-
An ion trap design for a space-deployable strontium-ion optical clock
Authors:
Alessio Spampinato,
Jonathan Stacey,
Sean Mulholland,
Billy I. Robertson,
Hugh A. Klein,
Guilong Huang,
Geoffrey P. Barwood,
Patrick Gill
Abstract:
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and po…
▽ More
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and portable devices at this capability level. In this paper we discuss the design of a physics package for a compact laser-cooled 88Sr+ optical clock that would, with further development, be suitable for space deployment. We review the design parameters to target a relative frequency uncertainty at the low parts in 10^18 with this system. We then explain the results of finite element modelling to simulate the response of the ion trap and vacuum chamber to vibration, shock and thermal conditions expected during launch and space deployment. Additionally, an electrostatic model has been developed to investigate the relationship between the ion trap geometrical tolerances and the trap** efficiency. We present the results from these analyses that have led to the design of a more robust prototype ready for experimental testing.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
Frequency stability and phase noise measurements of a 5,860 km-long intercontinental seafloor optical fibre cable
Authors:
Giuseppe Marra,
Paul Gaynor,
Mattia Cantono,
Valey Kamalov,
Sean Mulholland,
Ian Hill,
Marco Schioppo,
Jacques-Olivier Gaudron,
Irene-Barbeito Edreira,
Cecilia Clivati,
Davide Calonico
Abstract:
Optical clock comparison via optical fibre links has been achieved over continental scales, but has not yet been demonstrated intercontinentally. The transfer of ultra-stable optical frequencies over transoceanic distances is a challenging task, as the seafloor cable architecture prevents the use of environmental noise suppression techniques currently employed on land-based metrological links. As…
▽ More
Optical clock comparison via optical fibre links has been achieved over continental scales, but has not yet been demonstrated intercontinentally. The transfer of ultra-stable optical frequencies over transoceanic distances is a challenging task, as the seafloor cable architecture prevents the use of environmental noise suppression techniques currently employed on land-based metrological links. As a fundamental first step towards devising suitable frequency transfer techniques to enable future clock comparison on a global scale, here we show the free-running frequency stability and phase noise measurements of a transatlantic seafloor optical link between the UK and Canada. To the best of our knowledge, these are the first ever measurements of an intercontinental optical fibre link.
△ Less
Submitted 5 December, 2022;
originally announced December 2022.
-
Compact laser system for a laser-cooled ytterbium ion microwave frequency standard
Authors:
S. Mulholland,
H. A. Klein,
G. P. Barwood,
S. Donnellan,
P. B. R. Nisbet-Jones,
G. Huang,
G. Walsh,
P. E. G. Baird,
P. Gill
Abstract:
The development of a transportable microwave frequency standard based on the ground-state transition of $^{171}\mathrm{Yb^{+}}$ at ~12.6 GHz requires a compact laser system for cooling the ions, clearing out of long-lived states and also for photoionisation. In this paper, we describe the development of a suitable compact laser system based on a 6U height rack-mounted arrangement with overall dime…
▽ More
The development of a transportable microwave frequency standard based on the ground-state transition of $^{171}\mathrm{Yb^{+}}$ at ~12.6 GHz requires a compact laser system for cooling the ions, clearing out of long-lived states and also for photoionisation. In this paper, we describe the development of a suitable compact laser system based on a 6U height rack-mounted arrangement with overall dimensions $260 \times 194 \times 335$ mm. Laser outputs at 369 nm (for cooling), 399 nm (photoionisation), 935 nm (repum**) and 760 nm (state clearout) are combined in a fiber arrangement for delivery to our linear ion trap and we demonstrate this system by cooling of $^{171}\mathrm{Yb^{+}}$ ions. Additionally, we demonstrate that the lasers at 935 nm and 760 nm are close in frequency to water vapor and oxygen absorption lines respectively; specifically, at 760 nm, we show that one $^{171}\mathrm{Yb^{+}}$ transition is within the pressure broadened profile of an oxygen line. These molecular transitions form convenient wavelength references for the stabilization of lasers for a $^{171}\mathrm{Yb^{+}}$ frequency standard.
△ Less
Submitted 27 March, 2019; v1 submitted 26 November, 2018;
originally announced November 2018.
-
Laser-cooled ytterbium ion frequency standard
Authors:
S. Mulholland,
H. A. Klein,
G. P. Barwood,
S. Donnellan,
D. Gentle,
G. Huang,
G. Walsh,
P. E. G. Baird,
P. Gill
Abstract:
We report on the development of a trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit ($51\times49\times28$ cm) and comprises laser, electronics, and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was meas…
▽ More
We report on the development of a trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit ($51\times49\times28$ cm) and comprises laser, electronics, and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was measured to be $3.6\times10^{-12}/\surdĪ$ for averaging times between 30 s and 1500 s.
△ Less
Submitted 10 October, 2019; v1 submitted 15 November, 2018;
originally announced November 2018.