-
A simple theory for interfacial properties of dilute solutions
Authors:
Varun Mandalaparthy,
W. G. Noid
Abstract:
Recent studies suggest that cosolute mixtures may exert significant non-additive effects upon protein stability. The corresponding liquid-vapor interfaces may provide useful insight into these non-additive effects. Accordingly, in this work we relate the interfacial properties of dilute multicomponent solutions to the interactions between solutes. We first derive a simple model for the surface exc…
▽ More
Recent studies suggest that cosolute mixtures may exert significant non-additive effects upon protein stability. The corresponding liquid-vapor interfaces may provide useful insight into these non-additive effects. Accordingly, in this work we relate the interfacial properties of dilute multicomponent solutions to the interactions between solutes. We first derive a simple model for the surface excess of solutes in terms of thermodynamic observables. We then develop a lattice-based statistical mechanical perturbation theory to derive these observables from microscopic interactions. Rather than adopting a random mixing approximation, this dilute solution theory (DST) exactly treats solute-solute interactions to lowest order in perturbation theory. Although it cannot treat concentrated solutions, Monte Carlo (MC) simulations demonstrate that DST describes dilute solutions with much greater accuracy than regular solution theory. Importantly, DST emphasizes an important distinction between the `intrinsic' and `effective' preferences of solutes for interfaces. DST predicts that three classes of solutes can be distinguished by their intrinsic preference for interfaces. While the surface preference of strong depletants are relatively insensitive to interactions, the surface preference of strong surfactants can be modulated by interactions at the interface. Moreover, DST predicts that the surface preference of weak depletants and weak surfactants can be qualitatively inverted by interactions in the bulk. We also demonstrate that DST can be extended to treat surface polarization effects and to model experimental data. MC simulations validate the accuracy of DST predictions for lattice systems that correspond to molar concentrations.
△ Less
Submitted 10 May, 2022;
originally announced May 2022.
-
Measurement of the neutron decay electron-antineutrino angular correlation by the aCORN experiment
Authors:
M. T. Hassan,
W. A. Byron,
G. Darius,
C. DeAngelis,
F. E. Wietfeldt,
B. Collett,
G. L. Jones,
A. Komives,
G. Noid,
E. J. Stephenson,
F. Bateman,
M. S. Dewey,
T. R. Gentile,
M. P. Mendenhall,
J. S. Nico
Abstract:
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on t…
▽ More
The aCORN experiment measures the neutron decay electron-antineutrino correlation ($a$-coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on the new NG-C neutron guide end position: $a = -0.10758 \pm 0.00136 (\mbox{stat}) \pm 0.00148 (\mbox{sys})$. This is consistent within uncertainties with the result from the first aCORN run on the NG-6 cold neutron beam. Combining the two aCORN runs we obtain $a = -0.10782 \pm 0.00124 (\mbox{stat}) \pm 0.00133 (\mbox{sys})$, which has an overall relative standard uncertainty of 1.7 \%. The corresponding result for the ratio of weak coupling constants $λ= G_A/G_V$ is $λ= -1.2796\pm 0.0062$.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
aCORN: an experiment to measure the electron-antineutrino correlation coefficient in free neutron decay
Authors:
B. Collett,
F. Bateman,
W. K. Bauder,
J. Byrne,
W. A. Byron,
W. Chen,
G. Darius,
C. DeAngelis,
M. S. Dewey,
T. R. Gentile,
M. T. Hassan,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
H. Park,
E. J. Stephenson,
I. Stern,
K. J. S. Stockton,
C. Trull,
F. E. Wietfeldt,
B. G. Yerozolimsky
Abstract:
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data…
▽ More
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
△ Less
Submitted 21 February, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.
-
The aCORN Backscatter-Suppressed Beta Spectrometer
Authors:
M. T. Hassan,
F. Bateman,
B. Collett,
G. Darius,
C. DeAngelis,
M. S. Dewey,
G. L. Jones,
A. Komives,
A. Laptev,
M. P. Mendenhall,
J. S. Nico,
G. Noid,
E. J. Stephenson,
I. Stern,
C. Trull,
F. E. Wietfeldt
Abstract:
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter ve…
▽ More
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron-antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for esca** back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.
△ Less
Submitted 25 January, 2017; v1 submitted 17 January, 2017;
originally announced January 2017.