-
Nano-modulated electron beams via electron diffraction and emittance exchange for coherent x-ray generation
Authors:
Emilio A. Nanni,
William S. Graves,
David E. Moncton
Abstract:
We present a new method for generation of relativistic electron beams with current modulation on the nanometer scale and below. The current modulation is produced by diffracting relativistic electrons in single crystal Si, accelerating the diffracted beam and imaging the crystal structure, then transferring the image into the temporal dimension via emittance exchange. The modulation period can be…
▽ More
We present a new method for generation of relativistic electron beams with current modulation on the nanometer scale and below. The current modulation is produced by diffracting relativistic electrons in single crystal Si, accelerating the diffracted beam and imaging the crystal structure, then transferring the image into the temporal dimension via emittance exchange. The modulation period can be tuned by adjusting electron optics after diffraction. This tunable longitudinal modulation can have a period as short as a few angstroms, enabling production of coherent hard x-rays from a source based on inverse Compton scattering with total accelerator length of approximately ten meters. Electron beam simulations from cathode emission through diffraction, acceleration and image formation with variable magnification are presented along with estimates of the coherent x-ray output properties.
△ Less
Submitted 21 September, 2017; v1 submitted 23 June, 2015;
originally announced June 2015.
-
Compact x-ray source based on burst-mode inverse Compton scattering at 100 kHz
Authors:
W. S. Graves,
J. Bessuille,
P. Brown,
S. Carbajo,
V. Dolgashev,
K. -H. Hong,
E. Ihloff,
B. Khaykovich,
H. Lin,
K. Murari,
E. A. Nanni,
G. Resta,
S. Tantawi,
L. E. Zapata,
F. X. Kärtner,
D. E. Moncton
Abstract:
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and RF photoinjector powered by a single ultrastable RF transmitter at x-…
▽ More
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and RF photoinjector powered by a single ultrastable RF transmitter at x-band RF frequency. The high efficiency permits operation at repetition rates up to 1 kHz, which is further boosted to 100 kHz by operating with trains of 100 bunches of 100 pC charge, each separated by 5 ns. The entire accelerator is approximately 1 meter long and produces hard x-rays tunable over a wide range of photon energies. The colliding laser is a Yb:YAG solid-state amplifier producing 1030 nm, 100 mJ pulses at the same 1 kHz repetition rate as the accelerator. The laser pulse is frequency-doubled and stored for many passes in a ringdown cavity to match the linac pulse structure. At a photon energy of 12.4 keV, the predicted x-ray flux is $5 \times 10^{11}$ photons/second in a 5% bandwidth and the brilliance is $2 \times 10^{12}\mathrm{photons/(sec\ mm^2\ mrad^2\ 0.1\%)}$ in pulses with RMS pulse length of 490 fs. The nominal electron beam parameters are 18 MeV kinetic energy, 10 microamp average current, 0.5 microsecond macropulse length, resulting in average electron beam power of 180 W. Optimization of the x-ray output is presented along with design of the accelerator, laser, and x-ray optic components that are specific to the particular characteristics of the Compton scattered x-ray pulses.
△ Less
Submitted 9 October, 2014; v1 submitted 24 September, 2014;
originally announced September 2014.
-
Demonstration of a novel focusing small-angle neutron scattering instrument equipped with axisymmetric mirrors
Authors:
Dazhi Liu,
Boris Khaykovich,
Mikhail V. Gubarev,
J Lee Robertson,
Lowell Crow,
Brian D. Ramsey,
David E. Moncton
Abstract:
Small-angle neutron scattering (SANS) is the most significant neutron technique in terms of impact on science and engineering. However, the basic concept of SANS facilities has not changed since the technique's inception about 40 years ago, as all SANS instruments, save a few, are still designed as pinhole cameras. Here we demonstrate a novel concept for a SANS instrument, based on axisymmetric fo…
▽ More
Small-angle neutron scattering (SANS) is the most significant neutron technique in terms of impact on science and engineering. However, the basic concept of SANS facilities has not changed since the technique's inception about 40 years ago, as all SANS instruments, save a few, are still designed as pinhole cameras. Here we demonstrate a novel concept for a SANS instrument, based on axisymmetric focusing mirrors. We build and test a small prototype, which shows a performance comparable to that of conventional large SANS facilities. By using a detector with 50-micron pixels, we build the most compact SANS instrument in the world. This work, together with the recent demonstration that such mirrors could increase the signal rate at least 50-fold, while improving resolution, paves the way to novel SANS instruments, thus affecting a broad community of scientists and engineers.
△ Less
Submitted 4 October, 2013;
originally announced October 2013.
-
Demonstration of Achromatic Cold-Neutron Microscope Utilizing Axisymmetric Focusing Mirrors
Authors:
D. Liu,
D. Hussey,
M. V. Gubarev,
B. D. Ramsey,
D. Jacobson,
M. Arif,
D. E. Moncton,
B. Khaykovich
Abstract:
An achromatic cold-neutron microscope with magnification 4 is demonstrated. The image-forming optics is composed of nested coaxial mirrors of full figures of revolution, so-called Wolter optics. The spatial resolution, field of view, and depth of focus are measured and found consistent with ray-tracing simulations. Methods of increasing the resolution and magnification are discussed, as well as th…
▽ More
An achromatic cold-neutron microscope with magnification 4 is demonstrated. The image-forming optics is composed of nested coaxial mirrors of full figures of revolution, so-called Wolter optics. The spatial resolution, field of view, and depth of focus are measured and found consistent with ray-tracing simulations. Methods of increasing the resolution and magnification are discussed, as well as the scientific case for the neutron microscope. In contrast to traditional pinhole-camera neutron imaging, the resolution of the microscope is determined by the mirrors rather than by the collimation of the beam, leading to possible dramatic improvements in the signal rate and resolution.
△ Less
Submitted 22 April, 2013;
originally announced April 2013.
-
Axisymmetric Grazing-Incidence Focusing Optics for Small-Angle Neutron Scattering
Authors:
Dazhi Liu,
Mikhail V. Gubarev,
Giacomo Resta,
Brian D. Ramsey,
David E. Moncton,
Boris Khaykovich
Abstract:
We propose and design novel axisymmetric focusing mirrors, known as Wolter optics, for small-angle neutron scattering instruments. Ray-tracing simulations show that using the mirrors can result in more than an order-of-magnitude increase in the neutron flux reaching detectors, while decreasing the minimum wave vector transfer. Such mirrors are made of Ni using a mature technology. They can be coat…
▽ More
We propose and design novel axisymmetric focusing mirrors, known as Wolter optics, for small-angle neutron scattering instruments. Ray-tracing simulations show that using the mirrors can result in more than an order-of-magnitude increase in the neutron flux reaching detectors, while decreasing the minimum wave vector transfer. Such mirrors are made of Ni using a mature technology. They can be coated with neutron supermirror multilayers, and multiple mirrors can be nested to improve their flux-collection ability. Thus, these mirrors offer simple and flexible means of significantly improving existing and future SANS instruments. In addition, short SANS instruments might become possible, especially at compact neutron sources, when high-resolution detectors are combined with Wolter optics.
△ Less
Submitted 2 May, 2012;
originally announced May 2012.
-
From x-ray telescopes to neutron scattering: using axisymmetric mirrors to focus a neutron beam
Authors:
B. Khaykovich,
M. V. Gubarev,
Y. Bagdasarova,
B. D. Ramsey,
D. E. Moncton
Abstract:
We demonstrate neutron beam focusing by axisymmetric mirror systems based on a pair of mirrors consisting of a confocal ellipsoid and hyperboloid. Such a system, known as a Wolter mirror configuration, is commonly used in x-ray telescopes. The axisymmetric Wolter geometry allows nesting of several mirror pairs to increase collection efficiency. We have implemented a system containing four nested N…
▽ More
We demonstrate neutron beam focusing by axisymmetric mirror systems based on a pair of mirrors consisting of a confocal ellipsoid and hyperboloid. Such a system, known as a Wolter mirror configuration, is commonly used in x-ray telescopes. The axisymmetric Wolter geometry allows nesting of several mirror pairs to increase collection efficiency. We have implemented a system containing four nested Ni mirror pairs, which was tested by focusing a polychromatic neutron beam at the MIT Reactor. In addition, we have carried out extensive ray-tracing simulations of the mirrors and their performance in different situations. The major advantages of the Wolter mirrors are nesting for large angular collection, and aberration-free performance. We discuss how these advantages can be utilized to benefit various neutron scattering methods, such as imaging, SANS, and time-of-flight spectroscopy.
△ Less
Submitted 13 April, 2012;
originally announced April 2012.
-
Probing electronic order via coupling to low energy phonons in superconducting Bi$_2$Sr$_{2-x}$La$_x$CuO$_{6+δ}$
Authors:
C. J. Bonnoit,
D. R. Gardner,
R. Chisnell,
A. H. Said,
Y. Okada,
T. Kondo,
T. Takeuchi,
H. Ikuta,
D. E. Moncton,
Y. S. Lee
Abstract:
We report high-resolution inelastic x-ray scattering measurements of the acoustic phonons in the single-layer cuprate $Bi_{2}Sr_{2-x)La_{x}CuO_{6+δ}$. These measurements reveal anomalous broadening of the longitudinal acoustic phonon near the (1/4,1/4,0) wavevector. The observed wavevector and its do** dependence indicate the coupling of the phonons to an underlying electronic density wave state…
▽ More
We report high-resolution inelastic x-ray scattering measurements of the acoustic phonons in the single-layer cuprate $Bi_{2}Sr_{2-x)La_{x}CuO_{6+δ}$. These measurements reveal anomalous broadening of the longitudinal acoustic phonon near the (1/4,1/4,0) wavevector. The observed wavevector and its do** dependence indicate the coupling of the phonons to an underlying electronic density wave state. In addition, a comparison of the scattered intensities for x-ray energy-gain and x-ray energy-loss indicates that both time-reversal and inversion symmetries are broken in the material. Upon cooling, the effects of symmetry breaking are enhanced in the pseudogap state.
△ Less
Submitted 22 February, 2012;
originally announced February 2012.
-
Intense Super-radiant X-rays from a Compact Source using a Nanocathode Array and Emittance Exchange
Authors:
W. S. Graves,
F. X. Kaertner,
D. E. Moncton,
P. Piot
Abstract:
A novel method of producing intense short wavelength radiation from relativistic electrons is described. The electrons are periodically bunched at the wavelength of interest enabling in-phase super-radiant emission that is orders of magnitude more intense than that of unbunched electrons. The periodic bunching is achieved in steps beginning with an array of beamlets emitted from a nanoengineered f…
▽ More
A novel method of producing intense short wavelength radiation from relativistic electrons is described. The electrons are periodically bunched at the wavelength of interest enabling in-phase super-radiant emission that is orders of magnitude more intense than that of unbunched electrons. The periodic bunching is achieved in steps beginning with an array of beamlets emitted from a nanoengineered field emission array. The beamlets are then manipulated and converted to a longitudinal density modulation via a transverse to longitudinal emittance exchange. Periodic bunching at short wavelength is shown to be possible, and the partially coherent x-ray properties produced by Inverse Compton scattering from an intense laser are estimated for an example at 13 nm wavelength using a 1.5 MeV electron beam.
△ Less
Submitted 23 May, 2012; v1 submitted 1 February, 2012;
originally announced February 2012.
-
X-ray Scattering Study of the spin-Peierls transition and soft phonon behavior in TiOCl
Authors:
E. T. Abel,
K. Matan,
F. C. Chou,
E. D. Isaacs,
D. E. Moncton,
H. Sinn,
A. Alatas,
Y. S. Lee
Abstract:
We have studied the S=1/2 quasi-one-dimensional antiferromagnet TiOCl using single crystal x-ray diffraction and inelastic x-ray scattering techniques. The Ti ions form staggered spin chains which dimerize below Tc1 = 66 K and have an incommensurate lattice distortion between Tc1 and Tc2 = 92 K. Based on our measurements of the intensities, wave vectors, and harmonics of the incommensurate super…
▽ More
We have studied the S=1/2 quasi-one-dimensional antiferromagnet TiOCl using single crystal x-ray diffraction and inelastic x-ray scattering techniques. The Ti ions form staggered spin chains which dimerize below Tc1 = 66 K and have an incommensurate lattice distortion between Tc1 and Tc2 = 92 K. Based on our measurements of the intensities, wave vectors, and harmonics of the incommensurate superlattice peaks, we construct a model for the incommensurate modulation. The results are in good agreement with a soliton lattice model, though some quantitative discrepancies exist near Tc2. The behavior of the phonons has been studied using inelastic x-ray scattering with ~2 meV energy resolution. For the first time, a zone boundary phonon which softens at the spin-Peierls temperature Tsp has been observed. Our results show reasonably good quantitative agreement with the Cross-Fisher theory for the phonon dynamics at wave vectors near the zone boundary and temperatures near Tsp. However, not all aspects of the data can be described, such as the strong overdam** of the soft mode above Tsp. Overall, our results show that TiOCl is a good realization of a spin-Peierls system, where the phonon softening allows us to identify the transition temperature as Tsp=Tc2=92 K
△ Less
Submitted 6 August, 2007;
originally announced August 2007.