Injection Feedback for a Storage Ring
Authors:
A. Moutardier,
N. Delerue,
C. Bruni,
I. Chaikovska,
S. Chancé,
E. E. Ergenlik,
V. Kubytskyi,
H. Monard
Abstract:
We report on an injection feedback scheme for the ThomX storage ring project. ThomX is a 50-MeV-electron accelerator prototype which will use Compton backscattering in a storage ring to generate a high flux of hard X-rays. Given the slow beam dam** (in the ring), the injection must be performed with high accuracy to avoid large betatron oscillations. A homemade analytic code is used to compute t…
▽ More
We report on an injection feedback scheme for the ThomX storage ring project. ThomX is a 50-MeV-electron accelerator prototype which will use Compton backscattering in a storage ring to generate a high flux of hard X-rays. Given the slow beam dam** (in the ring), the injection must be performed with high accuracy to avoid large betatron oscillations. A homemade analytic code is used to compute the corrections that need to be applied before the beam injection to achieve a beam position accuracy of a few hundred micrometers in the first beam position monitors (BPMs). In order to do so the code needs the information provided by the ring's diagnostic devices. The iterative feedback system has been tested using MadX simulations. Our simulations show that a performance that matches the BPMs' accuracy can be achieved in less than 50 iterations in all cases. Details of this feedback algorithm, its efficiency and the simulations are discussed.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
Loss maps along the ThomX transfer line and the ring first turn
Authors:
A. Moutardier,
C. Bruni,
I. Chaikovska,
S. Chancé,
N. Delerue,
E. E. Ergenlik,
V. Kubytskyi,
H. Monard
Abstract:
We report on studies of the loss maps for particles travelling from the end of the ThomX's linac along the transfer line to the end of the ring first turn in preparation of the machine commissioning. ThomX is a 50-MeV-electron accelerator prototype which will use Compton backscattering to generate a high flux of hard X-rays. The accelerator tracking code MadX is used to simulate electrons' propaga…
▽ More
We report on studies of the loss maps for particles travelling from the end of the ThomX's linac along the transfer line to the end of the ring first turn in preparation of the machine commissioning. ThomX is a 50-MeV-electron accelerator prototype which will use Compton backscattering to generate a high flux of hard X-rays. The accelerator tracking code MadX is used to simulate electrons' propagation and compute losses. These maps may be projected at any localisation along the bunch path or plotted along the bunch path. This information is particularly relevant at the locations of the monitoring devices (screens, position monitors,...) where loss predictions will be compared with measurements.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
LEETECH facility as a flexible source of low energy electrons
Authors:
D. Attie,
S. Barsuk,
O. Bezshyyko,
L. Burmistrov,
A. Chaus,
P. Colas,
O. Fedorchuk,
L. Golinka-Bezshyyko,
I. Kadenko,
V. Krylov,
V. Kubytskyi,
R. Lopez,
H. Monard,
V. Rodin,
M. Titov,
D. Tomassini,
A. Variola
Abstract:
A new versatile facility LEETECH for detector R&D, tests and calibration is designed and constructed. It uses electrons produced by the photoinjector PHIL at LAL, Orsay and provides a powerful tool for wide range R&D studies of different detector concepts delivering "mono-chromatic" samples of low energy electrons with adjustable energy and intensity. Among other innovative instrumentation techniq…
▽ More
A new versatile facility LEETECH for detector R&D, tests and calibration is designed and constructed. It uses electrons produced by the photoinjector PHIL at LAL, Orsay and provides a powerful tool for wide range R&D studies of different detector concepts delivering "mono-chromatic" samples of low energy electrons with adjustable energy and intensity. Among other innovative instrumentation techniques, LEETECH will be used for testing various gaseous tracking detectors and studying new Micromegas/InGrid concept which has very promising characteristics of spatial resolution and can be a good candidate for particle tracking and identification. In this paper the importance and expected characteristics of such facility based on detailed simulation studies are addressed.
△ Less
Submitted 17 January, 2016;
originally announced January 2016.
-
PHIL photoinjector test line
Authors:
M. Alves,
C. Arnault,
D. Auguste,
J. L. Babigeon,
F. Blot,
J. Brossard,
C. Bruni,
S. Cavalier,
J. N. Cayla,
V. Chaumat,
J. Collin,
M. Dehamme,
M. Demarest,
J. P. Dugal,
M. Elkhaldi,
I. Falleau,
A. Gonnin,
M. Jore,
E. Jules,
B. Leluan,
P. Lepercq,
F. Letellier,
E. Mandag,
J. C. Marrucho,
B. Mercier
, et al. (8 additional authors not shown)
Abstract:
LAL is now equiped with its own platform for photoinjectors tests and Research and Developement, named PHIL (PHotoInjectors at LAL). This facility has two main purposes: push the limits of the photoinjectors performances working on both the design and the associated technology and provide a low energy (MeV) short pulses (ps) electron beam for the interested users. Another very important goal of th…
▽ More
LAL is now equiped with its own platform for photoinjectors tests and Research and Developement, named PHIL (PHotoInjectors at LAL). This facility has two main purposes: push the limits of the photoinjectors performances working on both the design and the associated technology and provide a low energy (MeV) short pulses (ps) electron beam for the interested users. Another very important goal of this machine will be to provide an opportunity to form accelerator physics students, working in a high technology environment. To achieve this goal a test line was realised equipped with an RF source, magnets and beam diagnostics. In this article we will desrcibe the PHIL beamline and its characteristics together with the description of the first two photoinjector realised in LAL and tested: the ALPHAX and the PHIN RF Guns.
△ Less
Submitted 24 September, 2012;
originally announced September 2012.