-
LLRF upgrade status at the KEK Photon Factory 2.5 GeV ring
Authors:
D. Naito,
N. Yamamoto,
T. Takahashi,
A. Motomura,
S. Sakanaka
Abstract:
In 2023, we are replacing the LLRF system for the KEK-PF 2.5 GeV ring. The new system is composed of digital boards such as eRTM, AMC, and μRTM, based on the MTCA.4 standard. In our system, we adopted the non-IQ direct sampling method for RF detection. We set the sampling frequency at 8/13 (307.75 MHz) of the RF frequency, where the denominator (13) is the divisor of the harmonic number (312) of t…
▽ More
In 2023, we are replacing the LLRF system for the KEK-PF 2.5 GeV ring. The new system is composed of digital boards such as eRTM, AMC, and μRTM, based on the MTCA.4 standard. In our system, we adopted the non-IQ direct sampling method for RF detection. We set the sampling frequency at 8/13 (307.75 MHz) of the RF frequency, where the denominator (13) is the divisor of the harmonic number (312) of the storage ring. This allows us to detect the transient variation of the cavity voltage that is synchronized with the beam revolution. We also plan to compensate for the voltage variation by implementing a feedforward technique. These functions will be useful in a double RF system for KEK future synchrotron light source. Production and installation of the new system were complete and the new system is under commissioning. In this presentation, we introduce our new system and report the upgrade status.
△ Less
Submitted 21 October, 2023;
originally announced October 2023.
-
Search for $K_L \!\to\! π^0 ν\overlineν$ and $K_L \!\to\! π^0 X^0$ Decays at the J-PARC KOTO Experiment
Authors:
KOTO Collaboration,
J. K. Ahn,
B. Beckford,
J. Beechert,
K. Bryant,
M. Campbell,
S. H. Chen,
J. Comfort,
K. Dona,
N. Hara,
H. Haraguchi,
Y. B. Hsiung,
M. Hutcheson,
T. Inagaki,
I. Kamiji,
N. Kawasaki,
E. J. Kim,
J. L. Kim,
Y. J. Kim,
J. W. Ko,
T. K. Komatsubara,
K. Kotera,
A. S. Kurilin,
J. W. Lee,
G. Y. Lim
, et al. (45 additional authors not shown)
Abstract:
A search for the rare decay $K_L \!\to\! π^0 ν\overlineν$ was performed. With the data collected in 2015, corresponding to $2.2 \times 10^{19}$ protons on target, a single event sensitivity of $( 1.30 \pm 0.01_{\rm stat} \pm 0.14_{\rm syst} ) \times 10^{-9}$ was achieved and no candidate events were observed. We set an upper limit of $3.0 \times 10^{-9}$ for the branching fraction of…
▽ More
A search for the rare decay $K_L \!\to\! π^0 ν\overlineν$ was performed. With the data collected in 2015, corresponding to $2.2 \times 10^{19}$ protons on target, a single event sensitivity of $( 1.30 \pm 0.01_{\rm stat} \pm 0.14_{\rm syst} ) \times 10^{-9}$ was achieved and no candidate events were observed. We set an upper limit of $3.0 \times 10^{-9}$ for the branching fraction of $K_L \!\to\! π^0 ν\overlineν$ at the 90% confidence level (C.L.), which improved the previous limit by almost an order of magnitude. An upper limit for $K_L \!\to\! π^0 X^0$ was also set as $2.4 \times 10^{-9}$ at the 90% C.L., where $X^0$ is an invisible boson with a mass of $135~{\rm MeV}/c^2$.
△ Less
Submitted 26 February, 2019; v1 submitted 23 October, 2018;
originally announced October 2018.
-
A Control System of New Magnet Power Converter for J-PARC Main Ring Upgrade
Authors:
Tetsushi Shimogawa,
Yoshinori Kurimoto,
Yuichi Morita,
Kazuki Miura,
Daichi Naito
Abstract:
Japan Proton Accelerator Research Complex (J-PARC) aims at a MW-class proton accelerator facility. One of the promising solutions for increasing the beam power of the Main Ring (MR) is converters of the main magnets with new ones for this upgrade. We have a plan to replace and develop the power converters of main magnets for this upgrade. According to develop the new power converter. We have devel…
▽ More
Japan Proton Accelerator Research Complex (J-PARC) aims at a MW-class proton accelerator facility. One of the promising solutions for increasing the beam power of the Main Ring (MR) is converters of the main magnets with new ones for this upgrade. We have a plan to replace and develop the power converters of main magnets for this upgrade. According to develop the new power converter. We have developed a new control system for the new power converters. This control system consists of four parts : the current measuring device, the feedback control system, the gate pulse generator and the slow control system. Considering a reproducibility in the mass-production and the facilitation of the control algorithm, the digital control system is adopted. We will report the design of this control system and some test result with a new power converter for small quadrupole magnets.
△ Less
Submitted 22 June, 2018;
originally announced June 2018.
-
Real-Time Betatron Tune Correction with the Precise Measurement of Magnet Current
Authors:
Yoshinori Kurimoto,
Tetsushi Shimogawa,
Daichi Naito
Abstract:
The betatron tune, which is defined as the number of transverse oscillations in one turn of a ring accelerator, is one of the most important parameters. An undesired betatron tune increases the amplitude of the transverse oscillation so that many particles are lost from the ring sooner than designed. Since a betatron tune is controlled by the magnetic fields in the ring, the ripple of the magnet c…
▽ More
The betatron tune, which is defined as the number of transverse oscillations in one turn of a ring accelerator, is one of the most important parameters. An undesired betatron tune increases the amplitude of the transverse oscillation so that many particles are lost from the ring sooner than designed. Since a betatron tune is controlled by the magnetic fields in the ring, the ripple of the magnet current directly displaces the betatron tune from its designated value. We have developed a system that corrects the betatron tune displacement using the measured magnet current at the J-PARC (Japan Proton Accelerator Research Complex) Main Ring. We adopted Field Programmable Gated Arrays (FPGA) to convert from the measured magnet current to the betatron tune in real time. Using the system, we have decreased the fluctuation of the betatron tune from 5.2e-4 to 3.3e-4 at the frequencies less than 250 Hz.
△ Less
Submitted 11 June, 2018;
originally announced June 2018.
-
A new search for the $K_{L} \to π^0 ν\overlineν$ and $K_{L} \to π^{0} X^{0}$ decays
Authors:
J. K. Ahn,
K. Y. Baek,
S. Banno,
B. Beckford,
B. Brubaker,
T. Cai,
M. Campbell,
C. Carruth,
S. H. Chen,
S. Chu,
J. Comfort,
Y. T. Duh,
T. Furukawa,
H. Haraguchi,
T. Hineno,
Y. B. Hsiung,
M. Hutcheson,
T. Inagaki,
M. Isoe,
E. Iwai,
T. Kamibayashi,
I. Kamiji,
N. Kawasaki,
E. J. Kim,
Y. J. Kim
, et al. (66 additional authors not shown)
Abstract:
We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to π^0 ν\overlineν$, in data from the first 100 hours of physics running in 2013 of the J-PARC KOTO experiment. One candidate event was observed while $0.34\pm0.16$ background events were expected. We set an upper limit of $5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level (C.L.). An upper limit of…
▽ More
We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to π^0 ν\overlineν$, in data from the first 100 hours of physics running in 2013 of the J-PARC KOTO experiment. One candidate event was observed while $0.34\pm0.16$ background events were expected. We set an upper limit of $5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level (C.L.). An upper limit of $3.7\times10^{-8}$ at the 90\% C.L. for the $K_{L} \to π^{0} X^{0}$decay was also set for the first time, where $X^{0}$ is an invisible particle with a mass of 135 MeV/$c^{2}$.
△ Less
Submitted 27 December, 2016; v1 submitted 12 September, 2016;
originally announced September 2016.
-
Development of a low-mass and high-efficiency charged particle detector
Authors:
D. Naito,
Y. Maeda,
N. Kawasaki,
T. Masuda,
H. Nanjo,
T. Nomura,
M. Sasaki,
N. Sasao,
S. Seki,
K. Shiomi,
Y. Tajima
Abstract:
We developed a low-mass and high-efficiency charged particle detector for an experimental study of the rare decay $K_L \rightarrow π^0 ν\barν$. The detector is important to suppress the background with charged particles to the level below the signal branching ratio predicted by the Standard Model (O(10$^{-11}$)). The detector consists of two layers of 3-mm-thick plastic scintillators with waveleng…
▽ More
We developed a low-mass and high-efficiency charged particle detector for an experimental study of the rare decay $K_L \rightarrow π^0 ν\barν$. The detector is important to suppress the background with charged particles to the level below the signal branching ratio predicted by the Standard Model (O(10$^{-11}$)). The detector consists of two layers of 3-mm-thick plastic scintillators with wavelength shifting fibers embedded and Multi Pixel Photon Counters for readout. We manufactured the counter and evaluated the performance such as light yield, timing resolution, and efficiency. With this design, we achieved the inefficiency per layer against penetrating charged particles to be less than $1.5 \times 10^{-5}$, which satisfies the requirement of the KOTO experiment determined from simulation studies.
△ Less
Submitted 17 December, 2015; v1 submitted 13 December, 2015;
originally announced December 2015.
-
Long-lived neutral-kaon flux measurement for the KOTO experiment
Authors:
T. Masuda,
J. K. Ahn,
S. Banno,
M. Campbell,
J. Comfort,
Y. T. Duh,
T. Hineno,
Y. B. Hsiung,
T. Inagaki,
E. Iwai,
N. Kawasaki,
E. J. Kim,
Y. J. Kim,
J. W. Ko,
T. K. Komatsubara,
A. S. Kurilin,
G. H. Lee,
J. W. Lee,
S. K. Lee,
G. Y. Lim,
J. Ma,
D. MacFarland,
Y. Maeda,
T. Matsumura,
R. Murayama
, et al. (32 additional authors not shown)
Abstract:
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$,…
▽ More
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.
△ Less
Submitted 7 January, 2016; v1 submitted 11 September, 2015;
originally announced September 2015.
-
An aerogel Cherenkov detector for multi-GeV photon detection with low sensitivity to neutrons
Authors:
Y. Maeda,
N. Kawasaki,
T. Masuda,
H. Morii,
D. Naito,
Y. Nakajima,
H. Nanjo,
T. Nomura,
N. Sasao,
S. Seki,
K. Shiomi,
T. Sumida,
Y. Tajima
Abstract:
We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result of Monte Carlo (MC) simulations, the efficiency for photons with the energy larger than 1 GeV is expected to be higher than 99.5% and that for 2 GeV/$c$ neutron…
▽ More
We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result of Monte Carlo (MC) simulations, the efficiency for photons with the energy larger than 1 GeV is expected to be higher than 99.5% and that for 2 GeV/$c$ neutrons less than 1%. The performance on the photon detection under such a large flux of neutrons was measured for a part of the detector. It was confirmed that the efficiency to photons with the energy $>$1 GeV was consistent with the MC expectation within 8.2% uncertainty.
△ Less
Submitted 22 December, 2014;
originally announced December 2014.