Spotlight on nerves: Portable multispectral optoacoustic imaging of peripheral nerve vascularization and morphology
Authors:
Dominik Jüstel,
Hedwig Irl,
Florian Hinterwimmer,
Christoph Dehner,
Walter Simson,
Nassir Navab,
Gerhard Schneider,
Vasilis Ntziachristos
Abstract:
Various morphological and functional parameters of peripheral nerves and their vascular supply are indicative of pathological changes due to injury or disease. Based on recent improvements in optoacoustic image quality, we explore the ability of multispectral optoacoustic tomography, in tandem with ultrasound imaging (OPUS), to investigate the vascular environment and morphology of peripheral nerv…
▽ More
Various morphological and functional parameters of peripheral nerves and their vascular supply are indicative of pathological changes due to injury or disease. Based on recent improvements in optoacoustic image quality, we explore the ability of multispectral optoacoustic tomography, in tandem with ultrasound imaging (OPUS), to investigate the vascular environment and morphology of peripheral nerves in vivo in a pilot study on healthy volunteers. We showcase the unique ability of optoacoustic imaging to visualize the vasa nervorum by observing intraneurial vessels in healthy nerves in vivo for the first time. In addition, we demonstrate that the label-free spectral optoacoustic contrast of the perfused connective tissue of peripheral nerves can be linked to the endogenous contrast of haemoglobin and collagen. We introduce metrics to analyze the composition of tissue based on its optoacoustic contrast and show that the high-resolution spectral contrast reveals specific differences between nervous tissue and reference tissue in the nerve's surrounding. We discuss how this showcased extraction of peripheral nerve characteristics using multispectral optoacoustic and ultrasound imaging can offer new insights into the pathophysiology of nerve damage and neuropathies, for example, in the context of diabetes.
△ Less
Submitted 28 July, 2022;
originally announced July 2022.
-
DeepMB: Deep neural network for real-time optoacoustic image reconstruction with adjustable speed of sound
Authors:
Christoph Dehner,
Guillaume Zahnd,
Vasilis Ntziachristos,
Dominik Jüstel
Abstract:
Multispectral optoacoustic tomography (MSOT) is a high-resolution functional imaging modality that can non-invasively access a broad range of pathophysiological phenomena by quantifying the contrast of endogenous chromophores in tissue. Real-time imaging is imperative to translate MSOT into clinical imaging, visualize dynamic pathophysiological changes associated with disease progression, and enab…
▽ More
Multispectral optoacoustic tomography (MSOT) is a high-resolution functional imaging modality that can non-invasively access a broad range of pathophysiological phenomena by quantifying the contrast of endogenous chromophores in tissue. Real-time imaging is imperative to translate MSOT into clinical imaging, visualize dynamic pathophysiological changes associated with disease progression, and enable in situ diagnoses. Model-based reconstruction affords state-of-the-art optoacoustic images; however, the image quality provided by model-based reconstruction remains inaccessible during real-time imaging because the algorithm is iterative and computationally demanding. Deep learning affords faster reconstruction, but the lack of ground truth training data can lead to reduced image quality for in vivo data. We introduce a framework, termed DeepMB, that achieves accurate optoacoustic image reconstruction for arbitrary input data in 31 ms per image by expressing model-based reconstruction with a deep neural network. DeepMB facilitates accurate generalization to experimental test data through training on signals synthesized from real-world images and ground truth images generated by model-based reconstruction. The framework affords in-focus images for a broad range of anatomical locations because it supports dynamic adjustment of the reconstruction speed of sound during imaging. Furthermore, DeepMB is compatible with the data rates and image sizes of modern multispectral optoacoustic tomography scanners. We evaluate DeepMB on a diverse dataset of in vivo images and demonstrate that the framework reconstructs images 1000 times faster than the iterative model-based reference method while affording near-identical image qualities. Accurate and real-time image reconstructions with DeepMB can enable full access to the high-resolution and multispectral contrast of handheld optoacoustic tomography.
△ Less
Submitted 11 April, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Enabling the autofocus approach for parameter optimization in planar measurement geometry clinical optoacoustic imaging
Authors:
Ludwig Englert,
Lucas Riobo,
Christine Schonemann,
Vasilis Ntziachristos,
Juan Aguirre
Abstract:
In optoacoustic (photoacoustic) tomography, several parameters related to tissue and detector features are needed for image formation, but they may not be known a priori. An autofocus (AF) algorithm is generally used to estimate these parameters. However, the algorithm works iteratively, therefore, it is impractical for clinical imaging with systems featuring planar geometry due to long reconstruc…
▽ More
In optoacoustic (photoacoustic) tomography, several parameters related to tissue and detector features are needed for image formation, but they may not be known a priori. An autofocus (AF) algorithm is generally used to estimate these parameters. However, the algorithm works iteratively, therefore, it is impractical for clinical imaging with systems featuring planar geometry due to long reconstruction times.
We have developed a fast autofocus (FAF) algorithm for optoacoustic systems with planar geometry that is much simpler computationally than the conventional AF algorithm. We show that the FAF algorithm required about 5 sec. to provide accurate estimates of the speed of sound in simulated data and experimental data obtained using an imaging system that is poised to enter the clinic. The applicability of FAF for estimating other image formation parameters is discussed.
We expect the FAF algorithm to contribute decisively to the clinical use of optoacoustic tomography systems with planar geometry.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
Self-Supervised Learning from Unlabeled Fundus Photographs Improves Segmentation of the Retina
Authors:
Jan Kukačka,
Anja Zenz,
Marcel Kollovieh,
Dominik Jüstel,
Vasilis Ntziachristos
Abstract:
Fundus photography is the primary method for retinal imaging and essential for diabetic retinopathy prevention. Automated segmentation of fundus photographs would improve the quality, capacity, and cost-effectiveness of eye care screening programs. However, current segmentation methods are not robust towards the diversity in imaging conditions and pathologies typical for real-world clinical applic…
▽ More
Fundus photography is the primary method for retinal imaging and essential for diabetic retinopathy prevention. Automated segmentation of fundus photographs would improve the quality, capacity, and cost-effectiveness of eye care screening programs. However, current segmentation methods are not robust towards the diversity in imaging conditions and pathologies typical for real-world clinical applications. To overcome these limitations, we utilized contrastive self-supervised learning to exploit the large variety of unlabeled fundus images in the publicly available EyePACS dataset. We pre-trained an encoder of a U-Net, which we later fine-tuned on several retinal vessel and lesion segmentation datasets. We demonstrate for the first time that by using contrastive self-supervised learning, the pre-trained network can recognize blood vessels, optic disc, fovea, and various lesions without being provided any labels. Furthermore, when fine-tuned on a downstream blood vessel segmentation task, such pre-trained networks achieve state-of-the-art performance on images from different datasets. Additionally, the pre-training also leads to shorter training times and an improved few-shot performance on both blood vessel and lesion segmentation tasks. Altogether, our results showcase the benefits of contrastive self-supervised pre-training which can play a crucial role in real-world clinical applications requiring robust models able to adapt to new devices with only a few annotated samples.
△ Less
Submitted 5 August, 2021;
originally announced August 2021.
-
Disentangling the frequency content in optoacoustics
Authors:
Antonia Longo,
Dominik Jüstel,
Vasilis Ntziachristos
Abstract:
Signals acquired by optoacoustic tomography systems have broadband frequency content that encodes information about structures on different physical scales. Concurrent processing and rendering of such broadband signals may result in images with poor contrast and fidelity due to a bias towards low frequency contributions from larger structures. This problem cannot be addressed by filtering differen…
▽ More
Signals acquired by optoacoustic tomography systems have broadband frequency content that encodes information about structures on different physical scales. Concurrent processing and rendering of such broadband signals may result in images with poor contrast and fidelity due to a bias towards low frequency contributions from larger structures. This problem cannot be addressed by filtering different frequency bands and reconstructing them individually, as this procedure leads to artefacts due to its incompatibility with the entangled frequency content of signals generated by structures of different sizes. Here we introduce frequency-band model-based (fbMB) reconstruction to separate frequency-band-specific optoacoustic image components during image formation, thereby enabling structures of all sizes to be rendered with high fidelity. In order to disentangle the overlap** frequency content of image components, fbMB uses soft priors to achieve an optimal trade-off between localization of the components in frequency bands and their structural integrity. We demonstrate that fbMB produces optoacoustic images with improved contrast and fidelity, which reveal anatomical structures in in vivo images of mice in unprecedented detail. These enhancements further improve the accuracy of spectral unmixing in small vasculature. By offering a precise treatment of the frequency components of optoacoustic signals, fbMB improves the quality, accuracy, and quantification of optoacoustic images and provides a method of choice for optoacoustic reconstructions.
△ Less
Submitted 29 April, 2021;
originally announced April 2021.
-
Elongated focus optoacoustic microscopy with matched Bessel beam illumination and ultra-broadband axicon detection
Authors:
Zakiullah Ali,
Christian Zakian,
Vasilis Ntziachristos
Abstract:
Current optoacoustic microscopy configurations often have narrow focal ranges that limit their use for fast volumetric imaging applications. Here, the focal range of optoacoustic microscopes is extended by matching the elongated optical illumination profile of a Bessel beam with the pencil beam acoustic sensitivity profile of a broadband axicon detector. An inverted optoacoustic microscope was dev…
▽ More
Current optoacoustic microscopy configurations often have narrow focal ranges that limit their use for fast volumetric imaging applications. Here, the focal range of optoacoustic microscopes is extended by matching the elongated optical illumination profile of a Bessel beam with the pencil beam acoustic sensitivity profile of a broadband axicon detector. An inverted optoacoustic microscope was developed with interchangeable optical illumination and acoustic detection units to assess the imaging depths and resolutions retained with several combinations of illumination and detection profiles. Matching Bessel illumination with axicon detection extends the depth-of-focus 17-fold over traditional configurations. Imaging a tilted mouse ear with the matched Bessel-axicon configuration revealed vasculature over an imaging depth exceeding 4.2 mm with optical resolution, while affording a 6-fold increase in imaging volume over the same scanning duration compared to configurations employing standard Gaussian illumination, demonstrating this approach's promise for increasing applications for optoacoustic microscopy in preclinical research.
△ Less
Submitted 13 April, 2021;
originally announced April 2021.
-
Deep learning based electrical noise removal enables high spectral optoacoustic contrast in deep tissue
Authors:
Christoph Dehner,
Ivan Olefir,
Kaushik Basak Chowdhury,
Dominik Jüstel,
Vasilis Ntziachristos
Abstract:
Image contrast in multispectral optoacoustic tomography (MSOT) can be severely reduced by electrical noise and interference in the acquired optoacoustic signals. Signal processing techniques have proven insufficient to remove the effects of electrical noise because they typically rely on simplified models and fail to capture complex characteristics of signal and noise. Moreover, they often involve…
▽ More
Image contrast in multispectral optoacoustic tomography (MSOT) can be severely reduced by electrical noise and interference in the acquired optoacoustic signals. Signal processing techniques have proven insufficient to remove the effects of electrical noise because they typically rely on simplified models and fail to capture complex characteristics of signal and noise. Moreover, they often involve time-consuming processing steps that are unsuited for real-time imaging applications. In this work, we develop and demonstrate a discriminative deep learning (DL) approach to separate electrical noise from optoacoustic signals prior to image reconstruction. The proposed DL algorithm is based on two key features. First, it learns spatiotemporal correlations in both noise and signal by using the entire optoacoustic sinogram as input. Second, it employs training based on a large dataset of experimentally acquired pure noise and synthetic optoacoustic signals. We validated the ability of the trained model to accurately remove electrical noise on synthetic data and on optoacoustic images of a phantom and the human breast. We demonstrate significant enhancements of morphological and spectral optoacoustic images reaching 19% higher blood vessel contrast and localized spectral contrast at depths of more than 2 cm for images acquired in vivo. We discuss how the proposed denoising framework is applicable to clinical multispectral optoacoustic tomography and suitable for real-time operation.
△ Less
Submitted 24 February, 2021;
originally announced February 2021.
-
A distance-based loss for smooth and continuous skin layer segmentation in optoacoustic images
Authors:
Stefan Gerl,
Johannes C. Paetzold,
Hailong He,
Ivan Ezhov,
Suprosanna Shit,
Florian Kofler,
Amirhossein Bayat,
Giles Tetteh,
Vasilis Ntziachristos,
Bjoern Menze
Abstract:
Raster-scan optoacoustic mesoscopy (RSOM) is a powerful, non-invasive optical imaging technique for functional, anatomical, and molecular skin and tissue analysis. However, both the manual and the automated analysis of such images are challenging, because the RSOM images have very low contrast, poor signal to noise ratio, and systematic overlaps between the absorption spectra of melanin and hemogl…
▽ More
Raster-scan optoacoustic mesoscopy (RSOM) is a powerful, non-invasive optical imaging technique for functional, anatomical, and molecular skin and tissue analysis. However, both the manual and the automated analysis of such images are challenging, because the RSOM images have very low contrast, poor signal to noise ratio, and systematic overlaps between the absorption spectra of melanin and hemoglobin. Nonetheless, the segmentation of the epidermis layer is a crucial step for many downstream medical and diagnostic tasks, such as vessel segmentation or monitoring of cancer progression. We propose a novel, shape-specific loss function that overcomes discontinuous segmentations and achieves smooth segmentation surfaces while preserving the same volumetric Dice and IoU. Further, we validate our epidermis segmentation through the sensitivity of vessel segmentation. We found a 20 $\%$ improvement in Dice for vessel segmentation tasks when the epidermis mask is provided as additional information to the vessel segmentation network.
△ Less
Submitted 10 July, 2020;
originally announced July 2020.
-
Optoacoustic flow-cytometry with light scattering referencing
Authors:
Markus Seeger,
Andre C. Stiel,
Vasilis Ntziachristos
Abstract:
In analogy to the development of fluorescent proteins, innovative tools for screening optoacoustic cell labels could lead to tailored protein labels for OA, imparting novel ways to visualize biological structure and function. Optoacoustic imaging emerges towards a highly promising modality for life sciences and medical practise with advantageous capabilities such as great accessible depth, and 3D…
▽ More
In analogy to the development of fluorescent proteins, innovative tools for screening optoacoustic cell labels could lead to tailored protein labels for OA, imparting novel ways to visualize biological structure and function. Optoacoustic imaging emerges towards a highly promising modality for life sciences and medical practise with advantageous capabilities such as great accessible depth, and 3D studying of living tissue. The development of novel labels with molecular specificity could significantly enhance the optoacoustic contrast, specificity, and sensitivity and allow optoacoustic to interrogate tissues not amenable to the fluorescence method. We report on an optoacoustic flow cytometer (OAFC) prototype, developed for screening optoacoustic reporter genes. The cytometer concurrently records light scattering for referencing purposes. Since recording light scattering is completely independent from OA, we believe it to be a more reliable referencing method than e.g. fluorescence or ultrasound-backscatter. Precise characterization of our OAFC prototype showcases its ability to optoacoustically characterize objects in-flow that are in the size range of single cells. We apply the OAFC to distinguish individual E. coli cells based on optoacoustic properties of their expressed chromoproteins read in-flow using microfluidic arrangements and achieved precisions over 90%. We discuss how the light scattering referenced OAFC method offers a critical step towards routine measurement of optoacoustic properties of single-cells and could pave the way for identifying genetically encoded optoacoustic reporters, by transferring working concepts of the fluorescence field.
△ Less
Submitted 2 February, 2020;
originally announced February 2020.
-
Sub-micron silicon-on-insulator resonator for ultrasound detection
Authors:
Rami Shnaiderman,
Georg Wissmeyer,
Héctor Estrada,
Daniel Razansky,
Qutaiba Mustafa,
Andriy Chmyrov,
Vasilis Ntziachristos
Abstract:
Point-like broadband ultrasound detection can significantly increase the resolution of ultrasonography and optoacoustic (photoacoustic) imaging, yet current ultrasound detectors cannot be miniaturised sufficiently. Piezoelectric transducers lose sensitivity quadratically with size reduction, while optical micro-ring resonators and Fabry-Pérot etalons fail to adequately confine light at dimensions…
▽ More
Point-like broadband ultrasound detection can significantly increase the resolution of ultrasonography and optoacoustic (photoacoustic) imaging, yet current ultrasound detectors cannot be miniaturised sufficiently. Piezoelectric transducers lose sensitivity quadratically with size reduction, while optical micro-ring resonators and Fabry-Pérot etalons fail to adequately confine light at dimensions smaller than $\sim$ 50 microns. Micromachining methods have been used to generate arrays of capacitive and piezoelectric transducers, but at bandwidths of only a few MHz and dimensions not smaller than 70 microns. Here we use the widely available silicon-on-insulator (SOI) platform to develop the worlds smallest ultrasound detector with a sub-micron sensing area of 220 $\times$ 500 nanometers. The SOI-based optical resonator design can provide per-area sensitivity that is $10^{4}$-fold higher than for micro-ring resonators and $10^{8}$-fold higher than for piezoelectric detectors. We also demonstrate ultra-wide bandwidth reaching 230 MHz and conduct the first imaging based on an SOI ultrasound detector. The technology showcased is suitable for manufacturing ultra-dense detector arrays ($\geq125$ $detectors\backslash mm^{2}$), which have the potential to revolutionise ultrasonography and optoacoustic imaging.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Maximum entropy based non-negative optoacoustic tomographic image reconstruction
Authors:
Jaya Prakash,
Subhamoy Mandal,
Daniel Razansky,
Vasilis Ntziachristos
Abstract:
Objective:Optoacoustic (photoacoustic) tomography is aimed at reconstructing maps of the initial pressure rise induced by the absorption of light pulses in tissue. In practice, due to inaccurate assumptions in the forward model, noise and other experimental factors, the images are often afflicted by artifacts, occasionally manifested as negative values. The aim of the work is to develop an inversi…
▽ More
Objective:Optoacoustic (photoacoustic) tomography is aimed at reconstructing maps of the initial pressure rise induced by the absorption of light pulses in tissue. In practice, due to inaccurate assumptions in the forward model, noise and other experimental factors, the images are often afflicted by artifacts, occasionally manifested as negative values. The aim of the work is to develop an inversion method which reduces the occurrence of negative values and improves the quantitative performance of optoacoustic imaging. Methods: We present a novel method for optoacoustic tomography based on an entropy maximization algorithm, which uses logarithmic regularization for attaining non-negative reconstructions. The reconstruction image quality is further improved using structural prior based fluence correction. Results: We report the performance achieved by the entropy maximization scheme on numerical simulation, experimental phantoms and in-vivo samples. Conclusion: The proposed algorithm demonstrates superior reconstruction performance by delivering non-negative pixel values with no visible distortion of anatomical structures. Significance: Our method can enable quantitative optoacoustic imaging, and has the potential to improve pre-clinical and translational imaging applications.
△ Less
Submitted 11 January, 2019; v1 submitted 26 July, 2017;
originally announced July 2017.
-
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
Authors:
Stratis Tzoumas,
Antonio Nunes,
Ivan Olefir,
Stefan Stangl,
Panagiotis Symvoulidis,
Sarah Glasl,
Christine Bayer,
Gabriele Multhoff,
Vasilis Ntziachristos
Abstract:
Light propagating in tissue attains a spectrum that varies with location due to wavelength-dependent fluence attenuation by tissue optical properties, an effect that causes spectral corruption. Predictions of the spectral variations of light fluence in tissue are challenging since the spatial distribution of optical properties in tissue cannot be resolved in high resolution or with high accuracy b…
▽ More
Light propagating in tissue attains a spectrum that varies with location due to wavelength-dependent fluence attenuation by tissue optical properties, an effect that causes spectral corruption. Predictions of the spectral variations of light fluence in tissue are challenging since the spatial distribution of optical properties in tissue cannot be resolved in high resolution or with high accuracy by current methods. Spectral corruption has fundamentally limited the quantification accuracy of optical and optoacoustic methods and impeded the long sought-after goal of imaging blood oxygen saturation (sO2) deep in tissues; a critical but still unattainable target for the assessment of oxygenation in physiological processes and disease. We discover a new principle underlying light fluence in tissues, which describes the wavelength dependence of light fluence as an affine function of a few reference base spectra, independently of the specific distribution of tissue optical properties. This finding enables the introduction of a previously undocumented concept termed eigenspectra Multispectral Optoacoustic Tomography (eMSOT) that can effectively account for wavelength dependent light attenuation without explicit knowledge of the tissue optical properties. We validate eMSOT in more than 2000 simulations and with phantom and animal measurements. We find that eMSOT can quantitatively image tissue sO2 reaching in many occasions a better than 10-fold improved accuracy over conventional spectral optoacoustic methods. Then, we show that eMSOT can spatially resolve sO2 in muscle and tumor; revealing so far unattainable tissue physiology patterns. Last, we related eMSOT readings to cancer hypoxia and found congruence between eMSOT tumor sO2 images and tissue perfusion and hypoxia maps obtained by correlative histological analysis.
△ Less
Submitted 18 November, 2015;
originally announced November 2015.
-
Functional optoacoustic neuro-tomography (FONT) for whole-brain monitoring of calcium indicators
Authors:
Gali Sela,
Antonella Lauri,
X. Luís Deán-Ben,
Moritz Kneipp,
Vasilis Ntziachristos,
Shy Shoham,
Gil G. Westmeyer,
Daniel Razansky
Abstract:
Non-invasive observation of spatiotemporal neural activity of large neural populations distributed over entire brains is a longstanding goal of neuroscience. We developed a real-time volumetric and multispectral optoacoustic tomography platform for imaging of neural activation deep in scattering brains. The system can record 100 volumetric frames per second across a 200mm3 field of view and spatia…
▽ More
Non-invasive observation of spatiotemporal neural activity of large neural populations distributed over entire brains is a longstanding goal of neuroscience. We developed a real-time volumetric and multispectral optoacoustic tomography platform for imaging of neural activation deep in scattering brains. The system can record 100 volumetric frames per second across a 200mm3 field of view and spatial resolutions below 70um. Experiments performed in immobilized and freely swimming larvae and in adult zebrafish brains demonstrate, for the first time, the fundamental ability to optoacoustically track neural calcium dynamics in animals labeled with genetically encoded calcium indicator GCaMP5G, while overcoming the longstanding penetration barrier of optical imaging in scattering brains. The newly developed platform offers unprecedented capabilities for functional whole-brain observations of fast calcium dynamics; in combination with optoacoustics' well-established capacity in resolving vascular hemodynamics, it could open new vistas in the study of neural activity and neurovascular coupling in health and disease.
△ Less
Submitted 11 January, 2015;
originally announced January 2015.
-
High contrast imaging of reversibly switchable fluorescent proteins via temporally unmixed Multispectral Optoacoustic Tomography (tuMSOT)
Authors:
Andre C Stiel,
X Luis Dean-Ben,
Yuanyuan Jiang,
Vasilis Ntziachristos,
Daniel Razansky,
Gil G Westmeyer
Abstract:
Photocontrol of reversibly switchable fluorescent proteins (RSFPs) was used to program optoacoustic signal time courses that were temporally unmixed to increase the proteins contrast-to-noise-ratios (CNRs) in optoacoustic imaging. In this way, two variants of the RSFP Dronpa with very similar optoacoustic spectra could be readily discriminated in the presence of highly absorbing blood. Addition of…
▽ More
Photocontrol of reversibly switchable fluorescent proteins (RSFPs) was used to program optoacoustic signal time courses that were temporally unmixed to increase the proteins contrast-to-noise-ratios (CNRs) in optoacoustic imaging. In this way, two variants of the RSFP Dronpa with very similar optoacoustic spectra could be readily discriminated in the presence of highly absorbing blood. Addition of temporal unmixing to multispectral optoacoustic tomography (tuMSOT) in conjunction with synthetic or genetically controlled photochromic contrast agents and customized photoswitching schedules can increase the performance of multiplexed and high contrast molecular optoacoustic imaging.
△ Less
Submitted 10 December, 2014;
originally announced December 2014.