-
Neutrino interactions at COMET
Authors:
D. Mulmule
Abstract:
The experimental search for coherent neutrinoless conversion of muon to electron in the presence of a nucleus, aims to probe the possibility of charged lepton flavour violation. The COMET experiment at J-PARC is one such setup offering unprecedented statistical reach, with single event sensitivities down to $\mathcal{O}$ ($\mathrm{10^{-17}}$). Its successor experiment - PRISM, planned as the final…
▽ More
The experimental search for coherent neutrinoless conversion of muon to electron in the presence of a nucleus, aims to probe the possibility of charged lepton flavour violation. The COMET experiment at J-PARC is one such setup offering unprecedented statistical reach, with single event sensitivities down to $\mathcal{O}$ ($\mathrm{10^{-17}}$). Its successor experiment - PRISM, planned as the final stage, is expected to take this bound further down by two orders of magnitude. The electrons from standard model decay of bound muons are considered the most formidable physics background to the detection of these conversion electrons. Kee** in view the high stopped muon statistics for COMET and PRISM, the rate of charged current interaction of decay neutrinos with nuclear protons is also non-negligible. In this work, we perform a calculation of the positron event rates expected due to interactions of electron antineutrinos with Al target protons in the COMET setup. About $\mathrm{7\pm1}$ such $\mathrm{e^{+}}$ events per $\mathrm{10^{18}}$stopped muons are expected.
△ Less
Submitted 29 December, 2021;
originally announced January 2022.
-
Measurements using a prototype array of plastic scintillator bars for reactor based electron anti-neutrino detection
Authors:
P. K. Netrakanti,
D. Mulmule,
D. K. Mishra,
S. P. Behera,
R. Dey,
R. Sehgal,
S. K. Sinha,
V. Jha,
L. M. Pant
Abstract:
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy d…
▽ More
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy deposition, number of bars hit as well as topological event selection criteria in position and time. Each of these selection criteria are compared with Monte Carlo based simulations and further an embedding technique is used to estimate the efficiencies from a data driven background study. The obtained anti-neutrino like events in RON condition are 218 $\pm$ 50 (stat) $\pm$ 37 (sys) after background subtraction. The obtained results are compared with theoretical estimation which yields 214 $\pm$ 32 (sys) anti-neutrino events for the RON condition.
△ Less
Submitted 28 December, 2021; v1 submitted 24 December, 2021;
originally announced December 2021.
-
Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
D. Mulmule,
T. Patel,
P. S. Sarkar,
V. Jha,
L. M. Pant
Abstract:
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse…
▽ More
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fast neutron response in PS bars is an essential pre-requisite for suppression and discrimination of fast neutron background from IBD events. A monoenergetic neutron beam from the fusion reaction of D-D at 2.45 MeV and D-T at 14.1 MeV are used to characterize the energy response in these bars. The neutron energy response function has been simulated using the GEANT4 package and are compared with the measured data. A reasonable agreement of deposited energies by fast neutrons in PS bars between data and simulation are obtained for these reactions. The ratio of energy deposition in adjacent bars is used to discriminate between prompt IBD, fast neutron and neutron capture cascade gamma events.
△ Less
Submitted 4 November, 2021; v1 submitted 15 October, 2021;
originally announced October 2021.
-
Machine learning technique to improve anti-neutrino detection efficiency for the ISMRAN experiment
Authors:
D. Mulmule,
P. K. Netrakanti,
L. M. Pant,
B. K. Nayak
Abstract:
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and…
▽ More
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and delayed neutron from IBD will provide the signature of $\barν_e$ event in ISMRAN. The number of segments with energy deposit ($\mathrm{N_{bars}}$) and sum total of these deposited energies are used as discriminants for identifying prompt positron event and delayed neutron capture event. However, a simple cut based selection of above variables leads to a low $\barν_e$ signal detection efficiency due to overlap** region of $\mathrm{N_{bars}}$ and sum energy for the prompt and delayed events. Multivariate analysis (MVA) tools, employing variables suitably tuned for discrimination, can be useful in such scenarios. In this work we report the results from an application of artificial neural network -- the multilayer perceptron (MLP), particularly the Bayesian extension -- MLPBNN, to the simulated signal and background events in ISMRAN. The results from application of MLP to classify prompt positron events from delayed neutron capture events on Hydrogen, Gadolinium nuclei and also from the typical reactor $γ$-ray and fast neutron backgrounds is reported. An enhanced efficiency of $\sim$91$\%$ with a background rejection of $\sim$73$\%$ for prompt selection and an efficiency of $\sim$89$\%$ with a background rejection of $\sim$71$\%$ for the delayed capture event, is achieved using the MLPBNN classifier for the ISMRAN experiment.
△ Less
Submitted 20 May, 2020; v1 submitted 2 January, 2020;
originally announced January 2020.
-
Applied Antineutrino Physics 2018 Proceedings
Authors:
M. Bergevin,
N. Bowden,
H. P. Mumm,
M. Verstraeten,
J. Park,
B. Han,
Y. Shitov,
A. P. Serebrov,
A. Onillon,
G. Karagiorgi,
K. Nakajima,
P. Chimenti,
J. Coleman,
M. Askins,
L. Marti-Magro,
T. Hill,
R. Carr,
J. Johnston,
A. N. Mabe,
M. Yeh,
G. D. Orebi Gann,
M. P. Mendenhall,
D. Mulmule,
D. L. Danielson,
J. G. Learned
Abstract:
Proceedings for the 14th installment of Applied Antineutrino Physics (AAP) workshop series.
Proceedings for the 14th installment of Applied Antineutrino Physics (AAP) workshop series.
△ Less
Submitted 9 December, 2019; v1 submitted 15 November, 2019;
originally announced November 2019.
-
A plastic scintillator array for reactor based anti-neutrino studies
Authors:
D. Mulmule,
S. P. Behera,
P. K. Netrakanti,
D. K. Mishra,
V. K. S. Kashyap,
V. Jha,
L. M. Pant,
B. K. Nayak,
A. Saxena
Abstract:
Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event cha…
▽ More
Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event characterization in the reactor and non-reactor environment. The data acquisition system based on waveform digitizers is being used for pulse processing and event triggering. Monte-Carlo based simulations using GEANT4 are performed to optimize lead (Pb) and borated polyethylene (BP) shielding for background reduction and to study the positron, neutron and $γ$-ray response in the ISMRAN detector. Characterization of plastic scintillator detectors with known radioactive sources is done for energy, timing and position measurements. Using the energy summation and bar multiplicity selection, coincident events from $\mathrm{{}^{60}Co}$ decay are reconstructed in non-reactor environment. Results from background measurements using various detectors are quantified in reactor ON and OFF condition. The shielding of 10 cm Pb and 10 cm BP along with the requirement of hits in multiple bars, reduces the uncorrelated background in reactor ON condition.
△ Less
Submitted 6 December, 2018; v1 submitted 12 June, 2018;
originally announced June 2018.