-
First Light Results from the Hermes Spectrograph at the AAT
Authors:
Andrew Sheinis,
Borja Anguiano,
Martin Asplund,
Carlos Bacigalupo,
Sam Barden,
Michael Birchall,
Joss Bland-Hawthorn,
Jurek Brzeski,
Russell Cannon,
Daniela Carollo,
Scott Case,
Andrew Casey,
Vladimir Churilov,
Couch Warrick,
Robert Dean,
Gayandhi De Silva,
Valentina D'Orazi,
Ly Duong,
Tony Farrell,
Kristin Fiegert,
Kenneth Freeman,
Frost Gabriella,
Luke Gers,
Michael Goodwin,
Doug Gray
, et al. (38 additional authors not shown)
Abstract:
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a facility-class optical spectrograph for the Anglo-Australian Telescope (AAT). It is designed primarily for Galactic Archaeology, the first major attempt to create a detailed understanding of galaxy formation and evolution by studying the history of our own galaxy, the Milky Way. The goal of the GALAH survey is to reconstru…
▽ More
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a facility-class optical spectrograph for the Anglo-Australian Telescope (AAT). It is designed primarily for Galactic Archaeology, the first major attempt to create a detailed understanding of galaxy formation and evolution by studying the history of our own galaxy, the Milky Way. The goal of the GALAH survey is to reconstruct the mass assembly history of the Milky Way through a detailed chemical abundance study of one million stars. The spectrograph is based at the AAT and is fed by the existing 2dF robotic fiber positioning system. The spectrograph uses volume phase holographic gratings to achieve a spectral resolving power of 28,000 in standard mode and also provides a high-resolution mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey requires an SNR greater than 100 for a star brightness of V ?= 14 in an exposure time of one hour. The total spectral coverage of the four channels is about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within the 2-degree field of view. HERMES has been commissioned over three runs, during bright time in October, November, and December 2013, in parallel with the beginning of the GALAH pilot survey, which started in November 2013. We present the first-light results from the commissioning run and the beginning of the GALAH survey, including performance results such as throughput and resolution, as well as instrument reliability.
△ Less
Submitted 31 August, 2015;
originally announced September 2015.
-
Starbugs: all-singing, all-dancing fibre positioning robots
Authors:
James Gilbert,
Michael Goodwin,
Jeroen Heijmans,
Rolf Muller,
Stan Miziarski,
Jurek Brzeski,
Lew Waller,
Will Saunders,
Alex Bennet,
Julia Tims
Abstract:
Starbugs are miniature piezoelectric 'walking' robots with the ability to simultaneously position many optical fibres across a telescope's focal plane. Their simple design incorporates two piezoceramic tubes to form a pair of concentric 'legs' capable of taking individual steps of a few microns, yet with the capacity to move a payload several millimetres per second. The Australian Astronomical Obs…
▽ More
Starbugs are miniature piezoelectric 'walking' robots with the ability to simultaneously position many optical fibres across a telescope's focal plane. Their simple design incorporates two piezoceramic tubes to form a pair of concentric 'legs' capable of taking individual steps of a few microns, yet with the capacity to move a payload several millimetres per second. The Australian Astronomical Observatory has developed this technology to enable fast and accurate field reconfigurations without the inherent limitations of more traditional positioning techniques, such as the 'pick and place' robotic arm. We report on our recent successes in demonstrating Starbug technology, driven principally by R&D efforts for the planned MANIFEST (many instrument fibre-system) facility for the Giant Magellan Telescope. Significant performance gains have resulted from improvements to the Starbug system, including i) the use of a vacuum to attach Starbugs to the underside of a transparent field plate, ii) optimisation of the control electronics, iii) a simplified mechanical design with high sensitivity piezo actuators, and iv) the construction of a dedicated laboratory 'test rig'. A method of reliably rotating Starbugs in steps of several arcminutes has also been devised, which integrates with the pre-existing x-y movement directions and offers greater flexibility while positioning. We present measured performance data from a prototype system of 10 Starbugs under full (closed-loop control), at field plate angles of 0-90 degrees.
△ Less
Submitted 28 November, 2013;
originally announced November 2013.
-
CYCLOPS2: the fibre image slicer upgrade for the UCLES high resolution spectrograph
Authors:
Anthony Horton,
C. G. Tinney,
Scott Case,
Tony Farrell,
Luke Gers,
Damien Jones,
Jon Lawrence,
Stan Miziarski,
Nick Staszak,
David Orr,
Minh Vuong,
Lew Waller,
Ross Zhelem
Abstract:
CYCLOPS2 is an upgrade for the UCLES high resolution spectrograph on the Anglo-Australian Telescope, scheduled for commissioning in semester 2012A. By replacing the 5 mirror Coudé train with a Cassegrain mounted fibre-based image slicer CYCLOPS2 simultaneously provides improved throughput, reduced aperture losses and increased spectral resolution. Sixteen optical fibres collect light from a 5.0 ar…
▽ More
CYCLOPS2 is an upgrade for the UCLES high resolution spectrograph on the Anglo-Australian Telescope, scheduled for commissioning in semester 2012A. By replacing the 5 mirror Coudé train with a Cassegrain mounted fibre-based image slicer CYCLOPS2 simultaneously provides improved throughput, reduced aperture losses and increased spectral resolution. Sixteen optical fibres collect light from a 5.0 arcsecond^2 area of sky and reformat it into the equivalent of a 0.6 arcsecond wide slit, delivering a spectral resolution of R = 70000 and up to twice as much flux as the standard 1 arcsecond slit of the Coudé train. CYCLOPS2 also adds support for simultaneous ThAr wavelength calibration via a dedicated fibre. CYCLOPS2 consists of three main components, the fore-optics unit, fibre bundle and slit unit. The fore optics unit incorporates magnification optics and a lenslet array and is designed to mount to the CURE Cassegrain instrument interface, which provides acquisition, guiding and calibration facilities. The fibre bundle transports the light from the Cassegrain focus to the UCLES spectrograph at Coudé and also includes a fibre mode scrambler. The slit unit consists of the fibre slit and relay optics to project an image of the slit onto the entrance aperture of the UCLES spectrograph. CYCLOPS2 builds on experience with the first generation CYCLOPS fibre system, which we also describe in this paper. We present the science case for an image slicing fibre feed for echelle spectroscopy and describe the design of CYCLOPS and CYCLOPS2.
△ Less
Submitted 3 January, 2013;
originally announced January 2013.
-
GNOSIS: the first instrument to use fibre Bragg gratings for OH suppression
Authors:
Christopher Q. Trinh,
Simon C. Ellis,
Joss Bland-Hawthorn,
Jon S. Lawrence,
Anthony J. Horton,
Sergio G. Leon-Saval,
Keith Shortridge,
Julia Bryant,
Scott Case,
Matthew Colless,
Warick Couch,
Kenneth Freeman,
Hans-Gerd Loehmannsroeben,
Luke Gers,
Karl Glazebrook,
Roger Haynes,
Steve Lee,
John O'Byrne,
Stan Miziarski,
Martin M. Roth,
Brian Schmidt,
Christopher G. Tinney,
Jessica Zheng
Abstract:
GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS was commissioned at the 3.9-meter Anglo-Australian Telescope with the IRIS2 spectrograph to demonstrate the potential of OH suppression fibres, but may be potentially…
▽ More
GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS was commissioned at the 3.9-meter Anglo-Australian Telescope with the IRIS2 spectrograph to demonstrate the potential of OH suppression fibres, but may be potentially used with any telescope and spectrograph combination. Unlike previous atmospheric suppression techniques GNOSIS suppresses the lines before dispersion and in a manner that depends purely on wavelength. We present the instrument design and report the results of laboratory and on-sky tests from commissioning. While these tests demonstrated high throughput and excellent suppression of the skylines by the OH suppression fibres, surprisingly GNOSIS produced no significant reduction in the interline background and the sensitivity of GNOSIS and IRIS2 is about the same as IRIS2. It is unclear whether the lack of reduction in the interline background is due to physical sources or systematic errors as the observations are detector noise-dominated. OH suppression fibres could potentially impact ground-based astronomy at the level of adaptive optics or greater. However, until a clear reduction in the interline background and the corresponding increasing in sensitivity is demonstrated optimized OH suppression fibres paired with a fibre-fed spectrograph will at least provide a real benefits at low resolving powers.
△ Less
Submitted 11 April, 2013; v1 submitted 5 December, 2012;
originally announced December 2012.
-
First Science with SAMI: A Serendipitously Discovered Galactic Wind in ESO 185-G031
Authors:
Lisa M. R. Fogarty,
Joss Bland-Hawthorn,
Scott M. Croom,
Andrew W. Green,
Julia J. Bryant,
Jon S. Lawrence,
Samuel Richards,
James T. Allen,
Amanda E. Bauer,
Michael N. Birchall,
Sarah Brough,
Matthew Colless,
Simon C. Ellis,
Tony Farrell,
Michael Goodwin,
Ron Heald,
Andrew M. Hopkins,
Anthony Horton,
D. Heath Jones,
Steve Lee,
Geraint Lewis,
Ángel R. López-Sánchez,
Stan Miziarski,
Holly Trowland,
Sergio G. Leon-Saval
, et al. (5 additional authors not shown)
Abstract:
We present the first scientific results from the Sydney-AAO Multi-Object IFS (SAMI) at the Anglo-Australian Telescope. This unique instrument deploys 13 fused fibre bundles (hexabundles) across a one-degree field of view allowing simultaneous spatially-resolved spectroscopy of 13 galaxies. During the first SAMI commissioning run, targeting a single galaxy field, one object (ESO 185-G031) was found…
▽ More
We present the first scientific results from the Sydney-AAO Multi-Object IFS (SAMI) at the Anglo-Australian Telescope. This unique instrument deploys 13 fused fibre bundles (hexabundles) across a one-degree field of view allowing simultaneous spatially-resolved spectroscopy of 13 galaxies. During the first SAMI commissioning run, targeting a single galaxy field, one object (ESO 185-G031) was found to have extended minor axis emission with ionisation and kinematic properties consistent with a large-scale galactic wind. The importance of this result is two-fold: (i) fibre bundle spectrographs are able to identify low-surface brightness emission arising from extranuclear activity; (ii) such activity may be more common than presently assumed because conventional multi-object spectrographs use single-aperture fibres and spectra from these are nearly always dominated by nuclear emission. These early results demonstrate the extraordinary potential of multi-object hexabundle spectroscopy in future galaxy surveys.
△ Less
Submitted 1 November, 2012;
originally announced November 2012.
-
'MOHAWK' : a 4000-fiber positioner for DESpec
Authors:
Will Saunders,
Greg Smith,
James Gilbert,
Rolf Muller,
Michael Goodwin,
Nick Staszak,
Jurek Brzeski,
Stan Miziarski,
Matthew Colless
Abstract:
We present a concept for a 4000-fibre positioner for DESpec, based on the Echidna 'tilting spine' technology. The DESpec focal plane is 450mm across and curved, and the required pitch is ~6.75mm. The size, number of fibers and curvature are all comparable with various concept studies for similar instruments already undertaken at the AAO, but present new challenges in combination. A simple, low-cos…
▽ More
We present a concept for a 4000-fibre positioner for DESpec, based on the Echidna 'tilting spine' technology. The DESpec focal plane is 450mm across and curved, and the required pitch is ~6.75mm. The size, number of fibers and curvature are all comparable with various concept studies for similar instruments already undertaken at the AAO, but present new challenges in combination. A simple, low-cost, and highly modular design is presented, consisting of identical modules populated by identical spines. No show-stop** issues in accommodating either the curvature or the smaller pitch have been identified, and the actuators consist largely of off-the-shelf components. The actuators have been prototyped at AAO, and allow reconfiguration times of ~15s to reach position errors 7 microns or less. Straightforward designs for metrology, acquisition, and guiding are also proposed. The throughput losses of the entire positioner system are estimated to be ~15%, of which 6.3% is attributable to the tilting-spine technology.
△ Less
Submitted 31 July, 2012; v1 submitted 30 July, 2012;
originally announced July 2012.
-
Suppression of the near-infrared OH night sky lines with fibre Bragg gratings - first results
Authors:
S. C. Ellis,
J. Bland-Hawthorn,
J. Lawrence,
A. J. Horton,
C. Trinh,
S. G. Leon-Saval,
K. Shortridge,
J. Bryant,
S. Case,
M. Colless,
W. Couch,
K. Freeman,
L. Gers,
K. Glazebrook,
R. Haynes,
S. Lee,
H. -G. Loehmannsroeben,
J. O. Byrne,
S. Miziarski,
M. Roth,
B. Schmidt,
C. G. Tinney,
J. Zheng
Abstract:
The background noise between 1 and 1.8 microns in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between 1.47 - 1.7 microns by a factor of ~1000 with a resolving power of ~10,000. We present the first results from the commissioning of GNOSIS using the IRIS2 spectrograph…
▽ More
The background noise between 1 and 1.8 microns in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between 1.47 - 1.7 microns by a factor of ~1000 with a resolving power of ~10,000. We present the first results from the commissioning of GNOSIS using the IRIS2 spectrograph at the AAT. The combined throughput of the GNOSIS fore-optics, grating unit and relay optics is ~36 per cent, but this could be improved to ~46 per cent with a more optimal design. We measure strong suppression of the OH lines, confirming that OH suppression with fibre Bragg gratings will be a powerful technology for low resolution spectroscopy. The integrated OH suppressed background between 1.5 and 1.7 microns is reduced by a factor of 9 compared to a control spectrum using the same system without suppression. The potential of low resolution OH suppressed spectroscopy is illustrated with example observations.
The GNOSIS background is dominated by detector dark current below 1.67 microns and by thermal emission above 1.67 microns. After subtracting these we detect an unidentified residual interline component of ~ 860 +/ 210 ph/s/m^2/micron/arcsec^2. This component is equally bright in the suppressed and control spectra. We have investigated the possible source of the interline component, but were unable to discriminate between a possible instrumental artifact and intrinsic atmospheric emission. Resolving the source of this emission is crucial for the design of fully optimised OH suppression spectrographs. The next generation OH suppression spectrograph will be focussed on resolving the source of the interline component, taking advantage of better optimisation for a FBG feed. We quantify the necessary improvements for an optimal OH suppressing fibre spectrograph design.
△ Less
Submitted 27 June, 2012;
originally announced June 2012.
-
The Sydney-AAO Multi-object Integral field spectrograph (SAMI)
Authors:
Scott M. Croom,
Jon S. Lawrence,
Joss Bland-Hawthorn,
Julia J. Bryant,
Lisa Fogarty,
Samuel Richards,
Michael Goodwin,
Tony Farrell,
Stan Miziarski,
Ron Heald,
D. Heath Jones,
Steve Lee,
Matthew Colless,
Sarah Brough,
Andrew M. Hopkins,
Amanda E. Bauer,
Michael N. Birchall,
Simon Ellis,
Anthony Horton,
Sergio Leon-Saval,
Geraint Lewis,
A. R. Lopez-Sanchez,
Seong-Sik Min,
Christopher Trinh,
Holly Trowland
Abstract:
We demonstrate a novel technology that combines the power of the multi-object spectrograph with the spatial multiplex advantage of an integral field spectrograph (IFS). The Sydney-AAO Multi-object IFS (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) that allows 13 imaging fibre bundles ("hexabundles") to be deployed over a 1-degree diameter field of view. Each hexabu…
▽ More
We demonstrate a novel technology that combines the power of the multi-object spectrograph with the spatial multiplex advantage of an integral field spectrograph (IFS). The Sydney-AAO Multi-object IFS (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) that allows 13 imaging fibre bundles ("hexabundles") to be deployed over a 1-degree diameter field of view. Each hexabundle comprises 61 lightly-fused multimode fibres with reduced cladding and yields a 75 percent filling factor. Each fibre core diameter subtends 1.6 arcseconds on the sky and each hexabundle has a field of view of 15 arcseconds diameter. The fibres are fed to the flexible AAOmega double-beam spectrograph, which can be used at a range of spectral resolutions (R=lambda/delta(lambda) ~ 1700-13000) over the optical spectrum (3700-9500A). We present the first spectroscopic results obtained with SAMI for a sample of galaxies at z~0.05. We discuss the prospects of implementing hexabundles at a much higher multiplex over wider fields of view in order to carry out spatially--resolved spectroscopic surveys of 10^4 to 10^5 galaxies.
△ Less
Submitted 14 December, 2011;
originally announced December 2011.