Destructive breakdown studies of irradiated LGADs at beam tests for the ATLAS HGTD
Authors:
L. A. Beresford,
D. E. Boumediene,
L. Castillo García,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
H. El Jarrari,
A. Eshkevarvakili,
C. Grieco,
S. Grinstein,
S. Guindon,
A. Howard,
G. Kramberger,
O. Kurdysh,
R. Mazini,
M. Missio,
M. Morenas,
O. Perrin,
V. Raskina,
G. Saito,
S. Trincaz-Duvoid
Abstract:
In the past years, it has been observed at several beam test campaigns that irradiated LGAD sensors break with a typical star shaped burn mark when operated at voltages much lower than those at which they were safely operated during laboratory tests. The study presented in this paper was designed to determine the safe operating voltage that these sensors can withstand. Many irradiated sensors from…
▽ More
In the past years, it has been observed at several beam test campaigns that irradiated LGAD sensors break with a typical star shaped burn mark when operated at voltages much lower than those at which they were safely operated during laboratory tests. The study presented in this paper was designed to determine the safe operating voltage that these sensors can withstand. Many irradiated sensors from various producers were tested in two test beam facilities, DESY (Hamburg) and CERN-SPS (Geneva), as part of ATLAS High Granularity Timing Detector (HGTD) beam tests. The samples were placed in the beam and kept under bias over a long period of time in order to reach a high number of particles crossing each sensor. Both beam tests lead to a similar conclusion, that these destructive events begin to occur when the average electric field in the sensor becomes larger than 12 Volts per micrometre.
△ Less
Submitted 14 July, 2023; v1 submitted 21 June, 2023;
originally announced June 2023.
-
Performance of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector
Authors:
C. Agapopoulou,
L. A. Beresford,
D. E. Boumediene,
L. Castillo García,
S. Conforti,
C. de la Taille,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
P. Dinaucourt,
A. Falou,
V. Gautam,
D. Gong,
C. Grieco,
S. Grinstein,
S. Guindon,
A. Howard,
O. Kurdysh,
E. Kuwertz,
C. Li,
N. Makovec,
B. Markovic,
G. Martin-Chassal,
R. Mazzini,
C. Milke,
M. Morenas
, et al. (12 additional authors not shown)
Abstract:
This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad matrix and contains the analog part of the single-channel readout (preamplifier, discriminator, two TDCs and SRAM). Two preamplifier architectures (t…
▽ More
This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad matrix and contains the analog part of the single-channel readout (preamplifier, discriminator, two TDCs and SRAM). Two preamplifier architectures (transimpedance and voltage) were implemented and tested. The ASIC was characterised both alone and as a module when connected to a 5$\times$5-pad array of LGAD sensors. In calibration measurements, the ASIC operating alone was found to satisfy the technical requirements for the project, with similar performances for both preamplifier types. In particular, the jitter was found to be 15$\pm$1~ps (35$\pm$1~ps) for an injected charge of 10~fC (4~fC). A degradation in performance was observed when the ASIC was connected to the LGAD array. This is attributed to digital couplings at the entrance of the preamplifiers. When the ASIC is connected to the LGAD array, the lowest detectable charge increased from 1.5~fC to 3.4~fC. As a consequence, the jitter increased for an injected charge of 4~fC. Despite this increase, ALTIROC1 still satisfies the maximum jitter specification (below 65~ps) for the HGTD project. This coupling issue also affects the time over threshold measurements and the time-walk correction can only be performed with transimpedance preamplifiers. Beam test measurements with a pion beam at CERN were also undertaken to evaluate the performance of the module. The best time resolution obtained using only ALTIROC TDC data was 46.3$\pm$0.7~ps for a restricted time of arrival range where the coupling issue is minimized. The residual time-walk contribution is equal to 23~ps and is the dominant electronic noise contribution to the time resolution at 15~fC.
△ Less
Submitted 25 July, 2023; v1 submitted 15 June, 2023;
originally announced June 2023.
-
Study experimental time resolution limits of recent ASICs at Weeroc with different SiPMs and scintillators
Authors:
Tasneem Saleem,
Salleh Ahmad,
Jean-Baptiste Cizel,
Christophe De La Taille,
Maxime Morenas,
Vanessa Nadig,
Florent Perez,
Volkmar Schulz,
Stefan Gundacker,
Julien Fleury
Abstract:
Medical applications, such as Positron Emission Tomography (PET), and space applications, such as Light Detection and Ranging (LIDAR), are in need of highly specialized ASICs. Weeroc, in collaboration with different partners, is highly involved in develo** a new generation of front-end ASICs. In the context of a joined LIDAR project among Weeroc, CNES, and Airbus, Weeroc is working on the develo…
▽ More
Medical applications, such as Positron Emission Tomography (PET), and space applications, such as Light Detection and Ranging (LIDAR), are in need of highly specialized ASICs. Weeroc, in collaboration with different partners, is highly involved in develo** a new generation of front-end ASICs. In the context of a joined LIDAR project among Weeroc, CNES, and Airbus, Weeroc is working on the development of Liroc, an ASIC for space LIDAR application. Weeroc is also working on advancing ASICs for medical applications with Radioroc under development and intended to be used for PET applications. This study experimentally evaluates the time resolution limits of these ASICs in different configurations, with some of the most recent silicon photomultiplier (SiPM) technologies available on the market, coupled to different scintillation crystals. The best single-photon time resolution (SPTR) was achieved using FBK NUV-HD SiPMs with an FWHM of 90 ps with Liroc and 73 ps with Radioroc. Furthermore, the coincidence time resolution (CTR) of Radioroc was studied with different crystal sizes. Using a large LYSO:Ce,Ca crystal of (3 x 3 x 20 mm3) with Broadcom Near UltraViolet-Metal in Trench (NUV-MT) yields a CTR of 127 ps (FWHM). The best CTR of Radioroc was determined to 83 ps (FWHM) with Broadcom NUV-MT SiPMs coupled to LYSO:Ce,Ca (2 x 2 x 3 mm3) from Taiwan Applied Crystal (TAC).
△ Less
Submitted 5 October, 2023; v1 submitted 24 May, 2023;
originally announced May 2023.
-
A High-resolution Clock Phase Shifter Circuitry for ALTIROC
Authors:
X. Huang,
C. de La Taille,
D. Gong,
C. Liu,
T. Liu,
M. Morenas,
N. Seguin-Moreau,
J. Ye,
L. Zhang
Abstract:
A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 13…
▽ More
A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 130 nm CMOS process. The area of the phase shifter is 725 um x 248 um. The Differential Non-Linearity (DNL) and the Integral Non-Linearity (INL) are +/-0.6 LSB and +/-0.75 LSB, respectively. The jitter from -25 C to 20 C is less than 15.5 ps (RMS), including the contributions from the FPGA clock source and the PLL. The power consumption is 11.2 mW.
△ Less
Submitted 13 January, 2023;
originally announced January 2023.
-
Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip
Authors:
G. D'Amen,
W. Chen,
C. De La Taille,
G. Giacomini,
D. Marchand,
M. Morenas,
C. Munoz Camacho,
E. Rossi,
N. Seguin-Moreau,
L. Serin,
A. Tricoli,
P. -K. Wang
Abstract:
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates,…
▽ More
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. In this paper, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the HL-LHC. Signal generated by either betas from a $^{90}$Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.