-
Automatic Identification of Edge Localized Modes in the DIII-D Tokamak
Authors:
Finn H. O'Shea,
Semin Joung,
David R. Smith,
Ryan Coffee
Abstract:
Fusion power production in tokamaks uses discharge configurations that risk producing strong Type I Edge Localized Modes. The largest of these modes will likely increase impurities in the plasma and potentially damage plasma facing components such as the protective heat and waste divertor. Machine learning-based prediction and control may provide for online mitigation of these damaging modes befor…
▽ More
Fusion power production in tokamaks uses discharge configurations that risk producing strong Type I Edge Localized Modes. The largest of these modes will likely increase impurities in the plasma and potentially damage plasma facing components such as the protective heat and waste divertor. Machine learning-based prediction and control may provide for online mitigation of these damaging modes before they grow too large to suppress. To that end, large labeled datasets are required for supervised training of machine learning models. We present an algorithm that achieves 97.7% precision when automatically labeling Edge Localized Modes in the large DIII-D tokamak discharge database. The algorithm has no user controlled parameters and is largely robust to tokamak and plasma configuration changes. This automatically-labeled database of events can subsequently feed future training of machine learning models aimed at autonomous Edge Localized Mode control and suppression.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
At-the-edge Data Processing for Low Latency High Throughput Machine Learning Algorithms
Authors:
Jack Hirschman,
Andrei Kamalov,
Razib Obaid,
Finn H. O'Shea,
Ryan N Coffee
Abstract:
High throughput and low latency data processing is essential for systems requiring live decision making, control, and machine learning-optimized data reduction. We focus on two distinct use cases for in-flight streaming data processing for a) X-ray pulse reconstruction at SLAC's LCLS-II Free-Electron Laser and b) control diagnostics at the DIII-D tokamak fusion reactor. Both cases exemplify high t…
▽ More
High throughput and low latency data processing is essential for systems requiring live decision making, control, and machine learning-optimized data reduction. We focus on two distinct use cases for in-flight streaming data processing for a) X-ray pulse reconstruction at SLAC's LCLS-II Free-Electron Laser and b) control diagnostics at the DIII-D tokamak fusion reactor. Both cases exemplify high throughput and low latency control feedback and motivate our focus on machine learning at the edge where data processing and machine learning algorithms can be implemented in field programmable gate array based hardware immediately after the diagnostic sensors. We present our recent work on a data preprocessing chain which requires fast featurization for information encoding. We discuss several options for such algorithms with the primary focus on our discrete cosine and sine transform-based approach adapted for streaming data. These algorithms are primarily aimed at implementation in field programmable gate arrays, favoring linear algebra operations that are also aligned with the recent advances in inference accelerators for the computational edge.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
Beam-based RF Station Fault Identification at the SLAC Linac Coherent Light Source
Authors:
Ryan Humble,
Finn H. O'Shea,
William Colocho,
Matt Gibbs,
Helen Chaffee,
Eric Darve,
Daniel Ratner
Abstract:
Accelerators produce too many signals for a small operations team to monitor in real time. In addition, many of these signals are only interpretable by subject matter experts with years of experience. As a result, changes in accelerator performance can require time-intensive consultations with experts to identify the underlying problem. Herein, we focus on a particular anomaly detection task for r…
▽ More
Accelerators produce too many signals for a small operations team to monitor in real time. In addition, many of these signals are only interpretable by subject matter experts with years of experience. As a result, changes in accelerator performance can require time-intensive consultations with experts to identify the underlying problem. Herein, we focus on a particular anomaly detection task for radio-frequency (RF) stations at the Linac Coherent Light Source (LCLS). The existing RF station diagnostics are bandwidth limited, resulting in slow, unreliable signals. As a result, anomaly detection is currently a manual process. We propose a beam-based method, identifying changes in the accelerator status using shot-to-shot data from the beam position monitoring system; by comparing the beam-based anomalies to data from RF stations, we identify the source of the change. We find that our proposed method can be fully automated while identifying more events with fewer false positives than the RF station diagnostics alone. Our automated fault identification system has been used to create a new data set for investigating the interaction between the RF stations and accelerator performance.
△ Less
Submitted 2 November, 2022; v1 submitted 9 June, 2022;
originally announced June 2022.
-
Tracking Attosecond Electronic Coherences Using Phase-Manipulated Extreme Ultraviolet Pulses
Authors:
Andreas Wituschek,
Lukas Bruder,
Enrico Allaria,
Ulrich Bangert,
Marcel Binz,
Carlo Callegari,
Giulio Cerullo,
Paolo Cinquegrana,
Luca Gianessi,
Miltcho Danailov,
Alexander Demidovich,
Michele Di Fraia,
Marcel Drabbels,
Raimund Feifel,
Tim Laarmann,
Rupert Michiels,
Najmeh Sadat Mirian,
Marcel Mudrich,
Ivaylo Nikolov,
Finn H. O'Shea,
Giuseppe Penco,
Paolo Piseri,
Oksana Plekan,
Kevin Charles Prince,
Andreas Przystawik
, et al. (9 additional authors not shown)
Abstract:
The recent development of ultrafast extreme ultraviolet (XUV) coherent light sources bears great potential for a better understanding of the structure and dynamics of matter. Promising routes are advanced coherent control and nonlinear spectroscopy schemes in the XUV energy range, yielding unprecedented spatial and temporal resolution. However, their implementation has been hampered by the experim…
▽ More
The recent development of ultrafast extreme ultraviolet (XUV) coherent light sources bears great potential for a better understanding of the structure and dynamics of matter. Promising routes are advanced coherent control and nonlinear spectroscopy schemes in the XUV energy range, yielding unprecedented spatial and temporal resolution. However, their implementation has been hampered by the experimental challenge of generating XUV pulse sequences with precisely controlled timing and phase properties. In particular, direct control and manipulation of the phase of individual pulses within a XUV pulse sequence opens exciting possibilities for coherent control and multidimensional spectroscopy, but has not been accomplished. Here, we overcome these constraints in a highly time-stabilized and phase-modulated XUV-pump, XUV-probe experiment, which directly probes the evolution and dephasing of an inner subshell electronic coherence. This approach, avoiding any XUV optics for direct pulse manipulation, opens up extensive applications of advanced nonlinear optics and spectroscopy at XUV wavelengths.
△ Less
Submitted 2 November, 2020; v1 submitted 17 June, 2019;
originally announced June 2019.
-
Demonstration of single-shot picosecond time-resolved MeV electron imaging using a compact permanent magnet quadrupole based lens
Authors:
D. Cesar,
J. Maxson,
P. Musumeci,
Y. Sun,
J. Harrison,
P. Frigola,
F. H. O'Shea,
H. To,
D. Alesini,
R. K. Li
Abstract:
We present the results of an experiment where a short focal length (~ 1.3 cm) permanent magnet electron lens is used to image micron-size features of a metal sample in a single shot, using an ultra- high brightness ps-long 4 MeV electron beam from a radiofrequency photoinjector. Magnifcation ratios in excess of 30x were obtained using a triplet of compact, small gap (3.5 mm), Halbach-style permane…
▽ More
We present the results of an experiment where a short focal length (~ 1.3 cm) permanent magnet electron lens is used to image micron-size features of a metal sample in a single shot, using an ultra- high brightness ps-long 4 MeV electron beam from a radiofrequency photoinjector. Magnifcation ratios in excess of 30x were obtained using a triplet of compact, small gap (3.5 mm), Halbach-style permanent magnet quadrupoles with nearly 600 T/m field gradients. These results pave the way to- wards single shot time-resolved electron microscopy and open new opportunities in the applications of high brightness electron beams.
△ Less
Submitted 4 April, 2016;
originally announced April 2016.