Skip to main content

Showing 1–5 of 5 results for author: Nagler, P C

.
  1. arXiv:2012.06549  [pdf, other

    astro-ph.IM

    Transition-edge sensor detectors for the Origins Space Telescope

    Authors: Peter C. Nagler, John E. Sadleir, Edward J. Wollack

    Abstract: The Origins Space Telescope is one of four flagship missions under study for the 2020 Astrophysics Decadal Survey. With a 5.9 m cold (4.5 K) telescope deployed from space, Origins promises unprecedented sensitivity in the near-, mid-, and far-infrared, from 2.8 - 588 $μ$m. This mandates the use of ultra-sensitive and stable detectors in all of the Origins instruments. At the present, no known dete… ▽ More

    Submitted 11 December, 2020; originally announced December 2020.

    Comments: 43 pages, 8 figures. Accepted for publication by the Journal of Astronomical Telescopes, Instruments, and Systems

  2. arXiv:2012.06543  [pdf, other

    astro-ph.IM physics.ins-det

    Demonstration of ultra-low noise equivalent power using a longitudinal proximity effect transition-edge sensor

    Authors: Peter C. Nagler, John E. Sadleir, Edward J. Wollack

    Abstract: Future far-infrared astronomy missions will need large arrays of detectors with exceptionally low noise-equivalent power (NEP), with some mission concepts calling for thousands of detectors with NEPs below a few $\times 10^{-20}$ W/$\sqrt{\mathrm{Hz}}$. Though much progress has been made toward meeting this goal, such detector systems do not exist today. In this work, we present a device that offe… ▽ More

    Submitted 11 December, 2020; originally announced December 2020.

    Comments: 11 pages, 3 figures

  3. arXiv:1903.09718  [pdf, other

    astro-ph.IM astro-ph.EP

    Observing exoplanets in the near-infrared from a high altitude balloon platform

    Authors: Peter C. Nagler, Billy Edwards, Brian Kilpatrick, Nikole K. Lewis, Pierre Maxted, C. Barth Netterfield, Vivien Parmentier, Enzo Pascale, Subhajit Sarkar, Gregory S. Tucker, Ingo Waldmann

    Abstract: Although there exists a large sample of known exoplanets, little spectroscopic data exists that can be used to study their global atmospheric properties. This deficiency can be addressed by performing phase-resolved spectroscopy -- continuous spectroscopic observations of a planet's entire orbit about its host star -- of transiting exoplanets. Planets with characteristics suitable for atmospheric… ▽ More

    Submitted 29 July, 2019; v1 submitted 22 March, 2019; originally announced March 2019.

    Comments: 18 pages, 9 figures. Accepted for publication by the Journal of Astronomical Instrumentation

    Journal ref: Journal of Astronomical Instrumentation, Volume 8, Issue 3, id. 1950011, 2019

  4. Multimode bolometer development for the PIXIE instrument

    Authors: Peter C. Nagler, Kevin T. Crowley, Kevin L. Denis, Archana M. Devasia, Dale J. Fixsen, Alan J. Kogut, George Manos, Scott Porter, Thomas R. Stevenson

    Abstract: The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances i… ▽ More

    Submitted 14 November, 2016; originally announced November 2016.

    Comments: 10 pages, 7 figures

    Journal ref: Proc. SPIE 9914, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VIII, 99141A (July 19, 2016)

  5. arXiv:1510.08089  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    Systematic effects in polarizing Fourier transform spectrometers for cosmic microwave background observations

    Authors: Peter C. Nagler, Dale J. Fixsen, Alan Kogut, Gregory S. Tucker

    Abstract: The detection of the primordial B-mode polarization signal of the cosmic microwave background (CMB) would provide evidence for inflation. Yet as has become increasingly clear, the detection of a such a faint signal requires an instrument with both wide frequency coverage to reject foregrounds and excellent control over instrumental systematic effects. Using a polarizing Fourier transform spectrome… ▽ More

    Submitted 27 October, 2015; originally announced October 2015.

    Comments: 19 pages, 11 figures. Accepted for publication in ApJS

    Journal ref: 2015 ApJS, 221, 21