The Art of the Steal: Purloining Deep Learning Models Developed for an Ultrasound Scanner to a Competitor Machine
Authors:
Ufuk Soylu,
Varun Chandrasekeran,
Michael L. Oelze
Abstract:
A transfer function approach has recently proven effective for calibrating deep learning (DL) algorithms in quantitative ultrasound (QUS), addressing data shifts at both the acquisition and machine levels. Expanding on this approach, we develop a strategy to 'steal' the functionality of a DL model from one ultrasound machine and implement it on another, in the context of QUS. This demonstrates the…
▽ More
A transfer function approach has recently proven effective for calibrating deep learning (DL) algorithms in quantitative ultrasound (QUS), addressing data shifts at both the acquisition and machine levels. Expanding on this approach, we develop a strategy to 'steal' the functionality of a DL model from one ultrasound machine and implement it on another, in the context of QUS. This demonstrates the ease with which the functionality of a DL model can be transferred between machines, highlighting the security risks associated with deploying such models in a commercial scanner for clinical use. The proposed method is a black-box unsupervised domain adaptation technique that integrates the transfer function approach with an iterative schema. It does not utilize any information related to model internals of the victim machine but it solely relies on the availability of input-output interface. Additionally, we assume the availability of unlabelled data from the testing machine, i.e., the perpetrator machine. This scenario could become commonplace as companies begin deploying their DL functionalities for clinical use. Competing companies might acquire the victim machine and, through the input-output interface, replicate the functionality onto their own machines. In the experiments, we used a SonixOne and a Verasonics machine. The victim model was trained on SonixOne data, and its functionality was then transferred to the Verasonics machine. The proposed method successfully transferred the functionality to the Verasonics machine, achieving a remarkable 98\% classification accuracy in a binary decision task. This study underscores the need to establish security measures prior to deploying DL models in clinical settings.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
Machine-to-Machine Transfer Function in Deep Learning-Based Quantitative Ultrasound
Authors:
Ufuk Soylu,
Michael L. Oelze
Abstract:
A Transfer Function approach was recently demonstrated to mitigate data mismatches at the acquisition level for a single ultrasound scanner in deep learning (DL) based quantitative ultrasound (QUS). As a natural progression, we further investigate the transfer function approach and introduce a Machine-to-Machine (M2M) Transfer Function, which possesses the ability to mitigate data mismatches at a…
▽ More
A Transfer Function approach was recently demonstrated to mitigate data mismatches at the acquisition level for a single ultrasound scanner in deep learning (DL) based quantitative ultrasound (QUS). As a natural progression, we further investigate the transfer function approach and introduce a Machine-to-Machine (M2M) Transfer Function, which possesses the ability to mitigate data mismatches at a machine level, i.e., mismatches between two scanners over the same frequency band. This ability opens the door to unprecedented opportunities for reducing DL model development costs, enabling the combination of data from multiple sources or scanners, or facilitating the transfer of DL models between machines with ease. We tested the proposed method utilizing a SonixOne machine and a Verasonics machine. In the experiments, we used a L9-4 array and conducted two types of acquisitions to obtain calibration data: stable and free-hand, using two different calibration phantoms. Without the proposed calibration method, the mean classification accuracy when applying a model on data acquired from one system to data acquired from another system was approximately 50%, and the mean AUC was about 0.40. With the proposed method, mean accuracy increased to approximately 90%, and the AUC rose to the 0.99. Additional observations include that shifts in statistics for the z-score normalization had a significant impact on performance. Furthermore, the choice of the calibration phantom played an important role in the proposed method. Additionally, robust implementation inspired by Wiener filtering provided an effective method for transferring the domain from one machine to another machine, and it can succeed using just a single calibration view without the need for multiple independent calibration frames.
△ Less
Submitted 27 November, 2023;
originally announced November 2023.
-
A Radiological Clip Design Using Ultrasound Identification to Improve Localization
Authors:
Jenna Cario,
Zhengchang Kou,
Rita J. Miller,
April Dickenson,
Christine U. Lee,
Michael L. Oelze
Abstract:
Objective: We demonstrate the use of ultrasound to receive an acoustic signal transmitted from a radiological clip designed from a custom circuit. This signal encodes an identification number and is localized and identified wirelessly by the ultrasound imaging system. Methods: We designed and constructed the test platform with a Teensy 4.0 microcontroller core to detect ultrasonic imaging pulses r…
▽ More
Objective: We demonstrate the use of ultrasound to receive an acoustic signal transmitted from a radiological clip designed from a custom circuit. This signal encodes an identification number and is localized and identified wirelessly by the ultrasound imaging system. Methods: We designed and constructed the test platform with a Teensy 4.0 microcontroller core to detect ultrasonic imaging pulses received by a transducer embedded in a phantom, which acted as the radiological clip. Ultrasound identification (USID) signals were generated and transmitted as a result. The phantom and clip were imaged using an ultrasonic array (Philips L7-4) connected to a Verasonics Vantage 128 system operating in pulse inversion (PI) mode. Cross-correlations were performed to localize and identify the code sequences in the PI images. Results: USID signals were detected and visualized on B-mode images of the phantoms with up to sub-millimeter localization accuracy. The average detection rate across 4,800 frames of ultrasound data was 93.0%. Tested ID values exhibited differences in detection rates. Conclusion: The USID clip produced identifiable, distinguishable, and localizable signals when imaged. Significance: Radiological clips are used to mark breast cancer being treated by neoadjuvant chemotherapy (NAC) via implant in or near treated lesions. As NAC progresses, available marking clips can lose visibility in ultrasound, the imaging modality of choice for monitoring NAC-treated lesions. By transmitting an active signal, more accurate and reliable ultrasound localization of these clips could be achieved and multiple clips with different ID values could be imaged in the same field of view.
△ Less
Submitted 1 February, 2024; v1 submitted 30 August, 2023;
originally announced August 2023.
-
High-resolution Power Doppler Using Null Subtraction Imaging
Authors:
Zhengchang Kou,
Matthew Lowerison,
Qi You,
Yike Wang,
Pengfei Song,
Michael L. Oelze
Abstract:
To improve the spatial resolution of power Doppler (PD) imaging, we explored null subtraction imaging (NSI) as an alternative beamforming technique to delay-and-sum (DAS). NSI is a nonlinear beamforming approach that uses three different apodizations on receive and incoherently sums the beamformed envelopes. NSI uses a null in the beam pattern to improve the lateral resolution, which we apply here…
▽ More
To improve the spatial resolution of power Doppler (PD) imaging, we explored null subtraction imaging (NSI) as an alternative beamforming technique to delay-and-sum (DAS). NSI is a nonlinear beamforming approach that uses three different apodizations on receive and incoherently sums the beamformed envelopes. NSI uses a null in the beam pattern to improve the lateral resolution, which we apply here for improving PD spatial resolution both with and without contrast microbubbles. In this study, we used NSI with three types of singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images. An element sensitivity correction scheme was also proposed as a crucial component of NSI-based PD imaging. First, a microbubble trace experiment was performed to evaluate the resolution improvement of NSI-based PD over traditional DAS-based PD. Then, both contrast-enhanced and contrast free ultrasound PD images were generated from the scan of a rat brain. The cross-sectional profile of the microbubble traces and microvessels were plotted. FWHM was also estimated to provide a quantitative metric. Furthermore, iso-frequency curves were calculated to provide a resolution evaluation metric over the global field of view. Up to six-fold resolution improvement was demonstrated by the FWHM estimate and four-fold resolution improvement was demonstrated by the iso-frequency curve from the NSI-based PD microvessel images compared to microvessel images generated by traditional DAS-based beamforming. A resolvability of 39 um was measured from the NSI-based PD microvessel image. The computational cost of NSI-based PD was only increased by 40 percent over the DAS-based PD.
△ Less
Submitted 2 April, 2024; v1 submitted 9 January, 2023;
originally announced January 2023.
-
Grating lobe reduction in plane wave imaging with angular compounding using subtraction of coherent signals
Authors:
Zhengchang Kou,
Rita J. Miller,
Michael L. Oelze
Abstract:
Plane wave imaging (PWI) with angular compounding has gained in popularity over recent years because it provides high frame rates and good image properties. However, most linear arrays used in clinical practice have a pitch that is equal to than the wavelength of ultrasound. Hence, the presence of grating lobes is a concern for PWI using multiple transmit angles. The presence of grating lobes prod…
▽ More
Plane wave imaging (PWI) with angular compounding has gained in popularity over recent years because it provides high frame rates and good image properties. However, most linear arrays used in clinical practice have a pitch that is equal to than the wavelength of ultrasound. Hence, the presence of grating lobes is a concern for PWI using multiple transmit angles. The presence of grating lobes produces clutter in images and reduces the ability to observe tissue contrast. Techniques to reduce or eliminate the presence of grating lobes for PWI using multiple angles will result in improved image quality. Null subtraction imaging (NSI) is a nonlinear beamforming technique that has been explored for improving the lateral resolution of ultrasonic imaging. However, the apodization scheme used in NSI also eliminates or greatly reduces the presence of grating lobes. Imaging tasks using NSI were evaluated in simulations and physical experiments involving tissue-mimicking phantoms and rat tumors in vivo. Images created with NSI were compared with images created using traditional delay and sum (DAS) with Hann apodization and images created using a generalized coherence factor (GCF). NSI was observed to greatly reduce the presence of grating lobes in ultrasonic images, compared to DAS with Hann and GCF, while maintaining spatial resolution and contrast in the images. Therefore, NSI can provide a novel means of creating images using PWI with multiple steering angles on clinically available linear arrays while reducing the adverse effects associated with grating lobes.
△ Less
Submitted 24 October, 2022;
originally announced October 2022.
-
Through Tissue Ultra-high-definition Video Transmission Using an Ultrasound Communication Channel
Authors:
Zhengchang Kou,
Andrew C. Singer,
Michael L. Oelze
Abstract:
Wireless capsule endoscopy (WCE) has been widely adopted as complementary to traditional wired gastroendoscopy, especially for small bowel diseases which are beyond the latter's reach. However, both the video resolution and frame rates are limited in current WCE solutions due to the limited wireless data rate. The reasons behind this are that the electromagnetic (EM), radio frequency (RF) based co…
▽ More
Wireless capsule endoscopy (WCE) has been widely adopted as complementary to traditional wired gastroendoscopy, especially for small bowel diseases which are beyond the latter's reach. However, both the video resolution and frame rates are limited in current WCE solutions due to the limited wireless data rate. The reasons behind this are that the electromagnetic (EM), radio frequency (RF) based communication scheme used by WCE has strict limits on useable bandwidth and power, and the high attenuation in the human body compared to air. Ultrasound communication could be a potential alternative solution as it has access to much higher bandwidths and transmitted power with much lower attenuation. In this paper, we propose an ultrasound communication scheme specially designed for high data rate through tissue data transmission and validate this communication scheme by successfully transmitting ultra-high-definition (UHD) video (3840*2160 pixels at 60 FPS) through 5 cm of pork belly. Over 8.3 Mbps error free payload data rate was achieved with the proposed communication scheme and our custom-built field programmable gate array (FPGA) based test platform.
△ Less
Submitted 17 October, 2022;
originally announced October 2022.
-
Calibrating Data Mismatches in Deep Learning-Based Quantitative Ultrasound Using Setting Transfer Functions
Authors:
Ufuk Soylu,
Michael L. Oelze
Abstract:
Deep learning (DL) can fail when there are data mismatches between training and testing data. Due to its operator-dependent nature, acquisition-related data mismatches, caused by different scanner settings, can occur in ultrasound imaging. Therefore, mitigating effects of such data mismatches is essential for wider clinical adoption of DL powered ultrasound imaging. To mitigate the effects, ideall…
▽ More
Deep learning (DL) can fail when there are data mismatches between training and testing data. Due to its operator-dependent nature, acquisition-related data mismatches, caused by different scanner settings, can occur in ultrasound imaging. Therefore, mitigating effects of such data mismatches is essential for wider clinical adoption of DL powered ultrasound imaging. To mitigate the effects, ideally we need to collect a large training set at each scanner setting. However, acquiring such training sets is expensive. Another approach could be training on a subset of imaging settings, which makes the data generation less expensive. However, there will still be generalization issues. As an alternative approach that is inexpensive and generalizable, we propose to collect a large training set at a single setting and a small calibration set at each scanner setting. Then, the calibration set will be used to calibrate data mismatches by using a signals and systems perspective. We tested the proposed solution to classify two phantoms. To investigate generalizability of the proposed solution, we calibrated three types of data mismatches: pulse frequency, focus and output power mismatches. To calibrate the setting mismatches, we calculated the setting transfer functions. The CNN trained with no calibration resulted in mean classification accuracies of 55.3%, 64.4% and 70.3% for pulse frequency, focus and output power mismatches, respectively. By using the setting transfer functions, which allowed a matching of the training and testing domains, we obtained mean accuracies of 95.3%, 92.99% and 99.32%, respectively. Therefore, the incorporation of the setting transfer functions between scanner settings can provide an economical means of generalizing a DL model for specific classification tasks where scanner settings are not fixed by the operator.
△ Less
Submitted 4 October, 2022;
originally announced October 2022.
-
High-level synthesis design of scalable ultrafast ultrasound beamformer with single FPGA
Authors:
Zhengchang Kou,
Qi You,
Jihun Kim,
Zhijie Dong,
Matthew R. Lowerison,
Nathiya V. Chandra Sekaran,
Daniel A. Llano,
Pengfei Song,
Michael L. Oelze
Abstract:
Ultrafast ultrasound imaging is essential for advanced ultrasound imaging techniques such as ultrasound localization microscopy (ULM) and functional ultrasound (fUS). Current ultrafast ultrasound imaging is challenged by the ultrahigh data bandwidth associated with the radio frequency (RF) signal, and by the latency of the computationally expensive beamforming process. As such, continuous ultrafas…
▽ More
Ultrafast ultrasound imaging is essential for advanced ultrasound imaging techniques such as ultrasound localization microscopy (ULM) and functional ultrasound (fUS). Current ultrafast ultrasound imaging is challenged by the ultrahigh data bandwidth associated with the radio frequency (RF) signal, and by the latency of the computationally expensive beamforming process. As such, continuous ultrafast data acquisition and beamforming remain elusive with existing software beamformers based on CPUs or GPUs. To address these challenges, the proposed work introduces a novel method of implementing an ultrafast ultrasound beamformer specifically for ultrafast plane wave imaging (PWI) on a field programmable gate array (FPGA) by using high-level synthesis. A parallelized implementation of the beamformer on a single FPGA was proposed by 1) utilizing a delay compression technique to reduce the delay profile size, which enables both run-time pre-calculated delay profile loading from external memory and delay reuse 2) vectorizing channel data fetching which is enabled by delay reuse, and 3) using fixed summing networks to reduce consumption of logic resources. Our proposed method presents two unique advantages over current FPGA beamformers: 1) high scalability that allows fast adaptation to different FPGA resources and beamforming speed demands by using Xilinx High-Level Synthesis as the development tool, and 2) allow a compact form factor design by using a single FPGA to complete the beamforming instead of multiple FPGAs. With the proposed method, a sustainable average beamforming rate of 4.83 G samples/second in terms of input raw RF sample was achieved. The resulting image quality of the proposed beamformer was compared with the software beamformer on the Verasonics Vantage system for both phantom imaging and in vivo imaging of a mouse brain.
△ Less
Submitted 13 April, 2023; v1 submitted 5 August, 2022;
originally announced August 2022.
-
Fast Numerical Integration Techniques for 2.5-Dimensional Inverse Problems
Authors:
Mert Hidayetoglu,
Michael Oelze,
Erhan Kudeki,
Weng Cho Chew
Abstract:
Inverse scattering involving microwave and ultrasound waves require numerical solution of nonlinear optimization problem. To alleviate the computational burden of a full three-dimensional (3-D) inverse problem, it is a common practice to approximate the object as two-dimensional (2-D) and treat the transmitter and receiver sensors as 3-D, through a Fourier integration of 2-D modes of scattering. T…
▽ More
Inverse scattering involving microwave and ultrasound waves require numerical solution of nonlinear optimization problem. To alleviate the computational burden of a full three-dimensional (3-D) inverse problem, it is a common practice to approximate the object as two-dimensional (2-D) and treat the transmitter and receiver sensors as 3-D, through a Fourier integration of 2-D modes of scattering. The resulting integral is singular, and hence requires a prohibitively large number of integration points, where each point corresponds to a 2-D solution. To reduce the computational complexity, this paper proposes fast integration approaches by a set of transformations. We model the object in 2-D but the transmit and receiver pairs as 3-D; hence, we term the solution as a 2.5-D inverse problem. Convergence results indicate that the proposed integration techniques have exponential convergence and hence have a reduces the computational complexity to compute 2.5-D Green's function to solve inverse scattering problems.
△ Less
Submitted 12 July, 2022;
originally announced July 2022.
-
A Data-Efficient Deep Learning Strategy for Tissue Characterization via Quantitative Ultrasound: Zone Training
Authors:
Ufuk Soylu,
Michael L. Oelze
Abstract:
Deep learning (DL) powered biomedical ultrasound imaging is an emerging research field where researchers adapt the image analysis capabilities of DL algorithms to biomedical ultrasound imaging settings. A major roadblock to wider adoption of DL powered biomedical ultrasound imaging is that acquiring large and diverse datasets is expensive in clinical settings, which is a requirement for successful…
▽ More
Deep learning (DL) powered biomedical ultrasound imaging is an emerging research field where researchers adapt the image analysis capabilities of DL algorithms to biomedical ultrasound imaging settings. A major roadblock to wider adoption of DL powered biomedical ultrasound imaging is that acquiring large and diverse datasets is expensive in clinical settings, which is a requirement for successful DL implementation. Hence, there is a constant need for develo** data-efficient DL techniques to turn DL powered biomedical ultrasound imaging into reality. In this work, we develop a data-efficient deep learning training strategy, which we named \textit{Zone Training}. In \textit{Zone Training}, we propose to divide the complete field of view of an ultrasound image into multiple zones associated with different regions of a diffraction pattern and then, train separate DL networks for each zone. The main advantage of \textit{Zone Training} is that it requires less training data to achieve high accuracy. In this work, three different tissue-mimicking phantoms were classified by a DL network. The results demonstrated that \textit{Zone Training} required a factor of 2-5 less training data to achieve similar classification accuracies compared to a conventional training strategy.
△ Less
Submitted 13 January, 2023; v1 submitted 1 February, 2022;
originally announced February 2022.
-
Video-Streaming Biomedical Implants using Ultrasonic Waves for Communication
Authors:
Gizem Tabak,
Jae Won Choi,
Rita J. Miller,
Michael L. Oelze,
Andrew C. Singer
Abstract:
The use of wireless implanted medical devices (IMDs) is growing because they facilitate continuous monitoring of patients during normal activities, simplify medical procedures required for data retrieval and reduce the likelihood of infection associated with trailing wires. However, most of the state-of-the-art IMDs are passive and offline devices. One of the key obstacles to an active and online…
▽ More
The use of wireless implanted medical devices (IMDs) is growing because they facilitate continuous monitoring of patients during normal activities, simplify medical procedures required for data retrieval and reduce the likelihood of infection associated with trailing wires. However, most of the state-of-the-art IMDs are passive and offline devices. One of the key obstacles to an active and online IMD is the infeasibility of real-time, high-quality video broadcast from the IMD. Such broadcast would help develop innovative devices such as a video-streaming capsule endoscopy (CE) pill with therapeutic intervention capabilities. State-of-the-art IMDs employ radio-frequency electromagnetic waves for information transmission. However, high attenuation of RF-EM waves in tissues and federal restrictions on the transmit power and operable bandwidth lead to fundamental performance constraints for IMDs employing RF links, and prevent achieving high data rates that could accomodate video broadcast. In this work, ultrasonic waves were used for video transmission and broadcast through biological tissues. The proposed proof-of-concept system was tested on a porcine intestine ex vivo and a rabbit in vivo. It was demonstrated that using a millimeter-sized, implanted biocompatible transducer operating at 1.1-1.2 MHz, it was possible to transmit endoscopic video with high resolution (1280 pixels by 720 pixels) through porcine intestine wrapped with bacon, and to broadcast standard definition (640 pixels by 480 pixels) video near real-time through rabbit abdomen in vivo. A media repository that includes experimental demonstrations and media files accompanies this paper. The accompanying media repository can be found at this link: https://bit.ly/3wuc7tk.
△ Less
Submitted 27 June, 2021; v1 submitted 25 June, 2021;
originally announced June 2021.
-
Real-time video streaming in vivo using ultrasound as the communication channel
Authors:
Zhengchang Kou,
Rita J. Miller,
Andrew C. Singer,
Michael L. Oelze
Abstract:
The emergence of capsule endoscopy has provided a means of capturing video of the small intestines without having to resort to an invasive procedure involving intubation. However, real-time video streaming to a receiver outside the body remains challenging for capsule endoscopy. Traditional electromagnetic-based solutions are limited in their data rates and available power. Recently, ultrasound wa…
▽ More
The emergence of capsule endoscopy has provided a means of capturing video of the small intestines without having to resort to an invasive procedure involving intubation. However, real-time video streaming to a receiver outside the body remains challenging for capsule endoscopy. Traditional electromagnetic-based solutions are limited in their data rates and available power. Recently, ultrasound was investigated as a communication channel for through-tissue data transmission. To achieve real-time video streaming through tissue, data rates of ultrasound need to exceed 1 Mbps. In a previous study, we demonstrated ultrasound communications with data rates greater than 30 Mbps with two focused ultrasound transducers using a large footprint laboratory system through slabs of lossy tissues [1]. While the form factor of the transmitter is also crucial for capsule endoscopy, it is obvious that a large, focused transducer cannot fit within the size of a capsule. Several other challenges for achieving high-speed ultrasonic communication through tissue include strong reflections leading to multipath effects and attenuation. In this work, we demonstrate ultrasonic video communications using a mm-scale microcrystal transmitter with video streaming supplied by a camera connected to a Field Programmable Gate Array (FPGA). The signals were transmitted through a tissue-mimicking phantom and through the abdomen of a rabbit in vivo. The ultrasound signal was recorded by an array probe connected to a Verasonics Vantage system and decoded back to video. To improve the received signal quality, we combined the signal from multiple channels of the array probe. Orthogonal frequency division multiplexing (OFDM) modulation was used to reduce the receiver complexity under a strong multipath environment.
△ Less
Submitted 28 September, 2020;
originally announced September 2020.
-
Low-Complexity System and Algorithm for an Emergency Ventilator Sensor and Alarm
Authors:
Ryan M. Corey,
Evan M. Widloski,
David Null,
Brian Ricconi,
Mark Johnson,
Karen White,
Jennifer R. Amos,
Alex Pagano,
Michael Oelze,
Rachel Switzky,
Matthew B. Wheeler,
Eliot Bethke,
Clifford Shipley,
Andrew C. Singer
Abstract:
In response to the shortage of ventilators caused by the COVID-19 pandemic, many organizations have designed low-cost emergency ventilators. Many of these devices are pressure-cycled pneumatic ventilators, which are easy to produce but often do not include the sensing or alarm features found on commercial ventilators. This work reports a low-cost, easy-to-produce electronic sensor and alarm system…
▽ More
In response to the shortage of ventilators caused by the COVID-19 pandemic, many organizations have designed low-cost emergency ventilators. Many of these devices are pressure-cycled pneumatic ventilators, which are easy to produce but often do not include the sensing or alarm features found on commercial ventilators. This work reports a low-cost, easy-to-produce electronic sensor and alarm system for pressure-cycled ventilators that estimates clinically useful metrics such as pressure and respiratory rate and sounds an alarm when the ventilator malfunctions. A low-complexity signal processing algorithm uses a pair of nonlinear recursive envelope trackers to monitor the signal from an electronic pressure sensor connected to the patient airway. The algorithm, inspired by those used in hearing aids, requires little memory and performs only a few calculations on each sample so that it can run on nearly any microcontroller.
△ Less
Submitted 5 June, 2020;
originally announced June 2020.
-
Video-Capable Ultrasonic Wireless Communications through Biological Tissues
Authors:
Gizem Tabak,
Sijung Yang,
Rita Miller,
Michael Oelze,
Andrew Singer
Abstract:
Wireless implanted medical devices (IMDs) provide ease and comfort to an increasing number of patients and physicians. Currently, radiofrequency electromagnetic waves are the most commonly used method for communicating wirelessly with IMDs. However, due to the restrictions on the available bandwidth and the employable power, data rates of RF-based IMDs are limited to 267 kbps. Considering standard…
▽ More
Wireless implanted medical devices (IMDs) provide ease and comfort to an increasing number of patients and physicians. Currently, radiofrequency electromagnetic waves are the most commonly used method for communicating wirelessly with IMDs. However, due to the restrictions on the available bandwidth and the employable power, data rates of RF-based IMDs are limited to 267 kbps. Considering standard definition video streaming requiring 1.2 mbps and high definition requiring 3 mbps bitrates, it is not possible to use such devices for high data rate communication applications such as video streaming. In this work, an alternative method that utilizes ultrasonic waves for IMDs to relay information at high data rates is introduced. Advanced signal processing and communication techniques are tailored to realize the full potential of the ultrasonic channel through biological tissues. Consequently, the experiments demonstrate that video-capable data rates can be achieved with mm-sized transducers communicating through water, ex vivo beef liver, ex vivo pork chop, and in situ through the rabbit abdomen.
△ Less
Submitted 5 March, 2020; v1 submitted 28 September, 2019;
originally announced September 2019.
-
Mbps Experimental Acoustic Through-Tissue Communications: MEAT-COMMS
Authors:
Andrew Singer,
Michael Oelze,
Anthony Podkowa
Abstract:
Methods for digital, phase-coherent acoustic communication date to at least the work of Stojanjovic, et al [20], and the added robustness afforded by improved phase tracking and compensation of Johnson, et al [21]. This work explores the use of such methods for communications through tissue for potential biomedical applications, using the tremendous bandwidth available in commercial medical ultras…
▽ More
Methods for digital, phase-coherent acoustic communication date to at least the work of Stojanjovic, et al [20], and the added robustness afforded by improved phase tracking and compensation of Johnson, et al [21]. This work explores the use of such methods for communications through tissue for potential biomedical applications, using the tremendous bandwidth available in commercial medical ultrasound transducers. While long-range ocean acoustic experiments have been at rates of under 100kbps, typically on the order of 1- 10kbps, data rates in excess of 120Mb/s have been achieved over cm-scale distances in ultrasonic testbeds [19]. This paper describes experimental transmission of digital communication signals through samples of real pork tissue and beef liver, achieving data rates of 20-30Mbps, demonstrating the possibility of real-time video-rate data transmission through tissue for inbody ultrasonic communications with implanted medical devices.
△ Less
Submitted 16 March, 2016;
originally announced March 2016.
-
Computing The Extension Complexities of All 4-Dimensional 0/1-Polytopes
Authors:
Michael Oelze,
Arnaud Vandaele,
Stefan Weltge
Abstract:
We present slight refinements of known general lower and upper bounds on sizes of extended formulations for polytopes. With these observations we are able to compute the extension complexities of all 0/1-polytopes up to dimension 4. We provide a complete list of our results including geometric constructions of minimum size extensions for all considered polytopes. Furthermore, we show that all of t…
▽ More
We present slight refinements of known general lower and upper bounds on sizes of extended formulations for polytopes. With these observations we are able to compute the extension complexities of all 0/1-polytopes up to dimension 4. We provide a complete list of our results including geometric constructions of minimum size extensions for all considered polytopes. Furthermore, we show that all of these extensions have strong properties. In particular, one of our computational results is that every 0/1-polytope up to dimension 4 has a minimum size extension that is also a 0/1-polytope.
△ Less
Submitted 18 June, 2014;
originally announced June 2014.