-
Progress on an Electron Beam Profile Monitor at the Fermilab Main Injector
Authors:
R. Thurman-Keup,
T. Folan,
M. Mwaniki,
S. Sas-Pawlik
Abstract:
The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam intensities in the Main Injector (MI) that will exceed 2 MW. Measuring the transverse profiles of these high intensity beams in a ring requires non-invasive technique…
▽ More
The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam intensities in the Main Injector (MI) that will exceed 2 MW. Measuring the transverse profiles of these high intensity beams in a ring requires non-invasive techniques. The MI uses ionization profile monitors as its only profile system. An alternative technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. This type of device was installed in MI and initial studies of it have been previously presented. This paper will present the status and recent studies of the device utilizing different techniques.
△ Less
Submitted 2 October, 2023;
originally announced October 2023.
-
Time-drift Aware RF Optimization with Machine Learning Techniques
Authors:
R. Sharankova,
M. Mwaniki,
K. Seiya,
M. Wesley
Abstract:
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To operate high current beam, accelerators must minimize uncontrolled particle loss; this can be accomplished by minimizing beam longitudinal emittance via RF parameter optimization. However, RF tuning is required…
▽ More
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To operate high current beam, accelerators must minimize uncontrolled particle loss; this can be accomplished by minimizing beam longitudinal emittance via RF parameter optimization. However, RF tuning is required daily since the resonance frequency of the accelerating cavities is affected by ambient temperature and humidity variations and thus drifts with time. In addition, the energy and phase space distribution of particles emerging from the ion source are subject to fluctuations. Such drift is not unique to Fermilab, but rather affects most laboratories. We are exploring machine learning (ML) algorithms for automated RF tuning for 2 objectives: optimization of Linac output energy and phase oscillation correction, with an emphasis on time-drift aware modeling that can account for conditions changing over time.
△ Less
Submitted 10 July, 2023;
originally announced July 2023.
-
Diagnostics for Linac Optimization With Machine Learning
Authors:
R. Sharankova,
M. Mwaniki,
K. Seiya,
M. Wesley
Abstract:
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To counter fluctuations of Linac output due to various effects to be described below we are working on implementing dynamic longitudinal parameter optimization based on Machine Learning (ML). As inputs for the ML m…
▽ More
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To counter fluctuations of Linac output due to various effects to be described below we are working on implementing dynamic longitudinal parameter optimization based on Machine Learning (ML). As inputs for the ML model, signals from beam diagnostics have to be well understood and reliable. In this paper we discuss the status and plans for ML-based optimization as well as preliminary results of diagnostics studies.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
Operation of the H- Linac at FNAL
Authors:
K. Seiya,
T. Butler,
D. Jones,
V. Kapin,
K. Hartman,
S. Moua,
J. -F. Ostiguy,
R. Ridgway,
R. Sharankova,
B. Stanzil,
C. Y. Tan,
J. Walters,
M. Wesley,
M. Mwaniki
Abstract:
The Fermi National Accelerator Laboratory (FNAL) Linac has been in operation for 52 years. In approximately four years, it will be replaced by a new 800 MeV superconducting machine, the PIP-II SRF Linac. In the current configuration, the Linac delivers H- ions at 400 MeV and injects protons by charge exchange into the Booster synchrotron. Despite its age, the Linac is the most stable accelerator i…
▽ More
The Fermi National Accelerator Laboratory (FNAL) Linac has been in operation for 52 years. In approximately four years, it will be replaced by a new 800 MeV superconducting machine, the PIP-II SRF Linac. In the current configuration, the Linac delivers H- ions at 400 MeV and injects protons by charge exchange into the Booster synchrotron. Despite its age, the Linac is the most stable accelerator in the FNAL complex, reliably sending 22 mA in daily operations. We will discuss the status of the operation, beam studies, and plans.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
Fast Exact String to D-Texts Alignments
Authors:
Njagi Moses Mwaniki,
Erik Garrison,
Nadia Pisanti
Abstract:
In recent years, aligning a sequence to a pangenome has become a central problem in genomics and pangenomics. A fast and accurate solution to this problem can serve as a toolkit to many crucial tasks such as read-correction, Multiple Sequences Alignment (MSA), genome assemblies, variant calling, just to name a few. In this paper we propose a new, fast and exact method to align a string to a D-stri…
▽ More
In recent years, aligning a sequence to a pangenome has become a central problem in genomics and pangenomics. A fast and accurate solution to this problem can serve as a toolkit to many crucial tasks such as read-correction, Multiple Sequences Alignment (MSA), genome assemblies, variant calling, just to name a few. In this paper we propose a new, fast and exact method to align a string to a D-string, the latter possibly representing an MSA, a pan-genome or a partial assembly. An implementation of our tool dsa is publicly available at https://github.com/urbanslug/dsa
△ Less
Submitted 7 June, 2022;
originally announced June 2022.