Skip to main content

Showing 1–5 of 5 results for author: Miyahara, R

.
  1. Tracking accuracy evaluation of electromagnetic sensor-based colonoscope tracking method

    Authors: Masahiro Oda, Hiroaki Kondo, Takayuki Kitasaka, Kazuhiro Furukawa, Ryoji Miyahara, Yoshiki Hirooka, Hidemi Goto, Nassir Navab, Kensaku Mori

    Abstract: This paper reports a detailed evaluation results of a colonoscope tracking method. A colonoscope tracking method utilizing electromagnetic sensors and a CT volume has been proposed. Tracking accuracy of this method was evaluated by using a colon phantom. In the previously proposed paper, tracking errors were measured only at six points on the colon phantom for the accuracy evaluation. The point nu… ▽ More

    Submitted 14 January, 2022; originally announced January 2022.

    Comments: Accepted paper as an oral presentation at the Second International Workshop on Computer-Assisted and Robotic Endoscopy (CARE) 2015, Held in Conjunction with MICCAI 2015

    Journal ref: Computer-Assisted and Robotic Endoscopy, LNCS 9515, pp.101-108, 2015

  2. arXiv:2201.05331  [pdf, ps, other

    eess.IV cs.CV cs.GR

    Semi-automated Virtual Unfolded View Generation Method of Stomach from CT Volumes

    Authors: Masahiro Oda, Tomoaki Suito, Yuichiro Hayashi, Takayuki Kitasaka, Kazuhiro Furukawa, Ryoji Miyahara, Yoshiki Hirooka, Hidemi Goto, Gen Iinuma, Kazunari Misawa, Shigeru Nawano, Kensaku Mori

    Abstract: CT image-based diagnosis of the stomach is developed as a new way of diagnostic method. A virtual unfolded (VU) view is suitable for displaying its wall. In this paper, we propose a semi-automated method for generating VU views of the stomach. Our method requires minimum manual operations. The determination of the unfolding forces and the termination of the unfolding process are automated. The unf… ▽ More

    Submitted 14 January, 2022; originally announced January 2022.

    Comments: Accepted paper as a poster presentation at MICCAI 2013 (International Conference on Medical Image Computing and Computer-Assisted Intervention), Nagoya, Japan

    Journal ref: Published in Proceedings of MICCAI 2013, LNCS 8149, pp.332-339, 2013

  3. Colon Shape Estimation Method for Colonoscope Tracking using Recurrent Neural Networks

    Authors: Masahiro Oda, Holger R. Roth, Takayuki Kitasaka, Kazuhiro Furukawa, Ryoji Miyahara, Yoshiki Hirooka, Hidemi Goto, Nassir Navab, Kensaku Mori

    Abstract: We propose an estimation method using a recurrent neural network (RNN) of the colon's shape where deformation was occurred by a colonoscope insertion. Colonoscope tracking or a navigation system that navigates physician to polyp positions is needed to reduce such complications as colon perforation. Previous tracking methods caused large tracking errors at the transverse and sigmoid colons because… ▽ More

    Submitted 20 April, 2020; originally announced April 2020.

    Comments: Accepted paper as a poster presentation at MICCAI 2018 (International Conference on Medical Image Computing and Computer-Assisted Intervention), Granada, Spain

    Journal ref: Published in Proceedings of MICCAI 2018, LNCS 11073, pp 176-184

  4. Colonoscope tracking method based on shape estimation network

    Authors: Masahiro Oda, Holger R. Roth, Takayuki Kitasaka, Kazuhiro Furukawa, Ryoji Miyahara, Yoshiki Hirooka, Nassir Navab, Kensaku Mori

    Abstract: This paper presents a colonoscope tracking method utilizing a colon shape estimation method. CT colonography is used as a less-invasive colon diagnosis method. If colonic polyps or early-stage cancers are found, they are removed in a colonoscopic examination. In the colonoscopic examination, understanding where the colonoscope running in the colon is difficult. A colonoscope navigation system is n… ▽ More

    Submitted 20 April, 2020; originally announced April 2020.

    Comments: Accepted paper as an oral presentation at SPIE Medical Imaging 2019, San Diego, CA, USA

    Journal ref: Proceedings of SPIE Medical Imaging 2019: Image-Guided Procedures, Robotic Interventions, and Modeling, Vol.10951, 109510Q

  5. Machine learning-based colon deformation estimation method for colonoscope tracking

    Authors: Masahiro Oda, Takayuki Kitasaka, Kazuhiro Furukawa, Ryoji Miyahara, Yoshiki Hirooka, Hidemi Goto, Nassir Navab, Kensaku Mori

    Abstract: This paper presents a colon deformation estimation method, which can be used to estimate colon deformations during colonoscope insertions. Colonoscope tracking or navigation system that navigates a physician to polyp positions during a colonoscope insertion is required to reduce complications such as colon perforation. A previous colonoscope tracking method obtains a colonoscope position in the co… ▽ More

    Submitted 8 June, 2018; originally announced June 2018.

    Comments: Accepted paper for oral presentation at SPIE Medical Imaging 2018, Houston, TX, USA

    Report number: Published in Proceedings of SPIE 10576, Medical Imaging 2018: Image-Guided Procedures, Robotic Interventions, and Modeling, 1057619

    Journal ref: SPIE Medical Imaging 2018: Image-Guided Procedures, Robotic Interventions, and Modeling