-
Interfacial studies in CNT fibre/TiO$_{2}$ photoelectrodes for efficient H$_{2}$ production
Authors:
Alicia Moya,
Mariam Barawi,
Belén Alemán,
Patrick Zeller,
Matteo Amati,
Alfonso Monreal-Bernal,
Luca Gregoratti,
Víctor A. de la Peña O'Shea,
Juan J. Vilatela
Abstract:
An attractive class of materials for photo(electro)chemical reactions are hybrids based on semiconducting metal oxides and nanocarbons (e.g. carbon nanotubes (CNT), graphene), where the nanocarbon acts as a highly-stable conductive scaffold onto which the nanostructured inorganic phase can be immobilised; an architecture that maximises surface area and minimises charge transport/transfer resistanc…
▽ More
An attractive class of materials for photo(electro)chemical reactions are hybrids based on semiconducting metal oxides and nanocarbons (e.g. carbon nanotubes (CNT), graphene), where the nanocarbon acts as a highly-stable conductive scaffold onto which the nanostructured inorganic phase can be immobilised; an architecture that maximises surface area and minimises charge transport/transfer resistance. TiO$_{2}$/CNT photoanodes produced by atomic layer deposition on CNT fabrics are shown to be efficient for H$_{2}$ production ($0.07 μmol/min$ $H_{2}$ at $0.2V$ $vs Ag/AgCl$), nearly doubling the performance of TiO$_{2}$ deposited on planar substrates, with $100 \%$ Faradaic efficiency. The results are rationalised based on electrochemical impedance spectroscopy measurements showing a large reduction in photoelectron transport resistance compared to control samples and a higher surface area. The low TiO$_{2}$/CNT interfacial charge transfer resistance ($10 Ω$) is consistent with the presence of an interfacial Ti-O-C bond and corresponding electronic hybridisation determined by spatially-resolved Scanning Photoelectron Microscopy (SPEM) using synchrotron radiation.
△ Less
Submitted 2 December, 2020;
originally announced December 2020.
-
Quantifying the Performance of a Hybrid Pixel Detector with GaAs:Cr Sensor for Transmission Electron Microscopy
Authors:
Kirsty A. Paton,
Matthew C. Veale,
Xiaoke Mu,
Christopher S. Allen,
Dzmitry Maneuski,
Christian Kübel,
Val O'Shea,
Angus I. Kirkland,
Damien McGrouther
Abstract:
Hybrid pixel detectors (HPDs) have been shown to be highly effective for diffraction-based and time-resolved studies in transmission electron microscopy, but their performance is limited by the fact that high-energy electrons scatter over long distances in their thick Si sensors. An advantage of HPDs compared to monolithic active pixel sensors (MAPS) is that their sensor does not need to be fabric…
▽ More
Hybrid pixel detectors (HPDs) have been shown to be highly effective for diffraction-based and time-resolved studies in transmission electron microscopy, but their performance is limited by the fact that high-energy electrons scatter over long distances in their thick Si sensors. An advantage of HPDs compared to monolithic active pixel sensors (MAPS) is that their sensor does not need to be fabricated from Si. We have compared the performance of the Medipix3 HPD with a Si sensor and with a GaAs:Cr sensor using primary electrons in the energy range of 60 - 300keV. We describe the measurement and calculation of the detectors' modulation transfer function (MTF) and detective quantum efficiency (DQE), which show that the performance of the GaAs:Cr device is markedly superior to that of the Si device for high-energy electrons.
△ Less
Submitted 30 September, 2020;
originally announced September 2020.
-
Sub-100 nanosecond temporally resolved imaging with the Medipix3 direct electron detector
Authors:
Gary W. Paterson,
Raymond J. Lamb,
Rafael Ballabriga,
Dima Maneuski,
Val O'Shea,
Damien McGrouther
Abstract:
Detector developments are currently enabling new capabilities in the field of transmission electron microscopy (TEM). We have investigated the limits of a hybrid pixel detector, Medipix3, to record dynamic, time varying, electron signals. Operating with an energy of 60keV, we have utilised electrostatic deflection to oscillate electron beam position on the detector. Adopting a pump-probe imaging s…
▽ More
Detector developments are currently enabling new capabilities in the field of transmission electron microscopy (TEM). We have investigated the limits of a hybrid pixel detector, Medipix3, to record dynamic, time varying, electron signals. Operating with an energy of 60keV, we have utilised electrostatic deflection to oscillate electron beam position on the detector. Adopting a pump-probe imaging strategy we have demonstrated that temporal resolutions three orders of magnitude smaller than are available for typically used TEM imaging detectors are possible. Our experiments have shown that energy deposition of the primary electrons in the hybrid pixel detector limits the overall temporal resolution. Through adjustment of user specifiable thresholds or the use of charge summing mode, we have obtained images composed from summing 10,000s frames containing single electron events to achieve temporal resolution less than 100ns. We propose that this capability can be directly applied to studying repeatable material dynamic processes but also to implement low-dose imaging schemes in scanning transmission electron microscopy.
△ Less
Submitted 11 November, 2019; v1 submitted 28 May, 2019;
originally announced May 2019.
-
Medipix3 Demonstration and understanding of near ideal detector performance for 60 & 80 keV electrons
Authors:
J. A. Mir,
R. Clough,
R. MacInnes,
C. Gough,
R. Plackett,
I. Shipsey,
H. Sawada,
I. MacLaren,
R. Ballabriga,
D. Maneuski,
V. O'Shea,
D. McGrouther,
A. I. Kirkland
Abstract:
In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize…
▽ More
In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize either the MTF or DQE, obtaining values near to, or even exceeding, those for an ideal detector. We have demonstrated that the Medipix3 charge summing mode (CSM) can deliver simultaneous, near ideal values of both MTF and DQE. To understand direct detection performance further we have characterized the detector response to single electron events, building an empirical model which can predict detector MTF and DQE performance based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance, recording a fully exposed electron diffraction pattern at 24-bit depth and images in SPM and CSM modes. Taken together our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous and alternative architecture for direct electron imaging
△ Less
Submitted 26 August, 2016;
originally announced August 2016.
-
Diffractive triangulation of radiative point sources
Authors:
Stefano Vespucci,
Carol Trager-Cowan,
Dzmitry Maneuski,
Val O'Shea,
Aimo Winkelmann
Abstract:
We describe a general method to determine the location of a point source of waves relative to a two-dimensional active pixel detector. Based on the inherent structural sensitivity of crystalline sensor materials, characteristic detector diffraction patterns can be used to triangulate the location of a wave emitter. As a practical application of the wide-ranging principle, a digital hybrid pixel de…
▽ More
We describe a general method to determine the location of a point source of waves relative to a two-dimensional active pixel detector. Based on the inherent structural sensitivity of crystalline sensor materials, characteristic detector diffraction patterns can be used to triangulate the location of a wave emitter. As a practical application of the wide-ranging principle, a digital hybrid pixel detector is used to localize a source of electrons for Kikuchi diffraction pattern measurements in the scanning electron microscope. This provides a method to calibrate Kikuchi diffraction patterns for accurate measurements of microstructural crystal orientations, strains, and phase distributions.
△ Less
Submitted 17 July, 2016;
originally announced July 2016.
-
Search for neutral Higgs bosons decaying into four taus at LEP2
Authors:
ALEPH Collaboration,
S. Schael,
R. Barate,
R. Brunelière,
I. De Bonis,
D. Decamp,
C. Goy,
S. Jézéquel,
J. -P. Lees,
F. Martin,
E. Merle,
M. -N. Minard,
B. Pietrzyk,
B. Trocmé S. Bravo,
M. P. Casado,
M. Chmeissani,
J. M. Crespo,
E. Fernandez,
M. Fernandez-Bosman,
Ll. Garrido,
M. Martinez,
A. Pacheco,
H. Ruiz,
A. Colaleo,
D. Creanza
, et al. (236 additional authors not shown)
Abstract:
A search for the production and non-standard decay of a Higgs boson, h, into four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of data collected by the ALEPH experiment at centre-of-mass energies from 183 to 209 GeV. No excess of events above background is observed, and exclusion limits are placed on the combined production cross section times branching ratio, ξ^2 = σ(e+e…
▽ More
A search for the production and non-standard decay of a Higgs boson, h, into four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of data collected by the ALEPH experiment at centre-of-mass energies from 183 to 209 GeV. No excess of events above background is observed, and exclusion limits are placed on the combined production cross section times branching ratio, ξ^2 = σ(e+e- --> Zh)/σ_{SM}(e+e- --> Zh) x B(h --> aa)x B(a --> τ^+τ^-)^2. For mh < 107 GeV/c2 and 4 < ma < 10 GeV/c2, ξ^2 > 1 is excluded at the 95% confidence level.
△ Less
Submitted 19 April, 2010; v1 submitted 2 March, 2010;
originally announced March 2010.
-
The LCFIVertex package: vertexing, flavour tagging and vertex charge reconstruction with an ILC vertex detector
Authors:
LCFI Collaboration,
David Bailey,
Erik Devetak,
Mark Grimes,
Kristian Harder,
Sonja Hillert,
David Jackson,
Talini Pinto Jayawardena,
Ben Jeffery,
Tomas Lastovicka,
Clare Lynch,
Victoria Martin,
Roberval Walsh,
Phil Allport,
Yambazi Banda,
Craig Buttar,
Alexandre Cheplakov,
David Cussans,
Chris Damerell,
Nicolo de Groot,
Johan Fopma,
Brian Foster,
Senerath Galagedera,
Rui Gao,
Anthony Gillman
, et al. (36 additional authors not shown)
Abstract:
The precision measurements envisaged at the International Linear Collider (ILC) depend on excellent instrumentation and reconstruction software. The correct identification of heavy flavour jets, placing unprecedented requirements on the quality of the vertex detector, will be central for the ILC programme. This paper describes the LCFIVertex software, which provides tools for vertex finding and…
▽ More
The precision measurements envisaged at the International Linear Collider (ILC) depend on excellent instrumentation and reconstruction software. The correct identification of heavy flavour jets, placing unprecedented requirements on the quality of the vertex detector, will be central for the ILC programme. This paper describes the LCFIVertex software, which provides tools for vertex finding and for identification of the flavour and charge of the leading hadron in heavy flavour jets. These tools are essential for the ongoing optimisation of the vertex detector design for linear colliders such as the ILC. The paper describes the algorithms implemented in the LCFIVertex package, as well as the scope of the code and its performance for a typical vertex detector design.
△ Less
Submitted 20 August, 2009;
originally announced August 2009.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.
-
The FP420 R&D Project: Higgs and New Physics with forward protons at the LHC
Authors:
M. G. Albrow,
R. B. Appleby,
M. Arneodo,
G. Atoian,
I. L. Azhgirey,
R. Barlow,
I. S. Bayshev,
W. Beaumont,
L. Bonnet,
A. Brandt,
P. Bussey,
C. Buttar,
J. M. Butterworth,
M. Carter,
B. E. Cox,
D. Dattola,
C. Da Via,
J. de Favereau,
D. d'Enterria,
P. De Remigis,
A. De Roeck,
E. A. De Wolf,
P. Duarte,
J. R. Ellis,
B. Florins
, et al. (73 additional authors not shown)
Abstract:
We present the FP420 R&D project, which has been studying the key aspects of the development and installation of a silicon tracker and fast-timing detectors in the LHC tunnel at 420 m from the interaction points of the ATLAS and CMS experiments. These detectors would measure precisely very forward protons in conjunction with the corresponding central detectors as a means to study Standard Model…
▽ More
We present the FP420 R&D project, which has been studying the key aspects of the development and installation of a silicon tracker and fast-timing detectors in the LHC tunnel at 420 m from the interaction points of the ATLAS and CMS experiments. These detectors would measure precisely very forward protons in conjunction with the corresponding central detectors as a means to study Standard Model (SM) physics, and to search for and characterise New Physics signals. This report includes a detailed description of the physics case for the detector and, in particular, for the measurement of Central Exclusive Production, pp --> p + phi + p, in which the outgoing protons remain intact and the central system phi may be a single particle such as a SM or MSSM Higgs boson. Other physics topics discussed are gamma-gamma and gamma-p interactions, and diffractive processes. The report includes a detailed study of the trigger strategy, acceptance, reconstruction efficiencies, and expected yields for a particular p p --> p H p measurement with Higgs boson decay in the b-bbar mode. The document also describes the detector acceptance as given by the LHC beam optics between the interaction points and the FP420 location, the machine backgrounds, the new proposed connection cryostat and the moving ("Hamburg") beam-pipe at 420 m, and the radio-frequency impact of the design on the LHC. The last part of the document is devoted to a description of the 3D silicon sensors and associated tracking performances, the design of two fast-timing detectors capable of accurate vertex reconstruction for background rejection at high-luminosities, and the detector alignment and calibration strategy.
△ Less
Submitted 2 January, 2009; v1 submitted 2 June, 2008;
originally announced June 2008.
-
Analysis of trap spectra in LEC and epitaxial GaAs
Authors:
J. Vaitkus,
E. Gaubas,
V. Kazukauskas,
V. Rinkevicius,
J. Storasta,
R. Tomasiunas,
K. M. Smith,
V. O'Shea
Abstract:
Different methods of trap parameter measurement are analysed. Transient photoconductivity and thermally stimulated effects were used to investigate the influence of traps in LEC SI-GaAs and high resistivity epitaxial GaAs. The peculiarities of the TSC were analysed and shown to be related to the influence of crystal micro-inhomogeneities.
Different methods of trap parameter measurement are analysed. Transient photoconductivity and thermally stimulated effects were used to investigate the influence of traps in LEC SI-GaAs and high resistivity epitaxial GaAs. The peculiarities of the TSC were analysed and shown to be related to the influence of crystal micro-inhomogeneities.
△ Less
Submitted 30 November, 1999;
originally announced November 1999.
-
Preliminary Results for LP VPE X-Ray Detectors
Authors:
R. Adams,
R. Bates,
C. Da Via,
N. P. Johnson,
V. O'Shea,
A. Pickford,
C. Raine,
K. Smith
Abstract:
Thick epitaxial layers have been grown using Low Pressure Vapour Phase Epitaxy techniques with low free carrier concentrations . This type of material is attractive as a medium for X-ray detection, because of its high conversion efficiency for X-rays in the medically interesting energy range.
Thick epitaxial layers have been grown using Low Pressure Vapour Phase Epitaxy techniques with low free carrier concentrations . This type of material is attractive as a medium for X-ray detection, because of its high conversion efficiency for X-rays in the medically interesting energy range.
△ Less
Submitted 24 September, 1997;
originally announced September 1997.
-
Radiation Induced Damage in GaAs Particle Detectors
Authors:
R. L. Bates,
C. Da'Via,
V. O'Shea,
A. Pickford,
C. Raine,
K. M. Smith
Abstract:
The motivation for investigating the use of GaAs as a material for detecting particles in experiments for High Energy Physics (HEP) arose from its perceived resistance to radiation damage. This is a vital requirement for detector materials that are to be used in experiments at future accelerators where the radiation environments would exclude all but the most radiation resistant of detector type…
▽ More
The motivation for investigating the use of GaAs as a material for detecting particles in experiments for High Energy Physics (HEP) arose from its perceived resistance to radiation damage. This is a vital requirement for detector materials that are to be used in experiments at future accelerators where the radiation environments would exclude all but the most radiation resistant of detector types.
△ Less
Submitted 24 September, 1997;
originally announced September 1997.
-
Recent results on GaAs detectors - 137
Authors:
R. L. Bates,
M. Campbell,
C. Da'Via,
S. D'Auria,
V. O'Shea,
C. Raine,
K. M. Smith
Abstract:
The present understanding of the charge collection in GaAs detectors with respect to the materials used and its processing are discussed. The radiation induced degradation of the charge collection efficiency and the leakage current of the detectors are summarised. The status of strip and pixel detectors for the ATLAS experiment are reported along with the latest results from GaAs X-ray detectors…
▽ More
The present understanding of the charge collection in GaAs detectors with respect to the materials used and its processing are discussed. The radiation induced degradation of the charge collection efficiency and the leakage current of the detectors are summarised. The status of strip and pixel detectors for the ATLAS experiment are reported along with the latest results from GaAs X-ray detectors for non-high energy physics applications.
△ Less
Submitted 28 August, 1997;
originally announced August 1997.
-
The effects of radiation on Gallium Arsenide radiation detectors
Authors:
R. L. Bates,
C. Da'Via,
S. D'Auria,
V. O'Shea,
C. Raine,
K. M. Smith
Abstract:
Semi-insulating, undoped, Liquid Encapsulated Czochralski (SI-U LEC) GaAs detectors have been irradiated with 1MeV neutrons, 24GeV/c protons, and 300MeV/c pions. The maximum fluences used were 6, 3, and 1.8~10$^{14}$ particles/cm$^{2}$ respectively. For all three types of irradiation the charge collection efficiencies (cce) of the detector are reduced due to the reduction in the electron and hol…
▽ More
Semi-insulating, undoped, Liquid Encapsulated Czochralski (SI-U LEC) GaAs detectors have been irradiated with 1MeV neutrons, 24GeV/c protons, and 300MeV/c pions. The maximum fluences used were 6, 3, and 1.8~10$^{14}$ particles/cm$^{2}$ respectively. For all three types of irradiation the charge collection efficiencies (cce) of the detector are reduced due to the reduction in the electron and hole mean free paths. Pion and proton irradiations produce a greater reduction in cce than neutron irradiation with the pions having the greatest effect. The effect of annealing the detectors at room temperature, at 200$^{o}$C and at 450$^{o}$C with a flash lamp have been shown to reduce the leakage current and increase the cce of the irradiated detectors. The flash-lamp anneal produced the greatest increase in the cce from 26% to 70% by increasing the mean free path of the electrons. Two indium-doped samples were irradiated with 24GeV/c protons and demonstrated no improvement over SI U GaAs with respect to post-irradiation cce.
△ Less
Submitted 28 August, 1997;
originally announced August 1997.
-
Characterisation of low pressure VPE GaAs diodes before and after 24 GeV/c proton irradiation
Authors:
R. L. Bates,
C. Da'Via,
V. O'Shea,
C. Raine,
K. M. Smith,
R. Adams
Abstract:
GaAs Schottky diode detectors have been fabricated upon Low Pressure Vapour Phase Epitaxial GaAs. The devices were characterised before and after a $1.25 \times 10^{14}$~cm$^{-2}$ 24GeV/c proton fluence. The as fabricated Ti-GaAs barrier height was measured, via two electrical methods, to be $0.81\pm0.005$ and $0.85\pm0.01$~eV and a space charge density of $2.8 \pm 0.2 \times 10^{14}$~cm$^{-3}$…
▽ More
GaAs Schottky diode detectors have been fabricated upon Low Pressure Vapour Phase Epitaxial GaAs. The devices were characterised before and after a $1.25 \times 10^{14}$~cm$^{-2}$ 24GeV/c proton fluence. The as fabricated Ti-GaAs barrier height was measured, via two electrical methods, to be $0.81\pm0.005$ and $0.85\pm0.01$~eV and a space charge density of $2.8 \pm 0.2 \times 10^{14}$~cm$^{-3}$ was determined. The current was greater than that expected for an ideal barrier with the excess attributed to generation current from the bulk. The charge collection efficiency, determined from front alpha illumination and 60 keV gamma irradiation, was inexcess of 95% at 50V reverse bias. After irradiation the reverse current, measured for a bias of 200V at 20$^{o}$~C, increased from 90~nA to 1500~nA due to radiation induced generation centres. Deep levels were showed to be present using capacitance techniques. The charge collection of the device determined from front alpha illumination fell to $32\pm5$% at a reverse bias of 200V.
△ Less
Submitted 28 August, 1997;
originally announced August 1997.