-
Orbital and Atmospheric Characterization of the 1RXS J034231.8+121622 System Using High-Resolution Spectroscopy Confirms That The Companion is a Low-Mass Star
Authors:
Clarissa R. Do Ó,
Ben Sappey,
Quinn M. Konopacky,
Jean-Baptiste Ruffio,
Kelly K. O'Neil,
Tuan Do,
Gregory Martinez,
Travis S. Barman,
Jayke S. Nguyen,
Jerry W. Xuan,
Christopher A. Theissen,
Sarah Blunt,
William Thompson,
Chih-Chun Hsu,
Ashley Baker,
Randall Bartos,
Geoffrey A. Blake,
Benjamin Calvin,
Sylvain Cetre,
Jacques-Robert Delorme,
Greg Doppmann,
Daniel Echeverri,
Luke Finnerty,
Michael P. Fitzgerald,
Julie Inglis
, et al. (11 additional authors not shown)
Abstract:
The 1RXS J034231.8+121622 system consists of an M dwarf primary and a directly imaged low-mass stellar companion. We use high resolution spectroscopic data from Keck/KPIC to estimate the objects' atmospheric parameters and radial velocities (RVs). Using PHOENIX stellar models, we find that the primary has a temperature of 3460 $\pm$ 50 K a metallicity of 0.16 $\pm$ 0.04, while the secondary has a…
▽ More
The 1RXS J034231.8+121622 system consists of an M dwarf primary and a directly imaged low-mass stellar companion. We use high resolution spectroscopic data from Keck/KPIC to estimate the objects' atmospheric parameters and radial velocities (RVs). Using PHOENIX stellar models, we find that the primary has a temperature of 3460 $\pm$ 50 K a metallicity of 0.16 $\pm$ 0.04, while the secondary has a temperature of 2510 $\pm$ 50 K and a metallicity of $0.13\substack{+0.12 \\ -0.11}$. Recent work suggests this system is associated with the Hyades, placing it an older age than previous estimates. Both metallicities agree with current $[Fe/H]$ Hyades measurements (0.11 -- 0.21). Using stellar evolutionary models, we obtain significantly higher masses for the objects, of 0.30 $\pm$ 0.15 $M_\odot$ and 0.08 $\pm$ 0.01 $M_\odot$ (84 $\pm$ 11 $M_{Jup}$) respectively. Using the RVs and a new astrometry point from Keck/NIRC2, we find that the system is likely an edge-on, moderately eccentric ($0.41\substack{+0.27 \\ -0.08}$) configuration. We also estimate the C/O ratio of both objects using custom grid models, obtaining 0.42 $\pm$ 0.10 (primary) and 0.55 $\pm$ 0.10 (companion). From these results, we confirm that this system most likely went through a binary star formation process in the Hyades. The significant changes in this system's parameters since its discovery highlight the importance of high resolution spectroscopy for both orbital and atmospheric characterization of directly imaged companions.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
F-characteristic cycle of a rank one sheaf on an arithmetic surface
Authors:
Ryosuke Ooe
Abstract:
We prove the rationality of the characteristic form for a degree one character of the Galois group of an abelian extension of henselian discrete valuation fields. We prove the integrality of the characteristic form for a rank one sheaf on a regular excellent scheme. These properties are shown by reducing to the corresponding properties of the refined Swan conductor proved by Kato. We define the F-…
▽ More
We prove the rationality of the characteristic form for a degree one character of the Galois group of an abelian extension of henselian discrete valuation fields. We prove the integrality of the characteristic form for a rank one sheaf on a regular excellent scheme. These properties are shown by reducing to the corresponding properties of the refined Swan conductor proved by Kato. We define the F-characteristic cycle of a rank one sheaf on an arithmetic surface as a cycle on the FW-cotangent bundle using the characteristic form on the basis of the computation of the characteristic cycle in the equal characteristic case by Yatagawa. The rationality and the integrality of the characteristic form are necessary for the definition of the F-characteristic cycle. We prove the intersection of the F-characteristic cycle with the 0-section computes the Swan conductor of cohomology of the generic fiber.
△ Less
Submitted 1 March, 2024; v1 submitted 8 February, 2024;
originally announced February 2024.
-
Octofitter: Fast, Flexible, and Accurate Orbit Modelling to Detect Exoplanets
Authors:
William Thompson,
Jensen Lawrence,
Dori Blakely,
Christian Marois,
Jason Wang,
Mosé Giordano,
Timothy Brandt,
Doug Johnstone,
Jean-Baptiste Ruffio,
S. Mark Ammons,
Katie A. Crotts,
Clarissa R. Do Ó,
Eileen C. Gonzales,
Malena Rice
Abstract:
As next-generation imaging instruments and interferometers search for planets closer to their stars, they must contend with increasing orbital motion and longer integration times. These compounding effects make it difficult to detect faint planets but also present an opportunity. Increased orbital motion makes it possible to move the search for planets into the orbital domain, where direct images…
▽ More
As next-generation imaging instruments and interferometers search for planets closer to their stars, they must contend with increasing orbital motion and longer integration times. These compounding effects make it difficult to detect faint planets but also present an opportunity. Increased orbital motion makes it possible to move the search for planets into the orbital domain, where direct images can be freely combined with the radial velocity and proper motion anomaly, even without a confirmed detection in any single epoch. In this paper, we present a fast and differentiable multimethod orbit-modeling and planet detection code called Octofitter. This code is designed to be highly modular and allows users to easily adjust priors, change parameterizations, and specify arbitrary function relations between the parameters of one or more planets. Octofitter further supplies tools for examining model outputs including prior and posterior predictive checks and simulation-based calibration. We demonstrate the capabilities of Octofitter on real and simulated data from different instruments and methods, including HD 91312, simulated JWST/NIRISS aperture masking interferometry observations, radial velocity curves, and grids of images from the Gemini Planet Imager. We show that Octofitter can reliably recover faint planets in long sequences of images with arbitrary orbital motion. This publicly available tool will enable the broad application of multiepoch and multimethod exoplanet detection, which could improve how future targeted ground- and space-based surveys are performed. Finally, its rapid convergence makes it a useful addition to the existing ecosystem of tools for modeling the orbits of directly imaged planets.
△ Less
Submitted 2 February, 2024;
originally announced February 2024.
-
Validation of elemental and isotopic abundances in late-M spectral types with the benchmark HIP 55507 AB system
Authors:
Jerry W. Xuan,
Jason J. Wang,
Luke Finnerty,
Katelyn Horstman,
Simon Grimm,
Anne Peck,
Eric L. Nielsen,
Heather A. Knutson,
Dimitri Mawet,
Howard Isaacson,
Andrew W. Howard,
Michael C. Liu,
Sam Walker,
Mark Phillips,
Geoffrey Blake,
Jean-Baptiste Ruffio,
Yapeng Zhang,
Julie Inglis,
Nicole L. Wallack,
Aniket Sanghi,
Erica Gonzales,
Fei Dai,
Ashley Baker,
Randall Bartos,
Charlotte Bond
, et al. (26 additional authors not shown)
Abstract:
M dwarfs are common host stars to exoplanets but often lack atmospheric abundance measurements. Late-M dwarfs are also good analogs to the youngest substellar companions, which share similar $T_{\rm eff}\sim2300-2800~K$. We present atmospheric analyses for the M7.5 companion HIP 55507 B and its K6V primary star with Keck/KPIC high-resolution ($R\sim35,000$) $K$ band spectroscopy. First, by includi…
▽ More
M dwarfs are common host stars to exoplanets but often lack atmospheric abundance measurements. Late-M dwarfs are also good analogs to the youngest substellar companions, which share similar $T_{\rm eff}\sim2300-2800~K$. We present atmospheric analyses for the M7.5 companion HIP 55507 B and its K6V primary star with Keck/KPIC high-resolution ($R\sim35,000$) $K$ band spectroscopy. First, by including KPIC relative radial velocities between the primary and secondary in the orbit fit, we improve the dynamical mass precision by 60% and find $M_B=88.0_{-3.2}^{+3.4}$ $M_{\rm Jup}$, putting HIP 55507 B above the stellar-substellar boundary. We also find that HIP 55507 B orbits its K6V primary star with $a=38^{+4}_{-3}$ AU and $e=0.40\pm0.04$. From atmospheric retrievals of HIP 55507 B, we measure $\rm [C/H]=0.24\pm0.13$, $\rm [O/H]=0.15\pm0.13$, and $\rm C/O=0.67\pm0.04$. Moreover, we strongly detect $\rm ^{13}CO$ ($7.8σ$ significance) and tentatively detect $\rm H_2^{18}O$ ($3.7σ$ significance) in companion's atmosphere, and measure $\rm ^{12}CO/^{13}CO=98_{-22}^{+28}$ and $\rm H_2^{16}O/H_2^{18}O=240_{-80}^{+145}$ after accounting for systematic errors. From a simplified retrieval analysis of HIP 55507 A, we measure $\rm ^{12}CO/^{13}CO=79_{-16}^{+21}$ and $\rm C^{16}O/C^{18}O=288_{-70}^{+125}$ for the primary star. These results demonstrate that HIP 55507 A and B have consistent $\rm ^{12} C/^{13}C$ and $\rm ^{16}O/^{18}O$ to the $<1σ$ level, as expected for a chemically homogeneous binary system. Given the similar flux ratios and separations between HIP 55507 AB and systems with young, substellar companions, our results open the door to systematically measuring $\rm ^{13}CO$ and $\rm H_2^{18}O$ abundances in the atmospheres of substellar or even planetary-mass companions with similar spectral types.
△ Less
Submitted 4 December, 2023;
originally announced December 2023.
-
A Uniform Analysis of Debris Disks with the Gemini Planet Imager I: An Empirical Search for Perturbations from Planetary Companions in Polarized Light Images
Authors:
Katie A. Crotts,
Brenda C. Matthews,
Gaspard Duchêne,
Thomas M. Esposito,
Ruobing Dong,
Justin Hom,
Rebecca Oppenheimer,
Malena Rice,
Schuyler G. Wolff,
Christine H. Chen,
Clarissa R. Do Ó,
Paul Kalas,
Briley L. Lewis,
Alycia J. Weinberger,
David J. Wilner,
Mark Ammons,
Pauline Arriaga,
Robert J. De Rosa,
John H. Debes,
Michael P. Fitzgerald,
Eileen C. Gonzales,
Dean C. Hines,
Sasha Hinkley,
A. Meredith Hughes,
Ludmilla Kolokolova
, et al. (15 additional authors not shown)
Abstract:
The Gemini Planet Imager (GPI) has excelled in imaging debris disks in the near-infrared. The GPI Exoplanet Survey (GPIES) imaged twenty-four debris disks in polarized $H$-band light, while other programs observed half of these disks in polarized $J$- and/or $K1$-bands. Using these data, we present a uniform analysis of the morphology of each disk to find asymmetries suggestive of perturbations, p…
▽ More
The Gemini Planet Imager (GPI) has excelled in imaging debris disks in the near-infrared. The GPI Exoplanet Survey (GPIES) imaged twenty-four debris disks in polarized $H$-band light, while other programs observed half of these disks in polarized $J$- and/or $K1$-bands. Using these data, we present a uniform analysis of the morphology of each disk to find asymmetries suggestive of perturbations, particularly those due to planet-disk interactions. The multi-wavelength surface brightness, the disk color and geometry permit identification of any asymmetries such as warps or disk offsets from the central star. We find that nineteen of the disks in this sample exhibit asymmetries in surface brightness, disk color, disk geometry, or a combination of the three, suggesting that for this sample, perturbations, as seen in scattered light, are common. The relationship between these perturbations and potential planets in the system are discussed. We also explore correlations among stellar temperatures, ages, disk properties, and observed perturbations. We find significant trends between the vertical aspect ratio and the stellar temperature, disk radial extent, and the dust grain size distribution power-law, $q$. We also confirm a trend between the disk color and stellar effective temperature, where the disk becomes increasingly red/neutral with increasing temperature. Such results have important implications on the evolution of debris disk systems around stars of various spectral types.
△ Less
Submitted 24 November, 2023;
originally announced November 2023.
-
GPI 2.0: Performance Evaluation of the Wavefront Sensor's EMCCD
Authors:
Clarissa R. Do Ó,
Saavidra Perera,
Jérôme Maire,
Jayke S. Nguyen,
Vincent Chambouleyron,
Quinn M. Konopacky,
Jeffrey Chilcote,
Joeleff Fitzsimmons,
Randall Hamper,
Dan Kerley,
Bruce Macintosh,
Christian Marois,
Fredrik Rantakyrö,
Dmitry Savranksy,
Jean-Pierre Veran,
Guido Agapito,
S. Mark Ammons,
Marco Bonaglia,
Marc-Andre Boucher,
Jennifer Dunn,
Simone Esposito,
Guillaume Filion,
Jean Thomas Landry,
Olivier Lardiere,
Duan Li
, et al. (4 additional authors not shown)
Abstract:
The Gemini Planet Imager (GPI) is a high contrast imaging instrument that aims to detect and characterize extrasolar planets. GPI is being upgraded to GPI 2.0, with several subsystems receiving a re-design to improve the instrument's contrast. To enable observations on fainter targets and increase stability on brighter ones, one of the upgrades is to the adaptive optics system. The current Shack-H…
▽ More
The Gemini Planet Imager (GPI) is a high contrast imaging instrument that aims to detect and characterize extrasolar planets. GPI is being upgraded to GPI 2.0, with several subsystems receiving a re-design to improve the instrument's contrast. To enable observations on fainter targets and increase stability on brighter ones, one of the upgrades is to the adaptive optics system. The current Shack-Hartmann wavefront sensor (WFS) is being replaced by a pyramid WFS with an low-noise electron multiplying CCD (EMCCD). EMCCDs are detectors capable of counting single photon events at high speed and high sensitivity. In this work, we characterize the performance of the HNü 240 EMCCD from Nüvü Cameras, which was custom-built for GPI 2.0. The HNü 240 EMCCD's characteristics make it well suited for extreme AO: it has low dark current ($<$ 0.01 e-/pix/fr), low readout noise (0.1 e-/pix/fr at a gain of 5000), high quantum efficiency ( 90% at wavelengths from 600-800 nm; 70% from 800-900 nm), and fast readout (up to 3000 fps full frame). Here we present test results on the EMCCD's noise contributors, such as the readout noise, pixel-to-pixel variability and CCD bias. We also tested the linearity and EM gain calibration of the detector. All camera tests were conducted before its integration into the GPI 2.0 PWFS system.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
Distance Matrices for Conjugate Skew Gain Graphs
Authors:
Shahul Hameed K,
Ramakrishnan K O,
Biju K
Abstract:
A conjugate skew gain graph is a skew gain graph with the labels (also called, the conjugate skew gains) from the field of complex numbes on the oriented edges such that they get conjugated when we reverse the orientation. In this paper we introduce distance matrices for conjugate skew gain graphs and characterize balanced conjugate skew gain graphs using these matrices. We provide explicit formul…
▽ More
A conjugate skew gain graph is a skew gain graph with the labels (also called, the conjugate skew gains) from the field of complex numbes on the oriented edges such that they get conjugated when we reverse the orientation. In this paper we introduce distance matrices for conjugate skew gain graphs and characterize balanced conjugate skew gain graphs using these matrices. We provide explicit formulae for the distance spectra of certain conjugate skew gain graphs.
△ Less
Submitted 11 July, 2023;
originally announced July 2023.
-
The Orbital Eccentricities of Directly Imaged Companions Using Observable-Based Priors: Implications for Population-level Distributions
Authors:
Clarissa R. Do Ó,
Kelly K. O'Neil,
Quinn M. Konopacky,
Tuan Do,
Gregory D. Martinez,
Jean-Baptiste Ruffio,
Andrea M. Ghez
Abstract:
The eccentricity of a sub-stellar companion is an important tracer of its formation history. Directly imaged companions often present poorly constrained eccentricities. A recently developed prior framework for orbit fitting called ''observable-based priors'' has the advantage of improving biases in derived orbit parameters for objects with minimal phase coverage, which is the case for the majority…
▽ More
The eccentricity of a sub-stellar companion is an important tracer of its formation history. Directly imaged companions often present poorly constrained eccentricities. A recently developed prior framework for orbit fitting called ''observable-based priors'' has the advantage of improving biases in derived orbit parameters for objects with minimal phase coverage, which is the case for the majority of directly imaged companions. We use observable-based priors to fit the orbits of 21 exoplanets and brown dwarfs in an effort to obtain the eccentricity distributions with minimized biases. We present the objects' individual posteriors compared to their previously derived distributions, showing in many cases a shift toward lower eccentricities. We analyze the companions' eccentricity distribution at a population level, and compare this to the distributions obtained with the traditional uniform priors. We fit a Beta distribution to our posteriors using observable-based priors, obtaining shape parameters $α= 1.09^{+0.30}_{-0.22}$ and $β= 1.42^{+0.33}_{-0.25}$. This represents an approximately flat distribution of eccentricities. The derived $α$ and $β$ parameters are consistent with the values obtained using uniform priors, though uniform priors lead to a tail at high eccentricities. We find that separating the population into high and low mass companions yields different distributions depending on the classification of intermediate mass objects. We also determine via simulation that the minimal orbit coverage needed to give meaningful posteriors under the assumptions made for directly imaged planets is $\approx$ 15% of the inferred period of the orbit.
△ Less
Submitted 18 July, 2023; v1 submitted 6 June, 2023;
originally announced June 2023.
-
Fault Tolerant FPGA Implementation on Redundancy Techniques and ECG Denoising
Authors:
Sathvik Reddy O,
Sakthivel SM
Abstract:
As more the communications and signal process we use in the today life the more we intend to develop more reliable devices which gives fewer errors due to transient fault, So we use a technique called 5-modular redundancy to generate fewer errors. 5-Modular redundancy is an approach to increasing the reliability of hardware systems constructed from component devices that are subject to failure. In…
▽ More
As more the communications and signal process we use in the today life the more we intend to develop more reliable devices which gives fewer errors due to transient fault, So we use a technique called 5-modular redundancy to generate fewer errors. 5-Modular redundancy is an approach to increasing the reliability of hardware systems constructed from component devices that are subject to failure. In digital signal processing and many other important daily life subjects FIR digital filters are used and they alike performing multiplications, complex computations and selecting desired frequency for different applications. FIR filters comprise of multipliers, adders, delay units. FIR filters has been chosen because it offers more steadiness and simple execution because of its limited length and no feedback within the circuit. Fir filter is most important for the signal processing and also used in daily life basis. The noise reduction can be performed by denoising of the signals of all the implementations .The proposed FPGA methods use Xilinx Vivado EDA.
△ Less
Submitted 17 April, 2023;
originally announced April 2023.
-
Deep orbital search for additional planets in the HR 8799 system
Authors:
William Thompson,
Christian Marois,
Clarissa R. Do Ó,
Quinn Konopacky,
Jean-Baptiste Ruffio,
Jason Wang,
Andy J. Skemer,
Robert J. De Rosa,
Bruce Macintosh
Abstract:
The HR 8799 system hosts four massive planets orbiting 15 and 80 AU. Studies of the system's orbital stability and its outer debris disk open the possibility of additional planets, both interior to and exterior to the known system. Reaching a sufficient sensitivity to search for interior planets is very challenging due to the combination of bright quasi static speckle noise close to the stellar di…
▽ More
The HR 8799 system hosts four massive planets orbiting 15 and 80 AU. Studies of the system's orbital stability and its outer debris disk open the possibility of additional planets, both interior to and exterior to the known system. Reaching a sufficient sensitivity to search for interior planets is very challenging due to the combination of bright quasi static speckle noise close to the stellar diffraction core and relatively fast orbital motion. In this work, we present a deep L-band imaging campaign using NIRC2 at Keck comprising 14 observing sequences. We further re-reduce archival data for a total of 16.75 hours, one of the largest uniform datasets of a single direct imaging target. Using a Bayesian modeling technique for detecting planets in images while compensating for plausible orbital motion, we then present deep limits on the existence of additional planets in the HR 8799 system. The final combination shows a tentative candidate, consistent with 4-7 $M_{jup}$ at 4-5 AU, detected with an equivalent false alarm probability better than $3σ$. This analysis technique is widely applicable to archival data and to new observations from upcoming missions that revisit targets at multiple epochs.
△ Less
Submitted 1 November, 2022; v1 submitted 25 October, 2022;
originally announced October 2022.
-
Rapid, high-sensitivity detection of biomolecules using dual-comb biosensing: application to the SARS-CoV-2 nucleocapsid protein
Authors:
Shogo Miyamura,
Ryo Oe,
Takuya Nakahara,
Shota Okada,
Shuji Taue,
Yu Tokizane,
Takeo Minamikawa,
Taka-aki Yano,
Kunihiro Otsuka,
Ayuko Sakane,
Takuya Sasaki,
Koji Yasutomo,
Taira Kajisa,
Takeshi Yasui
Abstract:
Rapid, sensitive detection of biomolecules is important for improved testing methods for viruses as well as biomarkers and environmental hormones. For example, testing for SARS-CoV-2 is essential in the fight against the COVID-19 pandemic. Reverse-transcription polymerase chain reaction (RT-PCR) is the current standard for COVID-19 testing; however, it is hampered by the long testing process. Shor…
▽ More
Rapid, sensitive detection of biomolecules is important for improved testing methods for viruses as well as biomarkers and environmental hormones. For example, testing for SARS-CoV-2 is essential in the fight against the COVID-19 pandemic. Reverse-transcription polymerase chain reaction (RT-PCR) is the current standard for COVID-19 testing; however, it is hampered by the long testing process. Shortening the testing process while achieving high sensitivity would facilitate sooner quarantine and thus presumably prevention of the spread of SARS-CoV-2. Here, we aim to achieve rapid, sensitive detection of the SARS-CoV-2 nucleocapsid protein by enhancing the performance of optical biosensing with a dual-comb configuration of optical frequency combs. The virus-concentration-dependent optical spectrum shift is transformed into a photonic RF shift by frequency conversion between the optical and RF regions, facilitating mature electrical frequency measurements. Furthermore, active-dummy temperature-drift compensation enables very small changes in the virus-concentration-dependent signal to be extracted from the large, variable background signal. This dual-comb biosensing technique has the potential to reduce the COVID-19 testing time to 10 min while maintaining sensitivity close to that of RT-PCR. Furthermore, this system can be applied for sensing of not only viruses but also various biomolecules for clinical diagnosis, health care, and environmental monitoring.
△ Less
Submitted 26 July, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
On the Metric Dimension of Signed Graphs
Authors:
Shahul Hameed K,
Remna K P,
Divya T2,
Biju K,
Rajeevan P,
Santhosh G O2,
Ramakrishnan K O
Abstract:
A signed graph $Σ$ is a pair $(G,σ)$, where $G=(V,E)$ is the underlying graph in which each edge is assigned $+1$ or $-1$ by the signature function $σ:E\rightarrow\{-1,+1\}$. In this paper, we extend the extensively applied concepts of metric dimension and resolving sets for unsigned graphs to signed graphs. We analyze the metric dimension of some well known classes of signed graphs including a sp…
▽ More
A signed graph $Σ$ is a pair $(G,σ)$, where $G=(V,E)$ is the underlying graph in which each edge is assigned $+1$ or $-1$ by the signature function $σ:E\rightarrow\{-1,+1\}$. In this paper, we extend the extensively applied concepts of metric dimension and resolving sets for unsigned graphs to signed graphs. We analyze the metric dimension of some well known classes of signed graphs including a special case of signed trees. Among other things, we establish that the metric dimension of a signed graph is invariant under negation.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
Scan-less full-field fluorescence-lifetime dual-comb microscopy using two-dimensional spectral map** and frequency multiplexing of dual-optical-comb beats
Authors:
Takahiko Mizuno,
Eiji Hase,
Takeo Minamikawa,
Yu Tokizane,
Ryo Oe,
Hidenori Koresawa,
Hirotsugu Yamamoto,
Takeshi Yasui
Abstract:
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool for quantitative fluorescence imaging because fluorescence lifetime is independent of concentration of fluorescent molecules or excitation/detection efficiency and is robust to photobleaching. However, since FLIM is based on point-to-point measurements, mechanical scanning of a focal spot is needed for forming an image, which hampe…
▽ More
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool for quantitative fluorescence imaging because fluorescence lifetime is independent of concentration of fluorescent molecules or excitation/detection efficiency and is robust to photobleaching. However, since FLIM is based on point-to-point measurements, mechanical scanning of a focal spot is needed for forming an image, which hampers rapid imaging. In this article, we demonstrate scan-less full-field FLIM based on a one-to-one correspondence between two-dimensional (2D) image pixels and frequency-multiplexed RF signals. A vast number of dual-optical-comb beats between dual optical frequency combs is effectively adopted for 2D spectral map** and high-density frequency multiplexing in radio-frequency region. Bimodal images of fluorescence amplitude and lifetime are obtained with high quantitativeness from amplitude and phase spectra of fluorescence RF comb modes without the need for mechanical scanning. The proposed method will be useful for rapid quantitative fluorescence imaging in life science.
△ Less
Submitted 20 March, 2020;
originally announced March 2020.
-
Optical image amplification in dual-comb microscopy by use of optical-fiber-amplified interferogram
Authors:
Takahiko Mizuno,
Takuya Tsuda,
Eiji Hase,
Yu Tokizane,
Ryo Oe,
Hidenori Koresawa,
Hirotsugu Yamamoto,
Takeo Minamikawa,
Takeshi Yasui
Abstract:
Dual-comb microscopy (DCM), based on a combination of dual-comb spectroscopy (DCS) with two-dimensional spectral encoding (2D-SE), is a promising method for scan-less confocal laser microscopy giving an amplitude and phase image contrast with the confocality. However, signal loss in a 2D-SE optical system hampers increase in image acquisition rate due to decreased signa-to-noise ratio. In this art…
▽ More
Dual-comb microscopy (DCM), based on a combination of dual-comb spectroscopy (DCS) with two-dimensional spectral encoding (2D-SE), is a promising method for scan-less confocal laser microscopy giving an amplitude and phase image contrast with the confocality. However, signal loss in a 2D-SE optical system hampers increase in image acquisition rate due to decreased signa-to-noise ratio. In this article, we demonstrated optical image amplification in DCM with an erbium-doped fiber amplifier (EDFA). Combined use of image-encoded DCS interferogram and EDFA benefits from not only the batch amplification of amplitude and phase images but also significant rejection of amplified spontaneous emission (ASE) background. Effectiveness of the optical-image-amplified DCM is highlighted in the single-shot quantitative nanometer-order surface topography and the real-time movie of polystyrene beads dynamics under water convection. The proposed method will be a powerful tool for real-time observation of surface topography and fast dynamic phenomena.
△ Less
Submitted 20 January, 2020;
originally announced January 2020.
-
Refractive index sensing with temperature compensation by a multimode-interference fiber-based optical frequency comb sensing cavity
Authors:
Ryo Oe,
Takeo Minamikawa,
Shuji Taue,
Hidenori Koresawa,
Takahiko Mizuno,
Masatomo Yamagiwa,
Yasuhiro Mizutani,
Hirotsugu Yamamoto,
Tetsuo Iwata,
Takeshi Yasui
Abstract:
We proposed a refractive index (RI) sensing method with temperature compensation by using an optical frequency comb (OFC) sensing cavity employing a multimode-interference (MMI) fiber, namely, the MMI-OFC sensing cavity. The MMI-OFC sensing cavity enables simultaneous measurement of material-dependent RI and sample temperature by decoding from the comb spacing frequency shift and the wavelength sh…
▽ More
We proposed a refractive index (RI) sensing method with temperature compensation by using an optical frequency comb (OFC) sensing cavity employing a multimode-interference (MMI) fiber, namely, the MMI-OFC sensing cavity. The MMI-OFC sensing cavity enables simultaneous measurement of material-dependent RI and sample temperature by decoding from the comb spacing frequency shift and the wavelength shift of the OFC. We realized the simultaneous and continuous measurement of RI-related concentration of a liquid sample and its temperature with precisions of 1.6*10^-4 RIU and 0.08 degree. The proposed method would be a useful means for the various applications based on RI sensing.
△ Less
Submitted 13 May, 2019;
originally announced May 2019.
-
Lock-in-detection dual-comb spectroscopy
Authors:
Hidenori Koresawa,
Kyuki Shibuya,
Takeo Minamikawa,
Akifumi Asahara,
Ryo Oe,
Takahiko Mizuno,
Masatomo Yamagiwa,
Yasuhiro Mizutani,
Tetsuo Iwata,
Hirotsugu Yamamoto,
Kaoru Minoshima,
Takeshi Yasui
Abstract:
Dual-comb spectroscopy (DCS) is useful for gas spectroscopy due to high potential of optical frequency comb (OFC). However, fast Fourier transform (FFT) calculation of a huge amount of temporal data spends significantly longer time than the acquisition time of an interferogram. In this article, we demonstrate frequency-domain DCS by a combination of DCS with lock-in detection, namely LID-DCS. LID-…
▽ More
Dual-comb spectroscopy (DCS) is useful for gas spectroscopy due to high potential of optical frequency comb (OFC). However, fast Fourier transform (FFT) calculation of a huge amount of temporal data spends significantly longer time than the acquisition time of an interferogram. In this article, we demonstrate frequency-domain DCS by a combination of DCS with lock-in detection, namely LID-DCS. LID-DCS directly extracts an arbitrary OFC mode from a vast number of OFC modes without the need for FFT calculation. Usefulness of LID-DCS is demonstrated in rapid monitoring of transient signal change and spectroscopy of hydrogen cyanide gas.
△ Less
Submitted 6 April, 2019;
originally announced April 2019.
-
Multicascade-linked synthetic wavelength digital holography using an optical-comb-referenced frequency synthesizer
Authors:
Masatomo Yamagiwa,
Takeo Minamikawa,
Clément Trovato,
Takayuki Ogawa,
Dahi Ghareab Abdelsalam Ibrahim,
Yusuke Kawahito,
Ryo Oe,
Kyuki Shibuya,
Takahiko Mizuno,
Emmanuel Abraham,
Yasuhiro Mizutani,
Tetsuo Iwata Hirotsugu Yamamoto,
Kaoru Minoshima,
Takeshi Yasui
Abstract:
Digital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrap** ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.e., s…
▽ More
Digital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrap** ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.e., synthetic wavelength DH, can expand the axial range up to a few tens of microns, this method is still insufficient for practical applications. In this article, a tunable external cavity laser diode phase-locked to an optical frequency comb, namely, an optical-comb-referenced frequency synthesizer, is effectively used for multiple synthetic wavelengths within the range of 32 um to 1.20 m. A multiple cascade link of the phase images among an optical wavelength (= 1.520 um) and 5 different synthetic wavelengths (= 32.39 um, 99.98 um, 400.0 um, 1003 um, and 4021 um) enables the shape measurement of a reflective millimeter-sized stepped surface with the axial resolution of 34 nm. The axial dynamic range, defined as the ratio of the maximum axial range (= 0.60 m) to the axial resolution (= 34 nm), achieves 1.7*10^8, which is much larger than that of previous synthetic wavelength DH. Such a wide axial dynamic range capability will further expand the application field of DH for large objects with meter dimensions.
△ Less
Submitted 27 July, 2018;
originally announced August 2018.
-
Refractive-index-sensing radio-frequency comb with intracavity multi-mode interference fibre sensor
Authors:
Roy Oe,
Shuji Taue,
Takeo Minamikawa,
Kosuke Nagai,
Yasuhiro Mizutani,
Tetsuo Iwata,
Hirotsugu Yamamoto,
Hideki Fukano,
Yoshiaki Nakajima,
Kaoru Minoshima,
Takeshi Yasui
Abstract:
Optical frequency combs have attracted attention as optical frequency rulers due to their tooth-like discrete spectra together with their inherent mode-locking nature and phase-locking control to a frequency standard. Based on this concept, their applications until now have been demonstrated in the fields of optical frequency metrology and optical distance metrology. However, if the utility of opt…
▽ More
Optical frequency combs have attracted attention as optical frequency rulers due to their tooth-like discrete spectra together with their inherent mode-locking nature and phase-locking control to a frequency standard. Based on this concept, their applications until now have been demonstrated in the fields of optical frequency metrology and optical distance metrology. However, if the utility of optical combs can be further expanded beyond their optical-frequency-ruler-based application by exploiting new aspects of optical combs, this will lead to new developments in optical metrology and instrumentation. Here, we report a fibre sensing application of optical combs based on a coherent frequency link between the optical and radio-frequency regions, enabling high-precision refractive index measurement of a liquid sample based on frequency measurement in radio-frequency region. Our technique encodes a refractive index change of a liquid sample into a radio-frequency comb by a combination of an intracavity multi-mode-interference fibre sensor and wavelength dispersion of a cavity fibre. Then, the change in refractive index is read out by measuring the repetition frequency of the radio-frequency comb with a frequency counter and a frequency standard. Use of an optical comb as a photonic radio-frequency converter will lead to the development of new applications in high-precision fibre sensing with the help of functional fibre sensors and precise radio-frequency measurement.
△ Less
Submitted 12 February, 2018;
originally announced February 2018.
-
Dual terahertz comb spectroscopy with a single free-running fibre laser
Authors:
Guoqing Hu,
Tatsuya Mizuguchi,
Ryo Oe,
Kazuki Nitta,
Xin Zhao,
Takeo Minamikawa,
Ting Li,
Zheng Zheng,
Takeshi Yasui
Abstract:
Dual THz comb spectroscopy has the potential to be used as universal THz spectroscopy with high spectral resolution, high spectral accuracy, and broad spectral coverage; however, the requirement for dual stabilized femtosecond lasers hampers its versatility due to the bulky size, high complexity, and high cost. We here report the first demonstration of dual THz comb spectroscopy using a single fre…
▽ More
Dual THz comb spectroscopy has the potential to be used as universal THz spectroscopy with high spectral resolution, high spectral accuracy, and broad spectral coverage; however, the requirement for dual stabilized femtosecond lasers hampers its versatility due to the bulky size, high complexity, and high cost. We here report the first demonstration of dual THz comb spectroscopy using a single free-running fibre laser. By tuning the cavity-loss-dependent gain profile with an intracavity Lyot filter together with precise management of the cavity length and dispersion, dual-wavelength pulsed light beams with slightly detuned repetition frequencies are generated in a single laser cavity. Due to sharing of the same cavity, such pulsed light beams suffer from common-mode fluctuation of the repetition frequency, and hence the corresponding frequency difference between them is passively stable around a few hundred hertz within millihertz fluctuation. This considerably stable frequency difference enables dual THz comb spectroscopy with a single free-running fibre laser. While greatly reducing the size, complexity, and cost of the laser source by use of a single free-running fibre laser, the dual THz comb spectroscopy system maintains a spectral bandwidth and dynamic range of spectral power comparable to a system equipped with dual stabilized fibre lasers, and can be effectively applied to high-precision spectroscopy of acetonitrile gas at atmospheric pressure. The demonstrated results indicate that this system is an attractive solution for practical applications of not only THz spectroscopy but also THz-pulse-based measurements.
△ Less
Submitted 28 January, 2018;
originally announced February 2018.