-
Bayesian Logistic Shape Model Inference: application to cochlea image segmentation
Authors:
Wang Zihao,
Demarcy Thomas,
Vandersteen Clair,
Gnansia Dan,
Raffaelli Charles,
Guevara Nicolas,
Delingette Hervé
Abstract:
Incorporating shape information is essential for the delineation of many organs and anatomical structures in medical images. While previous work has mainly focused on parametric spatial transformations applied on reference template shapes, in this paper, we address the Bayesian inference of parametric shape models for segmenting medical images with the objective to provide interpretable results. T…
▽ More
Incorporating shape information is essential for the delineation of many organs and anatomical structures in medical images. While previous work has mainly focused on parametric spatial transformations applied on reference template shapes, in this paper, we address the Bayesian inference of parametric shape models for segmenting medical images with the objective to provide interpretable results. The proposed framework defines a likelihood appearance probability and a prior label probability based on a generic shape function through a logistic function. A reference length parameter defined in the sigmoid controls the trade-off between shape and appearance information. The inference of shape parameters is performed within an Expectation-Maximisation approach where a Gauss-Newton optimization stage allows to provide an approximation of the posterior probability of shape parameters. This framework is applied to the segmentation of cochlea structures from clinical CT images constrained by a 10 parameter shape model. It is evaluated on three different datasets, one of which includes more than 200 patient images. The results show performances comparable to supervised methods and better than previously proposed unsupervised ones. It also enables an analysis of parameter distributions and the quantification of segmentation uncertainty including the effect of the shape model.
△ Less
Submitted 5 May, 2021;
originally announced May 2021.
-
Inner-ear Augmented Metal Artifact Reduction with Simulation-based 3D Generative Adversarial Networks
Authors:
Wang Zihao,
Vandersteen Clair,
Demarcy Thomas,
Gnansia Dan,
Raffaelli Charles,
Guevara Nicolas,
Delingette Herve
Abstract:
Metal Artifacts creates often difficulties for a high quality visual assessment of post-operative imaging in {c}omputed {t}omography (CT). A vast body of methods have been proposed to tackle this issue, but {these} methods were designed for regular CT scans and their performance is usually insufficient when imaging tiny implants. In the context of post-operative high-resolution {CT} imaging, we pr…
▽ More
Metal Artifacts creates often difficulties for a high quality visual assessment of post-operative imaging in {c}omputed {t}omography (CT). A vast body of methods have been proposed to tackle this issue, but {these} methods were designed for regular CT scans and their performance is usually insufficient when imaging tiny implants. In the context of post-operative high-resolution {CT} imaging, we propose a 3D metal {artifact} reduction algorithm based on a generative adversarial neural network. It is based on the simulation of physically realistic CT metal artifacts created by cochlea implant electrodes on preoperative images. The generated images serve to train a 3D generative adversarial networks for artifacts reduction. The proposed approach was assessed qualitatively and quantitatively on clinical conventional and cone-beam CT of cochlear implant postoperative images. These experiments show that the proposed method {outperforms other} general metal artifact reduction approaches.
△ Less
Submitted 26 April, 2021;
originally announced April 2021.
-
Role of NiO in the nonlocal spin transport through thin NiO films on Y$_3$Fe$_5$O$_{12}$
Authors:
Geert R. Hoogeboom,
Geert-Jan N. Sint Nicolaas,
Andreas Alexander,
Olga Kuschel,
Joachim Wollschläger,
Inga Ennen,
Bart J. van Wees,
Timo Kuschel
Abstract:
In spin transport experiments with spin currents propagating through antiferromagnetic (AFM) material, the antiferromagnet is treated as a mainly passive spin conductor not generating nor adding any spin current to the system. The spin current transmissivity of the AFM NiO is affected by magnetic fluctuations, peaking at the Néel temperature and decreasing by lowering the temperature. In order to…
▽ More
In spin transport experiments with spin currents propagating through antiferromagnetic (AFM) material, the antiferromagnet is treated as a mainly passive spin conductor not generating nor adding any spin current to the system. The spin current transmissivity of the AFM NiO is affected by magnetic fluctuations, peaking at the Néel temperature and decreasing by lowering the temperature. In order to study the role of the AFM in local and nonlocal spin transport experiments, we send spin currents through NiO of various thickness placed on Y$_3$Fe$_5$O$_{12}$. The spin currents are injected either electrically or by thermal gradients and measured at a wide range of temperatures and magnetic field strengths. The transmissive role is reflected in the sign change of the local electrically injected signals and the decrease in signal strength of all other signals by lowering the temperature. The thermally generated signals, however, show an additional upturn below 100$\,$K which are unaffected by an increased NiO thickness. A change in the thermal conductivity could affect these signals. The temperature and magnetic field dependence is similar as for bulk NiO, indicating that NiO itself contributes to thermally induced spin currents.
△ Less
Submitted 22 December, 2020;
originally announced December 2020.