-
Experimental benchmark data for Monte Carlo simulated radiation effects of gold nanoparticles. Part II: Comparison of measured and simulated electron spectra from gold nanofoils
Authors:
Jorge Borbinha,
Liset de la Fuente Rosales,
Philine Hepperle,
Heidi Nettelbeck,
Woon Yong Baek,
Salvatore Di Maria,
Hans Rabus
Abstract:
Electron emission spectra of a thin gold foil after photon interaction were measured over the energy range between 50 eV and 9500 eV to provide reference data for Monte Carlo radiation-transport simulations. Experiments were performed with the HAXPES spectrometer at the PETRA III high-brilliance beamline P22 at DESY (Hamburg, Germany) for photon energies just below and above each of the gold L-edg…
▽ More
Electron emission spectra of a thin gold foil after photon interaction were measured over the energy range between 50 eV and 9500 eV to provide reference data for Monte Carlo radiation-transport simulations. Experiments were performed with the HAXPES spectrometer at the PETRA III high-brilliance beamline P22 at DESY (Hamburg, Germany) for photon energies just below and above each of the gold L-edges, i.e., at 11.9 keV, 12.0 keV, 13.7 keV, 13.8 keV, 14.3 keV, and 14.4 keV. The data were analyzed to obtain the absolute values of the particle radiance of the emitted electrons per incident photon flux. Simulations of the experiment were performed using the Monte Carlo radiation-transport codes Penelope and Geant4. Comparison of the measured and simulated results shows good qualitative agreement. When simulation results are convolved with curves that take into account the effect of lifetime broadening, line shapes of photoelectron and Auger peaks similar to those observed experimentally are obtained. On an absolute scale, the experiments tend to give higher electron radiance values at the lower photon energies studied as well as at the higher photon energies for electron energies below the energy of the Au L3 photoelectron. This is attributed to the linear polarization of the photon beam in the experiments which is not considered in the simulation codes.
△ Less
Submitted 9 April, 2023; v1 submitted 14 December, 2022;
originally announced December 2022.
-
A new Standard DNA damage (SDD) data format
Authors:
J. Schuemann,
A. McNamara,
J. W. Warmenhoven,
N. T. Henthorn,
K. Kirkby,
M. J. Merchant,
S. Ingram,
H. Paganetti,
KD. Held,
J. Ramos-Mendez,
B. Faddegon,
J. Perl,
D. Goodhead,
I. Plante,
H. Rabus,
H. Nettelbeck,
W. Friedland,
P. Kundrat,
A. Ottolenghi,
G. Baiocco,
S. Barbieri,
M. Dingfelder,
S. Incerti,
C. Villagrasa,
M. Bueno
, et al. (26 additional authors not shown)
Abstract:
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Ca…
▽ More
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Carlo codes have been developed to simulate damage induction at the DNA scale, while at the same time various groups have developed models that describe DNA repair processes with varying levels of detail. These repair models are intrinsically linked to the damage model employed in their development, making it difficult to disentangle systematic effects in either part of the modelling chain. The modelling chain typically consists of track structure Monte Carlo simulations of the physics interactions creating direct damages to the DNA; followed by simulations of the production and initial reactions of chemical species causing indirect damages. After the DNA damage induction, DNA repair models combine the simulated damage patterns with biological models to determine the biological consequences of the damage. We propose a new Standard data format for DNA Damage to unify the interface between the simulation of damage induction and the biological modelling of cell repair processes. Such a standard greatly facilitates inter model comparisons, providing an ideal environment to tease out model assumptions and identify persistent, underlying mechanisms. Through inter model comparisons, this unified standard has the potential to greatly advance our understanding of the underlying mechanisms of radiation induced DNA damage and the resulting observable biological effects.
△ Less
Submitted 11 January, 2022;
originally announced January 2022.
-
Intercomparison of micro- and nanodosimetry Monte Carlo simulations: an approach to assess the influence of different cross-sections for low-energy electrons on the dispersion of results
Authors:
Carmen Villagrasa,
Hans Rabus,
Giorgio Baiocco,
Yann Perrot,
Alessio Parisi,
Lara Struelens,
Rui Qiu,
Michael Beuve,
Floriane Poignant,
Marcin Pietrzak,
Heidi Nettelbeck
Abstract:
An intercomparison of microdosimetric and nanodosimetric quantities simulated Monte Carlo codes is in progress with the goal of assessing the uncertainty contribution to simulated results due to the uncertainties of the electron interaction cross-sections used in the codes. In the first stage of the intercomparison, significant discrepancies were found for nanodosimetric quantities as well as for…
▽ More
An intercomparison of microdosimetric and nanodosimetric quantities simulated Monte Carlo codes is in progress with the goal of assessing the uncertainty contribution to simulated results due to the uncertainties of the electron interaction cross-sections used in the codes. In the first stage of the intercomparison, significant discrepancies were found for nanodosimetric quantities as well as for microdosimetric simulations of a radiation source placed at the surface of a spherical water scoring volume. This paper reports insight gained from further analysis, including additional results for the microdosimetry case where the observed discrepancies in the simulated distributions could be traced back to the difference between track-structure and condensed-history approaches. Furthermore, detailed investigations into the sensitivity of nanodosimetric distributions to alterations in inelastic electron scattering cross-sections are presented which were conducted in the lead up to the definition of an approach to be used in the second stage of the intercomparison to come. The suitability of simulation results for assessing the sought uncertainty contributions from cross-sections is discussed and a proposed framework is described.
△ Less
Submitted 25 October, 2021; v1 submitted 18 August, 2021;
originally announced August 2021.
-
Consistency checks of results from a Monte Carlo code intercomparison for emitted electron spectra and energy deposition around a single gold nanoparticle irradiated by X-rays
Authors:
H. Rabus,
W. B. Li,
H. Nettelbeck,
J. Schuemann,
C. Villagrasa,
M. Beuve,
S. Di Maria,
B. Heide,
A. P. Klapproth,
F. Poignant,
R. Qiu,
B. Rudek
Abstract:
Organized by the European Radiation Dosimetry Group (EURADOS), a Monte Carlo code intercomparison exercise was conducted where participants simulated the emitted electron spectra and energy deposition around a single gold nanoparticle (GNP) irradiated by X-rays. In the exercise, the participants scored energy imparted in concentric spherical shells around a spherical volume filled with gold or wat…
▽ More
Organized by the European Radiation Dosimetry Group (EURADOS), a Monte Carlo code intercomparison exercise was conducted where participants simulated the emitted electron spectra and energy deposition around a single gold nanoparticle (GNP) irradiated by X-rays. In the exercise, the participants scored energy imparted in concentric spherical shells around a spherical volume filled with gold or water as well as the spectral distribution of electrons leaving the GNP. Initially, only the ratio of energy deposition with and without GNP was to be reported. During the evaluation of the exercise, however, the data for energy deposition in the presence and absence of the GNP were also requested. A GNP size of 50 nm and 100 nm diameter was considered as well as two different X-ray spectra (50 kVp and 100kVp). This introduced a redundancy that can be used to cross-validate the internal consistency of the simulation results. In this work, evaluation of the reported results is presented in terms of integral quantities that can be benchmarked against values obtained from physical properties of the radiation spectra and materials involved. The impact of different interaction cross-section datasets and their implementation in the different Monte Carlo codes is also discussed.
△ Less
Submitted 23 November, 2021; v1 submitted 15 May, 2021;
originally announced May 2021.
-
Intercomparison of Monte Carlo calculated dose enhancement ratios for gold nanoparticles irradiated by X-rays: assessing the uncertainty and correct methodology for extended beams
Authors:
H. Rabus,
W. B. Li,
C. Villagrasa,
J. Schuemann,
P. A. Hepperle,
L. de la Fuente Rosales,
M. Beuve,
S. Di Maria,
A. P. Klapproth,
C. Y. Li,
F. Poignant,
B. Rudek,
H. Nettelbeck
Abstract:
Results of a Monte Carlo code intercomparison exercise for simulations of the dose enhancement from a gold nanoparticle (GNP) irradiated by X-rays have been recently reported. To highlight potential differences between codes, the dose enhancement ratios (DERs) were shown for the narrow-beam geometry used in the simulations, which leads to values significantly higher than unity over distances in th…
▽ More
Results of a Monte Carlo code intercomparison exercise for simulations of the dose enhancement from a gold nanoparticle (GNP) irradiated by X-rays have been recently reported. To highlight potential differences between codes, the dose enhancement ratios (DERs) were shown for the narrow-beam geometry used in the simulations, which leads to values significantly higher than unity over distances in the order of several tens of micrometers from the GNP surface. As it has come to our attention that the figures in our paper have given rise to misinterpretation as showing 'the' DERs of GNPs under diagnostic X-ray irradiation, this article presents estimates of the DERs that would have been obtained with realistic radiation field extensions and presence of secondary particle equilibrium (SPE). These DER values are much smaller than those for a narrow-beam irradiation shown in our paper, and significant dose enhancement is only found within a few hundred nanometers around the GNP. The approach used to obtain these estimates required the development of a methodology to identify and, where possible, correct results from simulations whose implementation deviated from the initial exercise definition. Based on this methodology, literature on Monte Carlo simulated DERs has been critically assessed.
△ Less
Submitted 19 July, 2021; v1 submitted 11 December, 2020;
originally announced December 2020.