Skip to main content

Showing 1–5 of 5 results for author: Novgorodova, O

.
  1. arXiv:1411.4924  [pdf, other

    physics.ins-det

    ECFA Detector R&D Panel, Review Report

    Authors: The FCAL Collaboration, H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, P. Bambade, L. Bortko, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, A. Dragone, L. Dumitru, K. Elsener, I. Emeliantchik, E. Firu, J. Fischer, T. Fiutowski, V. Ghenescu, M. Gostkin, G. Grzelak, G. Haller, H. Henschel , et al. (46 additional authors not shown)

    Abstract: Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in… ▽ More

    Submitted 19 November, 2014; v1 submitted 18 November, 2014; originally announced November 2014.

    Comments: 61 pages, 51 figures

    Report number: LC-DET-2013-029

  2. arXiv:1411.4431  [pdf, other

    physics.ins-det

    Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

    Authors: The FCAL Collaboration, H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, D. Avila, Y. Benhammou, L. Bortko, O. Borysov, M. Bergholz, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, L. Dumitru, K. Elsener, V. Fadeyev, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, H. Henschel , et al. (44 additional authors not shown)

    Abstract: Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens… ▽ More

    Submitted 1 June, 2015; v1 submitted 17 November, 2014; originally announced November 2014.

    Comments: 25 pages, 32 figures, revised version following comments from referees

    Journal ref: JINST 10, P05009 (2015)

  3. arXiv:1111.5199  [pdf, other

    physics.ins-det

    Luminometer for the future International Linear Collider - simulation and beam test results

    Authors: J. A. Aguilar, S. Kulis, W. Wierba, L. Zawiejski, E. Kielar, M. Chrzaszcz, O. Novgorodova, H. Henschel, W. Lohmann, S. Schuwalow, K. Afanaciev, A. Ignatenko, S. Kollowa, I. Levy, M. Idzik, J. Kotula, A. Moszczynski, K. Oliwa, B. Pawlik, W. Daniluk

    Abstract: LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter module… ▽ More

    Submitted 22 November, 2011; originally announced November 2011.

    Comments: Technology and Instrumentation in Particle Physics 2011, Chicago, IL, USA. Presented June 11, 2011, and submitted to Physics Procedia

  4. Forward Instrumentation for ILC Detectors

    Authors: Halina Abramowicz, Angel Abusleme, Konstantin Afanaciev, Jonathan Aguilar, Prasoon Ambalathankandy, Philip Bambade, Matthias Bergholz, Ivanka Bozovic-Jelisavcic, Elena Castro, Georgy Chelkov, Cornelia Coca, Witold Daniluk, Angelo Dragone, Laurentiu Dumitru, Konrad Elsener, Igor Emeliantchik, Tomasz Fiutowski, Mikhail Gostkin, Christian Grah, Grzegorz Grzelak, Gunter Haller, Hans Henschel, Alexandr Ignatenko, Marek Idzik, Kazutoshi Ito , et al. (33 additional authors not shown)

    Abstract: Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil… ▽ More

    Submitted 3 November, 2010; v1 submitted 13 September, 2010; originally announced September 2010.

    Comments: 30 pages, 28 figures

    Report number: DESY 10-142

    Journal ref: JINST 5:P12002,2010

  5. arXiv:1006.3402  [pdf, ps, other

    physics.ins-det hep-ex

    Studies on the Electron Reconstruction Efficiency for the Beam Calorimeter of an ILC Detector

    Authors: Olga Novgorodova

    Abstract: In this talk recent simulation results on the single high energy electron reconstruction with the Beam Calorimeter for the ILD detector are presented. Guinea Pig is used to generate the e+e- pair background and GEANT4 for the simulation of electron showers in the calorimeter. An algorithm was developed for the sHEe reconstruction on top of the large e+e- background. The efficiency of the sHEe reco… ▽ More

    Submitted 17 June, 2010; originally announced June 2010.

    Comments: 4 pages, 4 figures, Beam Calorimeter, Mokka, SB-2009, Nominal beam parameters, BeCaS, GEANT4, sHEe, single high energy electron reconstruction, efficiency, fake rate