-
Multispin correlations and pseudo-thermalization of the transient density matrix in solid-state NMR: free induction decay and magic echo
Authors:
Steven W. Morgan,
Vadim Oganesyan,
Gregory S. Boutis
Abstract:
Quantum unitary evolution typically leads to thermalization of generic interacting many-body systems. There are very few known general methods for reversing this process, and we focus on the magic echo, a radio-frequency pulse sequence known to approximately "rewind" the time evolution of dipolar coupled homonuclear spin systems in a large magnetic field. By combining analytic, numerical, and expe…
▽ More
Quantum unitary evolution typically leads to thermalization of generic interacting many-body systems. There are very few known general methods for reversing this process, and we focus on the magic echo, a radio-frequency pulse sequence known to approximately "rewind" the time evolution of dipolar coupled homonuclear spin systems in a large magnetic field. By combining analytic, numerical, and experimental results we systematically investigate factors leading to the degradation of magic echoes, as observed in reduced revival of mean transverse magnetization. Going beyond the conventional analysis based on mean magnetization we use a phase encoding technique to measure the growth of spin correlations in the density matrix at different points in time following magic echoes of varied durations and compare the results to those obtained during a free induction decay (FID). While considerable differences are documented at short times, the long-time behavior of the density matrix appears to be remarkably universal among the types of initial states considered - simple low order multispin correlations are observed to decay exponentially at the same rate, seeding the onset of increasingly complex high order correlations. This manifestly athermal process is constrained by conservation of the second moment of the spectrum of the density matrix and proceeds indefinitely, assuming unitary dynamics.
△ Less
Submitted 16 August, 2012; v1 submitted 31 May, 2012;
originally announced May 2012.
-
Control of scroll wave turbulence using resonant perturbations
Authors:
S. W. Morgan,
I. V. Biktasheva,
V. N. Biktashev
Abstract:
Turbulence of scroll waves is a sort of spatio-temporal chaos that exists in three-dimensional excitable media. Cardiac tissue and the Belousov-Zhabotinsky reaction are examples of such media. In cardiac tissue, chaotic behaviour is believed to underlie fibrillation which, without intervention, precedes cardiac death. In this study we investigate suppression of the turbulence using stimulation o…
▽ More
Turbulence of scroll waves is a sort of spatio-temporal chaos that exists in three-dimensional excitable media. Cardiac tissue and the Belousov-Zhabotinsky reaction are examples of such media. In cardiac tissue, chaotic behaviour is believed to underlie fibrillation which, without intervention, precedes cardiac death. In this study we investigate suppression of the turbulence using stimulation of two different types, "modulation of excitability" and "extra transmembrane current". With cardiac defibrillation in mind, we used a single pulse as well as repetitive extra current with both constant and feedback controlled frequency. We show that turbulence can be terminated using either a resonant modulation of excitability or a resonant extra current. The turbulence is terminated with much higher probability using a resonant frequency perturbation than a non-resonant one. Suppression of the turbulence using a resonant frequency is up to fifty times faster than using a non-resonant frequency, in both the modulation of excitability and the extra current modes. We also demonstrate that resonant perturbation requires strength one order of magnitude lower than that of a single pulse, which is currently used in clinical practice to terminate cardiac fibrillation. Our results provide a robust method of controlling complex chaotic spatio-temporal processes. Resonant drift of spiral waves has been studied extensively in two dimensions, however, these results show for the first time that it also works in three dimensions, despite the complex nature of the scroll wave turbulence.
△ Less
Submitted 19 September, 2008; v1 submitted 13 June, 2008;
originally announced June 2008.
-
Universal Long-time Behavior of Nuclear Spin Decays in a Solid
Authors:
Steven W. Morgan,
Boris V. Fine,
Brian Saam
Abstract:
Magnetic resonance studies of nuclear spins in solids are exceptionally well suited to probe the limits of statistical physics. We report experimental results indicating that isolated macroscopic systems of interacting nuclear spins possess the following fundamental property: spin decays that start from different initial configurations quickly evolve towards the same long-time behavior. This lon…
▽ More
Magnetic resonance studies of nuclear spins in solids are exceptionally well suited to probe the limits of statistical physics. We report experimental results indicating that isolated macroscopic systems of interacting nuclear spins possess the following fundamental property: spin decays that start from different initial configurations quickly evolve towards the same long-time behavior. This long-time behavior is characterized by the shortest ballistic microscopic timescale of the system and therefore falls outside of the validity range for conventional approximations of statistical physics. We find that the nuclear free induction decay and different solid echoes in hyperpolarized solid xenon all exhibit sinusoidally modulated exponential long-time behavior characterized by identical time constants. This universality was previously predicted on the basis of analogy with resonances in classical chaotic systems.
△ Less
Submitted 13 May, 2008;
originally announced May 2008.
-
Low energy defibrillation in human cardiac tissue: a simulation study
Authors:
S. W. Morgan,
G. Plank,
I. V. Biktasheva,
V. N. Biktashev
Abstract:
We aim to assess the effectiveness of feedback controlled resonant drift pacing as a method for low energy defibrillation. Antitachycardia pacing is the only low energy defibrillation approach to have gained clinical significance, but it is still suboptimal. Low energy defibrillation would avoid adverse side effects associated with high voltage shocks and allow the application of ICD therapy whe…
▽ More
We aim to assess the effectiveness of feedback controlled resonant drift pacing as a method for low energy defibrillation. Antitachycardia pacing is the only low energy defibrillation approach to have gained clinical significance, but it is still suboptimal. Low energy defibrillation would avoid adverse side effects associated with high voltage shocks and allow the application of ICD therapy where it is not tolerated today. We present results of computer simulations of a bidomain model of cardiac tissue with human atrial ionic kinetics. Re-entry was initiated and low energy shocks were applied with the same period as the re-entry, using feedback to maintain resonance. We demonstrate that such stimulation can move the core of re-entrant patterns, in the direction depending on location of electrodes and a time delay in the feedback. Termination of re-entry is achieved with shock strength one order of magnitude weaker than in conventional single-shock defibrillation. We conclude that resonant drift pacing can terminate re-entry at a fraction of the shock strength currently used for defibrillation and can potentially work where antitachycardia pacing fails, due to the feedback mechanisms. Success depends on a number of details which these numerical simulations have uncovered. \emph{Keywords} Re-entry; Bidomain model; Resonant drift; ICD; Defibrillation; Antitachycardia pacing; Feedback.
△ Less
Submitted 25 November, 2008; v1 submitted 2 May, 2008;
originally announced May 2008.