-
Sensitivity and environmental response of the CMS RPC gas gain monitoring system
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. L. Fabbri,
M. Giardoni,
B. Ortenzi,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
B. Ponzio,
A. Russo,
A. Colaleo,
F. Loddo,
M. Maggi,
A. Ranieri,
M. Abbrescia,
G. Iaselli,
B. Marangelli,
S. Natali,
S. Nuzzo,
G. Pugliese,
F. Romano,
G. Roselli,
R. Trentadue,
S. Tupputi
, et al. (13 additional authors not shown)
Abstract:
Results from the gas gain monitoring
(GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented.
The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.
Results from the gas gain monitoring
(GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented.
The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.
△ Less
Submitted 9 December, 2008;
originally announced December 2008.
-
The CMS RPC gas gain monitoring system: an overview and preliminary results
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Colonna,
L. Daniello,
F. L. Fabbri,
M. Giardoni,
B. Ortenzi,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
B. Ponzio,
C. Pucci,
A. Russo,
G. Roselli,
A. Colaleo,
F. Loddo,
M. Maggi,
A. Ranieri,
M. Abbrescia,
G. Iaselli,
B. Marangelli,
S. Natali,
S. Nuzzo,
G. Pugliese
, et al. (18 additional authors not shown)
Abstract:
The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determ…
▽ More
The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determination of any shift in working point conditions. The construction details and the first result of GGM commissioning are described.
△ Less
Submitted 5 December, 2008;
originally announced December 2008.
-
Temporal and diffraction effects in entanglement creation in an optical cavity
Authors:
S. Natali,
Z. Ficek
Abstract:
A practical scheme for entanglement creation between distant atoms located inside a single-mode optical cavity is discussed. We show that the degree of entanglement and the time it takes for the entanglement to reach its optimum value is a sensitive function the initial conditions and the position of the atoms inside the cavity mode. It is found that the entangled properties of the two atoms can…
▽ More
A practical scheme for entanglement creation between distant atoms located inside a single-mode optical cavity is discussed. We show that the degree of entanglement and the time it takes for the entanglement to reach its optimum value is a sensitive function the initial conditions and the position of the atoms inside the cavity mode. It is found that the entangled properties of the two atoms can readily be extracted from dynamics of a simple two-level system. Effectively, we engineer two coupled qubits whose the dynamics are analogous to that of a driven single two-level system. It is found that spatial variations of the coupling constants actually help to create transient entanglement which may appear on the time scale much longer than that predicted for the case of equal coupling constants. When the atoms are initially prepared in an entangled state, they may remain entangled for all times. We also find that the entanglement exhibits an interesting phenomenon of diffraction when the the atoms are located between the nodes and antinodes of the cavity mode. The diffraction pattern of the entanglement varies with time and we explain this effect in terms of the quantum property of complementarity, which is manifested as a tradeoff between the knowledge of energy of the exchanged photon versus the evolution time of the system.
△ Less
Submitted 18 April, 2007;
originally announced April 2007.
-
Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC
Authors:
M. Abbrescia,
A. Colaleo,
R. Guida,
G. Iaselli,
R. Liuzzi,
F. Loddo,
M. Maggi,
B. Marangelli,
S. Natali,
S. Nuzzo,
G. Pugliese,
A. Ranieri,
F. Romano,
R. Trentadue,
L. Benussi,
M. Bertani,
S. Bianco,
M. A. Caponero,
D. Colonna,
D. Donisi,
F. L. Fabbri,
F. Felli,
M. Giardoni B. Ortenzi,
M. Pallotta,
A. Paolozzi
, et al. (16 additional authors not shown)
Abstract:
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor…
▽ More
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.
△ Less
Submitted 30 December, 2006;
originally announced January 2007.
-
A puzzling Mule Coin from the Parabita Hoard: a Material Characterisation
Authors:
G. Giovannelli,
S. Natali,
B. Bozzini,
D. Manno,
G. Micocci,
A. Serra,
G. Sarcinelli,
A. Siciliano,
R. Vitale
Abstract:
In this research, we report on the compositional, microstructural and crystallographic properties of a lead coin which has been regarded for many years as a genuine silver coin minted in the Southern Italy in the course of the 4th century BC. The material characterisation of this object allowed detecting an ancient forging technology, not previously reported, which was meant for the silvering of…
▽ More
In this research, we report on the compositional, microstructural and crystallographic properties of a lead coin which has been regarded for many years as a genuine silver coin minted in the Southern Italy in the course of the 4th century BC. The material characterisation of this object allowed detecting an ancient forging technology, not previously reported, which was meant for the silvering of lead substrates The data collected have disclosed a contemporary counterfeiting procedure based on a metal coating process onto a Pb substrate. This coating has been identified as a bi-layer with a Cu innermost and an Ag outermost visible layer. As far as the coating application technique is concerned, the gathered evidence has clearly indicated that the original appearance of this artifact cannot be explained in terms of any of the established methods for the growth of an artificially silvered coating in classical antiquity. This technology is now being explained in terms of modern, fully non destructive scientific methods.
△ Less
Submitted 16 March, 2006;
originally announced March 2006.