Skip to main content

Showing 1–10 of 10 results for author: Morel, C

.
  1. arXiv:2312.13169  [pdf, other

    physics.ins-det physics.med-ph

    First ClearMind gamma detector prototype for TOF-PET imaging

    Authors: A. Galindo-Tellez, V. Sharyy, C. -H. Sung, M. Follin, L. Cappellugola, S. Curtoni, M. Dupont, C. Morel, D. Breton, J. Maalmi, D. Yvon

    Abstract: The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO) crystal, which is encapsulated within a commercial Micro-Channel Plate Photomultiplier tube MAPMT253 with a bialkali photocathode directly deposited on the crystal. We… ▽ More

    Submitted 27 June, 2024; v1 submitted 20 December, 2023; originally announced December 2023.

    Comments: 23 pages, 24 figures

  2. arXiv:2309.03612  [pdf, other

    physics.med-ph physics.ins-det

    A high sensitivity Cherenkov detector for Prompt Gamma Timing and Time Imaging

    Authors: Maxime Jacquet, Saba Ansari, Marie-Laure Gallin-Martel, Adélie André, Yannick Boursier, Mathieu Dupont, Jilali Es-smimih, Laurent Gallin-Martel, Joël Hérault, Christophe Hoarau, Johan-Petter Hofverberg, Daniel Maneval, Christian Morel, Jean-François Muraz, Fabrice Salicis, Sara Marcatili

    Abstract: We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown… ▽ More

    Submitted 7 September, 2023; originally announced September 2023.

    Journal ref: Sci Rep 13, 3609 (2023)

  3. Detailed simulation for the ClearMind prototype detection module and event reconstruction using artificial intelligence

    Authors: Chi-Hsun Sung, Laurie Cappellugola, Megane Follin, Sébastien Curtoni, Mathieu Dupont, Christian Morel, Aline Galindo-Tellez, Roman Chyzh, Dominique Breton, Jihane Maalmi, Dominique Yvon, Viatcheslav Sharyy

    Abstract: The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result t… ▽ More

    Submitted 26 January, 2023; v1 submitted 23 September, 2022; originally announced September 2022.

  4. arXiv:2101.02079  [pdf, other

    physics.ins-det physics.med-ph

    Characterization of a beam-tagging hodoscope for hadrontherapy monitoring

    Authors: O. Allegrini, J. -P. Cachemiche, C. P. C. Caplan, B. Carlus, X. Chen, S. Curtoni, D. Dauvergne, R. Della Negra, M. -L. Gallin-Martel, J. Hérault, J. M. Létang, C. Morel, É. Testa, Y. Zoccarato

    Abstract: A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber… ▽ More

    Submitted 6 January, 2021; originally announced January 2021.

    Comments: 17 pages, 18 figures

  5. A Time-Of-Flight-Based Reconstruction for Real-Time Prompt-Gamma Imaging in Protontherapy

    Authors: Maxime Jacquet, Sara Marcatili, Marie-Laure Gallin-Martel, Jean-Luc Bouly, Yannick Boursier, Denis Dauvergne, Mathieu Dupont, Laurent Gallin-Martel, Joël Hérault, Jean-Michel Létang, Daniel Manéval, Christian Morel, Jean-François Muraz, Étienne Testa

    Abstract: We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam… ▽ More

    Submitted 16 December, 2020; originally announced December 2020.

  6. arXiv:2006.14855  [pdf

    physics.ins-det physics.med-ph

    Design study of a scintronic crystal targeting tens of picoseconds time resolution for gamma ray imaging: the ClearMind detector

    Authors: D. Yvon, V. Sharyy, M. Follin, J-P Bard, D. Breton, J. Maalmi, C. Morel, E. Delagnes

    Abstract: We describe the concept of a new gamma ray scintronic detector targeting a time resolution of the order of 25 ps FWHM, with millimetric volume reconstruction and high detection efficiency. Its design consists of a monolithic large PbWO4 scintillating crystal with an efficient photocathode directly deposited on it. With an index of refraction higher for the photocathode than for the crystal, this d… ▽ More

    Submitted 26 June, 2020; originally announced June 2020.

    Comments: Accepted in Journal of Instrumentation : JINST_054P_0320

  7. arXiv:1603.07527  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Experience with wavefront sensor and deformable mirror interfaces for wide-field adaptive optics systems

    Authors: A. G. Basden, D. Atkinson, N. A. Bharmal, U. Bitenc, M. Brangier, T. Buey, T. Butterley, D. Cano, F. Chemla, P. Clark, M. Cohen, J. -M. Conan, F. J. de Cos, C. Dickson, N. A. Dipper, C. N. Dunlop, P. Feautrier, T. Fusco, J. L. Gach, E. Gendron, D. Geng, S. J. Goodsell, D. Gratadour, A. H. Greenaway, A. Guesalaga , et al. (34 additional authors not shown)

    Abstract: Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs). Here, we report on our experience integrating cameras and DMs with the real-time c… ▽ More

    Submitted 24 March, 2016; originally announced March 2016.

    Comments: Accepted for publication in MNRAS

  8. arXiv:1103.3926  [pdf

    physics.ins-det

    Development of a PCI Express Based Readout Electronics for the XPAD3 X-Ray Photon Counting Image

    Authors: A. Dawiec, B. Dinkespiler, P. Breugnon, K. Arnaud, P. -Y. Duval, S. Godiot, S. Hustache, K. Medjoubi, J. -F. Berar, N. Boudet, C. Morel, F. Bompard

    Abstract: XPAD3 is a large surface X-ray photon counting imager with high count rates, large counter dynamics and very fast data readout. Data are readout in parallel by a PCI Express interface using DMA transfer. The readout frame rate of the complete detector comprising 0.5 MPixels amounts to 500 images per second without dead-time.

    Submitted 21 March, 2011; originally announced March 2011.

    Comments: 17th Real-Time Conference on Real-Time Computer Applications in Nuclear, Particle and Plasma Physics, Lisbonne : Portugal (2010)

  9. arXiv:physics/0408109  [pdf, ps, other

    physics.med-ph physics.bio-ph

    GATE : a simulation toolkit for PET and SPECT

    Authors: S. Jan, G. Santin, D. Strul, S. Staelens, K. Assie, D. Autret, S. Avner, R. Barbier, M. Bardies, P. M. Bloomfield, D. Brasse, V. Breton, P. Bruyndonckx, I. Buvat, A. F. Chatziioannou, Y. Choi, Y. H. Chung, C. Comtat, D. Donnarieix, L. Ferrer, S. J. Glick, C. J. Groiselle, D. Guez, P. -F. Honore, S. Kerhoas-Cavata , et al. (28 additional authors not shown)

    Abstract: Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted… ▽ More

    Submitted 24 August, 2004; originally announced August 2004.

    Journal ref: Phys.Med.Biol.49:4543-4561,2004

  10. arXiv:astro-ph/9912307  [pdf, ps, other

    astro-ph

    A calibration of iota Pegasi system

    Authors: P. Morel, Ch. Morel, J. Provost, G. Berthomieu

    Abstract: Recent observations provide determinations of individual masses, chemical composition and metallicity of the components of the spectroscopic and interferometric binary ιPeg (Boden et al. 1998). Using updated physics, to calibrate the system, we have computed using the stellar evolutionary code CESAM, evolutionary sequences of stellar models with the masses of ιPeg A 1.326 Msol and iota Peg B 0.… ▽ More

    Submitted 15 December, 1999; originally announced December 1999.

    Comments: 10 pages, plain tex, plus 3 .ps figures, accepted by A&A

    Journal ref: Astron.Astrophys.354:636-644,2000