^2$, down to $\mathcal{O}(10^{-11})$ at 90\% confidence level.
△ Less
Submitted 8 November, 2020; v1 submitted 1 May, 2020;
originally announced May 2020.
-
Large-Area MPPC with Enhanced VUV Sensitivity for Liquid Xenon Scintillation Detector
Authors:
K. Ieki,
T. Iwamoto,
D. Kaneko,
S. Kobayashi,
N. Matsuzawa,
T. Mori,
S. Ogawa,
R. Onda,
W. Ootani,
R. Sawada,
K. Sato,
R. Yamada
Abstract:
A large-area Multi-Pixel Photon Counter (MPPC) sensitive to vacuum ultra violet (VUV) light has been developed for the liquid xenon (LXe) scintillation detector of the MEG II experiment. The LXe detector is designed to detect the 52.8\,MeV photon from the lepton flavour violating decay $μ^+ \to \mathrm{e}^+ γ$ and is based on $900\,\ell$ LXe with a highly granular scintillation readout by 4092 VUV…
▽ More
A large-area Multi-Pixel Photon Counter (MPPC) sensitive to vacuum ultra violet (VUV) light has been developed for the liquid xenon (LXe) scintillation detector of the MEG II experiment. The LXe detector is designed to detect the 52.8\,MeV photon from the lepton flavour violating decay $μ^+ \to \mathrm{e}^+ γ$ and is based on $900\,\ell$ LXe with a highly granular scintillation readout by 4092 VUV-MPPCs with an active area of $139\,\mathrm{mm}^2$ each, totalling $0.57\,\mathrm{m}^2$. The VUV-MPPC shows an excellent performance in LXe, which includes a high photon detection efficiency (PDE) up to 21\% for the LXe scintillation light in the VUV range, a high gain, a low probability of the optical cross-talk and the after-pulsing, a low dark count rate and a good single photoelectron resolution. The large active area of the VUV-MPPC is formed by connecting four independent small VUV-MPPC chips in series to avoid the increase of the sensor capacitance and thus, to have a short pulse-decay-time, which is crucial for high rate experiments. Performance tests of 4180 VUV-MPPCs produced for the LXe detector were also carried out at room temperature prior to the installation to the detector and all of them with only a few exceptions were found to work properly. The design and performance of the VUV-MPPC are described in detail as well as the results from the performance tests at room temperature.
△ Less
Submitted 5 February, 2019; v1 submitted 23 September, 2018;
originally announced September 2018.