On The Importance of Fundamental Computational Fluid Dynamics Towards a Robust and Reliable Model of Left Atrial Flows: Is There More Than Meets the Eye?
Authors:
Ehsan Khalili,
C'ecile Daversin-Catty,
Andy L. Olivares,
Jordi Mill,
Oscar Camara,
Kristian Valen-Sendstad
Abstract:
Computational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, e.g., revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modelling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) ve…
▽ More
Computational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, e.g., revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modelling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) versus normal-resolution/accuracy (NR) solution strategies, respectively. CFD simulations on 12 patient-specific left atrial geometries, obtained from computed tomography scans, were performed by using a second-order accurate and space/time centered solver. The convergence studies showed an average variability of around 30\% and 55\% for time averaged wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), and endothelial cell activation potential (ECAP), even between intermediate spatial and temporal resolutions, in the left atrium (LA) and left atrial appendage (LAA), respectively. The comparison between HR and NR simulations showed good correlation in the LA for WSS, RRT, and ECAP (R^2 > 0.9), but not for OSI (R^2 = 0.63). However, there were poor correlations in the LAA especially for OSI, RRT, and ECAP (R^2 = 0.55, 0.63, and 0.61, respectively), except for WSS (R^2 = 0.81). The errors are comparable to differences previously reported with disease correlations. To robustly predict atrial hemodynamics and stresses, numerical resolutions of 10M elements and 10k time-steps per cycle seem necessary (i.e., one order of magnitude higher than normally used in both space and time). In conclusion, attention to fundamental numerical aspects is essential towards establishing a plausible, robust, and reliable model of LA flows.
△ Less
Submitted 3 February, 2023;
originally announced February 2023.
In-silico analysis of the influence of pulmonary vein configuration on left atrial haemodynamics and thrombus formation in a large cohort
Authors:
Jordi Mill,
Josquin Harrison,
Benoit Legghe,
Andy L. Olivares,
Xabier Morales,
Jerome Noailly,
Xavier Iriart,
Hubert Cochet,
Maxime Sermesant,
Oscar Camara
Abstract:
Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99\% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Mor…
▽ More
Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99\% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Moreover, the impact of structures such as the pulmonary veins (PVs) on LA haemodynamics has not been thoroughly studied due to the difficulties of acquiring appropriate data. On the other hand, in-silico studies and flow simulations allow a thorough analysis of haemodynamics, analysing the 4D nature of blood flow patterns under different boundary conditions. However, the reduced number of cases reported on the literature of these studies has been a limitation. The main goal of this work was to study the influence of PVs on left atrium (LA) and LAA haemodynamics. Computational fluid dynamics simulations were run on 52 patients, the largest cohort so far in the literature, where different parameters were individually studied: pulmonary veins orientation and configuration; LAA and LA volumes and its ratio; and flow velocities. Our computational analysis showed how the right pulmonary vein height and angulation have a great influence on LA haemodynamics. Additionally, we found that LAA with great bending with its tip pointing towards the mitral valve could contribute to favour flow stagnation.
△ Less
Submitted 19 October, 2022;
originally announced October 2022.