Towards clinical translation of deep-learning based classification of DSA image sequences for stroke treatment
Authors:
Timo Baumgärtner,
Benjamin J. Mittmann,
Till Malzacher,
Johannes Roßkopf,
Michael Braun,
Bernd Schmitz,
Alfred M. Franz
Abstract:
In the event of stroke, a catheter-guided procedure (thrombectomy) is used to remove blood clots. Feasibility of machine learning based automatic classifications for thrombus detection on digital substraction angiography (DSA) sequences has been demonstrated. It was however not used live in the clinic, yet. We present an open-source tool for automatic thrombus classification and test it on three s…
▽ More
In the event of stroke, a catheter-guided procedure (thrombectomy) is used to remove blood clots. Feasibility of machine learning based automatic classifications for thrombus detection on digital substraction angiography (DSA) sequences has been demonstrated. It was however not used live in the clinic, yet. We present an open-source tool for automatic thrombus classification and test it on three selected clinical cases regarding functionality and classification runtime. With our trained model all large vessel occlusions in the M1 segment were correctly classified. One small remaining M3 thrombus was not detected. Runtime was in the range from 1 to 10 seconds depending on the used hardware. We conclude that our open-source software tool enables clinical staff to classify DSA sequences in (close to) realtime and can be used for further studies in clinics.
△ Less
Submitted 23 May, 2023;
originally announced June 2023.
-
An open-source tool for automated planning of overlap** ablation zones for percutaneous renal tumor treatment
Authors:
A. M. Franz,
B. J. Mittmann,
J. Roeser,
B. Schmidberger,
M. Meinke,
P. L. Pereira,
H. U. Kauczor,
G. M. Richter,
C. M. Sommer
Abstract:
Percutaneous thermal ablation is a minimally-invasive treatment option for renal cancer. To treat larger tumours, multiple overlap** ablations zones are required. Arrangements with a low number of ablation zones but coverage of the whole tumour volume are challenging to find for physicians. In this work, an open-source software tool with a new planning approach based on the automatic selection f…
▽ More
Percutaneous thermal ablation is a minimally-invasive treatment option for renal cancer. To treat larger tumours, multiple overlap** ablations zones are required. Arrangements with a low number of ablation zones but coverage of the whole tumour volume are challenging to find for physicians. In this work, an open-source software tool with a new planning approach based on the automatic selection from a large number of randomized geometrical arrangements is presented. Two uncertainty parameters are introduced to account for tissue shrinking and tolerance of non-ablated tumour volume. For seven clinical renal T1a, T1b and T2a tumours, ablation plans were proposed by the software. All proposals are comparable to manual plans of an experienced physician with regard to the number of required ablation zones.
△ Less
Submitted 19 December, 2019;
originally announced December 2019.
-
Navigated interventions in the head and neck area: standardized assessment of a new handy field generator
Authors:
Benjamin J. Mittmann,
Alexander Seitel,
Lena Maier-Hein,
Alfred M. Franz
Abstract:
Electromagnetic (EM) tracking enables localization of surgical instruments within the magnetic field emitted by an EM field generator (FG). Usually, the larger a FG is, the larger its tracking volume is. However, the company NDI (Northern Digital Inc., Waterloo, ON, Canada) recently introduced the Planar 10-11 FG, which combines a compact construction (97mm x 112mm x 31mm) with a relatively large,…
▽ More
Electromagnetic (EM) tracking enables localization of surgical instruments within the magnetic field emitted by an EM field generator (FG). Usually, the larger a FG is, the larger its tracking volume is. However, the company NDI (Northern Digital Inc., Waterloo, ON, Canada) recently introduced the Planar 10-11 FG, which combines a compact construction (97mm x 112mm x 31mm) with a relatively large, cylindrical tracking volume (diameter: 340mm, height: 340mm). Using the standardized assessment protocol of Hummel et al., the FG was tested with regard to its tracking accuracy and to its robustness with respect to external sources of disturbance. The mean positional error (5cm distance metric according to Hummel protocol) was 0.59mm, with a mean jitter of 0.26mm in the standard setup. The mean orientational error was found to be 0.10°. The highest positional error (4.82mm) due to metallic sources of disturbance was caused by the steel SST 303. In contrast, steel SST 416 caused the lowest positional error (0.10mm). Overall, the Planar 10-11 FG tends to achieve better tracking accuracy results compared to other NDI FGs. Due to its compact construction and portability, the FG could contribute to increased clinical use of EM tracking systems.
△ Less
Submitted 24 March, 2019;
originally announced March 2019.