-
Foundation Models in Augmentative and Alternative Communication: Opportunities and Challenges
Authors:
Ambra Di Paola,
Serena Muraro,
Roberto Marinelli,
Christian Pilato
Abstract:
Augmentative and Alternative Communication (AAC) are essential techniques that help people with communication disabilities. AAC demonstrates its transformative power by replacing spoken language with symbol sequences. However, to unlock its full potential, AAC materials must adhere to specific characteristics, placing the onus on educators to create custom-tailored materials and symbols. This pape…
▽ More
Augmentative and Alternative Communication (AAC) are essential techniques that help people with communication disabilities. AAC demonstrates its transformative power by replacing spoken language with symbol sequences. However, to unlock its full potential, AAC materials must adhere to specific characteristics, placing the onus on educators to create custom-tailored materials and symbols. This paper introduces AMBRA (Pervasive and Personalized Augmentative and Alternative Communication based on Federated Learning and Generative AI), an open platform that aims to leverage the capabilities of foundation models to tackle many AAC issues, opening new opportunities (but also challenges) for AI-enhanced AAC. We thus present a compelling vision--a roadmap towards a more inclusive society. By leveraging the capabilities of modern technologies, we aspire to not only transform AAC but also guide the way toward a world where communication knows no bounds.
△ Less
Submitted 16 January, 2024;
originally announced January 2024.
-
The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system
Authors:
Silvia Biondi,
Andrey Alexandrov,
Behcet Alpat,
Giovanni Ambrosi,
Stefano Argirò,
Rau Arteche Diaz,
Nazarm Bartosik,
Giuseppe Battistoni,
Nicola Belcari,
Elettra Bellinzona,
Maria Giuseppina Bisogni,
Graziano Bruni,
Pietro Carra,
Piergiorgio Cerello,
Esther Ciarrocchi,
Alberto Clozza,
Sofia Colombi,
Giovanni De Lellis,
Alberto Del Guerra,
Micol De Simoni,
Antonia Di Crescenzo,
Benedetto Di Ruzza,
Marco Donetti,
Yunsheng Dong,
Marco Durante
, et al. (70 additional authors not shown)
Abstract:
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experim…
▽ More
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experiment has been developed in such a way that the experimental setup is easily movable and fits the space limitations of the experimental and treatment rooms available in hadrontherapy treatment centers, where most of the data takings are carried out. The Trigger and Data Acquisition system needs to follow the same criteria and it should work in different laboratories and in different conditions. It has been designed to acquire the largest sample size with high accuracy in a controlled and online-monitored environment. The data collected are processed in real-time for quality assessment and are available to the DAQ crew and detector experts during data taking.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
Analysis of time-profiles with in-beam PET monitoring in charged particle therapy
Authors:
A. C. Kraan,
S. Muraro,
G. Battistoni,
N. Belcari,
M. G. Bisogni,
N. Camarlinghi,
A. Del Guerra,
A. Ferrari,
R. Kopec,
D. Krzempek,
M. Morrocchi,
P. Olko,
P. Sala,
K. Skowronska,
G. Sportelli,
A. Topi,
V. Rosso
Abstract:
Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability…
▽ More
Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability of MC predictions of space and time (decay rate) profiles shortly after irradiation, and we show how the decay rates can give an indication about the elements of which the phantom is made up.
Methods and Materials: Various phantoms were irradiated in clinical and near-clinical conditions at the Cyclotron Centre of the Bronowice proton therapy centre. PET data were acquired with a planar 16x16 cm$^2$ PET system. MC simulations of particle interactions and photon propagation in the phantoms were performed using the FLUKA code. The analysis included a comparison between experimental data and MC simulations of space and time profiles, as well as a fitting procedure to obtain the various isotope contributions in the phantoms.
Results and conclusions: There was a good agreement between data and MC predictions in 1-dimensional space and decay rate distributions. The fractions of $^{11}$C, $^{15}$O and $^{10}$C that were obtained by fitting the decay rates with multiple simple exponentials generally agreed well with the MC expectations. We found a small excess of $^{10}$C in data compared to what was predicted in MC, which was clear especially in the PE phantom.
△ Less
Submitted 28 September, 2018;
originally announced September 2018.
-
Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by $^4$He ion beams in a PMMA target
Authors:
M. Marafini,
R. Paramatti,
D. Pinci,
G. Battistoni,
F. Collamati,
E. De Lucia,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
I. Mattei,
S. Muraro,
L. Piersanti,
M. Rovituso,
A. Rucinski,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atom…
▽ More
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments - protons, deuterons, and tritons - produced by $^4$He ion beams of 102, 125 and 145 MeV/u energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the Treatment Planning Software being developed for clinical use of $^4$He beams in clinical routine and the relative benchmarking of Monte Carlo algorithm predictions.
△ Less
Submitted 29 August, 2016;
originally announced August 2016.
-
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle
Authors:
A. Rucinski,
E. De Lucia,
G. Battistoni,
F. Collamati,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
M. Marafini,
I. Mattei,
S. Muraro,
R. Paramatti,
L. Piersanti,
D. Pinci,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. T…
▽ More
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. The secondary yields of protons produced along the primary beam path in PMMA target were obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The measured charged secondary yields and emission profiles are in agreement with the results reported in literature and confirm the feasibility of ion beam therapy range monitoring using 12C ion beam. The feasibility of range monitoring using charged secondary particles is also suggested for 4He ion beam.
△ Less
Submitted 16 August, 2016;
originally announced August 2016.
-
Design of a new tracking device for on-line dose monitor in ion therapy
Authors:
Giacomo Traini,
Giuseppe Battistoni,
Angela Bollella,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Fernando Ferroni,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Ilaria Mattei,
Federico Miraglia,
Silvia Muraro,
Riccardo Paramatti,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Elena Solfaroli-Camillocci,
Marco Toppi,
Cecilia Voena,
Vincenzo Patera
Abstract:
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam in…
▽ More
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam interactions in the patient tissues. In fact, the charged particle emission shape can be correlated with the spatial dose release and the Bragg peak position. The detector uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a small calorimeter made of a pixelated Lutetium Fine Silicate crystal. Simulations have been performed to evaluate the achievable spatial resolution and a possible application of the device for the monitoring of the dose profile in a real treatment is presented.
△ Less
Submitted 28 July, 2016;
originally announced July 2016.
-
Secondary radiation measurements for particle therapy applications: prompt photons produced by $^{4}$He, $^{12}$C and $^{16}$O ion beams in a PMMA target
Authors:
Ilaria Mattei,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Silvia Muraro,
Riccardo Paramatti,
Vincenzo Patera,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Elena Solfaroli Camillocci,
Marco Toppi,
Giacomo Traini,
Cecilia Voena,
Giuseppe Battistoni
Abstract:
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of heli…
▽ More
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of helium and oxygen beams is growing due to their reduced multiple scattering inside the body and increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands for online dose monitoring techniques, crucial to improve the quality assurance of treatments. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Prompt photons are produced by nuclear de-excitation processes and, at present, different dose monitoring and beam range verification techniques based on the prompt γ detection have been proposed. It is hence of importance to perform the γ yield measurement in therapeutical-like conditions. In this paper we report the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a PMMA target. The measurements were performed at the Heidelberg Ion-beam Therapy center (HIT) with beams of different energies. A LYSO scintillator has been used as photon detector. The obtained γ yields for $^{12}$C ion beams are compared with results from literature, while no other results from $^{4}$He and $^{16}$O beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.
△ Less
Submitted 19 July, 2016; v1 submitted 26 May, 2016;
originally announced May 2016.
-
Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam
Authors:
C. Agodi,
G. Battistoni,
F. Bellini,
G. A. P. Cirrone,
F. Collamati,
G. Cuttone,
E. De Lucia,
M. De Napoli,
A. Di Domenico,
R. Faccini,
F. Ferroni,
S. Fiore,
P. Gauzzi,
E. Iarocci,
M. Marafini,
I. Mattei,
S. Muraro,
A. Paoloni,
V. Patera,
L. Piersanti,
F. Romano,
A. Sarti,
A. Sciubba,
E. Vitale,
C. Voena
Abstract:
Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance i…
▽ More
Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a Poly-methyl methacrylate target. Charged secondary particles, produced at 90$\degree$ with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight has been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time of flight information, and their emission region has been reconstructed backtracking from the drift chamber to the target. Moreover a position scan of the target indicates that the reconstructed emission region follows the movement of the expected Bragg peak position. Exploting the reconstruction of the emission region, an accuracy on the Bragg peak determination in the submillimeter range has been obtained. The measured differential production rate for protons produced with $E^{\rm Prod}_{\rm kin} >$ 83 MeV and emitted at 90$\degree$ with respect to the beam line is: $dN_{\rm P}/(dN_{\rm C}dΩ)(E^{\rm Prod}_{\rm kin} > 83 {\rm ~MeV}, θ=90\degree)= (2.69\pm 0.08_{\rm stat} \pm 0.12_{\rm sys})\times 10^{-4} sr^{-1}$.
△ Less
Submitted 21 March, 2012;
originally announced March 2012.
-
Underground operation of the ICARUS T600 LAr-TPC: first results
Authors:
C. Rubbia,
M. Antonello,
P. Aprili,
B. Baibussinov,
M. Baldo Ceolin,
L. Barzè,
P. Benetti,
E. Calligarich,
N. Canci,
F. Carbonara,
F. Cavanna,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
A. Dabrowska,
D. Dequal,
A. Dermenev,
R. Dolfini,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
D. Gibin
, et al. (52 additional authors not shown)
Abstract:
Open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the particle interaction Standard Model. Addressing these questions requires a new generation of massive particle detectors exploring the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 ton) example of a novel detect…
▽ More
Open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the particle interaction Standard Model. Addressing these questions requires a new generation of massive particle detectors exploring the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 ton) example of a novel detector generation able to combine the imaging capabilities of the old famous "bubble chamber" with an excellent energy measurement in huge electronic detectors. ICARUS T600 now operates at the Gran Sasso underground laboratory, studying cosmic rays, neutrino oscillation and proton decay. Physical potentialities of this novel telescope are presented through few examples of neutrino interactions reconstructed with unprecedented details. Detector design and early operation are also reported.
△ Less
Submitted 7 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.
-
FLUKA as a new high energy cosmic ray generator
Authors:
Giuseppe Battistoni,
Annarita Margiotta,
Silvia Muraro,
Maximiliano Sioli
Abstract:
FLUKA is a multipurpose Monte Carlo code, which can transport particles over a wide range of energies in user-defined geometries. Here we present a new FLUKA library, which allows the interaction and propagation of high energy cosmic rays in the Earth atmosphere and the transport of high energy muons in underground/underwater environments
FLUKA is a multipurpose Monte Carlo code, which can transport particles over a wide range of energies in user-defined geometries. Here we present a new FLUKA library, which allows the interaction and propagation of high energy cosmic rays in the Earth atmosphere and the transport of high energy muons in underground/underwater environments
△ Less
Submitted 24 February, 2010;
originally announced February 2010.
-
Secondary Cosmic Ray particles due to GCR interactions in the Earth's atmosphere
Authors:
G. Battistoni,
F. Cerutti,
A. Fassò,
A. Ferrari,
M. V. Garzelli,
M. Lantz,
S. Muraro,
L. S. Pinsky,
J. Ranft,
S. Roesler,
P. R. Sala
Abstract:
Primary GCR interact with the Earth's atmosphere originating atmospheric showers, thus giving rise to fluxes of secondary particles in the atmosphere. Electromagnetic and hadronic interactions interplay in the production of these particles, whose detection is performed by means of complementary techniques in different energy ranges and at different depths in the atmosphere, down to the Earth's s…
▽ More
Primary GCR interact with the Earth's atmosphere originating atmospheric showers, thus giving rise to fluxes of secondary particles in the atmosphere. Electromagnetic and hadronic interactions interplay in the production of these particles, whose detection is performed by means of complementary techniques in different energy ranges and at different depths in the atmosphere, down to the Earth's surface.
Monte Carlo codes are essential calculation tools which can describe the complexity of the physics of these phenomena, thus allowing the analysis of experimental data. However, these codes are affected by important uncertainties, concerning, in particular, hadronic physics at high energy. In this paper we shall report some results concerning inclusive particle fluxes and atmospheric shower properties as obtained using the FLUKA transport and interaction code. Some emphasis will also be given to the validation of the physics models of FLUKA involved in these calculations.
△ Less
Submitted 13 November, 2007;
originally announced November 2007.
-
The hadronic models for cosmic ray physics: the FLUKA code solutions
Authors:
G. Battistoni,
M. V. Garzelli,
E. Gadioli,
S. Muraro,
P. R. Sala,
A. Fassò,
A. Ferrari,
S. Roesler,
F. Cerutti,
J. Ranft,
L. S. Pinsky,
A. Empl,
M. Pelliccioni,
R. Villari
Abstract:
FLUKA is a general purpose Monte Carlo transport and interaction code used for fundamental physics and for a wide range of applications. These include Cosmic Ray Physics (muons, neutrinos, EAS, underground physics), both for basic research and applied studies in space and atmospheric flight dosimetry and radiation damage. A review of the hadronic models available in FLUKA and relevant for the de…
▽ More
FLUKA is a general purpose Monte Carlo transport and interaction code used for fundamental physics and for a wide range of applications. These include Cosmic Ray Physics (muons, neutrinos, EAS, underground physics), both for basic research and applied studies in space and atmospheric flight dosimetry and radiation damage. A review of the hadronic models available in FLUKA and relevant for the description of cosmic ray air showers is presented in this paper. Recent updates concerning these models are discussed. The FLUKA capabilities in the simulation of the formation and propagation of EM and hadronic showers in the Earth's atmosphere are shown.
△ Less
Submitted 6 December, 2006;
originally announced December 2006.