Showing 1–2 of 2 results for author: Murugkar, S
-
High spatial resolution dosimetry with uncertainty analysis using Raman micro-spectroscopy readout of radiochromic films
Authors:
Connor Mcnairn,
Iymad Mansour,
Bryan Muir,
Rowan M. Thomson,
Sangeeta Murugkar
Abstract:
Purpose: The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro-spectroscopy scanning of radiochromic film (RCF). We generate dose calibration curves over an extended dose range from 0-50 Gy and with improved sensitivity to low (<2 Gy) doses, in addition to evaluating uncertainties. Methods: Samples of RCF (EBT3) were irradiated at a broad…
▽ More
Purpose: The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro-spectroscopy scanning of radiochromic film (RCF). We generate dose calibration curves over an extended dose range from 0-50 Gy and with improved sensitivity to low (<2 Gy) doses, in addition to evaluating uncertainties. Methods: Samples of RCF (EBT3) were irradiated at a broad dose-range of 0.03 Gy-50 Gy. Raman spectra were acquired with a custom-built Raman micro-spectroscopy setup involving a 500 mW, multimode 785 nm laser. The depth of focus of 34 um enabled the concurrent collection of Raman spectra from the RCF active layer and the polyester laminate. The pre-processed Raman spectra were normalized to the intensity of the 1614 cm-1 Raman peak from the polyester laminate that was unaltered by radiation. The experimental, fitting and total dose uncertainty was determined across the entire dose range for the dosimetry system of Raman micro-spectroscopy and RCF. Results: High resolution in the dose response of the RCF, even down to 0.03 Gy, was obtained in this study. The dynamic range of the calibration curves based on all three Raman peaks in the RCF extended up to 50 Gy with no saturation. At a spatial resolution of 30X30 um^2, the total uncertainty in estimating dose in the 0.5 Gy to 50 Gy dose range was [6 - 9]% for all three Raman calibration curves. This consisted of the experimental uncertainty of [5 - 8]%, and the fitting uncertainty of [2.5 - 4.5]%. Conclusions: The high spatial resolution experimental dosimetry technique based on Raman micro-spectroscopy and RCF presented here, could become useful for applications in, as well as for applications based on small field dosimetry.
△ Less
Submitted 4 May, 2021;
originally announced May 2021.
-
Measurement of the Orbital Angular Momentum Spectrum of Partially Coherent Fields using Double Angular Slit Interference
Authors:
Mehul Malik,
Sangeeta Murugkar,
Jonathan Leach,
Robert W. Boyd
Abstract:
We implement an interferometric method using two angular slits to measure the orbital angular momentum (OAM) mode spectrum of a partially coherent field. As the angular separation of the slits changes, an interference pattern for a particular OAM mode is obtained. The visibility of this interference pattern as a function of angular separation is equivalent to the angular correlation function of th…
▽ More
We implement an interferometric method using two angular slits to measure the orbital angular momentum (OAM) mode spectrum of a partially coherent field. As the angular separation of the slits changes, an interference pattern for a particular OAM mode is obtained. The visibility of this interference pattern as a function of angular separation is equivalent to the angular correlation function of the field. By Fourier transforming the angular correlation function obtained from the double angular slit interference, we are able to calculate the OAM spectrum of the partially coherent field. This method has potential application for characterizing the OAM spectrum in high-dimensional quantum information protocols.
△ Less
Submitted 16 November, 2012; v1 submitted 15 August, 2012;
originally announced August 2012.