-
3D-Plotting Algorithm for Insects using YOLOv5
Authors:
Daisuke Mori,
Hiroki Hayami,
Yasufumi Fujimoto,
Isao Goto
Abstract:
In ecological research, accurately collecting spatiotemporal position data is a fundamental task for understanding the behavior and ecology of insects and other organisms. In recent years, advancements in computer vision techniques have reached a stage of maturity where they can support, and in some cases, replace manual observation. In this study, a simple and inexpensive method for monitoring in…
▽ More
In ecological research, accurately collecting spatiotemporal position data is a fundamental task for understanding the behavior and ecology of insects and other organisms. In recent years, advancements in computer vision techniques have reached a stage of maturity where they can support, and in some cases, replace manual observation. In this study, a simple and inexpensive method for monitoring insects in three dimensions (3D) was developed so that their behavior could be observed automatically in experimental environments. The main achievements of this study have been to create a 3D monitoring algorithm using inexpensive cameras and other equipment to design an adjusting algorithm for depth error, and to validate how our plotting algorithm is quantitatively precise, all of which had not been realized in conventional studies. By offering detailed 3D visualizations of insects, the plotting algorithm aids researchers in more effectively comprehending how insects interact within their environments.
△ Less
Submitted 31 January, 2024;
originally announced January 2024.
-
Mechanism of intermetallic charge transfer and bond disproportionation in BiNiO$_3$ and PbNiO$_3$ revealed by hard x-ray photoemission spectroscopy
Authors:
Tatsuya Yamaguchi,
Mizuki Furo,
Yuki Sakai,
Takumi Nishikubo,
Hajime Hojo,
Masaki Azuma,
Kengo Oka,
Daisuke Mori,
Yoshiyuki Inaguma,
Masaichiro Mizumaki,
Kento Yamamoto,
Jan Kuneš,
Takashi Mizokawa,
Atsushi Hariki
Abstract:
Perovskites with Bi or Pb on the A-site host a number of interesting and yet to be understood phenomena such as negative thermal expansion in BiNiO$_3$. We employ hard x-ray photoemission spectroscopy of Ni 2$p$ core-level as well as valence band to probe the electronic structure of BiNiO$_3$ and PbNiO$_3$. The experimental results supported by theoretical calculations using dynamical mean-field t…
▽ More
Perovskites with Bi or Pb on the A-site host a number of interesting and yet to be understood phenomena such as negative thermal expansion in BiNiO$_3$. We employ hard x-ray photoemission spectroscopy of Ni 2$p$ core-level as well as valence band to probe the electronic structure of BiNiO$_3$ and PbNiO$_3$. The experimental results supported by theoretical calculations using dynamical mean-field theory reveal essentially identical electronic structure of the Ni-O subsystem typical of Ni$^{2+}$ charge-transfer insulators. The two materials are distinguished by filling of the Bi(Pb)-O antibonding states in the vicinity of the Fermi level, which is responsible for the Bi disproportionation in BiNiO$_3$ at ambient pressure and absence of similar behavior in PbNiO$_3$. The present experiments provide evidence for this conclusion by revealing the presence/absence of Bi/Pb $6s$ states at the top of the valence band in the two materials.
△ Less
Submitted 13 May, 2024; v1 submitted 19 December, 2023;
originally announced December 2023.
-
Development of the Thomson scattering measurement system for cascade arc device with indirectly heated hollow cathode
Authors:
K. Yamasaki,
K. Okuda,
J. Kono,
A. Saito,
D. Mori,
R. Suzuki,
Y. Kambara,
R. Hamada,
S. Namba,
K. Tomita,
Y. Pan,
N. Tamura,
C. Suzuki,
H. Okuno
Abstract:
We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. The PW is one of the plasma application techniques that sustain the steep pressure gradient between high pressure (10-100 kPa) and a vacuum environment due to the thermal energy of the plasma. Since the plasma thermal energy is the essential paramete…
▽ More
We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. The PW is one of the plasma application techniques that sustain the steep pressure gradient between high pressure (10-100 kPa) and a vacuum environment due to the thermal energy of the plasma. Since the plasma thermal energy is the essential parameter for the pressure separation capability of PW, we installed the Thomson scattering measurement system to observe the electron density and temperature within the anode and cathode of the PW for the detailed analysis of the pressure separation capability. The frequency-doubled Nd:YAG laser (532 nm, 200 mJ, 8 ns) was employed for the probe laser. The scattered light was fed to the triple grating spectrometer. The notch filter between the first and second grating eliminated the stray light, realizing a sufficiently high signal-to-noise ratio. The Thomson scattering measurement system successfully obtained the electron density and temperature of the cascade arc plasma at 20 mm downstream from the tip of the cathode. The installed system successfully obtained the Thomson scattering spectrum and showed that the electron density increased from $2\times10^{19} {\rm m}^{-3}$ to $7\times10^{19} {\rm m}^{-3}$ with the discharge power, while the electron temperature was almost constant at about 2 eV. The obtained data successfully contributed to the study of the pressure separation capability of the PW.
△ Less
Submitted 10 October, 2023; v1 submitted 30 August, 2023;
originally announced August 2023.
-
Image reconstruction method for dual-isotope positron emission tomography
Authors:
Tomonori Fukuchi,
Mika Shigeta,
Hiromitsu Haba,
Daiki Mori,
Takuya Yokokita,
Yukiko Komori,
Seiichi Yamamoto,
Yasuyoshi Watanabe
Abstract:
We developed a positron emission tomography (PET) system for multiple-isotope imaging. Our PET system, named multiple-isotope PET (MI-PET), can distinguish between different tracer nuclides using coincidence measurement of prompt gamma-rays, which are emitted after positron emission. In MI-PET imaging with a pure positron emitter and prompt-gamma emitter, because of the imperfectness of prompt gam…
▽ More
We developed a positron emission tomography (PET) system for multiple-isotope imaging. Our PET system, named multiple-isotope PET (MI-PET), can distinguish between different tracer nuclides using coincidence measurement of prompt gamma-rays, which are emitted after positron emission. In MI-PET imaging with a pure positron emitter and prompt-gamma emitter, because of the imperfectness of prompt gamma-ray detection, an image for a pure positron emitter taken by MI-PET is superposed by a positron-γ emitter. Therefore, in order to make isolated images of the pure positron emitter, we developed image reconstruction methods based on data subtraction specific to MI-PET. We tested two methods, subtraction between reconstructed images and subtraction between sinogram data. In both methods, normalization for position dependence of the prompt γ-ray sensitivity is required in addition to detector sensitivity normalization. For these normalizations, we performed normalization scans using cylindrical phantoms of the positron-gamma emitters Sc-44m and Na-22. A long period measurement using the activity decay of Sc-44m (Half-life 58.6 hours) elucidated that the acquisition ratio between the prompt gamma-rays coincided with PET event and pure PET event changes on the basis of object activities. Therefore, we developed a correction method that involves subtraction parameters dependent on the activities, i.e., the counting rate. From analysis of dual-tracer phantom images, data subtraction in the sinogram data with sensitivity correction gives a higher quality of isolated images for the pure positron emitter than those from image subtractions. Furthermore, from dual-isotope (F-18-FDG and Sc-44m) mouse imaging, we concluded that our developed method can be used for practical imaging of a living organism.
△ Less
Submitted 31 January, 2021;
originally announced February 2021.
-
Performance of a Full-Size Small-Strip Thin Gap Chamber Prototype for the ATLAS New Small Wheel Muon Upgrade
Authors:
Angel Abusleme,
Camille Bélanger-Champagne,
Alain Bellerive,
Yan Benhammou,
James Botte,
Hadar Cohen,
Merlin Davies,
Yanyan Du,
Lea Gauthier,
Thomas Koffas,
Serguei Kuleshov,
Benoit Lefebvre,
Changyu Li,
Nachman Lupu,
Giora Mikenberg,
Daniel Mori,
Jean-Pierre Ochoa-Ricoux,
Estel Perez Codina,
Sebastien Rettie,
Andree Robichaud-Véronneau,
Rimsky Rojas,
Meir Shoa,
Vladimir Smakhtin,
Bernd Stelzer,
Oliver Stelzer-Chilton
, et al. (10 additional authors not shown)
Abstract:
The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs…
▽ More
The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs will be installed during the LHC long shutdown in 2018/19. Small-Strip Thin Gap Chamber (sTGC) detectors are designed to provide fast trigger and high precision muon tracking under the high luminosity LHC conditions. To validate the design, a full-size prototype sTGC detector of approximately 1.2 $\times$ $1.0\, \mathrm{m}^2$ consisting of four gaps has been constructed. Each gap provides pad, strip and wire readouts. The sTGC intrinsic spatial resolution has been measured in a $32\, \mathrm{GeV}$ pion beam test at Fermilab. At perpendicular incidence angle, single gap position resolutions of about $50\,\mathrm{μm}$ have been obtained, uniform along the sTGC strip and perpendicular wire directions, well within design requirements. Pad readout measurements have been performed in a $130\, \mathrm{GeV}$ muon beam test at CERN. The transition region between readout pads has been found to be $4\,\mathrm{mm}$, and the pads have been found to be fully efficient.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
Estereoscopio de Wheatstone 'Revival'
Authors:
Jose Joaquin Lunazzi,
Milena Cardoso Franca,
Andrey da Silva Mori
Abstract:
We describe the making of a two-mirrors stereoscope, identical to the first historical one, with the advantage of employing digital images on LCD monitors. We surprised the public with it, because they do not imagine being possible to watch 3D without needing goggless, neither the lack of knowledge of something so simple and old. Nowadays it is common to have two monitors at the exit of a computer…
▽ More
We describe the making of a two-mirrors stereoscope, identical to the first historical one, with the advantage of employing digital images on LCD monitors. We surprised the public with it, because they do not imagine being possible to watch 3D without needing goggless, neither the lack of knowledge of something so simple and old. Nowadays it is common to have two monitors at the exit of a computer, so that the system is still a simple one.
△ Less
Submitted 14 August, 2014;
originally announced August 2014.