-
ASL to PET Translation by a Semi-supervised Residual-based Attention-guided Convolutional Neural Network
Authors:
Sahar Yousefi,
Hessam Sokooti,
Wouter M. Teeuwisse,
Dennis F. R. Heijtel,
Aart J. Nederveen,
Marius Staring,
Matthias J. P. van Osch
Abstract:
Positron Emission Tomography (PET) is an imaging method that can assess physiological function rather than structural disturbances by measuring cerebral perfusion or glucose consumption. However, this imaging technique relies on injection of radioactive tracers and is expensive. On the contrary, Arterial Spin Labeling (ASL) MRI is a non-invasive, non-radioactive, and relatively cheap imaging techn…
▽ More
Positron Emission Tomography (PET) is an imaging method that can assess physiological function rather than structural disturbances by measuring cerebral perfusion or glucose consumption. However, this imaging technique relies on injection of radioactive tracers and is expensive. On the contrary, Arterial Spin Labeling (ASL) MRI is a non-invasive, non-radioactive, and relatively cheap imaging technique for brain hemodynamic measurements, which allows quantification to some extent. In this paper we propose a convolutional neural network (CNN) based model for translating ASL to PET images, which could benefit patients as well as the healthcare system in terms of expenses and adverse side effects. However, acquiring a sufficient number of paired ASL-PET scans for training a CNN is prohibitive for many reasons. To tackle this problem, we present a new semi-supervised multitask CNN which is trained on both paired data, i.e. ASL and PET scans, and unpaired data, i.e. only ASL scans, which alleviates the problem of training a network on limited paired data. Moreover, we present a new residual-based-attention guided mechanism to improve the contextual features during the training process. Also, we show that incorporating T1-weighted scans as an input, due to its high resolution and availability of anatomical information, improves the results. We performed a two-stage evaluation based on quantitative image metrics by conducting a 7-fold cross validation followed by a double-blind observer study. The proposed network achieved structural similarity index measure (SSIM), mean squared error (MSE) and peak signal-to-noise ratio (PSNR) values of $0.85\pm0.08$, $0.01\pm0.01$, and $21.8\pm4.5$ respectively, for translating from 2D ASL and T1-weighted images to PET data. The proposed model is publicly available via https://github.com/yousefis/ASL2PET.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
Improved unsupervised physics-informed deep learning for intravoxel incoherent motion modeling and evaluation in pancreatic cancer patients
Authors:
Misha P. T. Kaandorp,
Sebastiano Barbieri,
Remy Klaassen,
Hanneke W. M. van Laarhoven,
Hans Crezee,
Peter T. While,
Aart J. Nederveen,
Oliver J. Gurney-Champion
Abstract:
${\bf Purpose}$: Earlier work showed that IVIM-NET$_{orig}$, an unsupervised physics-informed deep neural network, was more accurate than other state-of-the-art intravoxel-incoherent motion (IVIM) fitting approaches to DWI. This study presents an improved version: IVIM-NET$_{optim}$, and characterizes its superior performance in pancreatic ductal adenocarcinoma (PDAC) patients. ${\bf Method}…
▽ More
${\bf Purpose}$: Earlier work showed that IVIM-NET$_{orig}$, an unsupervised physics-informed deep neural network, was more accurate than other state-of-the-art intravoxel-incoherent motion (IVIM) fitting approaches to DWI. This study presents an improved version: IVIM-NET$_{optim}$, and characterizes its superior performance in pancreatic ductal adenocarcinoma (PDAC) patients. ${\bf Method}$: In simulations (SNR=20), the accuracy, independence and consistency of IVIM-NET were evaluated for combinations of hyperparameters (fit S0, constraints, network architecture, # hidden layers, dropout, batch normalization, learning rate), by calculating the NRMSE, Spearman's $ρ$, and the coefficient of variation (CV$_{NET}$), respectively. The best performing network, IVIM-NET$_{optim}$ was compared to least squares (LS) and a Bayesian approach at different SNRs. IVIM-NET$_{optim}$'s performance was evaluated in 23 PDAC patients. 14 of the patients received no treatment between scan sessions and 9 received chemoradiotherapy between sessions. Intersession within-subject standard deviations (wSD) and treatment-induced changes were assessed. ${\bf Results}$: In simulations, IVIM-NET$_{optim}$ outperformed IVIM-NET$_{orig}$ in accuracy (NRMSE(D)=0.18 vs 0.20; NMRSE(f)=0.22 vs 0.27; NMRSE(D*)=0.39 vs 0.39), independence ($ρ$(D*,f)=0.22 vs 0.74) and consistency (CV$_{NET}$ (D)=0.01 vs 0.10; CV$_{NET}$ (f)=0.02 vs 0.05; CV$_{NET}$ (D*)=0.04 vs 0.11). IVIM-NET$_{optim}$ showed superior performance to the LS and Bayesian approaches at SNRs<50. In vivo, IVIM-NET$_{optim}$ sshowed significantly less noisy parameter maps with lower wSD for D and f than the alternatives. In the treated cohort, IVIM-NET$_{optim}$ detected the most individual patients with significant parameter changes compared to day-to-day variations. ${\bf Conclusion}$: IVIM-NET$_{optim}$ is recommended for IVIM fitting to DWI data.
△ Less
Submitted 23 March, 2021; v1 submitted 3 November, 2020;
originally announced November 2020.
-
Compressed Sensing MRI With Variable Density Averaging (CS-VDA) Outperforms Full Sampling At Low SNR
Authors:
Jasper Schoormans,
Gustav J. Strijkers,
Anders C. Hansen,
Aart J. Nederveen,
Bram F. Coolen
Abstract:
We investigated whether a combination of k-space undersampling and variable density averaging enhances image quality for low-SNR MRI acquisitions. We implemented 3D Cartesian k-space prospective undersampling with a variable number of averages for each k-line. The performance of this compressed sensing with variable-density averaging (CS-VDA) method was evaluated in retrospective analysis of fully…
▽ More
We investigated whether a combination of k-space undersampling and variable density averaging enhances image quality for low-SNR MRI acquisitions. We implemented 3D Cartesian k-space prospective undersampling with a variable number of averages for each k-line. The performance of this compressed sensing with variable-density averaging (CS-VDA) method was evaluated in retrospective analysis of fully sampled phantom MRI measurements, as well as for prospectively accelerated in vivo 3D brain and knee MRI scans. Both phantom and in vivo results showed that acquisitions using the CS-VDA approach resulted in better image quality as compared to full sampling of k-space in the same scan time. Specifically, CS-VDA with a higher number of averages in the center of k-space resulted in the best image quality, apparent from increased anatomical detail with preserved soft-tissue contrast. This novel approach will facilitate improved image quality of inherently low SNR data, such as those with high-resolution or specific contrast-weightings with low SNR efficiency.
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
A scale space based algorithm for automated segmentation of single shot tagged MRI of shearing deformation
Authors:
André M. J. Sprengers,
Matthan W. A. Caan,
Kevin M. Moerman,
Aart J. Nederveen,
Rolf M. J. N. Lamerichs,
Jaap Stoker
Abstract:
Object This study proposes a scale space based algorithm for automated segmentation of single-shot tagged images of modest SNR. Furthermore the algorithm was designed for analysis of discontinuous or shearing types of motion, i.e. segmentation of broken tag patterns.
Materials and methods The proposed algorithm utilizes non-linear scale space for automatic segmentation of single-shot tagged imag…
▽ More
Object This study proposes a scale space based algorithm for automated segmentation of single-shot tagged images of modest SNR. Furthermore the algorithm was designed for analysis of discontinuous or shearing types of motion, i.e. segmentation of broken tag patterns.
Materials and methods The proposed algorithm utilizes non-linear scale space for automatic segmentation of single-shot tagged images. The algorithm's ability to automatically segment tagged shearing motion was evaluated in a numerical simulation and in vivo. A typical shearing deformation was simulated in a Shepp-Logan phantom allowing for quantitative evaluation of the algorithm's success rate as a function of both SNR and the amount of deformation. For a qualitative in vivo evaluation tagged images showing deformations in the calf muscles and eye movement in a healthy volunteer were acquired.
Results Both the numerical simulation and the in vivo tagged data demonstrated the algorithm's ability for automated segmentation of single-shot tagged MR provided that SNR of the images is above 10 and the amount of deformation does not exceed the tag spacing. The latter constraint can be met by adjusting the tag delay or the tag spacing.
Conclusion The scale space based algorithm for automatic segmentation of single-shot tagged MR enables the application of tagged MR to complex (shearing) deformation and the processing of datasets with relatively low SNR.
△ Less
Submitted 21 March, 2017;
originally announced March 2017.
-
Validation of SPAMM Tagged MRI Based Measurement of 3D Soft Tissue Deformation
Authors:
Kevin M. Moerman,
Andre M. J. Sprengers,
Ciaran K. Simms,
Rolf M. Lamerichs,
Jaap Stoker,
Aart J. Nederveen
Abstract:
This study presents and validates a novel (non-ECG-triggered) MRI sequence based on SPAtial Modulation of the Magnetization (SPAMM) to non-invasively measure 3D (quasi-static) soft tissue deformations using only six acquisitions (three static and three indentations). In current SPAMM tagged MRI approaches data is typically constructed from many repeated motion cycles. This has so far restricted it…
▽ More
This study presents and validates a novel (non-ECG-triggered) MRI sequence based on SPAtial Modulation of the Magnetization (SPAMM) to non-invasively measure 3D (quasi-static) soft tissue deformations using only six acquisitions (three static and three indentations). In current SPAMM tagged MRI approaches data is typically constructed from many repeated motion cycles. This has so far restricted its application to the measurement of highly repeatable and periodic movements (e.g. cardiac deformation). In biomechanical applications where soft tissue deformation is artificially induced, often by indentation, significant repeatability constraints exist and, for clinical applications, discomfort and health issues generally preclude a large number of repetitions.
△ Less
Submitted 22 April, 2016;
originally announced April 2016.
-
Validation of Continuously Tagged MRI for the Measurement of Dynamic 3D Skeletal Muscle Tissue Deformation
Authors:
Kevin M. Moerman,
Andre M. J. Sprengers,
Ciaran K. Simms,
Rolf M. Lamerichs,
Jaap Stoker,
Aart J. Nederveen
Abstract:
A SPAMM tagged MRI methodology is presented allowing continuous (3.3-3.6 Hz) sampling of 3D dynamic soft tissue deformation using non-segmented 3D acquisitions. The 3D deformation is reconstructed by the combination of 3 mutually orthogonal tagging directions, thus requiring only 3 repeated motion cycles. In addition a fully automatic post-processing framework is presented employing Gabor scale-sp…
▽ More
A SPAMM tagged MRI methodology is presented allowing continuous (3.3-3.6 Hz) sampling of 3D dynamic soft tissue deformation using non-segmented 3D acquisitions. The 3D deformation is reconstructed by the combination of 3 mutually orthogonal tagging directions, thus requiring only 3 repeated motion cycles. In addition a fully automatic post-processing framework is presented employing Gabor scale-space and filter-bank analysis for tag extrema segmentation and triangulated surface fitting aided by Gabor filter bank derived surface normals. Deformation is derived following tracking of tag surface triplet triangle intersections. The dynamic deformation measurements were validated using indentation tests (~20 mm deep at 12 mm/s) on a silicone gel soft tissue phantom containing contrasting markers which provide a reference measure of deformation. In addition, the techniques were evaluated in-vivo for dynamic skeletal muscle tissue deformation measurement during indentation of the biceps region of the upper arm in a volunteer.
△ Less
Submitted 20 April, 2016;
originally announced April 2016.
-
Skyrmions in disordered heterostructures}
Authors:
A. J. Nederveen,
Yuli V. Nazarov
Abstract:
We have investigated the effect of weak disorder on the ground state of a two dimensional electron gas in the quantum Hall regime at filling factors slightly deviating from unity. The skyrmions and antiskyrmions are found to be present even at filling factor $ν=1$. They may be strongly squeezed by the disorder. We have studied temperature effect on skyrmion density and size.
We have investigated the effect of weak disorder on the ground state of a two dimensional electron gas in the quantum Hall regime at filling factors slightly deviating from unity. The skyrmions and antiskyrmions are found to be present even at filling factor $ν=1$. They may be strongly squeezed by the disorder. We have studied temperature effect on skyrmion density and size.
△ Less
Submitted 31 August, 1998;
originally announced August 1998.