Skip to main content

Showing 1–9 of 9 results for author: Muhl, C

.
  1. arXiv:2303.17046  [pdf, other

    cs.LG cs.AI cs.CR

    Have it your way: Individualized Privacy Assignment for DP-SGD

    Authors: Franziska Boenisch, Christopher Mühl, Adam Dziedzic, Roy Rinberg, Nicolas Papernot

    Abstract: When training a machine learning model with differential privacy, one sets a privacy budget. This budget represents a maximal privacy violation that any user is willing to face by contributing their data to the training set. We argue that this approach is limited because different users may have different privacy expectations. Thus, setting a uniform privacy budget across all points may be overly… ▽ More

    Submitted 19 January, 2024; v1 submitted 29 March, 2023; originally announced March 2023.

    Comments: Published at NeurIPS'2024

  2. arXiv:2202.10517  [pdf, other

    cs.LG cs.CR

    Individualized PATE: Differentially Private Machine Learning with Individual Privacy Guarantees

    Authors: Franziska Boenisch, Christopher Mühl, Roy Rinberg, Jannis Ihrig, Adam Dziedzic

    Abstract: Applying machine learning (ML) to sensitive domains requires privacy protection of the underlying training data through formal privacy frameworks, such as differential privacy (DP). Yet, usually, the privacy of the training data comes at the cost of the resulting ML models' utility. One reason for this is that DP uses one uniform privacy budget epsilon for all training data points, which has to al… ▽ More

    Submitted 8 November, 2022; v1 submitted 21 February, 2022; originally announced February 2022.

    Comments: accepted for publication at PoPETs'23

  3. arXiv:1810.12064  [pdf, other

    cond-mat.soft physics.bio-ph q-bio.BM

    Poly-Sarcosine and Poly(ethylene-glycol) interactions with proteins investigated using molecular dynamics simulations

    Authors: Giovanni Settanni, Timo Schäfer, Christian Muhl, Matthias Barz, Friederike Schmid

    Abstract: Nanoparticles coated with hydrophilic polymers often show a reduction in unspecific interactions with the biological environment, which improves their biocompatibility. The molecular determinants of this reduction are not very well understood yet, and their knowledge may help improving nanoparticle design. Here we address, using molecular dynamics simulations, the interactions of human serum album… ▽ More

    Submitted 29 October, 2018; originally announced October 2018.

  4. arXiv:1706.00222  [pdf, other

    physics.ins-det hep-ex

    Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    Authors: M. Dragicevic, M. Friedl, J. Hrubec, H. Steininger, A. Gädda, J. Härkönen, T. Lampén, P. Luukka, T. Peltola, E. Tuominen, E. Tuovinen, A. Winkler, P. Eerola, T. Tuuva, G. Baulieu, G. Boudoul, L. Caponetto, C. Combaret, D. Contardo, T. Dupasquier, G. Gallbit, N. Lumb, L. Mirabito, S. Perries, M. Vander Donckt , et al. (462 additional authors not shown)

    Abstract: A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator… ▽ More

    Submitted 1 June, 2017; originally announced June 2017.

    Report number: CMS-NOTE-2017-002

  5. arXiv:1603.09669  [pdf, other

    physics.ins-det hep-ex

    Performance of the EUDET-type beam telescopes

    Authors: H. Jansen, S. Spannagel, J. Behr, A. Bulgheroni, G. Claus, E. Corrin, D. G. Cussans, J. Dreyling-Eschweiler, D. Eckstein, T. Eichhorn, M. Goffe, I. M. Gregor, D. Haas, C. Muhl, H. Perrey, R. Peschke, P. Roloff, I. Rubinskiy, M. Winter

    Abstract: Test beam measurements at the test beam facilities of DESY have been conducted to characterise the performance of the EUDET-type beam telescopes originally developed within the EUDET project. The beam telescopes are equipped with six sensor planes using MIMOSA26 monolithic active pixel devices. A programmable Trigger Logic Unit provides trigger logic and time stamp information on particle passage.… ▽ More

    Submitted 10 May, 2016; v1 submitted 31 March, 2016; originally announced March 2016.

    Report number: DESY 16-055

  6. Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023

  7. arXiv:1311.2222  [pdf, other

    cs.HC

    Review of the Use of Electroencephalography as an Evaluation Method for Human-Computer Interaction

    Authors: Jérémy Frey, Christian Mühl, Fabien Lotte, Martin Hachet

    Abstract: Evaluating human-computer interaction is essential as a broadening population uses machines, sometimes in sensitive contexts. However, traditional evaluation methods may fail to combine real-time measures, an "objective" approach and data contextualization. In this review we look at how adding neuroimaging techniques can respond to such needs. We focus on electroencephalography (EEG), as it could… ▽ More

    Submitted 9 November, 2013; originally announced November 2013.

    Comments: PhyCS 2014 - International Conference on Physiological Computing Systems (2014)

  8. arXiv:1201.4657  [pdf

    physics.ins-det hep-ex

    Infrastructure for Detector Research and Development towards the International Linear Collider

    Authors: J. Aguilar, P. Ambalathankandy, T. Fiutowski, M. Idzik, Sz. Kulis, D. Przyborowski, K. Swientek, A. Bamberger, M. Köhli, M. Lupberger, U. Renz, M. Schumacher, Andreas Zwerger, A. Calderone, D. G. Cussans, H. F. Heath, S. Mandry, R. F. Page, J. J. Velthuis, D. Attié, D. Calvet, P. Colas, X. Coppolani, Y. Degerli, E. Delagnes , et al. (252 additional authors not shown)

    Abstract: The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras… ▽ More

    Submitted 23 January, 2012; originally announced January 2012.

    Comments: 54 pages, 48 pictures

  9. Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment

    Authors: The ZEUS FNC Group, S. Bhadra, I. Bohnet, M. Cardy, U. Dosselli, C. -P. Fagerstroem, W. Frisken, K. Furutani, D. Hanna, U. Holm, K. F. Johnson, M. Khakzad, G. Levman, J. N. Lim, B. Loehr, J. F. Martin, C. Muhl, T. Neumann, M. Rohde, W. B. Schmidke, D. G. Stairs, H. Tiecke, C. Voci

    Abstract: A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in charge exchange ep collisions. Before installation the calorimeter was tested and calibrated in the H6 beam at CERN where 120 GeV electrons, muons, pions and p… ▽ More

    Submitted 27 January, 1997; originally announced January 1997.

    Comments: 45 pages, 22 Encapsulated Postscript figures, submitted to Nuclear Instruments and Methods

    Report number: DESY 97-006

    Journal ref: Nucl.Instrum.Meth.A394:121-135,1997