Ion-induced effects in GEM & GEM/MHSP gaseous photomultipliers for the UV and the visible spectral range
Abstract: We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of part… ▽ More
Submitted 24 February, 2005; originally announced February 2005.
Comments: 6 pages, 8 figures
Journal ref: Nucl.Instrum.Meth.A553:46-52,2005
-
Thick GEM-like hole multipliers: properties and possible applications
Abstract: The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of about 104, 106, and 105 were reached at respective pressures of 1, 10 Torr isobutane and 740 Torr Ar/5%CH4, with pulse rise-times in the few nanosecond scale. T… ▽ More
Submitted 28 April, 2004; v1 submitted 26 April, 2004; originally announced April 2004.
Comments: Contribution to the 2004 Vienna Conference on Instrumentation
Journal ref: Nucl.Instrum.Meth. A535 (2004) 303-308
-
Recent Investigations of Cascaded GEM and MHSP detectors
Abstract: We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast radiation imaging detectors, that have single-charge sensitivity. The issue of ion-backflow and ion-induced secondary effects is discussed in some detail, prese… ▽ More
Submitted 24 November, 2003; originally announced November 2003.
Comments: 8 pages, IEEE Nuclear Science Symposium
Journal ref: IEEE Trans.Nucl.Sci. 51 (2004) 2097-2103
-
Construction and Performance of a Micro-Pattern Stereo Detector with Two Gas Electron Multipliers
Abstract: The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same technology as the GEM foils. The strips of each layer cross at an effective crossing angle of 6.7 degrees and have a 406 um pitch. The performance of the detecto… ▽ More
Submitted 4 October, 2001; originally announced October 2001.
Comments: 21 pages, 17 figures
Report number: IEKP-KA/2001-20
Journal ref: Nucl.Instrum.Meth. A485 (2002) 477-489