-
GraXe, graphene and xenon for neutrinoless double beta decay searches
Authors:
J. J. Gomez-Cadenas,
F. Guinea,
M. M. Fogler,
M. I. Katsnelson,
J. Martin-Albo,
F. Monrabal,
J. Muñoz-Vidal
Abstract:
We propose a new detector concept, GraXe (to be pronounced as grace), to search for neutrinoless double beta decay in Xe-136. GraXe combines a popular detection medium in rare-event searches, liquid xenon, with a new, background-free material, graphene.
In our baseline design of GraXe, a sphere made of graphene-coated titanium mesh and filled with liquid xenon (LXe) enriched in the Xe-136 isotop…
▽ More
We propose a new detector concept, GraXe (to be pronounced as grace), to search for neutrinoless double beta decay in Xe-136. GraXe combines a popular detection medium in rare-event searches, liquid xenon, with a new, background-free material, graphene.
In our baseline design of GraXe, a sphere made of graphene-coated titanium mesh and filled with liquid xenon (LXe) enriched in the Xe-136 isotope is immersed in a large volume of natural LXe instrumented with photodetectors. Liquid xenon is an excellent scintillator, reasonably transparent to its own light. Graphene is transparent over a large frequency range, and impermeable to the xenon. Event position could be deduced from the light pattern detected in the photosensors. External backgrounds would be shielded by the buffer of natural LXe, leaving the ultra-radiopure internal volume virtually free of background.
Industrial graphene can be manufactured at a competitive cost to produce the sphere. Enriching xenon in the isotope Xe-136 is easy and relatively cheap, and there is already near one ton of enriched xenon available in the world (currently being used by the EXO, KamLAND-Zen and NEXT experiments). All the cryogenic know-how is readily available from the numerous experiments using liquid xenon. An experiment using the GraXe concept appears realistic and affordable in a short time scale, and its physics potential is enormous.
△ Less
Submitted 23 February, 2012; v1 submitted 27 October, 2011;
originally announced October 2011.
-
The NEXT-100 experiment for neutrinoless double beta decay searches (Conceptual Design Report)
Authors:
NEXT Collaboration,
V. Álvarez,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera-Villanueva,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
E. Ferrer-Ribas,
A. L. Ferreira,
E. D. C. Freitas,
A. Gil
, et al. (58 additional authors not shown)
Abstract:
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution…
▽ More
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution (<1%), very low background con- tamination (1E-4 counts/(keV \bullet kg \bullet y)) and large target mass. In addition, it needs to be operational as soon as possible. The design described here optimizes energy resolution thanks to the use of proportional electroluminescent amplification (EL); it is compact, as the Xe gas is under high pressure; and it allows the measurement of the topological signature of the event to further reduce the background contamination. The SOFT design uses different sensors for tracking and calorimetry. We propose the use of SiPMs (MPPCs) coated with a suitable wavelength shifter for the tracking, and the use of radiopure photomultipliers for the measurement of the energy and the primary scintillation needed to estimate the t0. This design provides the best possible energy resolution compared with other NEXT designs based on avalanche gain devices. The baseline design is an Asymmetric Neutrino Gas EL apparatus (ANGEL), which was already outlined in the NEXT LOI. ANGEL is conceived to be easy to fabricate. It requires very little R&D and most of the proposed solutions have already been tested in the NEXT-1 prototypes. Therefore, the detector can be ready by 2013. In this Conceptual Design Report (CDR) we discuss first the physics case, present a full design of the detector, describe the NEXT-1 EL prototypes and their initial results, and outline a project to build a detector with 100 kg of enriched xenon to be installed in the Canfranc Underground Laboratory in 2013.
△ Less
Submitted 18 June, 2011;
originally announced June 2011.
-
Sense and sensitivity of double beta decay experiments
Authors:
J. J. Gomez-Cadenas,
J. Martin-Albo,
M. Sorel,
P. Ferrario,
F. Monrabal,
J. Munoz-Vidal,
P. Novella,
A. Poves
Abstract:
The search for neutrinoless double beta decay is a very active field in which the number of proposals for next-generation experiments has proliferated. In this paper we attempt to address both the sense and the sensitivity of such proposals. Sensitivity comes first, by means of proposing a simple and unambiguous statistical recipe to derive the sensitivity to a putative Majorana neutrino mass, m_b…
▽ More
The search for neutrinoless double beta decay is a very active field in which the number of proposals for next-generation experiments has proliferated. In this paper we attempt to address both the sense and the sensitivity of such proposals. Sensitivity comes first, by means of proposing a simple and unambiguous statistical recipe to derive the sensitivity to a putative Majorana neutrino mass, m_bb. In order to make sense of how the different experimental approaches compare, we apply this recipe to a selection of proposals, comparing the resulting sensitivities. We also propose a "physics-motivated range" (PMR) of the nuclear matrix elements as a unifying criterium between the different nuclear models. The expected performance of the proposals is parametrized in terms of only four numbers: energy resolution, background rate (per unit time, isotope mass and energy), detection efficiency, and bb isotope mass. For each proposal, both a reference and an optimistic scenario for the experimental performance are studied. In the reference scenario we find that all the proposals will be able to partially explore the degenerate spectrum, without fully covering it, although four of them (KamLAND-Zen, CUORE, NEXT and EXO) will approach the 50 meV boundary. In the optimistic scenario, we find that CUORE and the xenon-based proposals (KamLAND-Zen, EXO and NEXT) will explore a significant fraction of the inverse hierarchy, with NEXT covering it almost fully. For the long term future, we argue that Xe-based experiments may provide the best case for a 1-ton scale experiment, given the potentially very low backgrounds achievable and the expected scalability to large isotope masses.
△ Less
Submitted 30 March, 2011; v1 submitted 25 October, 2010;
originally announced October 2010.
-
NEXT, a HPGXe TPC for neutrinoless double beta decay searches
Authors:
The NEXT Collaboration,
F. Granena,
T. Lux,
F. Nova,
J. Rico,
F. Sanchez,
D. R. Nygren,
J. A. S. Barata,
F. I. G. M. Borges,
C. A. N. Conde,
T. H. V. T. Dias,
L. M. P. Fernandes,
E. D. C. Freitas,
J. A. M. Lopes,
C. M. B. Monteiro,
J. M. F. dos Santos,
F. P. Santos,
L. M. N. Tavora,
J. F. C. A. Veloso,
E. Calvo,
I. Gil-Botella,
P. Novella,
C. Palomares,
A. Verdugo,
I. Giomataris
, et al. (39 additional authors not shown)
Abstract:
We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological s…
▽ More
We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological signature, the design discussed in this Letter Of Intent promises to be competitive and possibly out-perform existing proposals for next-generation neutrinoless double-beta decay experiments. We discuss the detection principles, design specifications, physics potential and R&D plans to construct a detector with 100 kg fiducial mass in the double-beta decay emitting isotope Xe(136), to be installed in the Canfranc Underground Laboratory.
△ Less
Submitted 22 July, 2009;
originally announced July 2009.