-
An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
T. Akutsu,
M. Ando,
K. Arai,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu,
K. Doi,
S. Eguchi,
Y. Enomoto
, et al. (181 additional authors not shown)
Abstract:
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, wh…
▽ More
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
△ Less
Submitted 28 November, 2019; v1 submitted 2 October, 2019;
originally announced October 2019.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
All-polarization-maintaining, single-port Er:fiber comb for high-stability comparison of optical lattice clocks
Authors:
Noriaki Ohmae,
Naoya Kuse,
Martin E. Fermann,
Hidetoshi Katori
Abstract:
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135-285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical latt…
▽ More
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135-285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of $(1-2)\times 10^{-17}$ Hz$^{-1/2}$ at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measurements with $10^{-17}$ instability at 1 s, which is one order of magnitude smaller than the best instability of the frequency ratio of optical lattice clocks.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Real-time geopotentiometry with synchronously linked optical lattice clocks
Authors:
Tetsushi Takano,
Masao Takamoto,
Ichiro Ushijima,
Noriaki Ohmae,
Tomoya Akatsuka,
Atsushi Yamaguchi,
Yuki Kuroishi,
Hiroshi Munekane,
Basara Miyahara,
Hidetoshi Katori
Abstract:
According to the Einstein's theory of relativity, the passage of time changes in a gravitational field. On earth, raising a clock by one centimetre increases its tick rate by 1.1 parts in 10$^{18}$, enabling optical clocks to perform precision geodesy. Here, we demonstrate geopotentiometry by determining the height difference of master and slave clocks separated by 15 km with uncertainty of 5 cm.…
▽ More
According to the Einstein's theory of relativity, the passage of time changes in a gravitational field. On earth, raising a clock by one centimetre increases its tick rate by 1.1 parts in 10$^{18}$, enabling optical clocks to perform precision geodesy. Here, we demonstrate geopotentiometry by determining the height difference of master and slave clocks separated by 15 km with uncertainty of 5 cm. The subharmonic of the master clock is delivered through a telecom fibre to phase-lock and synchronously interrogate the slave clock. This protocol rejects laser noise in the comparison of two clocks, which improves the stability of measuring the gravitational red shift. Such phase-coherently operated clocks facilitate proposals for linking clocks and interferometers. Over half a year, 11 measurements determine the fractional frequency difference between the two clocks to be $1,652.9(5.9)\times 10^{-18}$, or a height difference of 1,516(5) cm, consistent with an independent measurement by levelling and gravimetry. Our system is as a building block of an internet of clocks, consisting of a master and a number of slave clocks, which will provide "quantum benchmarks" that are height references with dynamic response.
△ Less
Submitted 26 August, 2016;
originally announced August 2016.
-
Continuous-wave, single-frequency 229 nm laser source for laser cooling of cadmium atoms
Authors:
Yushi Kaneda,
J. M. Yarborough,
Yevgeny Merzlyak,
Atsushi Yamaguchi,
Keitaro Hayashida,
Noriaki Ohmae,
Hidetoshi Katori
Abstract:
Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the 4th harmonic using two successive second harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Co…
▽ More
Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the 4th harmonic using two successive second harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Conversion efficiency from 458 nm to 229 nm was more than 34%. By applying a tapered amplifier as a fundamental source, we demonstrated magneto-optical trap** of all stable Cd isotopes including isotopes $^{111}$Cd and $^{113}$Cd, which are applicable to optical lattice clocks.
△ Less
Submitted 11 May, 2016;
originally announced May 2016.
-
Higher order test of Lorentz invariance with an optical ring cavity
Authors:
Yuta Michimura,
Jake Guscott,
Matthew Mewes,
Nobuyuki Matsumoto,
Noriaki Ohmae,
Wataru Kokuyama,
Yoichi Aso,
Masaki Ando
Abstract:
We have developed an apparatus to search for the higher-order Lorentz violation in photons by measuring the resonant frequency difference between two counterpropagating directions of an asymmetric optical ring cavity. From the year-long data taken between 2012 and 2013, we found no evidence for the light speed anisotropy at the level of $δc/c \lesssim 10^{-15}$. Limits on the dipole components of…
▽ More
We have developed an apparatus to search for the higher-order Lorentz violation in photons by measuring the resonant frequency difference between two counterpropagating directions of an asymmetric optical ring cavity. From the year-long data taken between 2012 and 2013, we found no evidence for the light speed anisotropy at the level of $δc/c \lesssim 10^{-15}$. Limits on the dipole components of the anisotropy are improved by more than an order of magnitude, and limits on the hexapole components are obtained for the first time. An overview of our apparatus and the data analysis in the framework of the spherical harmonics decomposition of anisotropy are presented. We also present the status of the recent upgrade of the apparatus.
△ Less
Submitted 31 January, 2016;
originally announced February 2016.
-
Frequency ratio of Yb and Sr clocks with $5 \times 10^{-17}$ uncertainty at 150 s averaging time
Authors:
Nils Nemitz,
Takuya Ohkubo,
Masao Takamoto,
Ichiro Ushijima,
Manoj Das,
Noriaki Ohmae,
Hidetoshi Katori
Abstract:
Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of applications such as satellite navigation systems. Atomic clocks based on optical transitions approach uncertainties of $10^{-18}$, where full frequency descriptions…
▽ More
Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of applications such as satellite navigation systems. Atomic clocks based on optical transitions approach uncertainties of $10^{-18}$, where full frequency descriptions are far beyond the reach of the SI second. Frequency ratios of such super clocks, on the other hand, are not subject to this limitation. They can therefore verify consistency and overall accuracy for an ensemble of super clocks, an essential step towards a redefinition of the second. However, with the measurement stabilities so far reported for such frequency ratios, a confirmation to $1 \times 10^{-18}$ uncertainty would require an averaging time $τ$ of multiple months. Here we report a measurement of the frequency ratio of neutral ytterbium and strontium clocks with a much improved stability of $4 \times 10^{-16} (τ/s)^{-1/2}$. Enabled by the high stability of optical lattice clocks interrogating hundreds of atoms, this marks a 90-fold reduction in the required averaging time over a previous record-setting experiment that determined the ratio of Al+ and Hg+ single-ion clocks to an uncertainty of $5.2 \times 10^{-17}$. For the Yb/Sr ratio, we find R = 1.207 507 039 343 337 749(55), with a fractional uncertainty of $4.6 \times 10^{-17}$.
△ Less
Submitted 18 January, 2016;
originally announced January 2016.
-
Frequency ratios of Sr, Yb and Hg based optical lattice clocks and their applications
Authors:
Masao Takamoto,
Ichiro Ushijima,
Manoj Das,
Nils Nemitz,
Takuya Ohkubo,
Kazuhiro Yamanaka,
Noriaki Ohmae,
Tetsushi Takano,
Tomoya Akatsuka,
Atsushi Yamaguchi,
Hidetoshi Katori
Abstract:
This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an optical frequency comb and between two Sr clocks at remote sites using a phase-stabilized fibre link. We first review cryogenic Sr optical lattice clocks that…
▽ More
This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an optical frequency comb and between two Sr clocks at remote sites using a phase-stabilized fibre link. We first review cryogenic Sr optical lattice clocks that reduce the room-temperature blackbody radiation shift by two orders of magnitude and serve as a reference in the following clock comparisons. Similar physical properties of Sr and Yb atoms, such as transition wavelengths and vapour pressure, have allowed our development of a compatible clock for both species. A cryogenic Yb clock is evaluated by referencing a Sr clock. We also report on a Hg clock, which shows one order of magnitude less sensitivity to blackbody radiation, while its large nuclear charge makes the clock sensitive to the variation of fine-structure constant. Connecting all three types of clocks by an optical frequency comb, the ratios of the clock frequencies are determined with uncertainties smaller than possible through absolute frequency measurements. Finally, we describe a synchronous frequency comparison between two Sr-based remote clocks over a distance of 15 km between RIKEN and the University of Tokyo, as a step towards relativistic geodesy.
△ Less
Submitted 12 May, 2015;
originally announced May 2015.
-
Frequency Ratio of ${}^{199}$Hg and ${}^{87}$Sr Optical Lattice Clocks beyond the SI Limit
Authors:
Kazuhiro Yamanaka,
Noriaki Ohmae,
Ichiro Ushijima,
Masao Takamoto,
Hidetoshi Katori
Abstract:
We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 \times 10^{-17}$ for the Hg clock. The frequency ratio is measured to be…
▽ More
We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 \times 10^{-17}$ for the Hg clock. The frequency ratio is measured to be $ν_{\rm Hg}/ν_{\rm Sr}=2.629\, 314\, 209\, 898\, 909\, 60(22)$ with a fractional uncertainty of $8.4 \times 10^{-17}$, which is smaller than the uncertainty of the realization of the SI second, i.e., the SI limit.
△ Less
Submitted 26 March, 2015;
originally announced March 2015.
-
Testing Lorentz Invariance with a Double-Pass Optical Ring Cavity
Authors:
Yuta Michimura,
Nobuyuki Matsumoto,
Noriaki Ohmae,
Wataru Kokuyama,
Yoichi Aso,
Masaki Ando,
Kimio Tsubono
Abstract:
We have developed an apparatus to test Lorentz invariance in the photon sector by measuring the resonant frequency difference between two counterpropagating directions of an asymmetric optical ring cavity using a double-pass configuration. No significant evidence for the violation was found at the level of $δc /c \lesssim 10^{-14}$. Details of our apparatus and recent results are presented.
We have developed an apparatus to test Lorentz invariance in the photon sector by measuring the resonant frequency difference between two counterpropagating directions of an asymmetric optical ring cavity using a double-pass configuration. No significant evidence for the violation was found at the level of $δc /c \lesssim 10^{-14}$. Details of our apparatus and recent results are presented.
△ Less
Submitted 19 July, 2013;
originally announced July 2013.
-
New Limit on Lorentz Violation Using a Double-Pass Optical Ring Cavity
Authors:
Yuta Michimura,
Nobuyuki Matsumoto,
Noriaki Ohmae,
Wataru Kokuyama,
Yoichi Aso,
Masaki Ando,
Kimio Tsubono
Abstract:
A search for Lorentz violation in electrodynamics was performed by measuring the resonant frequency difference between two counterpropagating directions of an optical ring cavity. Our cavity contains a dielectric element, which makes our cavity sensitive to the violation. The laser frequency is stabilized to the counterclockwise resonance of the cavity, and the transmitted light is reflected back…
▽ More
A search for Lorentz violation in electrodynamics was performed by measuring the resonant frequency difference between two counterpropagating directions of an optical ring cavity. Our cavity contains a dielectric element, which makes our cavity sensitive to the violation. The laser frequency is stabilized to the counterclockwise resonance of the cavity, and the transmitted light is reflected back into the cavity for resonant frequency comparison with the clockwise resonance. This double-pass configuration enables a null experiment and gives high common mode rejection of environmental disturbances. We found no evidence for odd-parity anisotropy at the level of $δc /c \lesssim 10^{-14}$. Within the framework of the Standard Model Extension, our result put more than 5 times better limits on three odd-parity parameters $\tildeκ^{JK}_{o+}$ and a 12 times better limit on the scalar parameter $\tildeκ_{\tr}$ compared with the previous best limits.
△ Less
Submitted 14 May, 2013; v1 submitted 26 March, 2013;
originally announced March 2013.
-
Microtribological Property of Vertically Aligned Carbon Nanotube Film
Authors:
H. Kinoshita,
Ippei Kume,
Masahito Tagawa,
N. Ohmae,
Viviane Turq,
J. M. Martin
Abstract:
Microtribological properties of vertically-aligned carbon-nanotube (VACNT) films have been studied. Adhesion forces were obtained by measuring force-displacement curves. Friction experiments were conducted in reciprocating sliding configurations. Effects of tip radius, applied force, scan speed, and relative humidity were investigated. A model of the friction of VACNT film is discussed on the ba…
▽ More
Microtribological properties of vertically-aligned carbon-nanotube (VACNT) films have been studied. Adhesion forces were obtained by measuring force-displacement curves. Friction experiments were conducted in reciprocating sliding configurations. Effects of tip radius, applied force, scan speed, and relative humidity were investigated. A model of the friction of VACNT film is discussed on the basis of in-situ tribological experiments inside a scanning electron microscope (SEM).
△ Less
Submitted 5 May, 2008;
originally announced May 2008.
-
Influence of Humidity on Microtribology of Vertically Aligned Carbon Nanotube Film
Authors:
Viviane Turq,
N. Ohmae,
J. M. Martin,
J. Fontaine,
H. Kinoshita,
J. L. Loubet
Abstract:
The aim of this study is to probe the influence of water vapor environment on the microtribological properties of a forestlike vertically aligned carbon nanotube (VACNT) film, deposited on a silicon (001) substrate by chemical vapor deposition. Tribological experiments were performed using a gold tip under relative humidity varying from 0 to 100%. Very low adhesion forces and high friction coeff…
▽ More
The aim of this study is to probe the influence of water vapor environment on the microtribological properties of a forestlike vertically aligned carbon nanotube (VACNT) film, deposited on a silicon (001) substrate by chemical vapor deposition. Tribological experiments were performed using a gold tip under relative humidity varying from 0 to 100%. Very low adhesion forces and high friction coefficients of 0.6 to 1.3 resulted. The adhesion and friction forces were independent of humidity, due probably to the high hydrophobicity of VACNT. These tribological characteristics were compared to those of a diamond like carbon (DLC) sample.
△ Less
Submitted 28 March, 2007;
originally announced March 2007.