-
New approaches to particle induced prompt gamma imaging
Authors:
Mythra Varun Nemallapudi,
Atiq Ur Rahman,
Vanny Marantha Sihotang,
Thien Cong Tran,
Hsin-Hon Lin,
Chih-Hsun Lin,
Ming-Lee Chu,
Augustine Ei-Fong Chen,
Shih-Chang Lee
Abstract:
The distribution of the prompt gamma emissions induced by proton interactions in a target material carries information concerning the proton range and target composition. In order to image prompt gamma we present different approaches. The first approach is based on knife-edge collimator utilized in tandem with a compact PET type detector in order to verify proton range by measuring the depth distr…
▽ More
The distribution of the prompt gamma emissions induced by proton interactions in a target material carries information concerning the proton range and target composition. In order to image prompt gamma we present different approaches. The first approach is based on knife-edge collimator utilized in tandem with a compact PET type detector in order to verify proton range by measuring the depth distribution of prompt gamma relying on Compton scattered events. A second approach aims at unambiguously identifying the presence of protons in a region of interest by introducing a bio-compatible fiducial marker in the patient and measuring the characteristic prompt gamma of the marker against background material. A third approach illustrates a novel design for position sensitive gamma imaging with a millimeter level adjustable position resolution with a high detection efficiency which is a step towards 3D prompt gamma imaging, useful to better understand the target composition. Simulations of the designs were performed using GATE/Geant4 Monte Carlo framework. Experimental tests on fiducial marker were conducted at the proton facilities in INER and Chang Gung Memorial hospital. Using the knife-edge PET approach a range verification of 0.7 mm can be achieved for shifts within 1 cm near the tumor region and up to 4 mm for shifts within a 4 cm window. For the fiducial marker approach we identify 984 keV as the dominant prompt gamma and show that for the 50% relative PG intensity, the R80 position falls within a 3 mm thick 48Ti marker. Using the position sensitive gamma imaging approach we present a feasible design to achieve spatial resolution values of 2.6 mm with a detection efficiency of 5.4E-6 at 6.1 MeV and up to eight depth positions in a single run. The relative advantage of these methods and the challenges in the implementation are discussed.
△ Less
Submitted 25 July, 2022; v1 submitted 30 April, 2022;
originally announced May 2022.
-
Direct map** from PET coincidence data to proton-dose and positron activity using a deep learning approach
Authors:
Atiq. Ur. Rahman,
Mythra Varun. Nemallapudi,
Cheng-Ying. Chou,
Shih-Chang Lee,
Chih-Hsun. Lin
Abstract:
$Objective$. Obtaining the intrinsic dose distributions in particle therapy is a challenging problem that needs to be addressed by imaging algorithms to take advantage of secondary particle detectors. In this work, we investigate the utility of deep learning methods for achieving direct map** from detector data to the intrinsic dose distribution.
$Approach…
▽ More
$Objective$. Obtaining the intrinsic dose distributions in particle therapy is a challenging problem that needs to be addressed by imaging algorithms to take advantage of secondary particle detectors. In this work, we investigate the utility of deep learning methods for achieving direct map** from detector data to the intrinsic dose distribution.
$Approach$. We performed Monte Carlo simulations using GATE/Geant4 10.4 simulation toolkits to generate a dataset using human CT phantom irradiated with high-energy protons and imaged with compact in-beam PET for realistic beam delivery in a single-fraction ($\sim$2Gy). We developed a neural network model based on conditional generative adversarial networks to generate dose maps conditioned on coincidence distributions in the detector. The model performance is evaluated by the mean relative error, absolute dose fraction difference, and shift in Bragg peak position.
$Main$ $results$. The relative deviation in the dose and range of the distributions predicted by the model from the true values for mono-energetic irradiation between 50 MeV and 122 MeV lie within 1% and 2%, respectively. This was achieved using $\mathrm{10^5}$ coincidences acquired five minutes after irradiation. The relative deviation in the dose and range for spread-out Bragg peak distributions were within 1% and 2.6% uncertainties, respectively. $Significance$. An important aspect of this study is the demonstration of a method for direct map** from detector counts to dose domain using the low count data of compact detectors suited for practical implementation in particle therapy. Including additional prior information in the future can further expand the scope of our model and also extend its application to other areas of medical imaging.
△ Less
Submitted 14 August, 2022; v1 submitted 29 April, 2022;
originally announced April 2022.
-
A dynamic method for charging-up calculations: the case of GEM
Authors:
P. M. M. Correia,
C. A. B. Oliveira,
C. D. R. Azevedo,
A. L. M. Silva,
R. Veenhof,
Mythra Varun Nemallapudi,
J. F. C. A. Veloso
Abstract:
The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not been completely successful. Namely, the gain stability over time has not been fully understood. Charging-up of the insulator surfaces have been pointed as one o…
▽ More
The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not been completely successful. Namely, the gain stability over time has not been fully understood. Charging-up of the insulator surfaces have been pointed as one of the responsible for the difference between experimental and Monte Carlo results. This work describes two iterative methods to simulate the charging-up in one MPGD device, the Gas Electron Multiplier (GEM). The first method uses a constant step for avalanches time evolution, very detailed, but slower to compute. The second method uses a dynamic step that improves the computing time. Good agreement between both methods was reached. Despite of comparison with experimental results shows that charging-up plays an important role in detectors operation, should not be the only responsible for the difference between simulated and measured effective gain, but explains the time evolution in the effective gain.
△ Less
Submitted 22 January, 2014; v1 submitted 16 January, 2014;
originally announced January 2014.
-
Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
Y. Assran,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti,
L. Franconi
, et al. (34 additional authors not shown)
Abstract:
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly t…
▽ More
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly technique, we built four full-scale Triple-GEM muon detectors for the inner ring of the first muon endcap station. We plan to install these or further improved versions in CMS during the first long LHC shutdown in 2013/14 for continued testing. These detectors are designed for the stringent rate and resolution requirements in the increasingly hostile environments expected at CMS after the second long LHC shutdown in 2018/19. The new prototypes were studied in muon/pion beams at the CERN SPS. We discuss our experience with constructing the new full-scale production prototypes and present preliminary performance results from the beam test. We also tested smaller Triple-GEM prototypes with zigzag readout strips with 2 mm pitch in these beams and measured a spatial resolution of 73 microns. This readout offers a potential reduction of channel count and consequently electronics cost for this system while maintaining high spatial resolution.
△ Less
Submitted 16 November, 2012;
originally announced November 2012.
-
Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System
Authors:
M. Tytgat,
A. Marinov,
N. Zaganidis,
Y. Ban,
J. Cai,
H. Teng,
A. Mohapatra,
T. Moulik,
M. Abbrescia,
A. Colaleo,
G. de Robertis,
F. Loddo,
M. Maggi,
S. Nuzzo,
S. A. Tupputi,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Raffone,
G. Saviano,
M. G. Bagliesi,
R. Cecchi,
G. Magazzu,
E. Oliveri
, et al. (34 additional authors not shown)
Abstract:
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas dete…
▽ More
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$η$ muon system
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
M. G. Bagliesi,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
R. Cecchi,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti
, et al. (33 additional authors not shown)
Abstract:
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The const…
▽ More
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The construction of large-area GEM detectors is challenging both from the technological and production aspects. In view of the CMS upgrade we have designed and built the largest full-size Triple-GEM muon detector, which is able to meet the stringent requirements given the hostile environment at the high-luminosity LHC. Measurements were performed during several test beam campaigns at the CERN SPS in 2010 and 2011. The main issues under study are efficiency, spatial resolution and timing performance with different inter-electrode gap configurations and gas mixtures. In this paper results of the performance of the prototypes at the beam tests will be discussed.
△ Less
Submitted 30 November, 2011; v1 submitted 21 November, 2011;
originally announced November 2011.