-
ExoClock Project III: 450 new exoplanet ephemerides from ground and space observations
Authors:
A. Kokori,
A. Tsiaras,
B. Edwards,
A. Jones,
G. Pantelidou,
G. Tinetti,
L. Bewersdorff,
A. Iliadou,
Y. Jongen,
G. Lekkas,
A. Nastasi,
E. Poultourtzidis,
C. Sidiropoulos,
F. Walter,
A. Wünsche,
R. Abraham,
V. K. Agnihotri,
R. Albanesi,
E. Arce-Mansego,
D. Arnot,
M. Audejean,
C. Aumasson,
M. Bachschmidt,
G. Baj,
P. R. Barroy
, et al. (192 additional authors not shown)
Abstract:
The ExoClock project has been created with the aim of increasing the efficiency of the Ariel mission. It will achieve this by continuously monitoring and updating the ephemerides of Ariel candidates over an extended period, in order to produce a consistent catalogue of reliable and precise ephemerides. This work presents a homogenous catalogue of updated ephemerides for 450 planets, generated by t…
▽ More
The ExoClock project has been created with the aim of increasing the efficiency of the Ariel mission. It will achieve this by continuously monitoring and updating the ephemerides of Ariel candidates over an extended period, in order to produce a consistent catalogue of reliable and precise ephemerides. This work presents a homogenous catalogue of updated ephemerides for 450 planets, generated by the integration of $\sim$18000 data points from multiple sources. These sources include observations from ground-based telescopes (ExoClock network and ETD), mid-time values from the literature and light-curves from space telescopes (Kepler/K2 and TESS). With all the above, we manage to collect observations for half of the post-discovery years (median), with data that have a median uncertainty less than one minute. In comparison with literature, the ephemerides generated by the project are more precise and less biased. More than 40\% of the initial literature ephemerides had to be updated to reach the goals of the project, as they were either of low precision or drifting. Moreover, the integrated approach of the project enables both the monitoring of the majority of the Ariel candidates (95\%), and also the identification of missing data. The dedicated ExoClock network effectively supports this task by contributing additional observations when a gap in the data is identified. These results highlight the need for continuous monitoring to increase the observing coverage of the candidate planets. Finally, the extended observing coverage of planets allows us to detect trends (TTVs - Transit Timing Variations) for a sample of 19 planets. All products, data, and codes used in this work are open and accessible to the wider scientific community.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
AI-Driven CT-based quantification, staging and short-term outcome prediction of COVID-19 pneumonia
Authors:
Guillaume Chassagnon,
Maria Vakalopoulou,
Enzo Battistella,
Stergios Christodoulidis,
Trieu-Nghi Hoang-Thi,
Severine Dangeard,
Eric Deutsch,
Fabrice Andre,
Enora Guillo,
Nara Halm,
Stefany El Hajj,
Florian Bompard,
Sophie Neveu,
Chahinez Hani,
Ines Saab,
Alienor Campredon,
Hasmik Koulakian,
Souhail Bennani,
Gael Freche,
Aurelien Lombard,
Laure Fournier,
Hippolyte Monnier,
Teodor Grand,
Jules Gregory,
Antoine Khalil
, et al. (6 additional authors not shown)
Abstract:
Chest computed tomography (CT) is widely used for the management of Coronavirus disease 2019 (COVID-19) pneumonia because of its availability and rapidity. The standard of reference for confirming COVID-19 relies on microbiological tests but these tests might not be available in an emergency setting and their results are not immediately available, contrary to CT. In addition to its role for early…
▽ More
Chest computed tomography (CT) is widely used for the management of Coronavirus disease 2019 (COVID-19) pneumonia because of its availability and rapidity. The standard of reference for confirming COVID-19 relies on microbiological tests but these tests might not be available in an emergency setting and their results are not immediately available, contrary to CT. In addition to its role for early diagnosis, CT has a prognostic role by allowing visually evaluating the extent of COVID-19 lung abnormalities. The objective of this study is to address prediction of short-term outcomes, especially need for mechanical ventilation. In this multi-centric study, we propose an end-to-end artificial intelligence solution for automatic quantification and prognosis assessment by combining automatic CT delineation of lung disease meeting performance of experts and data-driven identification of biomarkers for its prognosis. AI-driven combination of variables with CT-based biomarkers offers perspectives for optimal patient management given the shortage of intensive care beds and ventilators.
△ Less
Submitted 20 April, 2020;
originally announced April 2020.
-
Nanoscale distribution of magnetic anisotropies in bimagnetic soft core-hard shell MnFe$_2$O$_4$@CoFe$_2$O$_4$ nanoparticles
Authors:
Niéli Daffé,
Marcin Sikora,
Mauro Rovezzi,
Nadejda Bouldi,
Véronica Gavrilov,
Sophie Neveu,
Fadi Choueikani,
Philippe Ohresser,
Vincent Dupuis,
Dario Taverna,
Alexandre Gloter,
Marie-Anne Arrio,
Philippe Sainctavit,
Amélie Juhin
Abstract:
The nanoscale distribution of magnetic anisotropies was measured in core@shell MnFe$_2$O$_4$@CoFe$_2$O$_4$ 7.0 nm particles using a combination of element selective magnetic spectroscopies with different probing depths. As this picture is not accessible by any other technique, emergent magnetic properties were revealed. The coercive field is not constant in a whole nanospinel. The very thin (0.5 n…
▽ More
The nanoscale distribution of magnetic anisotropies was measured in core@shell MnFe$_2$O$_4$@CoFe$_2$O$_4$ 7.0 nm particles using a combination of element selective magnetic spectroscopies with different probing depths. As this picture is not accessible by any other technique, emergent magnetic properties were revealed. The coercive field is not constant in a whole nanospinel. The very thin (0.5 nm) CoFe$_2$O$_4$ hard shell imposes a strong magnetic anisotropy to the otherwise very soft MnFe$_2$O$_4$ core: a large gradient in coercivity was measured inside the MnFe$_2$O$_4$ core with lower values close to the interface region, while the inner core presents a substantial coercive field (0.54 T) and a very high remnant magnetization (90% of the magnetization at saturation).
△ Less
Submitted 14 September, 2017; v1 submitted 13 October, 2016;
originally announced October 2016.
-
Synthesis of Fe3O4@CoFe2O4@MnFe2O4 trimagnetic core/shell/shell nanoparticles
Authors:
Véronica Gavrilov-Isaac,
Sophie Neveu,
Vincent Dupuis,
Delphine Talbot,
Valérie Cabuil
Abstract:
We report the synthesis and characterization of original 'multishell' magnetic nanoparticles made of a soft core (magnetite) covered with two successive shells: a hard one (cobalt ferrite) and then a soft one (manganese ferrite). Our results show that contrary to expectations from simple models in which the coercivity of a bimagnetic core/shell nanoparticle depends simply on the proportion of soft…
▽ More
We report the synthesis and characterization of original 'multishell' magnetic nanoparticles made of a soft core (magnetite) covered with two successive shells: a hard one (cobalt ferrite) and then a soft one (manganese ferrite). Our results show that contrary to expectations from simple models in which the coercivity of a bimagnetic core/shell nanoparticle depends simply on the proportion of soft and hard phases within that particle, the addition of a second shell made of a soft ferrite material enhances the coercivity. Taking into account the interactions between the shells themselves and the core may thus be necessary to understand the magnetic properties of such nanoparticles.
△ Less
Submitted 9 February, 2014;
originally announced February 2014.
-
Photonic Hall Effect in ferrofluids: Theory and Experiments
Authors:
D. Lacoste,
F. Donatini,
S. Neveu,
J. A. Serughetti,
B. A. Van Tiggelen
Abstract:
An experimental and theoretical study on the Photonic Hall Effect (PHE) in liquid and gelled samples of ferrofluids is presented. The ferrofluids are aqueous colloidal suspensions of Fe(_{2})CoO(_{4}) particles, which can be considered as anisotropic and absorbing Rayleigh scatterers.
The PHE is found to be produced by the orientation of the magnetic moments of the particles, as is also the ca…
▽ More
An experimental and theoretical study on the Photonic Hall Effect (PHE) in liquid and gelled samples of ferrofluids is presented. The ferrofluids are aqueous colloidal suspensions of Fe(_{2})CoO(_{4}) particles, which can be considered as anisotropic and absorbing Rayleigh scatterers.
The PHE is found to be produced by the orientation of the magnetic moments of the particles, as is also the case for the Faraday effect. The dependence of the PHE with respect to the concentration of the scatterers, the magnetic field and the polarization of the incident light is measured in liquid and in gelled samples and is compared to a simple model based on the use of a scattering matrix and the single scattering approximation.
△ Less
Submitted 6 April, 2000;
originally announced April 2000.