Electrical Grid Anomaly Detection via Tensor Decomposition
Authors:
Alexander Most,
Maksim Eren,
Nigel Lawrence,
Boian Alexandrov
Abstract:
Supervisory Control and Data Acquisition (SCADA) systems often serve as the nervous system for substations within power grids. These systems facilitate real-time monitoring, data acquisition, control of equipment, and ensure smooth and efficient operation of the substation and its connected devices. Previous work has shown that dimensionality reduction-based approaches, such as Principal Component…
▽ More
Supervisory Control and Data Acquisition (SCADA) systems often serve as the nervous system for substations within power grids. These systems facilitate real-time monitoring, data acquisition, control of equipment, and ensure smooth and efficient operation of the substation and its connected devices. Previous work has shown that dimensionality reduction-based approaches, such as Principal Component Analysis (PCA), can be used for accurate identification of anomalies in SCADA systems. While not specifically applied to SCADA, non-negative matrix factorization (NMF) has shown strong results at detecting anomalies in wireless sensor networks. These unsupervised approaches model the normal or expected behavior and detect the unseen types of attacks or anomalies by identifying the events that deviate from the expected behavior. These approaches; however, do not model the complex and multi-dimensional interactions that are naturally present in SCADA systems. Differently, non-negative tensor decomposition is a powerful unsupervised machine learning (ML) method that can model the complex and multi-faceted activity details of SCADA events. In this work, we novelly apply the tensor decomposition method Canonical Polyadic Alternating Poisson Regression (CP-APR) with a probabilistic framework, which has previously shown state-of-the-art anomaly detection results on cyber network data, to identify anomalies in SCADA systems. We showcase that the use of statistical behavior analysis of SCADA communication with tensor decomposition improves the specificity and accuracy of identifying anomalies in electrical grid systems. In our experiments, we model real-world SCADA system data collected from the electrical grid operated by Los Alamos National Laboratory (LANL) which provides transmission and distribution service through a partnership with Los Alamos County, and detect synthetically generated anomalies.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
The Longitudinal Polarimeter at HERA
Authors:
M. Beckmann,
A. Borissov,
S. Brauksiepe,
F. Burkart,
H. Fischer,
J. Franz,
F. H. Heinsius,
K. Konigsmann,
W. Lorenzon,
F. M. Menden,
A. Most,
S. Rudnitsky,
C. Schill,
J. Seibert,
A. Simon
Abstract:
The design, construction and operation of a Compton back-scattering laser polarimeter at the HERA storage ring at DESY are described. The device measures the longitudinal polarization of the electron beam between the spin rotators at the HERMES experiment with a fractional systematic uncertainty of 1.6%. A measurement of the beam polarization to an absolute statistical precision of 0.01 requires…
▽ More
The design, construction and operation of a Compton back-scattering laser polarimeter at the HERA storage ring at DESY are described. The device measures the longitudinal polarization of the electron beam between the spin rotators at the HERMES experiment with a fractional systematic uncertainty of 1.6%. A measurement of the beam polarization to an absolute statistical precision of 0.01 requires typically one minute when the device is operated in the multi-photon mode. The polarimeter also measures the polarization of each individual electron bunch to an absolute statistical precision of 0.06 in approximately five minutes. It was found that colliding and non-colliding bunches can have substantially different polarizations. This information is important to the collider experiments H1 and ZEUS for their future longitudinally polarized electron program because those experiments use the colliding bunches only.
△ Less
Submitted 13 September, 2000;
originally announced September 2000.
-
The Structure Function Ratios F2(Li)/F2(D) and F2(C)/F2(D) at small x
Authors:
THE NEW MUON COLLABORATION,
M. Arneodo,
A. Arvidson,
B. Badelek,
M. Ballintijn,
G. Baum,
J. Beaufays,
I. G. Bird,
P. Bjorkholm,
M. Botje,
C. Broggini,
W. Bruckner,
A. Brull,
W. J. Burger,
J. Ciborowski,
R. van~Dantzig,
A. Dyring,
H. Engelien,
M. I. Ferrero,
L. Fluri,
U. Gaul,
T. Granier,
M. Grosse-Perdekamp,
D. von~Harrach,
M. van~der~Heijden
, et al. (49 additional authors not shown)
Abstract:
We present the structure function ratios F2(Li)/F2(D) and F2(C)/F2(D) measured in deep inelastic muon-nucleus scattering at a nominal incident muon energy of 200 GeV. The kinematic range 0.0001 < x < 0.7 and 0.01< Q^2 < 70 GeV^2 is covered. For values of $x$ less than $0.002$ both ratios indicate saturation of shadowing at values compatible with photoabsorption results.
We present the structure function ratios F2(Li)/F2(D) and F2(C)/F2(D) measured in deep inelastic muon-nucleus scattering at a nominal incident muon energy of 200 GeV. The kinematic range 0.0001 < x < 0.7 and 0.01< Q^2 < 70 GeV^2 is covered. For values of $x$ less than $0.002$ both ratios indicate saturation of shadowing at values compatible with photoabsorption results.
△ Less
Submitted 3 April, 1995;
originally announced April 1995.