-
Observation of the radiative decay of the ${}^{229}\mathrm{Th}$ nuclear clock isomer
Authors:
Sandro Kraemer,
Janni Moens,
Michail Athanasakis-Kaklamanakis,
Silvia Bara,
Kjeld Beeks,
Premaditya Chhetri,
Katerina Chrysalidis,
Arno Claessens,
Thomas E. Cocolios,
João M. Correia,
Hilde De Witte,
Rafael Ferrer,
Sarina Geldhof,
Reinhard Heinke,
Niyusha Hosseini,
Mark Huyse,
Ulli Köster,
Yuri Kudryavtsev,
Mustapha Laatiaoui,
Razvan Lica,
Goele Magchiels,
Vladimir Manea,
Clement Merckling,
Lino M. C. Pereira,
Sebastian Raeder
, et al. (10 additional authors not shown)
Abstract:
The nucleus of the radioisotope thorium-229 (${}^{229}$Th) features an isomer with an exceptionally low excitation energy that enables direct laser manipulation of nuclear states. For this reason, it is a leading candidate for use in next-generation optical clocks. This nuclear clock will be a unique tool, amongst others, for tests of fundamental physics. While first indirect experimental evidence…
▽ More
The nucleus of the radioisotope thorium-229 (${}^{229}$Th) features an isomer with an exceptionally low excitation energy that enables direct laser manipulation of nuclear states. For this reason, it is a leading candidate for use in next-generation optical clocks. This nuclear clock will be a unique tool, amongst others, for tests of fundamental physics. While first indirect experimental evidence for the existence of such an extraordinary nuclear state is significantly older, the proof of existence has been delivered only recently by observing the isomer's electron conversion decay and its hyperfine structure in a laser spectroscopy study, revealing information on the isomer's excitation energy, nuclear spin and electromagnetic moments. Further studies reported the electron conversion lifetime and refined the isomer's energy. In spite of recent progress, the isomer's radiative decay, a key ingredient for the development of a nuclear clock, remained unobserved.
In this Letter, we report the detection of the radiative decay of this low-energy isomer in thorium-229 (${}^{229\mathrm{m}}$Th). By performing vacuum-ultraviolet spectroscopy of ${}^{229\mathrm{m}}$Th incorporated into large-bandgap CaF${}_2$ and MgF${}_2$ crystals at the ISOLDE facility at CERN, the photon vacuum wavelength of the isomer's decay is measured as 148.71(42) nm, corresponding to an excitation energy of 8.338(24) eV. This value is in agreement with recent measurements, and decreases the uncertainty by a factor of seven. The half-life of ${}^{229\mathrm{m}}$Th embedded in MgF${}_2$ is determined to be 670(102) s. The observation of the radiative decay in a large-bandgap crystal has important consequences for the design of a future nuclear clock and the improved uncertainty of the energy eases the search for direct laser excitation of the atomic nucleus.
△ Less
Submitted 21 September, 2022;
originally announced September 2022.
-
Magnesium-vacancy optical centers in diamond
Authors:
Emilio Corte,
Greta Andrini,
Elena Nieto Hernández,
Vanna Pugliese,
Ângelo Costa,
Goele Magchiels,
Janni Moens,
Shandirai Malven Tunhuma,
Renan Villarreal,
Lino M. C. Pereira,
André Vantomme,
João Guilherme Correia,
Ettore Bernardi,
Paolo Traina,
Ivo Pietro Degiovanni,
Ekaterina Moreva,
Marco Genovese,
Sviatoslav Ditalia Tchernij,
Paolo Olivero,
Ulrich Wahl,
Jacopo Forneris
Abstract:
We provide the first systematic characterization of the structural and photoluminescence properties of optically active defect centers fabricated upon implantation of 30-100 keV Mg+ ions in artificial diamond. The structural configurations of Mg-related defects were studied by the emission channeling technique for 27Mg implantations performed both at room-temperature and 800 °C, which allowed the…
▽ More
We provide the first systematic characterization of the structural and photoluminescence properties of optically active defect centers fabricated upon implantation of 30-100 keV Mg+ ions in artificial diamond. The structural configurations of Mg-related defects were studied by the emission channeling technique for 27Mg implantations performed both at room-temperature and 800 °C, which allowed the identification of a major fraction of Mg atoms (~30-42%) in sites which are compatible with the split-vacancy structure of the MgV complex. A smaller fraction of Mg atoms (~13-17%) was found on substitutional sites. The photoluminescence emission was investigated both at the ensemble and individual defect level in a temperature range comprised between 5 K and 300 K, offering a detailed picture of the MgV-related emission properties and revealing the occurrence of previously unreported spectral features. The optical excitability of the MgV center was also studied as a function of the optical excitation wavelength enabling to identify the optimal conditions for photostable and intense emission. The results are discussed in the context of the preliminary experimental data and the theoretical models available in the literature, with appealing perspectives for the utilization of the tunable properties of the MgV center for quantum information processing applications.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
An alternative approach to populate and study the $^{229}$Th nuclear clock isomer
Authors:
M. Verlinde,
S. Kraemer,
J. Moens,
K. Chrysaldis,
J. G. Correia,
S. Cottenier,
H. De Witte,
D. V. Fedorov,
V. N Fedosseev,
R. Ferrer,
L. M. Fraile,
S. Geldhof,
C. A. Granados,
M. Laatiaoui,
T. A. L. Lima,
P-C Lin,
V. Manea,
B. A. Marsh,
I. Moore,
L. M. C. Pereira,
S. Raeder,
P. Van den Bergh,
P. Van Duppen,
A. Vantomme,
E. Verstraelen
, et al. (2 additional authors not shown)
Abstract:
A new approach to observe the radiative decay of the $^{229}$Th nuclear isomer, and to determine its energy and radiative lifetime, is presented. Situated at a uniquely low excitation energy, this nuclear state might be a key ingredient for the development of a nuclear clock, a nuclear laser and the search for time variations of the fundamental constants. The isomer's $γ$ decay towards the ground…
▽ More
A new approach to observe the radiative decay of the $^{229}$Th nuclear isomer, and to determine its energy and radiative lifetime, is presented. Situated at a uniquely low excitation energy, this nuclear state might be a key ingredient for the development of a nuclear clock, a nuclear laser and the search for time variations of the fundamental constants. The isomer's $γ$ decay towards the ground state will be studied with a high-resolution VUV spectrometer after its production by the $β$ decay of $^{229}$Ac. The novel production method presents a number of advantages asserting its competitive nature with respect to the commonly used $^{233}$U $α$-decay recoil source. In this paper, a feasibility analysis of this new concept, and an experimental investigation of its key ingredients, using a pure $^{229}$Ac ion beam produced at the ISOLDE radioactive beam facility, is reported.
△ Less
Submitted 23 April, 2019;
originally announced April 2019.
-
Initial results of finger imaging using Photoacoustic Computed Tomography
Authors:
Peter van Es,
Samir K. Biswas,
Hein J. Bernelot Moens,
Wiendelt Steenbergen,
Srirang Manohar
Abstract:
We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $μ$m and 1.5 mm in various orientations and…
▽ More
We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $μ$m and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential markers for disease activity.
△ Less
Submitted 20 June, 2014;
originally announced June 2014.