-
The Planck-LFI flight model composite waveguides
Authors:
O. D'Arcangelo,
L. Figini,
A. Simonetto,
F. Villa,
M. Pecora,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
S. Garavaglia,
P. Guzzi,
N. Mandolesi,
A. Mennella,
G. Morgante,
L. Pagan,
L. Valenziano
Abstract:
The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts…
▽ More
The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts is made with rectangular Wave Guides. Considerations of different nature (thermal, electromagnetic and mechanical), imposed stringent requirements on the WGs characteristics and drove their design. From the thermal point of view, the WG should guarantee good insulation between the FEM and the BEM sections to avoid overloading the cryocooler. On the other hand it is essential that the signals do not undergo excessive attenuation through the WG. Finally, given the different positions of the FEM modules behind the focal surface and the mechanical constraints given by the surrounding structures, different mechanical designs were necessary. A composite configuration of Stainless Steel and Copper was selected to satisfy all the requirements. Given the complex shape and the considerable length (about 1.5-2 m), manufacturing and testing the WGs was a challenge. This work deals with the development of the LFI WGs, including the choice of the final configuration and of the fabrication process. It also describes the testing procedure adopted to fully characterize these components from the electromagnetic point of view and the space qualification process they underwent. Results obtained during the test campaign are reported and compared with the stringent requirements. The performance of the LFI WGs is in line with requirements, and the WGs were successfully space qualified.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Thermal susceptibility of the Planck-LFI receivers
Authors:
L Terenzi,
M J Salmon,
A Colin,
A Mennella,
G Morgante,
M Tomasi,
P Battaglia,
M Lapolla,
M Bersanelli,
R C Butler,
F Cuttaia,
O D'Arcangelo,
R Davis,
C Franceschet,
S Galeotta,
A Gregorio,
N Hughes,
P Jukkala,
D Kettle,
M Laaninen,
P Leutenegger,
R Leonardi,
N Mandolesi,
M Maris,
P Meinhold
, et al. (11 additional authors not shown)
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st .
This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on t…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st .
This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on the receivers signal is described. The experimental test setup dedicated to evaluate these effects during the instrument ground calibration is reported together with data analysis methods. Finally, main results obtained are discussed and compared to the requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Dynamic validation of the Planck/LFI thermal model
Authors:
M. Tomasi,
B. Cappellini,
A. Gregorio,
F. Colombo,
M. Lapolla,
L. Terenzi,
G. Morgante,
M. Bersanelli,
R. C. Butler,
S. Galeotta,
N. Mandolesi,
M. Maris,
A. Mennella,
L. Valenziano,
A. Zacchei
Abstract:
The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies of the cosmic microwave backgrond (CMB) at 30, 44 and 70 GHz. The thermal requirements of the LFI, and in particular the stringent limits to acceptable thermal fluctuations in the 20 K focal plane, are a critical eleme…
▽ More
The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies of the cosmic microwave backgrond (CMB) at 30, 44 and 70 GHz. The thermal requirements of the LFI, and in particular the stringent limits to acceptable thermal fluctuations in the 20 K focal plane, are a critical element to achieve the instrument scientific performance. Thermal tests were carried out as part of the on-ground calibration campaign at various stages of instrument integration. In this paper we describe the results and analysis of the tests on the LFI flight model (FM) performed at Thales Laboratories in Milan (Italy) during 2006, with the purpose of experimentally sampling the thermal transfer functions and consequently validating the numerical thermal model describing the dynamic response of the LFI focal plane. This model has been used extensively to assess the ability of LFI to achieve its scientific goals: its validation is therefore extremely important in the context of the Planck mission. Our analysis shows that the measured thermal properties of the instrument show a thermal dam** level better than predicted, therefore further reducing the expected systematic effect induced in the LFI maps. We then propose an explanation of the increased dam** in terms of non-ideal thermal contacts.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Cryogenic environment and performance for testing the Planck radiometers
Authors:
L. Terenzi,
M. Lapolla,
M. Laaninen,
P. Battaglia,
F. Cavaliere,
A. De Rosa,
N. Hughes,
P. Jukkala,
V. -H. Kilpiä,
G. Morgante,
M. Tomasi,
J. Varis,
M. Bersanelli,
R. C. Butler,
F. Ferrari,
C. Franceschet,
P. Leutenegger,
N. Mandolesi,
A. Mennella,
R. Silvestri,
L. Stringhetti,
J. Tuovinen,
L. Valenziano,
F. Villa
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st
The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/**st
The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Off-line radiometric analysis of Planck/LFI data
Authors:
M. Tomasi,
A. Mennella,
S. Galeotta,
S. R. Lowe,
L. Mendes,
R. Leonardi,
F. Villa,
B. Cappellini,
A. Gregorio,
P. Meinhold,
M. Sandri,
F. Cuttaia,
L. Terenzi,
M. Maris,
L. Valenziano,
M. J. Salmon,
M. Bersanelli,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
E. Franceschi,
F. Gasparo,
G. Maggio
, et al. (13 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common pla…
▽ More
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Cryogenic characterization of the Planck sorption cooler system flight model
Authors:
G. Morgante,
D. Pearson,
F. Melot,
P. Stassi,
L. Terenzi,
P. Wilson,
B. Hernandez,
L. Wade,
A. Gregorio,
M. Bersanelli,
C. Butler,
N. Mandolesi
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled by the Jet Propulsion Laboratory (JPL) for the European Space Agency (ESA) Planck mission. Each refrigerator has been designed to provide a total of ~ 1W o…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled by the Jet Propulsion Laboratory (JPL) for the European Space Agency (ESA) Planck mission. Each refrigerator has been designed to provide a total of ~ 1W of cooling power at two instrument interfaces: they directly cool the Planck Low Frequency Instrument (LFI) around 20K while providing a pre-cooling stage for a 4 K J-T mechanical refrigerator for the High Frequency Instrument (HFI). After sub-system level validation at JPL, the cryocoolers have been delivered to ESA in 2005. In this paper we present the results of the cryogenic qualification and test campaigns of the Nominal Unit on the flight model spacecraft performed at the CSL (Centre Spatial de Liege) facilities in 2008. Test results in terms of input power, cooling power, temperature, and temperature fluctuations over the flight allowable ranges for these interfaces are reported and analyzed with respect to mission requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
The linearity response of the Planck-LFI flight model receivers
Authors:
A. Mennella,
F. Villa,
L. Terenzi,
F. Cuttaia,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
O. D'Arcangelo,
E. Artal,
R. Davis,
M. Frailis,
C. Franceschet,
S. Galeotta,
A. Gregorio,
N. Hughes,
P. Jukkala,
D. Kettle,
V. -H. Kilpiä,
M. Laaninen,
P. M. Lapolla,
R. Leonardi,
P. Leutenegger,
S. Lowe,
N. Mandolesi,
M. Maris
, et al. (15 additional authors not shown)
Abstract:
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best para…
▽ More
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Noise Properties of the Planck-LFI Receivers
Authors:
P. Meinhold,
R. Leonardi,
B. Aja,
E. Artal,
P. Battaglia,
M. Bersanelli,
E. Blackhurst,
C. R. Butler,
L. P. Cuevas,
F. Cuttaia,
O. D'Arcangelo,
R. Davis,
M. L. de la Fuente,
M. Frailis,
C. Franceschet,
E. Franceschi,
T. Gaier,
S. Galeotta,
A. Gregorio,
R. Hoyland,
N. Hughes,
P. Jukkala,
D. Kettle,
M. Laaninen,
P. Leutenegger
, et al. (25 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: the Planck-LFI programme
Authors:
N. Mandolesi,
M. Bersanelli,
R. C. Butler,
E. Artal,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
M. Bartelmann,
K. Bennett,
P. Bhandari,
A. Bonaldi,
J. Borrill,
M. Bremer,
C. Burigana,
R. C. Bowman,
P. Cabella,
C. Cantalupo,
B. Cappellini,
T. Courvoisier,
G. Crone,
F. Cuttaia,
L. Danese,
O. D'Arcangelo,
R. D. Davies
, et al. (118 additional authors not shown)
Abstract:
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic…
▽ More
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
△ Less
Submitted 15 January, 2010;
originally announced January 2010.
-
The Planck Low Frequency Instrument
Authors:
N. Mandolesi,
C. Burigana,
R. C. Butler,
F. Cuttaia,
A. De Rosa,
F. Finelli,
E. Franceschi,
A. Gruppuso,
M. Malaspina,
G. Morgante,
G. Morigi,
L. Popa,
M. Sandri,
L. Stringhetti,
L. Terenzi,
L. Valenziano,
F. Villa
Abstract:
Planck is the third generation of mm-wave instruments designed for space observations of the cosmic microwave background (CMB) anisotropies within the new Cosmic Vision 2020 ESA Science Program. Planck will map the whole sky with unprecedented sensitivity, angular resolution, and frequency coverage, and it likely leads us to the final comprehension of the CMB anisotropies. The Low Frequency Inst…
▽ More
Planck is the third generation of mm-wave instruments designed for space observations of the cosmic microwave background (CMB) anisotropies within the new Cosmic Vision 2020 ESA Science Program. Planck will map the whole sky with unprecedented sensitivity, angular resolution, and frequency coverage, and it likely leads us to the final comprehension of the CMB anisotropies. The Low Frequency Instrument (LFI), operating in the 30-70 GHz range, is one of the two instruments onboard Planck satellite, sharing the focal region of a 1.5 meter off-axis dual reflector telescope together with the High Frequency Instrument (HFI) operating at 100-857 GHz. We present LFI and discuss the major instrumental systematic effects that could degrade the measurements and the solutions adopted in the design and data analysis phase in order to adequately reduce and control them.
△ Less
Submitted 15 November, 2004;
originally announced November 2004.
-
Imaging the first light: experimental challenges and future perspectives in the observation of the Cosmic Microwave Background Anisotropy
Authors:
A. Mennella,
C. Baccigalupi,
A. Balbi,
M. Bersanelli,
C. Burigana,
C. Butler,
B. Cappellini,
G. De Gasperis,
F. Hansen,
D. Maino,
N. Mandolesi,
M. Maris,
G. Morgante,
P. Natoli,
F. Pasian,
F. Perrotta,
P. Platania,
L. Valenziano,
F. Villa,
A. Zacchei
Abstract:
Measurements of the cosmic microwave background (CMB) allow high precision observation of the Last Scattering Surface at redshift $z\sim$1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy, results from many ground-based and balloon-borne experiments have showed a remarkable consistency between different results and provided quantit…
▽ More
Measurements of the cosmic microwave background (CMB) allow high precision observation of the Last Scattering Surface at redshift $z\sim$1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy, results from many ground-based and balloon-borne experiments have showed a remarkable consistency between different results and provided quantitative estimates of fundamental cosmological properties. During 2003 the team of the NASA WMAP satellite has released the first improved full-sky maps of the CMB since COBE, leading to a deeper insight into the origin and evolution of the Universe. The ESA satellite Planck, scheduled for launch in 2007, is designed to provide the ultimate measurement of the CMB temperature anisotropy over the full sky, with an accuracy that will be limited only by astrophysical foregrounds, and robust detection of polarisation anisotropy. In this paper we review the experimental challenges in high precision CMB experiments and discuss the future perspectives opened by second and third generation space missions like WMAP and Planck.
△ Less
Submitted 23 February, 2004;
originally announced February 2004.
-
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
D. Maino,
N. Mandolesi,
G. Morgante,
L. Valenziano,
F. Villa,
T. Gaier,
M. Seiffert,
S. Levin,
C. Lawrence,
P. Meinhold,
P. Lubin,
J. Tuovinen,
J. Varis,
T. Karttaavi,
N. Hughes,
P. Jukkala,
P. Sjman,
P. Kangaslahti,
N. Roddis,
D. Kettle,
F. Winder,
E. Blackhurst
, et al. (12 additional authors not shown)
Abstract:
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing te…
▽ More
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing technique (with a tunable parameter called gain modulation factor) which is effective in reducing the radiometer susceptibility to amplifier instabilities also in presence of small non-idealities in the radiometric chain components, provided that the gain modulation factor is estimated with an accuracy of the order of 0.2%. These results have been recently confirmed by experimental laboratory measurements conducted on the LFI prototype radiometers at 30, 70 and 100 GHz.
△ Less
Submitted 7 July, 2003;
originally announced July 2003.
-
Planck Low Frequency Instrument: Beam Patterns
Authors:
M. Sandri,
M. Bersanelli,
C. Burigana,
R. C. Butler,
M. Malaspina,
N. Mandolesi,
A. Mennella,
G. Morgante,
L. Terenzi,
L. Valenziano,
F. Villa
Abstract:
The Low Frequency Instrument on board the ESA Planck satellite is coupled to the Planck 1.5 meter off-axis dual reflector telescope by an array of 27 corrugated feed horns operating at 30, 44, 70, and 100 GHz. We briefly present here a detailed study of the optical interface devoted to optimize the angular resolution (10 arcmin at 100 GHz as a goal) and at the same time to minimize all the syste…
▽ More
The Low Frequency Instrument on board the ESA Planck satellite is coupled to the Planck 1.5 meter off-axis dual reflector telescope by an array of 27 corrugated feed horns operating at 30, 44, 70, and 100 GHz. We briefly present here a detailed study of the optical interface devoted to optimize the angular resolution (10 arcmin at 100 GHz as a goal) and at the same time to minimize all the systematics coming from the sidelobes of the radiation pattern. Through optical simulations, we provide shapes, locations on the sky, angular resolutions, and polarization properties of each beam.
△ Less
Submitted 8 April, 2003;
originally announced April 2003.
-
Sources Variability With Planck LFI
Authors:
L. Terenzi,
M. Bersanelli,
C. Burigana,
R. C. Butler,
G. De Zotti,
N. Mandolesi,
A. Mennella,
G. Morgante,
M. Sandri,
L. Valenziano,
F. Villa
Abstract:
Planck LFI (Low Frequency Instrument) will produce a complete survey of the sky at millimeter wavelengths. Data stream analysis will provide the possibility to reveal unexpected millimeter sources and to study their flux evolution in time at different frequencies. We describe here the main implications and discuss data analysis methods. Planck sensitivities typical for this kind of detection are…
▽ More
Planck LFI (Low Frequency Instrument) will produce a complete survey of the sky at millimeter wavelengths. Data stream analysis will provide the possibility to reveal unexpected millimeter sources and to study their flux evolution in time at different frequencies. We describe here the main implications and discuss data analysis methods. Planck sensitivities typical for this kind of detection are taken into account. We present also preliminary results of our simulation activity.
△ Less
Submitted 22 March, 2002;
originally announced March 2002.
-
The Planck Telescope
Authors:
F. Villa,
M. Bersanelli,
C. Burigana,
R. C. Butler,
N. Mandolesi,
A. Mennella,
G. Morgante,
M. Sandri,
L. Terenzi,
L. Valenziano
Abstract:
In this paper we present an overview of the Telescope designed for ESA's mission dedicated to map the Cosmic Microwave Background Anisotropies and Polarization. Two instruments, LFI and HFI, operate in an overall frequency range between 25 and 900 GHz and share the focal region of the 1.5 meter optimized telescope. The optimization techniques adopted for the optical design and the telescope char…
▽ More
In this paper we present an overview of the Telescope designed for ESA's mission dedicated to map the Cosmic Microwave Background Anisotropies and Polarization. Two instruments, LFI and HFI, operate in an overall frequency range between 25 and 900 GHz and share the focal region of the 1.5 meter optimized telescope. The optimization techniques adopted for the optical design and the telescope characteristic are reported and discussed.
△ Less
Submitted 7 December, 2001;
originally announced December 2001.
-
PLANCK: systematic effects induced by periodic fluctuations of arbitrary shape
Authors:
Aniello Mennella,
Marco Bersanelli,
Carlo Burigana,
Davide Maino,
Nazzareno Mandolesi,
Gianluca Morgante,
Giuseppe Stanghellini
Abstract:
A fundamental requirement in the new generation of high resolution Cosmic Microwave Background imaging experiments is a strict control of systematic errors that must be kept at micro-K level in the final maps. Some of these errors are of celestial origin, while others will be generated by periodic fluctuations of the satellite environment. These environment instabilities will cause fluctuations…
▽ More
A fundamental requirement in the new generation of high resolution Cosmic Microwave Background imaging experiments is a strict control of systematic errors that must be kept at micro-K level in the final maps. Some of these errors are of celestial origin, while others will be generated by periodic fluctuations of the satellite environment. These environment instabilities will cause fluctuations in the measured signal output thus generating correlated effects in the reconstructed maps. In this paper we present an analytical study of the impact of periodic signal fluctuations on the measured sky maps produced by the Planck survey. In particular we show how it is possible to estimate analytically the dam** factor of the peak-to-peak amplitude of the fluctuation at the instrument output after the projection in the final maps.
△ Less
Submitted 12 March, 2002; v1 submitted 5 November, 2001;
originally announced November 2001.
-
Analysis of thermally-induced effects in Planck Low Frequency Instrument
Authors:
A. Mennella,
M. Bersanelli,
C. Burigana,
D. Maino,
R. Ferretti,
G. Morgante,
M. Prina,
N. Mandolesi,
C. Butler,
L. Valenziano,
F. Villa
Abstract:
The Planck mission will provide full-sky maps of the Cosmic Microwave Background with unprecedented angular resolution (~ 10') and sensitivity (DT / T = 10^-6). This requires cryogenically cooled, high sensitivity detectors as well as an extremely accurate control of systematic errors, which must be kept at micro-K level. In this work we focus on systematic effects arising from thermal instabili…
▽ More
The Planck mission will provide full-sky maps of the Cosmic Microwave Background with unprecedented angular resolution (~ 10') and sensitivity (DT / T = 10^-6). This requires cryogenically cooled, high sensitivity detectors as well as an extremely accurate control of systematic errors, which must be kept at micro-K level. In this work we focus on systematic effects arising from thermal instabilities in the Low Frequency Instrument operating in the 30-100 GHz range. Our results show that it is of crucial importance to assure "in hardware" a high degree of stability. In addition, we provide an estimate of the level at which it is possible to reduce the contamination level in the observed maps by proper analysis of the Time Ordered Data.
△ Less
Submitted 11 October, 2001;
originally announced October 2001.