Skip to main content

Showing 1–14 of 14 results for author: Ntziachristos, V

.
  1. arXiv:2207.13978  [pdf

    eess.IV physics.med-ph

    Spotlight on nerves: Portable multispectral optoacoustic imaging of peripheral nerve vascularization and morphology

    Authors: Dominik Jüstel, Hedwig Irl, Florian Hinterwimmer, Christoph Dehner, Walter Simson, Nassir Navab, Gerhard Schneider, Vasilis Ntziachristos

    Abstract: Various morphological and functional parameters of peripheral nerves and their vascular supply are indicative of pathological changes due to injury or disease. Based on recent improvements in optoacoustic image quality, we explore the ability of multispectral optoacoustic tomography, in tandem with ultrasound imaging (OPUS), to investigate the vascular environment and morphology of peripheral nerv… ▽ More

    Submitted 28 July, 2022; originally announced July 2022.

  2. arXiv:2206.14485  [pdf

    eess.IV

    DeepMB: Deep neural network for real-time optoacoustic image reconstruction with adjustable speed of sound

    Authors: Christoph Dehner, Guillaume Zahnd, Vasilis Ntziachristos, Dominik Jüstel

    Abstract: Multispectral optoacoustic tomography (MSOT) is a high-resolution functional imaging modality that can non-invasively access a broad range of pathophysiological phenomena by quantifying the contrast of endogenous chromophores in tissue. Real-time imaging is imperative to translate MSOT into clinical imaging, visualize dynamic pathophysiological changes associated with disease progression, and enab… ▽ More

    Submitted 11 April, 2023; v1 submitted 29 June, 2022; originally announced June 2022.

  3. arXiv:2203.06011  [pdf

    physics.med-ph

    Enabling the autofocus approach for parameter optimization in planar measurement geometry clinical optoacoustic imaging

    Authors: Ludwig Englert, Lucas Riobo, Christine Schonemann, Vasilis Ntziachristos, Juan Aguirre

    Abstract: In optoacoustic (photoacoustic) tomography, several parameters related to tissue and detector features are needed for image formation, but they may not be known a priori. An autofocus (AF) algorithm is generally used to estimate these parameters. However, the algorithm works iteratively, therefore, it is impractical for clinical imaging with systems featuring planar geometry due to long reconstruc… ▽ More

    Submitted 11 March, 2022; originally announced March 2022.

    Comments: 12 pages, 3 figures

  4. arXiv:2108.02798  [pdf

    eess.IV cs.CV cs.LG

    Self-Supervised Learning from Unlabeled Fundus Photographs Improves Segmentation of the Retina

    Authors: Jan Kukačka, Anja Zenz, Marcel Kollovieh, Dominik Jüstel, Vasilis Ntziachristos

    Abstract: Fundus photography is the primary method for retinal imaging and essential for diabetic retinopathy prevention. Automated segmentation of fundus photographs would improve the quality, capacity, and cost-effectiveness of eye care screening programs. However, current segmentation methods are not robust towards the diversity in imaging conditions and pathologies typical for real-world clinical applic… ▽ More

    Submitted 5 August, 2021; originally announced August 2021.

  5. arXiv:2104.14966  [pdf

    eess.IV eess.SP physics.optics

    Disentangling the frequency content in optoacoustics

    Authors: Antonia Longo, Dominik Jüstel, Vasilis Ntziachristos

    Abstract: Signals acquired by optoacoustic tomography systems have broadband frequency content that encodes information about structures on different physical scales. Concurrent processing and rendering of such broadband signals may result in images with poor contrast and fidelity due to a bias towards low frequency contributions from larger structures. This problem cannot be addressed by filtering differen… ▽ More

    Submitted 29 April, 2021; originally announced April 2021.

    Comments: 28 pages, 5 figures, 1 supplemental figure

  6. arXiv:2104.06465  [pdf

    physics.optics physics.bio-ph

    Elongated focus optoacoustic microscopy with matched Bessel beam illumination and ultra-broadband axicon detection

    Authors: Zakiullah Ali, Christian Zakian, Vasilis Ntziachristos

    Abstract: Current optoacoustic microscopy configurations often have narrow focal ranges that limit their use for fast volumetric imaging applications. Here, the focal range of optoacoustic microscopes is extended by matching the elongated optical illumination profile of a Bessel beam with the pencil beam acoustic sensitivity profile of a broadband axicon detector. An inverted optoacoustic microscope was dev… ▽ More

    Submitted 13 April, 2021; originally announced April 2021.

    Comments: 11 pages, 5 figures, one supplemental figure

  7. arXiv:2102.12960  [pdf

    eess.IV cs.LG

    Deep learning based electrical noise removal enables high spectral optoacoustic contrast in deep tissue

    Authors: Christoph Dehner, Ivan Olefir, Kaushik Basak Chowdhury, Dominik Jüstel, Vasilis Ntziachristos

    Abstract: Image contrast in multispectral optoacoustic tomography (MSOT) can be severely reduced by electrical noise and interference in the acquired optoacoustic signals. Signal processing techniques have proven insufficient to remove the effects of electrical noise because they typically rely on simplified models and fail to capture complex characteristics of signal and noise. Moreover, they often involve… ▽ More

    Submitted 24 February, 2021; originally announced February 2021.

    Comments: 19 pages, 6 figures, 1 table

  8. A distance-based loss for smooth and continuous skin layer segmentation in optoacoustic images

    Authors: Stefan Gerl, Johannes C. Paetzold, Hailong He, Ivan Ezhov, Suprosanna Shit, Florian Kofler, Amirhossein Bayat, Giles Tetteh, Vasilis Ntziachristos, Bjoern Menze

    Abstract: Raster-scan optoacoustic mesoscopy (RSOM) is a powerful, non-invasive optical imaging technique for functional, anatomical, and molecular skin and tissue analysis. However, both the manual and the automated analysis of such images are challenging, because the RSOM images have very low contrast, poor signal to noise ratio, and systematic overlaps between the absorption spectra of melanin and hemogl… ▽ More

    Submitted 10 July, 2020; originally announced July 2020.

    Comments: Accepted at International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI) 2020

    ACM Class: I.2.1; J.3

    Journal ref: Medical Image Computing and Computer Assisted Intervention MICCAI 2020. MICCAI 2020. Lecture Notes in Computer Science, vol 12266. Springer

  9. arXiv:2002.01437  [pdf

    physics.bio-ph physics.ins-det physics.optics

    Optoacoustic flow-cytometry with light scattering referencing

    Authors: Markus Seeger, Andre C. Stiel, Vasilis Ntziachristos

    Abstract: In analogy to the development of fluorescent proteins, innovative tools for screening optoacoustic cell labels could lead to tailored protein labels for OA, imparting novel ways to visualize biological structure and function. Optoacoustic imaging emerges towards a highly promising modality for life sciences and medical practise with advantageous capabilities such as great accessible depth, and 3D… ▽ More

    Submitted 2 February, 2020; originally announced February 2020.

  10. Sub-micron silicon-on-insulator resonator for ultrasound detection

    Authors: Rami Shnaiderman, Georg Wissmeyer, Héctor Estrada, Daniel Razansky, Qutaiba Mustafa, Andriy Chmyrov, Vasilis Ntziachristos

    Abstract: Point-like broadband ultrasound detection can significantly increase the resolution of ultrasonography and optoacoustic (photoacoustic) imaging, yet current ultrasound detectors cannot be miniaturised sufficiently. Piezoelectric transducers lose sensitivity quadratically with size reduction, while optical micro-ring resonators and Fabry-Pérot etalons fail to adequately confine light at dimensions… ▽ More

    Submitted 11 February, 2019; originally announced February 2019.

  11. arXiv:1707.08391  [pdf, other

    physics.med-ph cs.CV eess.IV physics.optics

    Maximum entropy based non-negative optoacoustic tomographic image reconstruction

    Authors: Jaya Prakash, Subhamoy Mandal, Daniel Razansky, Vasilis Ntziachristos

    Abstract: Objective:Optoacoustic (photoacoustic) tomography is aimed at reconstructing maps of the initial pressure rise induced by the absorption of light pulses in tissue. In practice, due to inaccurate assumptions in the forward model, noise and other experimental factors, the images are often afflicted by artifacts, occasionally manifested as negative values. The aim of the work is to develop an inversi… ▽ More

    Submitted 11 January, 2019; v1 submitted 26 July, 2017; originally announced July 2017.

    Comments: This article has been accepted for publication in IEEE Transactions on Biomedical Engineering (30 Dec 2018)

  12. arXiv:1511.05846  [pdf

    physics.med-ph cs.CV physics.optics q-bio.QM

    Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues

    Authors: Stratis Tzoumas, Antonio Nunes, Ivan Olefir, Stefan Stangl, Panagiotis Symvoulidis, Sarah Glasl, Christine Bayer, Gabriele Multhoff, Vasilis Ntziachristos

    Abstract: Light propagating in tissue attains a spectrum that varies with location due to wavelength-dependent fluence attenuation by tissue optical properties, an effect that causes spectral corruption. Predictions of the spectral variations of light fluence in tissue are challenging since the spatial distribution of optical properties in tissue cannot be resolved in high resolution or with high accuracy b… ▽ More

    Submitted 18 November, 2015; originally announced November 2015.

  13. arXiv:1501.02450  [pdf

    q-bio.NC physics.med-ph physics.optics

    Functional optoacoustic neuro-tomography (FONT) for whole-brain monitoring of calcium indicators

    Authors: Gali Sela, Antonella Lauri, X. Luís Deán-Ben, Moritz Kneipp, Vasilis Ntziachristos, Shy Shoham, Gil G. Westmeyer, Daniel Razansky

    Abstract: Non-invasive observation of spatiotemporal neural activity of large neural populations distributed over entire brains is a longstanding goal of neuroscience. We developed a real-time volumetric and multispectral optoacoustic tomography platform for imaging of neural activation deep in scattering brains. The system can record 100 volumetric frames per second across a 200mm3 field of view and spatia… ▽ More

    Submitted 11 January, 2015; originally announced January 2015.

    Comments: 4 pages, 4 figures

  14. arXiv:1412.3241  [pdf

    physics.optics

    High contrast imaging of reversibly switchable fluorescent proteins via temporally unmixed Multispectral Optoacoustic Tomography (tuMSOT)

    Authors: Andre C Stiel, X Luis Dean-Ben, Yuanyuan Jiang, Vasilis Ntziachristos, Daniel Razansky, Gil G Westmeyer

    Abstract: Photocontrol of reversibly switchable fluorescent proteins (RSFPs) was used to program optoacoustic signal time courses that were temporally unmixed to increase the proteins contrast-to-noise-ratios (CNRs) in optoacoustic imaging. In this way, two variants of the RSFP Dronpa with very similar optoacoustic spectra could be readily discriminated in the presence of highly absorbing blood. Addition of… ▽ More

    Submitted 10 December, 2014; originally announced December 2014.