-
Axion Dark Matter eXperiment: Run 1A Analysis Details
Authors:
C. Boutan,
B. H. LaRoque,
E. Lentz,
N. S. Oblath,
M. S. Taubman,
J. Tedeschi,
J. Yang,
A. M. Jones,
T. Braine,
N. Crisosto,
L. J Rosenberg,
G. Rybka,
D. Will,
D. Zhang,
S. Kimes,
R. Ottens,
C. Bartram,
D. Bowring,
R. Cervantes,
A. S. Chou,
S. Knirck,
D. V. Mitchell,
A. Sonnenschein,
W. Wester,
R. Khatiwada
, et al. (28 additional authors not shown)
Abstract:
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower…
▽ More
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Two-Level Systems in Nucleated and Non-Nucleated Epitaxial alpha-Tantalum films
Authors:
L. D. Alegria,
D. M. Tennant,
K. R. Chaves,
J. R. I. Lee,
S. R. O'Kelley,
Y. J. Rosen,
J L DuBois
Abstract:
Building usefully coherent superconducting quantum processors depends on reducing losses in their constituent materials. Tantalum, like niobium, has proven utility as the primary superconducting layer within highly coherent qubits. But, unlike Nb, high temperatures are typically used to stabilize the desirable body-centered-cubic phase, alpha-Ta, during thin film deposition. It has long been known…
▽ More
Building usefully coherent superconducting quantum processors depends on reducing losses in their constituent materials. Tantalum, like niobium, has proven utility as the primary superconducting layer within highly coherent qubits. But, unlike Nb, high temperatures are typically used to stabilize the desirable body-centered-cubic phase, alpha-Ta, during thin film deposition. It has long been known that a thin Nb layer permits the room-temperature nucleation of alpha-Ta, although neither an epitaxial process nor few-photon microwave loss measurements have been reported for Nb-nucleated Ta films prior to this study. We compare resonators patterned from Ta films grown at high temperature (500 °C) and films nucleated at room temperature, in order to understand the impact of crystalline order on quantum coherence. In both cases, films grew with Al2O3 (001) || Ta (110) indicating that the epitaxial orientation is independent of temperature and is preserved across the Nb/Ta interface. We use conventional low-power spectroscopy to measure two level system (TLS) loss, as well as an electric-field bias technique to measure the effective dipole moments of TLS in the surfaces of resonators. In our measurements, Nb-nucleated Ta resonators had greater loss tangent (1.5 +/- 0.1 x 10^-5) than non-nucleated (5 +/- 1 x 10^-6) in approximate proportion to defect densities as characterized by X-ray diffraction (0.27 ° vs 0.18 ° [110] reflection width) and electron microscopy (30 nm vs 70 nm domain size). The dependence of the loss tangent on domain size indicates that the development of more ordered Ta films is likely to lead to improvements in qubit coherence times. Moreover, low-temperature alpha-Ta epitaxy may enable the growth of new, microstate-free heterostructures which would not withstand high temperature processing.
△ Less
Submitted 18 September, 2023; v1 submitted 24 January, 2023;
originally announced January 2023.
-
Low frequency correlated charge noise measurements across multiple energy transitions in a tantalum transmon
Authors:
Daniel M. Tennant,
Luis A. Martinez,
Kristin M. Beck,
Sean R. O'Kelley,
Christopher D. Wilen,
R. McDermott,
Jonathan L DuBois,
Yaniv J. Rosen
Abstract:
Transmon qubits fabricated with tantalum metal have been shown to possess energy relaxation times greater than 300 $μ$s and, as such, present an attractive platform for high precision, correlated noise studies across multiple higher energy transitions. Tracking the multi-level fluctuating qudit frequencies with a precision enabled by the high coherence of the device allows us to extract the charge…
▽ More
Transmon qubits fabricated with tantalum metal have been shown to possess energy relaxation times greater than 300 $μ$s and, as such, present an attractive platform for high precision, correlated noise studies across multiple higher energy transitions. Tracking the multi-level fluctuating qudit frequencies with a precision enabled by the high coherence of the device allows us to extract the charge offset and quasi-particle dynamics. We observe qualitatively different charge offset behavior in the tantalum device than those measured in previous low frequency charge noise studies. In particular, we find the charge offset dynamics are dominated by rare, discrete jumps between a finite number of quasi-stationary charge configurations, a previously unobserved charge noise process in superconducting qubits.
△ Less
Submitted 29 November, 2021; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Axion Dark Matter eXperiment: Run 1B Analysis Details
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
M. Goryachev,
B. McAllister,
M. E. Tobar,
C. Boutan,
M. Jones,
B. H. Laroque,
N. S. Oblath
, et al. (23 additional authors not shown)
Abstract:
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire fre…
▽ More
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for Run 1B, motivating analysis choices informed by details specific to this run.
△ Less
Submitted 13 October, 2020;
originally announced October 2020.
-
Axion Dark Matter eXperiment: Detailed Design and Operations
Authors:
R. Khatiwada,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
D. V. Mitchell,
T. Braine,
C. Bartram,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Will,
G. Carosi,
N. Woollett,
S. Durham,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath
, et al. (26 additional authors not shown)
Abstract:
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technolog…
▽ More
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.
△ Less
Submitted 30 September, 2020;
originally announced October 2020.
-
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
Authors:
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
M. S. Taubman,
J. Clarke,
A. Dove,
A. Eddins
, et al. (17 additional authors not shown)
Abstract:
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode c…
▽ More
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.
△ Less
Submitted 1 November, 2019; v1 submitted 18 October, 2019;
originally announced October 2019.
-
Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter
Authors:
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
R. Cervantes,
N. Du,
N. Force,
S. Kimes,
R. Ottens,
L. J. Rosenberg,
G. Rybka,
J. Yang,
G. Carosi,
N. Woollett,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
R. Bradley,
E. J. Daw,
A. Agrawal,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley
, et al. (9 additional authors not shown)
Abstract:
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, highe…
▽ More
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
A Search for Invisible Axion Dark Matter with the Axion Dark Matter Experiment
Authors:
N. Du,
N. Force,
R. Khatiwada,
E. Lentz,
R. Ottens,
L. J Rosenberg,
G. Rybka,
G. Carosi,
N. Woolett,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
C. Boutan,
N. S. Oblath,
R. Bradley,
E. J. Daw,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley,
N. Crisosto,
J. R. Gleason,
S. Jois,
P. Sikivie,
I. Stern
, et al. (3 additional authors not shown)
Abstract:
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from t…
▽ More
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultra-low-noise SQUID amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.
△ Less
Submitted 17 April, 2018; v1 submitted 16 April, 2018;
originally announced April 2018.
-
Pure dephasing in flux qubits due to flux noise with spectral density scaling as $1/ f^α$
Authors:
S. M. Anton,
C. Müller,
J. S. Birenbaum,
S. R. O'Kelley,
A. D. Fefferman,
D. S. Golubev,
G. C. Hilton,
H. -M. Cho,
K. D. Irwin,
F. C. Wellstood,
Gerd Schön,
A. Shnirman,
John Clarke
Abstract:
For many types of superconducting qubits, magnetic flux noise is a source of pure dephasing. Measurements on a representative dc superconducting quantum interference device (SQUID) over a range of temperatures show that $S_Φ(f) = A^2/(f/1 \hbox{Hz})^α$, where $S_Φ$ is the flux noise spectral density, $A$ is of the order of 1 $μΦ_0 \, \hbox{Hz}^{-1/2}$ and $0.61 \leq α\leq 0.95$; $Φ_{0}$ is the flu…
▽ More
For many types of superconducting qubits, magnetic flux noise is a source of pure dephasing. Measurements on a representative dc superconducting quantum interference device (SQUID) over a range of temperatures show that $S_Φ(f) = A^2/(f/1 \hbox{Hz})^α$, where $S_Φ$ is the flux noise spectral density, $A$ is of the order of 1 $μΦ_0 \, \hbox{Hz}^{-1/2}$ and $0.61 \leq α\leq 0.95$; $Φ_{0}$ is the flux quantum. For a qubit with an energy level splitting linearly coupled to the applied flux, calculations of the dependence of the pure dephasing time $τ_φ$ of Ramsey and echo pulse sequences on $α$ for fixed $A$ show that $τ_φ$ decreases rapidly as $α$ is reduced. We find that $τ_φ$ is relatively insensitive to the noise bandwidth, $f_1 \leq f \leq f_2$, for all $α$ provided the ultraviolet cutoff frequency $f_2 > 1/τ_φ$. We calculate the ratio $τ_{φ,E} / τ_{φ,R}$ of the echo ($E$) and Ramsey ($R$) sequences, and the dependence of the decay function on $α$ and $f_2$. We investigate the case in which $S_Φ(f_0)$ is fixed at the "pivot frequency" $f_0 \neq 1$ Hz while $α$ is varied, and find that the choice of $f_0$ can greatly influence the sensitivity of $τ_{φ,E}$ and $τ_{φ,R}$ to the value of $α$. Finally, we present calculated values of $τ_φ$ in a qubit corresponding to the values of $A$ and $α$ measured in our SQUID.
△ Less
Submitted 16 February, 2012; v1 submitted 30 November, 2011;
originally announced November 2011.