First ClearMind gamma detector prototype for TOF-PET imaging
Authors:
A. Galindo-Tellez,
V. Sharyy,
C. -H. Sung,
M. Follin,
L. Cappellugola,
S. Curtoni,
M. Dupont,
C. Morel,
D. Breton,
J. Maalmi,
D. Yvon
Abstract:
The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO) crystal, which is encapsulated within a commercial Micro-Channel Plate Photomultiplier tube MAPMT253 with a bialkali photocathode directly deposited on the crystal. We…
▽ More
The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO) crystal, which is encapsulated within a commercial Micro-Channel Plate Photomultiplier tube MAPMT253 with a bialkali photocathode directly deposited on the crystal. We report the proof of concept of the directly deposited of a bialkali photocathode on a PWO crystal and its stability over time. The full calibration of the ClearMind photodetector module in the single-photoelectron regime is described. We measured a time resolution of 70 ps FWHM using a 20 ps pulsed laser. We present the performance of the prototype used in coincidence with a 3 $\times$ 3 $\times$ 3 mm$^3$ LYSO:Ca,Ce crystal readout by a SiPM. We obtained a coincidence time resolution of 350 ps FWHM, a spatial resolution of 4 to 5 mm, and a detection efficiency of 28 %, consistent with Monte Carlo simulations of the ClearMind detector module.
△ Less
Submitted 27 June, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
A high sensitivity Cherenkov detector for Prompt Gamma Timing and Time Imaging
Authors:
Maxime Jacquet,
Saba Ansari,
Marie-Laure Gallin-Martel,
Adélie André,
Yannick Boursier,
Mathieu Dupont,
Jilali Es-smimih,
Laurent Gallin-Martel,
Joël Hérault,
Christophe Hoarau,
Johan-Petter Hofverberg,
Daniel Maneval,
Christian Morel,
Jean-François Muraz,
Fabrice Salicis,
Sara Marcatili
Abstract:
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown…
▽ More
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown, through Monte Carlo simulation, that an original data reconstruction algorithm (Prompt Gamma Time Imaging) allows to combine the response of multiple detectors placed around the target. In this work we focus on the experimental feasibility of PGTI in Single Proton Regime (SPR) through the development of a multi-channel, Cherenkov-based PG detector with a targeted time resolution of 235 ps (FWHM): the TOF Imaging ARrAy (TIARA). The PG module that we developed is composed of a small PbF$_{2}$ crystal coupled to a silicon photoMultiplier to provide the time stamp of the PG. This prototype was tested with 63 MeV protons delivered from a cyclotron: a time resolution of 276 ps (FWHM) was obtained, resulting in a proton range sensitivity of 4 mm at 2$σ$ with the acquisition of only 600 PGs. A second prototype was also evaluated with 148 MeV protons delivered from a synchro-cyclotron obtaining a time resolution below 167 ps (FWHM) for the gamma detector. Moreover, using two identical PG modules, it was shown that a uniform sensitivity on the PG profiles would be achievable by combining the response of gamma detectors uniformly distributed around the target. This work provides the experimental proof-of-concept for the development of a high sensitivity detector that can be used to monitor particle therapy treatments and potentially act in real-time if the irradiation does not comply to treatment plan.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
Detailed simulation for the ClearMind prototype detection module and event reconstruction using artificial intelligence
Authors:
Chi-Hsun Sung,
Laurie Cappellugola,
Megane Follin,
Sébastien Curtoni,
Mathieu Dupont,
Christian Morel,
Aline Galindo-Tellez,
Roman Chyzh,
Dominique Breton,
Jihane Maalmi,
Dominique Yvon,
Viatcheslav Sharyy
Abstract:
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result t…
▽ More
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result together from the 511 keV gamma-ray interation into the PWO crystal. A micro-channel plate photomultiplier tube (MCP-PMT) encapsulating the PWO crystal amplifies photoelectrons generated at the photocathode, and the corresponding anode signals are collected through the transmission lines read out at both ends and digitized by a SAMPIC module. In this work, we present a realistic Geant4 simulation of the ClearMind prototype detector, including the propagation of the visible photons in the crystal, the modelling of a realistic response of the photocathode and of the PMT, and the propagation of the electrical signals over the transmission lines. The reconstruction of the gamma conversion in the detector volume is performed from the signals registered at both ends of the transmission lines. We compare the reconstruction precision of a statistical algorithm against machine learning algorithms developed using the TMVA package. We expect to reach a spatial resolution down to a few mm$^3$ (FWHM). Finally, we will discuss prospects for the ClearMind detector.
△ Less
Submitted 26 January, 2023; v1 submitted 23 September, 2022;
originally announced September 2022.
-
Characterization of a beam-tagging hodoscope for hadrontherapy monitoring
Authors:
O. Allegrini,
J. -P. Cachemiche,
C. P. C. Caplan,
B. Carlus,
X. Chen,
S. Curtoni,
D. Dauvergne,
R. Della Negra,
M. -L. Gallin-Martel,
J. Hérault,
J. M. Létang,
C. Morel,
É. Testa,
Y. Zoccarato
Abstract:
A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber…
▽ More
A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber planes. The detection efficiency with a coincidence between the two planes is close to 75 % for beam intensities up to $\sim1$ MHz. Moreover, the timing resolution is around 1.8 ns FWHM. Overall, the performances show that such a technology is viable for beam monitoring during hadrontherapy.
△ Less
Submitted 6 January, 2021;
originally announced January 2021.
-
A Time-Of-Flight-Based Reconstruction for Real-Time Prompt-Gamma Imaging in Protontherapy
Authors:
Maxime Jacquet,
Sara Marcatili,
Marie-Laure Gallin-Martel,
Jean-Luc Bouly,
Yannick Boursier,
Denis Dauvergne,
Mathieu Dupont,
Laurent Gallin-Martel,
Joël Hérault,
Jean-Michel Létang,
Daniel Manéval,
Christian Morel,
Jean-François Muraz,
Étienne Testa
Abstract:
We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam…
▽ More
We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam delivery. In this paper, two non-iterative reconstruction strategies are proposed. The first is based on the resolution of an analytical formula describing the PG vertex distribution in 3D. Here, it was resolved under a one-dimensional approximation in order to measure a potential proton range shift along the beam direction. The second is based on the calculation of the Centre-Of-Gravity (COG) of the TIARA pixel detectors counts and also provides 3D information on a possible beam displacement. The PG vertex reconstruction was evaluated in two different scenarios. A coincidence time resolution of 100 ps (rms) can be attained in single proton regime (operating a reduction of the beam current) and using an external beam monitor to provide a start trigger for the TOF measurement. Under these conditions, MC simulations have shown that a millimetric proton range shift sensitivity can be achieved at 2$σ$ with 10$^{8}$ incident protons. This level of accuracy would allow to act in real-time if the treatment does not conform to treatment plan. A worst case scenario of a 1 ns (rms) TOF resolution was also considered to demonstrate that a degraded timing information can be compensated by increasing the acquisition statistics: in this case, a 2 mm range shift would be detectable at 2$σ$ with 10$^{9}$ incident protons. The COG method has shown excellent capabilities of detecting lateral beam displacements: a 2 mm sensitivity was found at 2$σ$ with 10$^{8}$ incident protons.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
Design study of a scintronic crystal targeting tens of picoseconds time resolution for gamma ray imaging: the ClearMind detector
Authors:
D. Yvon,
V. Sharyy,
M. Follin,
J-P Bard,
D. Breton,
J. Maalmi,
C. Morel,
E. Delagnes
Abstract:
We describe the concept of a new gamma ray scintronic detector targeting a time resolution of the order of 25 ps FWHM, with millimetric volume reconstruction and high detection efficiency. Its design consists of a monolithic large PbWO4 scintillating crystal with an efficient photocathode directly deposited on it. With an index of refraction higher for the photocathode than for the crystal, this d…
▽ More
We describe the concept of a new gamma ray scintronic detector targeting a time resolution of the order of 25 ps FWHM, with millimetric volume reconstruction and high detection efficiency. Its design consists of a monolithic large PbWO4 scintillating crystal with an efficient photocathode directly deposited on it. With an index of refraction higher for the photocathode than for the crystal, this design negates the total reflection effect of optical photons at the crystal/photo-detector optical interface, and thus largely improves optical coupling between the crystal and the photodetector. This allows to detect efficiently the Cherenkov light produced by 511 keV photoelectric conversions in PbWO4, and to optimize the detector time resolution. Furthermore, the low-yield, fast scintillation light produced additionally by PbWO4 increases the detected photon statistics by a factor 10, thus fostering accurate (3 dimensional) localization of the gamma ray interaction within the crystal and providing a fair measurement of the deposited energy. This paper lists the technological challenges that have to be overcome in order to build this scintronic detector. We show that all the key technologies have now been demonstrated and present results of a preliminary Monte Carlo simulation, which include an innovative event reconstruction algorithm to support the claimed performances of the detector.
△ Less
Submitted 26 June, 2020;
originally announced June 2020.
-
Experience with wavefront sensor and deformable mirror interfaces for wide-field adaptive optics systems
Authors:
A. G. Basden,
D. Atkinson,
N. A. Bharmal,
U. Bitenc,
M. Brangier,
T. Buey,
T. Butterley,
D. Cano,
F. Chemla,
P. Clark,
M. Cohen,
J. -M. Conan,
F. J. de Cos,
C. Dickson,
N. A. Dipper,
C. N. Dunlop,
P. Feautrier,
T. Fusco,
J. L. Gach,
E. Gendron,
D. Geng,
S. J. Goodsell,
D. Gratadour,
A. H. Greenaway,
A. Guesalaga
, et al. (34 additional authors not shown)
Abstract:
Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs).
Here, we report on our experience integrating cameras and DMs with the real-time c…
▽ More
Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs).
Here, we report on our experience integrating cameras and DMs with the real-time control systems of two wide-field AO systems. These are CANARY, which has been operating on-sky since 2010, and DRAGON, which is a laboratory adaptive optics real-time demonstrator instrument. We detail the issues and difficulties that arose, along with the solutions we developed. We also provide recommendations for consideration when develo** future wide-field AO systems.
△ Less
Submitted 24 March, 2016;
originally announced March 2016.
-
Development of a PCI Express Based Readout Electronics for the XPAD3 X-Ray Photon Counting Image
Authors:
A. Dawiec,
B. Dinkespiler,
P. Breugnon,
K. Arnaud,
P. -Y. Duval,
S. Godiot,
S. Hustache,
K. Medjoubi,
J. -F. Berar,
N. Boudet,
C. Morel,
F. Bompard
Abstract:
XPAD3 is a large surface X-ray photon counting imager with high count rates, large counter dynamics and very fast data readout. Data are readout in parallel by a PCI Express interface using DMA transfer. The readout frame rate of the complete detector comprising 0.5 MPixels amounts to 500 images per second without dead-time.
XPAD3 is a large surface X-ray photon counting imager with high count rates, large counter dynamics and very fast data readout. Data are readout in parallel by a PCI Express interface using DMA transfer. The readout frame rate of the complete detector comprising 0.5 MPixels amounts to 500 images per second without dead-time.
△ Less
Submitted 21 March, 2011;
originally announced March 2011.
-
GATE : a simulation toolkit for PET and SPECT
Authors:
S. Jan,
G. Santin,
D. Strul,
S. Staelens,
K. Assie,
D. Autret,
S. Avner,
R. Barbier,
M. Bardies,
P. M. Bloomfield,
D. Brasse,
V. Breton,
P. Bruyndonckx,
I. Buvat,
A. F. Chatziioannou,
Y. Choi,
Y. H. Chung,
C. Comtat,
D. Donnarieix,
L. Ferrer,
S. J. Glick,
C. J. Groiselle,
D. Guez,
P. -F. Honore,
S. Kerhoas-Cavata
, et al. (28 additional authors not shown)
Abstract:
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted…
▽ More
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.epfl.ch/GATE/.
△ Less
Submitted 24 August, 2004;
originally announced August 2004.
-
A calibration of iota Pegasi system
Authors:
P. Morel,
Ch. Morel,
J. Provost,
G. Berthomieu
Abstract:
Recent observations provide determinations of individual masses, chemical composition and metallicity of the components of the spectroscopic and interferometric binary ιPeg (Boden et al. 1998). Using updated physics, to calibrate the system, we have computed using the stellar evolutionary code CESAM, evolutionary sequences of stellar models with the masses of ιPeg A
1.326 Msol and iota Peg B 0.…
▽ More
Recent observations provide determinations of individual masses, chemical composition and metallicity of the components of the spectroscopic and interferometric binary ιPeg (Boden et al. 1998). Using updated physics, to calibrate the system, we have computed using the stellar evolutionary code CESAM, evolutionary sequences of stellar models with the masses of ιPeg A
1.326 Msol and iota Peg B 0.819 Msol (Boden et al. loc.cit) and with different values of the mixing-length parameter α, the helium Y and the heavy element Z initial mass fraction with the constraint of the observed metallicity. Adopting effective temperatures and luminosities, as derived from observations with the bolometric corrections, and the empirical scale of temperatures of Alonso et al. (1995, 1996), we find α_A=1.46, α_B=1.36, Y=0.278, Z=0.017. The evolution time, including pre-main sequence, is found within 40 My < t_ev < 0.5Gy. The calibrated models of ιPeg. A and B are non homogeneous zero age main sequence stars with the evolutionary time t_ev=56 My. Due to the large uncertainties of their determinations, the values derived for the mixing-length parameters are smaller than the solar one but however marginally compatible with it. Our results ought to be improved as soon as a more accurate value of the magnitude difference in the V filter will be available. Detailed spectroscopic analysis for both components looks practicable, so it is urgently needed.
△ Less
Submitted 15 December, 1999;
originally announced December 1999.