-
First Measurement of the $ν_e$ and $ν_μ$ Interaction Cross Sections at the LHC with FASER's Emulsion Detector
Authors:
FASER Collaboration,
Roshan Mammen Abraham,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Angela Burger,
Franck Cadoux,
Roberto Cardella,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Debieux,
Monica D'Onofrio,
Ansh Desai,
Sergey Dmitrievsky,
Sinead Eley,
Yannick Favre,
Deion Fellers
, et al. (80 additional authors not shown)
Abstract:
This paper presents the first results of the study of high-energy electron and muon neutrino charged-current interactions in the FASER$ν$ emulsion/tungsten detector of the FASER experiment at the LHC. A subset of the FASER$ν$ volume, which corresponds to a target mass of 128.6~kg, was exposed to neutrinos from the LHC $pp$ collisions with a centre-of-mass energy of 13.6~TeV and an integrated lumin…
▽ More
This paper presents the first results of the study of high-energy electron and muon neutrino charged-current interactions in the FASER$ν$ emulsion/tungsten detector of the FASER experiment at the LHC. A subset of the FASER$ν$ volume, which corresponds to a target mass of 128.6~kg, was exposed to neutrinos from the LHC $pp$ collisions with a centre-of-mass energy of 13.6~TeV and an integrated luminosity of 9.5 fb$^{-1}$. Applying stringent selections requiring electrons with reconstructed energy above 200~GeV, four electron neutrino interaction candidate events are observed with an expected background of $0.025^{+0.015}_{-0.010}$, leading to a statistical significance of 5.2$σ$. This is the first direct observation of electron neutrino interactions at a particle collider. Eight muon neutrino interaction candidate events are also detected, with an expected background of $0.22^{+0.09}_{-0.07}$, leading to a statistical significance of 5.7$σ$. The signal events include neutrinos with energies in the TeV range, the highest-energy electron and muon neutrinos ever detected from an artificial source. The energy-independent part of the interaction cross section per nucleon is measured over an energy range of 560--1740 GeV (520--1760 GeV) for $ν_e$ ($ν_μ$) to be $(1.2_{-0.7}^{+0.8}) \times 10^{-38}~\mathrm{cm}^{2}\,\mathrm{GeV}^{-1}$ ($(0.5\pm0.2) \times 10^{-38}~\mathrm{cm}^{2}\,\mathrm{GeV}^{-1}$), consistent with Standard Model predictions. These are the first measurements of neutrino interaction cross sections in those energy ranges.
△ Less
Submitted 19 March, 2024;
originally announced March 2024.
-
Neutrino Rate Predictions for FASER
Authors:
FASER Collaboration,
Roshan Mammen Abraham,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Angela Burger,
Franck Cadoux,
Roberto Cardella,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Débieux,
Monica D'Onofrio,
Ansh Desai,
Sergey Dmitrievsky,
Sinead Eley,
Yannick Favre,
Deion Fellers
, et al. (75 additional authors not shown)
Abstract:
The Forward Search Experiment (FASER) at CERN's Large Hadron Collider (LHC) has recently directly detected the first collider neutrinos. Neutrinos play an important role in all FASER analyses, either as signal or background, and it is therefore essential to understand the neutrino event rates. In this study, we update previous simulations and present prescriptions for theoretical predictions of ne…
▽ More
The Forward Search Experiment (FASER) at CERN's Large Hadron Collider (LHC) has recently directly detected the first collider neutrinos. Neutrinos play an important role in all FASER analyses, either as signal or background, and it is therefore essential to understand the neutrino event rates. In this study, we update previous simulations and present prescriptions for theoretical predictions of neutrino fluxes and cross sections, together with their associated uncertainties. With these results, we discuss the potential for possible measurements that could be carried out in the coming years with the FASER neutrino data to be collected in LHC Run 3 and Run 4.
△ Less
Submitted 13 June, 2024; v1 submitted 20 February, 2024;
originally announced February 2024.
-
Test-beam Performance Results of the FASTPIX Sub-Nanosecond CMOS Pixel Sensor Demonstrator
Authors:
Justus Braach,
Eric Buschmann,
Dominik Dannheim,
Katharina Dort,
Thanushan Kugathasan,
Magdalena Munker,
Walter Snoeys,
Peter Švihra,
Mateus Vicente
Abstract:
Within the ATTRACT FASTPIX project, a monolithic pixel sensor demonstrator chip has been developed in a modified 180 nm CMOS imaging process technology, targeting sub-nanosecond timing precision for single ionising particles. It features a small collection electrode design on a 25 micrometers-thick epitaxial layer and contains 32 mini matrices of 68 hexagonal pixels each, with pixel pitches rangin…
▽ More
Within the ATTRACT FASTPIX project, a monolithic pixel sensor demonstrator chip has been developed in a modified 180 nm CMOS imaging process technology, targeting sub-nanosecond timing precision for single ionising particles. It features a small collection electrode design on a 25 micrometers-thick epitaxial layer and contains 32 mini matrices of 68 hexagonal pixels each, with pixel pitches ranging from 8.66 to 20 micrometers. Four pixels are transmitting an analog output signal and 64 are transmitting binary hit information. Various design variations are explored, aiming at accelerating the charge collection and making the timing of the charge collection more uniform over the pixel area. Signal treatment of the analog waveforms, as well as reconstruction of digital position, time and charge information, is carried out off-chip. This contribution introduces the design of the sensor and readout system and presents performance results for various pixel designs achieved in recent test beam measurements with external tracking and timing reference detectors. A time resolution below 150 ps is obtained at full efficiency for all pixel pitches.
△ Less
Submitted 25 September, 2023; v1 submitted 9 June, 2023;
originally announced June 2023.
-
First Direct Observation of Collider Neutrinos with FASER at the LHC
Authors:
FASER Collaboration,
Henso Abreu,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Blesgen,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Ansh Desai,
Sergey Dmitrievsky,
Monica D'Onofrio,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Carlo Alberto Fenoglio,
Didier Ferrere
, et al. (63 additional authors not shown)
Abstract:
We report the first direct observation of neutrino interactions at a particle collider experiment. Neutrino candidate events are identified in a 13.6 TeV center-of-mass energy $pp$ collision data set of 35.4 fb${}^{-1}$ using the active electronic components of the FASER detector at the Large Hadron Collider. The candidates are required to have a track propagating through the entire length of the…
▽ More
We report the first direct observation of neutrino interactions at a particle collider experiment. Neutrino candidate events are identified in a 13.6 TeV center-of-mass energy $pp$ collision data set of 35.4 fb${}^{-1}$ using the active electronic components of the FASER detector at the Large Hadron Collider. The candidates are required to have a track propagating through the entire length of the FASER detector and be consistent with a muon neutrino charged-current interaction. We infer $153^{+12}_{-13}$ neutrino interactions with a significance of 16 standard deviations above the background-only hypothesis. These events are consistent with the characteristics expected from neutrino interactions in terms of secondary particle production and spatial distribution, and they imply the observation of both neutrinos and anti-neutrinos with an incident neutrino energy of significantly above 200 GeV.
△ Less
Submitted 21 August, 2023; v1 submitted 24 March, 2023;
originally announced March 2023.
-
Entropy bound for time reversal markers
Authors:
Gabriel Knotz,
Till M. Muenker,
Timo Betz,
Matthias Krüger
Abstract:
We derive a bound for entropy production in terms of the mean of normalizable path-antisymmetric observables. The optimal observable for this bound is shown to be the signum of entropy production, which is often easier determined or estimated than entropy production itself. It can be preserved under coarse graining by use of a simple path grou** algorithm. We demonstrate this relation and its pr…
▽ More
We derive a bound for entropy production in terms of the mean of normalizable path-antisymmetric observables. The optimal observable for this bound is shown to be the signum of entropy production, which is often easier determined or estimated than entropy production itself. It can be preserved under coarse graining by use of a simple path grou** algorithm. We demonstrate this relation and its properties using a driven network on a ring, for which the bound saturates for short times for any driving strength. This work can open a way to systematic coarse graining of entropy production.
△ Less
Submitted 13 November, 2023; v1 submitted 15 February, 2023;
originally announced February 2023.
-
20 ps Time Resolution with a Fully-Efficient Monolithic Silicon Pixel Detector without Internal Gain Layer
Authors:
S. Zambito,
M. Milanesio,
T. Moretti,
L. Paolozzi,
M. Munker,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
M. Elviretti,
H. Rücker,
A. Trusch,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (3 additional authors not shown)
Abstract:
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel…
▽ More
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel matrix show that the sensor has a 130 V wide bias-voltage operation plateau at which the efficiency is 99.8%. Although this prototype does not include an internal gain layer, the design optimised for timing of the sensor and the front-end electronics provides a time resolutions of 20 ps.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate
Authors:
H. Pernegger,
P. Allport,
D. V. Berlea,
A. Birman,
D. Bortoletto,
C. Buttar,
E. Charbon,
F. Dachs,
V. Dao,
H. Denizli,
D. Dobrijevic,
M. Dyndal,
A. Fenigstein,
L. Flores Sanz de Acedo,
P. Freeman,
A. Gabrielli,
M. Gazi,
L. Gonella,
V. Gonzalez,
G. Gustavino,
A. Haim,
T. Kugathasan,
M. LeBlanc,
M. Munker,
K. Y. Oyulmaz
, et al. (14 additional authors not shown)
Abstract:
Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The "MALTA-Czochralski (MALTA-Cz)" full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granulari…
▽ More
Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The "MALTA-Czochralski (MALTA-Cz)" full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granularity, high hit-rate capability, fast response time and superior radiation tolerance. The small pixel size ($36.4\times 36.4$~$μ$m$^2$) provides high spatial resolution. Its asynchronous readout architecture is designed for high hit-rates and fast time response in triggered and trigger-less detector applications. The readout architecture is designed to stream all hit data to the multi-channel output which allows an off-sensor trigger formation and the use of hit-time information for event tagging.
The sensor manufacturing has been optimised through process adaptation and special implant designs to allow the manufacturing of small electrode DMAPS on thick high-resistivity p-type Czochralski substrate. The special processing ensures excellent charge collection and charge particle detection efficiency even after a high level of radiation. Furthermore the special implant design and use of a Czochralski substrate improves the sensor's time resolution. This paper presents a summary of sensor design optimisation through process and implant choices and TCAD simulation to model the signal response. Beam and laboratory test results on unirradiated and irradiated sensors have shown excellent detection efficiency after a dose of $2\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$. The time resolution of the sensor is measured to be $σ=2$~ns.
△ Less
Submitted 13 September, 2023; v1 submitted 10 January, 2023;
originally announced January 2023.
-
Digital Pixel Test Structures implemented in a 65 nm CMOS process
Authors:
Gianluca Aglieri Rinella,
Anton Andronic,
Matias Antonelli,
Mauro Aresti,
Roberto Baccomi,
Pascal Becht,
Stefania Beole,
Justus Braach,
Matthew Daniel Buckland,
Eric Buschmann,
Paolo Camerini,
Francesca Carnesecchi,
Leonardo Cecconi,
Edoardo Charbon,
Giacomo Contin,
Dominik Dannheim,
Joao de Melo,
Wen**g Deng,
Antonello di Mauro,
Jan Hasenbichler,
Hartmut Hillemanns,
Geun Hee Hong,
Artem Isakov,
Antoine Junique,
Alex Kluge
, et al. (27 additional authors not shown)
Abstract:
The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20 to 40 um and bent to form truly cylindrical half barrels. Among the…
▽ More
The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20 to 40 um and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article.
The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at +20 C and a detection efficiency of 99% for a DPTS irradiated with a dose of $10^{15}$ 1 MeV n$_{\mathrm{eq}}/$cm$^2$. Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.
△ Less
Submitted 10 July, 2023; v1 submitted 16 December, 2022;
originally announced December 2022.
-
Testbeam Results of the Picosecond Avalanche Detector Proof-Of-Concept Prototype
Authors:
G. Iacobucci,
S. Zambito,
M. Milanesio,
T. Moretti,
J. Saidi,
L. Paolozzi,
M. Munker,
R. Cardella,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina
, et al. (2 additional authors not shown)
Abstract:
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector…
▽ More
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector provides full efficiency and average time resolution of 30, 25 and 17 ps in the overall pixel area for a power consumption of 0.4, 0.9 and 2.7 W/cm^2, respectively. In this first prototype the time resolution depends significantly on the distance from the center of the pixel, varying at the highest power consumption measured between 13 ps at the center of the pixel and 25 ps in the inter-pixel region.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
The FASER Detector
Authors:
FASER Collaboration,
Henso Abreu,
Elham Amin Mansour,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Olivier Crespo-Lopez,
Stephane Debieux,
Monica D'Onofrio,
Liam Dougherty,
Candan Dozen,
Abdallah Ezzat,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere
, et al. (72 additional authors not shown)
Abstract:
FASER, the ForwArd Search ExpeRiment, is an experiment dedicated to searching for light, extremely weakly-interacting particles at CERN's Large Hadron Collider (LHC). Such particles may be produced in the very forward direction of the LHC's high-energy collisions and then decay to visible particles inside the FASER detector, which is placed 480 m downstream of the ATLAS interaction point, aligned…
▽ More
FASER, the ForwArd Search ExpeRiment, is an experiment dedicated to searching for light, extremely weakly-interacting particles at CERN's Large Hadron Collider (LHC). Such particles may be produced in the very forward direction of the LHC's high-energy collisions and then decay to visible particles inside the FASER detector, which is placed 480 m downstream of the ATLAS interaction point, aligned with the beam collisions axis. FASER also includes a sub-detector, FASER$ν$, designed to detect neutrinos produced in the LHC collisions and to study their properties. In this paper, each component of the FASER detector is described in detail, as well as the installation of the experiment system and its commissioning using cosmic-rays collected in September 2021 and during the LHC pilot beam test carried out in October 2021. FASER will start taking LHC collision data in 2022, and will run throughout LHC Run 3.
△ Less
Submitted 23 July, 2022;
originally announced July 2022.
-
Roadmap for Optical Tweezers
Authors:
Giovanni Volpe,
Onofrio M. Maragò,
Halina Rubinzstein-Dunlop,
Giuseppe Pesce,
Alexander B. Stilgoe,
Giorgio Volpe,
Georgiy Tkachenko,
Viet Giang Truong,
Síle Nic Chormaic,
Fatemeh Kalantarifard,
Parviz Elahi,
Mikael Käll,
Agnese Callegari,
Manuel I. Marqués,
Antonio A. R. Neves,
Wendel L. Moreira,
Adriana Fontes,
Carlos L. Cesar,
Rosalba Saija,
Abir Saidi,
Paul Beck,
Jörg S. Eismann,
Peter Banzer,
Thales F. D. Fernandes,
Francesco Pedaci
, et al. (58 additional authors not shown)
Abstract:
Optical tweezers are tools made of light that enable contactless pushing, trap**, and manipulation of objects ranging from atoms to space light sails. Since the pioneering work by Arthur Ashkin in the 1970s, optical tweezers have evolved into sophisticated instruments and have been employed in a broad range of applications in life sciences, physics, and engineering. These include accurate force…
▽ More
Optical tweezers are tools made of light that enable contactless pushing, trap**, and manipulation of objects ranging from atoms to space light sails. Since the pioneering work by Arthur Ashkin in the 1970s, optical tweezers have evolved into sophisticated instruments and have been employed in a broad range of applications in life sciences, physics, and engineering. These include accurate force and torque measurement at the femtonewton level, microrheology of complex fluids, single micro- and nanoparticle spectroscopy, single-cell analysis, and statistical-physics experiments. This roadmap provides insights into current investigations involving optical forces and optical tweezers from their theoretical foundations to designs and setups. It also offers perspectives for applications to a wide range of research fields, from biophysics to space exploration.
△ Less
Submitted 28 June, 2022;
originally announced June 2022.
-
Picosecond Avalanche Detector -- working principle and gain measurement with a proof-of-concept prototype
Authors:
L. Paolozzi,
M. Munker,
R. Cardella,
M. Milanesio,
Y. Gurimskaya,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
R. Kotitsa,
C. Magliocca,
T. Moretti,
M. Nessi,
A. Pizarro Medina,
J. Sabater Iglesias,
J. Saidi,
M. Vicente Barreto Pinto
, et al. (2 additional authors not shown)
Abstract:
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The si…
▽ More
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The signal is then induced by the secondary charges moving inside a thicker drift region. A proof-of-concept monolithic prototype, consisting of a matrix of hexagonal pixels with 100 $μ$m pitch, has been produced using the 130 nm SiGe BiCMOS process by IHP microelectronics. Measurements on probe station and with a $^{55}$Fe X-ray source show that the prototype is functional and displays avalanche gain up to a maximum electron gain of 23. A study of the avalanche characteristics, corroborated by TCAD simulations, indicates that space-charge effects due to the large primary charge produced by the conversion of X-rays from the $^{55}$Fe source limits the effective gain.
△ Less
Submitted 25 September, 2022; v1 submitted 16 June, 2022;
originally announced June 2022.
-
Comparison of different sensor thicknesses and substrate materials for the monolithic small collection-electrode technology demonstrator CLICTD
Authors:
Katharina Dort,
Rafael Ballabriga,
Justus Braach,
Eric Buschmann,
Michael Campbell,
Dominik Dannheim,
Lennart Huth,
Iraklis Kremastiotis,
Jens Kröger,
Lucie Linssen,
Magdalena Munker,
Walter Snoeys,
Simon Spannagel,
Peter Švihra,
Tomas Vanat
Abstract:
Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high-resistivity epitaxial layers. In this paper, the active sensor depth is investigated in the monolithic small collection-electrode technology demonstrator CLICTD. Charged particle beams ar…
▽ More
Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high-resistivity epitaxial layers. In this paper, the active sensor depth is investigated in the monolithic small collection-electrode technology demonstrator CLICTD. Charged particle beams are used to study the charge-collection properties and the performance of devices with different thicknesses both for perpendicular and inclined particle incidence. In CMOS sensors with a high-resistivity Czochralski substrate, the depth of the sensitive volume is found to increase by a factor two in comparison with standard epitaxial material and leads to significant improvements in the hit-detection efficiency and the spatial and time resolution.
△ Less
Submitted 30 August, 2022; v1 submitted 22 April, 2022;
originally announced April 2022.
-
Transient Monte Carlo Simulations for the Optimisation and Characterisation of Monolithic Silicon Sensors
Authors:
Rafael Ballabriga,
Justus Braach,
Eric Buschmann,
Michael Campbell,
Dominik Dannheim,
Katharina Dort,
Lennart Huth,
Iraklis Kremastiotis,
Jens Kröger,
Lucie Linssen,
Magdalena Munker,
Paul Schütze,
Walter Snoeys,
Simon Spannagel,
Tomas Vanat
Abstract:
An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite element simulations with a transient Monte Carlo approach provides simultaneous access to precise sensor modelling and high statistics. The high simulation statistics enable the inclusion of Landau fluctuations and produc…
▽ More
An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite element simulations with a transient Monte Carlo approach provides simultaneous access to precise sensor modelling and high statistics. The high simulation statistics enable the inclusion of Landau fluctuations and production of secondary particles, which offers a realistic simulation scenario. The transient simulation approach is an important tool to achieve an accurate time-resolved description of the sensor, which is crucial in the face of novel detector prototypes with increasingly precise timing capabilities. The simulated time resolution as a function of operating parameters as well as the full transient pulse can be monitored and assessed, which offers a new perspective on the optimisation and characterisation of silicon sensors.
In this paper, a combination of electrostatic finite-element simulations using 3D TCAD and transient Monte Carlo simulations with the Allpix Squared framework are presented for a monolithic CMOS pixel sensor with a small collection diode, that is characterised by a highly inhomogeneous, complex electric field. The results are compared to transient 3D TCAD simulations that offer a precise simulation of the transient behaviour but long computation times. Additionally, the simulations are benchmarked against test-beam data and good agreement is found for the performance parameters over a wide range of different operation conditions.
△ Less
Submitted 9 February, 2022; v1 submitted 7 February, 2022;
originally announced February 2022.
-
Efficiency and time resolution of monolithic silicon pixel detectors in SiGe BiCMOS technology
Authors:
G. Iacobucci,
L. Paolozzi,
P. Valerio,
T. Moretti,
F. Cadoux,
R. Cardarelli,
R. Cardella,
S. Débieux,
Y. Favre,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
F. Martinelli,
M. Milanesio,
M. Münker,
M. Nessi,
A. Picardi,
J. Saidi,
H. Rücker,
M. Vicente Barreto Pinto,
S. Zambito
Abstract:
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% w…
▽ More
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% was measured together with a time resolution of $(36.4 \pm 0.8)$ps at the highest preamplifier bias current working point of 150 $μ$A and at a sensor bias voltage of 160 V. The ASIC was also characterized at lower bias voltage and preamplifier current.
△ Less
Submitted 21 January, 2022; v1 submitted 16 December, 2021;
originally announced December 2021.
-
The tracking detector of the FASER experiment
Authors:
FASER Collaboration,
Henso Abreu,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Olivier Crespo-Lopez,
Sergey Dmitrievsky,
Monica D'Onofrio,
Candan Dozen,
Abdallah Ezzat,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere,
Stephen Gibson,
Sergio Gonzalez-Sevilla
, et al. (55 additional authors not shown)
Abstract:
FASER is a new experiment designed to search for new light weakly-interacting long-lived particles (LLPs) and study high-energy neutrino interactions in the very forward region of the LHC collisions at CERN. The experimental apparatus is situated 480 m downstream of the ATLAS interaction-point aligned with the beam collision axis. The FASER detector includes four identical tracker stations constru…
▽ More
FASER is a new experiment designed to search for new light weakly-interacting long-lived particles (LLPs) and study high-energy neutrino interactions in the very forward region of the LHC collisions at CERN. The experimental apparatus is situated 480 m downstream of the ATLAS interaction-point aligned with the beam collision axis. The FASER detector includes four identical tracker stations constructed from silicon microstrip detectors. Three of the tracker stations form a tracking spectrometer, and enable FASER to detect the decay products of LLPs decaying inside the apparatus, whereas the fourth station is used for the neutrino analysis. The spectrometer has been installed in the LHC complex since March 2021, while the fourth station is not yet installed. FASER will start physics data taking when the LHC resumes operation in early 2022. This paper describes the design, construction and testing of the tracking spectrometer, including the associated components such as the mechanics, readout electronics, power supplies and cooling system.
△ Less
Submitted 31 May, 2022; v1 submitted 2 December, 2021;
originally announced December 2021.
-
The trigger and data acquisition system of the FASER experiment
Authors:
FASER Collaboration,
Henso Abreu,
Elham Amin Mansour,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Debieux,
Sergey Dmitrievsky,
Monica D'Onofrio,
Candan Dozen,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere,
Enrico Gamberini,
Edward Karl Galantay
, et al. (59 additional authors not shown)
Abstract:
The FASER experiment is a new small and inexpensive experiment that is placed 480 meters downstream of the ATLAS experiment at the CERN LHC. FASER is designed to capture decays of new long-lived particles, produced outside of the ATLAS detector acceptance. These rare particles can decay in the FASER detector together with about 500-1000 Hz of other particles originating from the ATLAS interaction…
▽ More
The FASER experiment is a new small and inexpensive experiment that is placed 480 meters downstream of the ATLAS experiment at the CERN LHC. FASER is designed to capture decays of new long-lived particles, produced outside of the ATLAS detector acceptance. These rare particles can decay in the FASER detector together with about 500-1000 Hz of other particles originating from the ATLAS interaction point. A very high efficiency trigger and data acquisition system is required to ensure that the physics events of interest will be recorded. This paper describes the trigger and data acquisition system of the FASER experiment and presents performance results of the system acquired during initial commissioning.
△ Less
Submitted 10 January, 2022; v1 submitted 28 October, 2021;
originally announced October 2021.
-
Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement
Authors:
R. Ballabriga,
E. Buschmann,
M. Campbell,
D. Dannheim,
K. Dort,
N. Egidos,
L. Huth,
I. Kremastiotis,
J. Kröger,
L. Linssen,
X. Llopart,
M. Munker,
A. Nürnberg,
W. Snoeys,
S. Spannagel,
T. Vanat,
M. Vicente,
M. Williams
Abstract:
The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the trackin…
▽ More
The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the tracking detector studies for the Compact Linear Collider (CLIC). Its design characteristics are of broad interest beyond CLIC, for HL-LHC tracking detector upgrades. It is produced in two different pixel flavours: one with a continuous deep n-type implant, and one with a segmented n-type implant to ensure fast charge collection. The pixel matrix consists of $16\times128$ detection channels measuring $300 \times 30$ microns. Each detection channel is segmented into eight sub-pixels to reduce the amount of digital circuity while maintaining a small collection electrode pitch. This paper presents the characterisation results of the CLICTD sendor in a particle beam. The different pixel flavours are compared in detail by using the simultaneous time-over-threshold and time-of-arrival measurement functionalities. Most notably, a time resolution down to $(5.8 \pm 0.1)$ ns and a spatial resolution down to $(4.6 \pm 0.2)$ microns are measured. The hit detection efficiency is found to be well above 99.7% for thresholds of the order of several hundred electrons.
△ Less
Submitted 8 February, 2021;
originally announced February 2021.
-
Corryvreckan: A Modular 4D Track Reconstruction and Analysis Software for Test Beam Data
Authors:
Dominik Dannheim,
Katharina Dort,
Lennart Huth,
Daniel Hynds,
Iraklis Kremastiotis,
Jens Kröger,
Magdalena Munker,
Florian Pitters,
Paul Schütze,
Simon Spannagel,
Tomas Vanat,
Morag Williams
Abstract:
Corryvreckan is a versatile, highly configurable software with a modular structure designed to reconstruct and analyse test beam and laboratory data. It caters to the needs of the test beam community by providing a flexible offline event building facility to combine detectors with different read-out schemes, with or without trigger information, and includes the possibility to correlate data from m…
▽ More
Corryvreckan is a versatile, highly configurable software with a modular structure designed to reconstruct and analyse test beam and laboratory data. It caters to the needs of the test beam community by providing a flexible offline event building facility to combine detectors with different read-out schemes, with or without trigger information, and includes the possibility to correlate data from multiple devices based on timestamps.
Hit timing information, available with high precision from an increasing number of detectors, can be used in clustering and tracking to reduce combinatorics. Several algorithms, including an implementation of Millepede-II, are provided for offline alignment. A graphical user interface enables direct monitoring of the reconstruction progress and can be employed for quasi-online monitoring during data taking.
This work introduces the Corryvreckan framework architecture and user interface, and provides a detailed overview of the event building algorithm. The reconstruction and analysis capabilities are demonstrated with data recorded at the DESY II Test Beam Facility using the EUDAQ2 data acquisition framework with an EUDET-type beam telescope, a Timepix3 timing reference, a fine-pitch planar silicon sensor with CLICpix2 readout and the AIDA Trigger Logic Unit. The individual steps of the reconstruction chain are presented in detail.
△ Less
Submitted 13 January, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
CLICTD: A monolithic HR-CMOS sensor chip for the CLIC silicon tracker
Authors:
I. Kremastiotis,
R. Ballabriga,
K. Dort,
N. Egidos,
M. Munker
Abstract:
The CLIC Tracker Detector (CLICTD) is a monolithic pixelated sensor chip produced in a $180$ nm imaging CMOS process built on a high-resistivity epitaxial layer. The chip, designed in the context of the CLIC tracking detector study, comprises a matrix of ${16\times128}$ elongated pixels, each measuring ${300\times30}$ $μ$m$^2$. To ensure prompt charge collection, every elongated pixel is segmented…
▽ More
The CLIC Tracker Detector (CLICTD) is a monolithic pixelated sensor chip produced in a $180$ nm imaging CMOS process built on a high-resistivity epitaxial layer. The chip, designed in the context of the CLIC tracking detector study, comprises a matrix of ${16\times128}$ elongated pixels, each measuring ${300\times30}$ $μ$m$^2$. To ensure prompt charge collection, every elongated pixel is segmented in eight sub-pixels, each containing a collection diode and a separate analog front-end. A simultaneous $8$-bit time measurement with $10$ ns time bins and $5$-bit energy measurement with programmable range is performed in the on-pixel digital logic. The main design aspects as well as the first results from laboratory measurements with the CLICTD chip are presented.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Combining TCAD and Monte Carlo Methods to Simulate CMOS Pixel Sensors with a Small Collection Electrode using the Allpix Squared Framework
Authors:
Dominik Dannheim,
Katharina Dort,
Daniel Hynds,
Magdalena Munker,
Andreas Nürnberg,
Walter Snoeys,
Simon Spannagel
Abstract:
Combining electrostatic field simulations with Monte Carlo methods enables realistic modeling of the detector response for novel monolithic silicon detectors with strongly non-linear electric fields. Both the precise field description and the inclusion of Landau fluctuations and production of secondary particles in the sensor are crucial ingredients for the understanding and reproduction of detect…
▽ More
Combining electrostatic field simulations with Monte Carlo methods enables realistic modeling of the detector response for novel monolithic silicon detectors with strongly non-linear electric fields. Both the precise field description and the inclusion of Landau fluctuations and production of secondary particles in the sensor are crucial ingredients for the understanding and reproduction of detector characteristics.
In this paper, a CMOS pixel sensor with small collection electrode design, implemented in a high-resistivity epitaxial layer, is simulated by integrating a detailed electric field model from finite element TCAD into a Monte Carlo based simulation with the Allpix$^2$ framework. The simulation results are compared to data recorded in test-beam measurements and very good agreement is found for various quantities such as cluster size, spatial resolution and efficiency. Furthermore, the observables are studied as a function of the intra-pixel incidence position to enable a detailed comparison with the detector behavior observed in data.
The validation of such simulations is fundamental for modeling the detector response and for predicting the performance of future prototype designs. Moreover, visualization plots extracted from the charge carrier drift model of the framework can aid in understanding the charge propagation behavior in different regions of the sensor.
△ Less
Submitted 28 February, 2020;
originally announced February 2020.
-
Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC
Authors:
M. Dyndal,
V. Dao,
P. Allport,
I. Asensi Tortajada,
M. Barbero,
S. Bhat,
D. Bortoletto,
I. Berdalovic,
C. Bespin,
C. Buttar,
I. Caicedo,
R. Cardella,
F. Dachs,
Y. Degerli,
H. Denizli,
L. Flores Sanz de Acedo,
P. Freeman,
L. Gonella,
A. Habib,
T. Hemperek,
T. Hirono,
B. Hiti,
T. Kugathasan,
I. Mandić,
D. Maneuski
, et al. (19 additional authors not shown)
Abstract:
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silico…
▽ More
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silicon. The design targets a radiation hardness of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$, compatible with the outermost layer of the ATLAS ITK Pixel detector. This paper presents the results from characterization in particle beam tests of the Mini-MALTA prototype that implements a mask change or an additional implant to address the inefficiencies on the pixel edges. Results show full efficiency after a dose of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$.
△ Less
Submitted 14 December, 2019; v1 submitted 26 September, 2019;
originally announced September 2019.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
Performance evaluation of thin active-edge planar sensors for the CLIC vertex detector
Authors:
Andreas Nürnberg,
Niloufar Alipour Tehrani,
Mathieu Benoit,
Dominik Dannheim,
Adrian Fiergolski,
Daniel Hynds,
Wolfgang Klempt,
Anna Macchiolo,
Magdalena Munker
Abstract:
Thin planar silicon sensors with a pitch of 55um, active edge and various guard ring layouts are investigated, using two-dimensional finite-element T-CAD simulations. The simulation results have been compared to experimental data, and an overall good agreement is observed. It is demonstrated that 50um thin planar silicon sensors with active edge with floating guard ring or without guard ring can b…
▽ More
Thin planar silicon sensors with a pitch of 55um, active edge and various guard ring layouts are investigated, using two-dimensional finite-element T-CAD simulations. The simulation results have been compared to experimental data, and an overall good agreement is observed. It is demonstrated that 50um thin planar silicon sensors with active edge with floating guard ring or without guard ring can be operated fully efficiently up to the physical edge of the sensor. The simulation findings are used to identify suitable sensor designs for application in the high-precision vertex detector of the future CLIC linear $e^+e^-$ collider.
△ Less
Submitted 22 April, 2019;
originally announced April 2019.
-
Simulations of CMOS pixel sensors with a small collection electrode, improved for a faster charge collection and increased radiation tolerance
Authors:
Magdalena Munker,
Mathieu Benoit,
Dominik Dannheim,
Amos Fenigstein,
Thanushan Kugathasan,
Tomer Leitner,
Heinz Pernegger,
Petra Riedler,
Walter Snoeys
Abstract:
CMOS pixel sensors with a small collection electrode combine the advantages of a small sensor capacitance with the advantages of a fully monolithic design. The small sensor capacitance results in a large ratio of signal-to-noise and a low analogue power consumption, while the monolithic design reduces the material budget, cost and production effort. However, the low electric field in the pixel cor…
▽ More
CMOS pixel sensors with a small collection electrode combine the advantages of a small sensor capacitance with the advantages of a fully monolithic design. The small sensor capacitance results in a large ratio of signal-to-noise and a low analogue power consumption, while the monolithic design reduces the material budget, cost and production effort. However, the low electric field in the pixel corners of such sensors results in an increased charge collection time, that makes a fully efficient operation after irradiation and a timing resolution in the order of nanoseconds challenging for pixel sizes larger than approximately forty micrometers. This paper presents the development of concepts of CMOS sensors with a small collection electrode to overcome these limitations, using three-dimensional Technology Computer Aided Design simulations. The studied design uses a 0.18 micrometer process implemented on a high-resistivity epitaxial layer.
△ Less
Submitted 7 May, 2019; v1 submitted 25 March, 2019;
originally announced March 2019.
-
Tracking performance and simulation of capacitively coupled pixel detectors for the CLIC vertex detector
Authors:
N. Alipour~Tehrani,
M. Benoit,
M. Buckland,
D. Dannheim,
A. Fiergolski,
S. Green,
D. Hynds,
I. Kremastiotis,
S. Kulis,
M. Munker,
A. Nürnberg,
I. Peric,
M. Petric,
E. Sicking,
M. Vicente
Abstract:
In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS process, capacitively coupled to hybrid pixel readout chips. Recent results have shown the approach to be feasible, though more detailed studies of the performa…
▽ More
In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS process, capacitively coupled to hybrid pixel readout chips. Recent results have shown the approach to be feasible, though more detailed studies of the performance of such devices, including simulation, are required. The CLICdp collaboration has developed a number of ASICs as part of its vertex detector R&D programme, and here we present results on the performance of a CCPDv3 active sensor glued to a CLICpix readout chip. Charge collection characteristics and tracking performance have been measured over the full expected angular range of incident particles using 120 GeV/c secondary hadron beams from the CERN SPS. Single hit efficiencies have been observed above 99% in the full range of track incidence angles, down to shallow angles. The single hit resolution has also been observed to be stable over this range, with a resolution around 6 $μ$m. The measured charge collection characterstics have been compared to simulations carried out using the Sentaurus TCAD finite-element simulation package combined with circuit simulations and parametrisations of the readout chip response. The simulations have also been successfully used to reproduce electric fields, depletion depths and the current-voltage characteristics of the device, and have been further used to make predictions about future device designs.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
Time Resolution Studies with Timepix3 Assemblies with Thin Silicon Pixel Sensors
Authors:
Florian Pitters,
Nilou Alipour Tehrani,
Dominik Dannheim,
Adrian Fiergolski,
Daniel Hynds,
Wolfgang Klempt,
Xavi Llopart,
Magdalena Munker,
Andreas Nürnberg,
Simon Spannagel,
Morag Williams
Abstract:
Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and energy simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by timewalk. In this paper, a method for pixel-by-pixel calibration of the time response is presented. Assemblies of Timepix3 ASICs bump-bonded to thin planar silicon…
▽ More
Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and energy simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by timewalk. In this paper, a method for pixel-by-pixel calibration of the time response is presented. Assemblies of Timepix3 ASICs bump-bonded to thin planar silicon pixel sensors of different thicknesses between 50 um and 150 um are calibrated and characterised in particle beams. For minimum ionising particles, time resolutions down to 0.72 $\pm$ 0.04 ns are achieved.
△ Less
Submitted 10 March, 2019; v1 submitted 21 January, 2019;
originally announced January 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Top-Quark Physics at the CLIC Electron-Positron Linear Collider
Authors:
H. Abramowicz,
N. Alipour Tehrani,
D. Arominski,
Y. Benhammou,
M. Benoit,
J. -J. Blaising,
M. Boronat,
O. Borysov,
R. R. Bosley,
I. Božović Jelisavčić,
I. Boyko,
S. Brass,
E. Brondolin,
P. Bruckman de Renstrom,
M. Buckland,
P. N. Burrows,
M. Chefdeville,
S. Chekanov,
T. Coates,
D. Dannheim,
M. Demarteau,
H. Denizli,
G. Durieux,
G. Eigen,
K. Elsener
, et al. (92 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boso…
▽ More
The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of ttH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.
△ Less
Submitted 18 November, 2019; v1 submitted 6 July, 2018;
originally announced July 2018.
-
Higgs Physics at the CLIC Electron-Positron Linear Collider
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
N. Alipour Tehrani,
C. Balázs,
Y. Benhammou,
M. Benoit,
B. Bilki,
J. -J. Blaising,
M. J. Boland,
M. Boronat,
O. Borysov,
I. Božović-Jelisavčić,
M. Buckland,
S. Bugiel,
P. N. Burrows,
T. K. Charles,
W. Daniluk,
D. Dannheim,
R. Dasgupta,
M. Demarteau,
M. A. Díaz Gutierrez,
G. Eigen,
K. Elsener,
U. Felzmann
, et al. (99 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3…
▽ More
The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3 TeV. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (e+e- -> ZH) and WW-fusion (e+e- -> Hnunu), resulting in precise measurements of the production cross sections, the Higgs total decay width Gamma_H, and model-independent determinations of the Higgs couplings. Operation at sqrt(s) > 1 TeV provides high-statistics samples of Higgs bosons produced through WW-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes e+e- -> ttH and e+e- -> HHnunu allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.
△ Less
Submitted 5 June, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.