-
On the use of multilayer Laue lenses with X-ray Free Electron Lasers
Authors:
Mauro Prasciolu,
Kevin T. Murray,
Nikolay Ivanov,
Holger Fleckenstein,
Martin Domaracký,
Luca Gelisio,
Fabian Trost,
Kartik Ayyer,
Dietrich Krebs,
Steve Aplin,
Salah Awel,
Ulrike Boesenberg,
Anton Barty,
Armando D. Estillore,
Matthias Fuchs,
Yaroslav Gevorkov,
Joerg Hallmann,
Chan Kim,
Juraj Knoška,
Jochen Küpper,
Chufeng Li,
Wei Lu,
Valerio Mariani,
Andrew J. Morgan,
Johannes Möller
, et al. (12 additional authors not shown)
Abstract:
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of…
▽ More
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of 3.55 us, was done using the same set of lenses. The increase in the number of pulses per train was accompanied with an increase of x-ray intensity (transmission) from 9% to 92% at 5 pulses per train, and then the transmission was reduced to 23.5 % when the pulses were increased further. The final working condition was 30 pulses per train and 23.5% transmission. Only at this condition we saw that the diffraction efficiency of the MLLs changed over the course of a pulse train, and this variation was reproducible from train to train. We present the procedure to align and characterize these lenses and discuss challenges working with the pulse trains from this unique x-ray source.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Continuous Diffraction of Molecules and Disordered Molecular Crystals
Authors:
Henry N. Chapman,
Oleksandr M. Yefanov,
Kartik Ayyer,
Thomas A. White,
Anton Barty,
Andrew Morgan,
Valerio Mariani,
Dominik Oberthuer,
Kanupriya Pande
Abstract:
The diffraction pattern of a single non-periodic compact object, such as a molecule, is continuous and is proportional to the square modulus of the Fourier transform of that object. When arrayed in a crystal, the coherent sum of the continuous diffracted wave-fields from all objects gives rise to strong Bragg peaks that modulate the single-object transform. Wilson statistics describe the distribut…
▽ More
The diffraction pattern of a single non-periodic compact object, such as a molecule, is continuous and is proportional to the square modulus of the Fourier transform of that object. When arrayed in a crystal, the coherent sum of the continuous diffracted wave-fields from all objects gives rise to strong Bragg peaks that modulate the single-object transform. Wilson statistics describe the distribution of continuous diffraction intensities to the same extent that they apply to Bragg diffraction. The continuous diffraction obtained from translationally-disordered molecular crystals consists of the incoherent sum of the wave-fields from the individual rigid units (such as molecules) in the crystal, which is proportional to the incoherent sum of the diffraction from the rigid units in each of their crystallographic orientations. This sum over orientations modifies the statistics in a similar way that crystal twinning modifies the distribution of Bragg intensities. These statistics are applied to determine parameters of continuous diffraction such as its scaling, the beam coherence, and the number of independent wave-fields or object orientations contributing. Continuous diffraction is generally much weaker than Bragg diffraction and may be accompanied by a background that far exceeds the strength of the signal. Instead of just relying upon the smallest measured intensities to guide the subtraction of the background it is shown how all measured values can be utilised to estimate the background, noise, and signal, by employing a modified "noisy Wilson" distribution that explicitly includes the background. Parameters relating to the background and signal quantities can be estimated from the moments of the measured intensities. The analysis method is demonstrated on previously-published continuous diffraction data measured from imperfect crystals of photosystem II.
△ Less
Submitted 15 May, 2017;
originally announced May 2017.
-
Femtosecond x-ray diffraction from an aerosolized beam of protein nanocrystals
Authors:
Salah Awel,
Richard A. Kirian,
Max O. Wiedorn,
Kenneth R. Beyerlein,
Nils Roth,
Daniel A. Horke,
Dominik Oberthür,
Juraj Knoska,
Valerio Mariani,
Andrew Morgan,
Luigi Adriano,
Alexandra Tolstikova,
P. Lourdu Xavier,
Oleksandr Yefanov,
Andrew Aquila,
Anton Barty,
Shatabdi Roy-Chowdhury,
Mark S. Hunter,
Daniel James,
Joseph S. Robinson,
Uwe Weierstall,
Andrei V. Rode,
Saša Bajt,
Jochen Küpper,
Henry N. Chapman
Abstract:
We demonstrate near-atomic-resolution Bragg diffraction from aerosolized single granulovirus crystals using an x-ray free-electron laser. The form of the aerosol injector is nearly identical to conventional liquid-microjet nozzles, but the x-ray-scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid. This approach provides a route to stu…
▽ More
We demonstrate near-atomic-resolution Bragg diffraction from aerosolized single granulovirus crystals using an x-ray free-electron laser. The form of the aerosol injector is nearly identical to conventional liquid-microjet nozzles, but the x-ray-scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid. This approach provides a route to study the weak diffuse or lattice-transform signal arising from small crystals. The high speed of the particles is particularly well suited to upcoming MHz-repetition-rate x-ray free-electron lasers.
△ Less
Submitted 13 January, 2018; v1 submitted 13 February, 2017;
originally announced February 2017.