-
A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector
Authors:
CAST Collaboration,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas-Cuendis,
S. Aune,
J. Baier,
K. Barth,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
F. Christensen,
C. Cogollos,
T. Dafni,
M. Davenport,
T. A. Decker,
K. Desch,
D. Díez-Ibáñez,
B. Döbrich,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. Galán,
J. A. García
, et al. (40 additional authors not shown)
Abstract:
Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the p…
▽ More
Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the previous exposure time. The detector was operated with a xenon-based gas mixture for part of the new run, providing technical insights for future detector configurations in IAXO. No counts are detected in the 95\% signal-encircling region during the new run, while one is expected. The new data improve the axion-photon coupling limit to 5.7$\times 10^{-11}\,$GeV$^{-1}$ at 95\% C.L., the most restrictive experimental limit to date.
△ Less
Submitted 24 June, 2024;
originally announced June 2024.
-
The daily modulations and broadband strategy in axion searches. An application with CAST-CAPP detector
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (38 additional authors not shown)
Abstract:
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities…
▽ More
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities $Ω_{\rm dark}\sim Ω_{\rm visible}$. In this framework, the population of galactic axions with mass $ 10^{-6} {\rm eV}\lesssim m_a\lesssim 10^{-3}{\rm eV}$ and velocity $\langle v_a\rangle\sim 10^{-3} c$ will be accompanied by axions with typical velocities $\langle v_a\rangle\sim 0.6 c$ emitted by AQNs. Furthermore, in this framework, it has also been argued that the AQN-induced axion daily modulation (in contrast with the conventional WIMP paradigm) could be as large as $(10-20)\%$, which represents the main motivation for the present investigation. We argue that the daily modulations along with the broadband detection strategy can be very useful tools for the discovery of such relativistic axions. The data from the CAST-CAPP detector have been used following such arguments. Unfortunately, due to the dependence of the amplifier chain on temperature-dependent gain drifts and other factors, we could not conclusively show the presence or absence of a dark sector-originated daily modulation. However, this proof of principle analysis procedure can serve as a reference for future studies.
△ Less
Submitted 9 May, 2024;
originally announced May 2024.
-
Using Micromegas detectors for direct dark matter searches: challenges and perspectives
Authors:
K. Altenmueller,
. Antolin,
D. Calvet,
F. R. Candon,
J. Castel,
S. Cebrian,
C. Cogollos,
T. Dafni,
D. Diez Ibanez,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
H. Gomez,
Y. Gu,
A. Ezquerro,
I. G Irastorza,
G. Luzon,
C. Margalejo,
H. Mirallas,
L. Obis,
A. Ortiz de Solorzano,
T. Papaevangelou,
O. Perez,
E. Picatoste,
J. Porron
, et al. (5 additional authors not shown)
Abstract:
Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provide precious features,such as topological information, allowing for event directionality and powerful s…
▽ More
Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provide precious features,such as topological information, allowing for event directionality and powerful signal-background discrimination. The Micromegas technology of the microbulk type is particularly suited to low-background applications and is being exploited by detectors for CAST and IAXO (solar axions) and TREX-DM (low-mass WIMPs) experiments. Challenges for the future include reducing intrinsic background levels, reaching lower energy detection levels, and technical issues such as robustness of detector, new design choices, novel gas mixtures and operation points, scaling up to larger detector sizes, handling large readout granularity, etc. We report on the status and prospects of the development ongoing in the context of IAXO and TREX-DM experiments, pointing to promising perspectives for the use of Micromegas detectors in directdark matter searches
△ Less
Submitted 15 April, 2024;
originally announced April 2024.
-
Background discrimination with a Micromegas detector prototype and veto system for BabyIAXO
Authors:
K. Altenmüller,
J. F. Castel,
S. Cebrián,
T. Dafni,
D. Díez-Ibañez,
A. Ezquerro,
E. Ferrer-Ribas,
J. Galan,
J. Galindo,
J. A. García,
A. Giganon,
C. Goblin,
I. G. Irastorza,
C. Loiseau,
G. Luzón,
X. F. Navick,
C. Margalejo,
H. Mirallas,
L. Obis,
A. Ortiz de Solórzano,
T. Papaevangelou,
O. Pérez,
A. Quintana,
J. Ruz,
J. K. Vogel
Abstract:
In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The go…
▽ More
In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The goal of the measurement was to study techniques for background discrimination. In addition to common techniques we used a multi-layer veto system designed to tag cosmogenic neutron background. Over an effective time of 52 days, a background level of $8.6 \times 10^{-7}\,\text{counts keV}^{-1}\,\text{cm}^{-2} \, \text{s}^{-1}$ was reached in a laboratory at above ground level. This is the lowest background level achieved at surface level. In this paper we present the experimental setup, show simulations of the neutron-induced background, and demonstrate the process to identify background signals in the data. Finally, prospects to reach lower background levels down to $10^{-7} \, \text{counts keV}^{-1} \, \text{cm}^{-2} \, \text{s}^{-1}$ will be discussed.
△ Less
Submitted 10 March, 2024;
originally announced March 2024.
-
Searching for WIMPs with TREX-DM: achievements and challenges
Authors:
Juan F. Castel,
Susana Cebrián,
Theopisti Dafni,
David Díez-Ibáñez,
Álvaro Ezquerro,
Javier Galán,
Juan Antonio García,
Igor G. Irastorza,
María Jiménez,
Gloria Luzón,
Cristina Margalejo,
Ángel de Mira,
Hector Mirallas,
Luis Obis,
Alfonso Ortiz de Solórzano,
Oscar Pérez,
Jaime Ruz,
Julia Vogel
Abstract:
The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon mixtures, at different pressures from 1 to 4 bar. By achieving a low energy threshold of 1 keV$_{ee}$ and a background level of 80 counts keV$^{-1}$ Kg$^{-1}$ day…
▽ More
The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon mixtures, at different pressures from 1 to 4 bar. By achieving a low energy threshold of 1 keV$_{ee}$ and a background level of 80 counts keV$^{-1}$ Kg$^{-1}$ day$^{-1}$ in the region from 1 to 7 keV$_{ee}$, the experiment demonstrates its potential to search for low-mass WIMPs. Two of the most important challenges currently faced are the reduction of both, background level and energy threshold. With respect to the energy threshold, recently a new readout plane is being developed, based on the combination of Micromegas and GEM technologies, aiming to have a pre-amplification stage that would permit very low energy thresholds, close to the single-electron ionization energy. With respect to the background reduction, apart from studies to identify and minimize contamination population, a high sensitivity alpha detector is being developed in order to allow a proper material selection for the TREX-DM detector components. Both challenges, together with the optimization of the gas mixture used as target for the WIMP detection, will take TREX-DM to explore regions of WIMP's mass below 1 GeV c$^{-2}$.
△ Less
Submitted 19 December, 2023;
originally announced December 2023.
-
Ultra low background Micromegas detectors for BabyIAXO solar axion search
Authors:
E. Ferrer-Ribas,
K. Altenmüller,
B. Biasuzzi,
J. F. Castel,
S. Cebrián,
T. Dafni,
K. Desch,
D. Díez-Ibañez,
J. Galán,
J. Galindo,
J. A. García,
A. Giganon,
C. Goblin,
I. G. Irastorza,
J. Kaminski,
G. Luzón,
C. Margalejo,
H. Mirallas,
X. F. Navick,
L. Obis,
A. Ortiz de Solórzano,
J. von Oy,
T. Papaevangelou,
O. Pérez,
E. Picatoste
, et al. (5 additional authors not shown)
Abstract:
The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potentia…
▽ More
The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potential for discovery.
One of the crucial components of the project is the ultra-low background X-ray detectors that will image the X-ray photons produced by axion conversion in the experiment. The baseline detection technology for this purpose are Micromegas (Microbulk) detectors. We will show the quest and the strategy to attain the very challenging levels of background targeted for BabyIAXO that need a multi-approach strategy coming from ground measurements, screening campaigns of components of the detector, underground measurements, background models, in-situ background measurements as well as powerful rejection algorithms. First results from the commissioning of the BabyIAXO prototype will be shown.
△ Less
Submitted 22 May, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors
Authors:
K.,
Altenmüller,
J. F. Castel,
S. Cebrián,
T. Dafní,
D. Díez-Ibáñez,
J. Galán,
J. Galindo,
J. A. García,
I. G. Irastorza,
I. Katsioulas,
P. Knights,
G. Luzón,
I. Manthos,
C. Margalejo,
J. Matthews,
K. Mavrokoridis,
H. Mirallas,
T. Neep,
K. Nikolopoulos,
L. Obis,
A. Ortiz de Solórzano,
O. Pérez,
B. Philippou,
R. Ward
Abstract:
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potenti…
▽ More
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potential source of background. Several purifiers are studied for their O 2 and H 2 O purification efficiency and Rn emanation rates, aiming to identify the lowest-Rn options. Furthermore, the absorption of quenchers by the purifiers is assessed when used in a recirculating closed-loop gas system.
△ Less
Submitted 18 November, 2022;
originally announced November 2022.
-
Search for Dark Matter Axions with CAST-CAPP
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (39 additional authors not shown)
Abstract:
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a st…
▽ More
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to $g_{aγγ} = 8 \times {10^{-14}}$ $GeV^{-1}$ at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.
△ Less
Submitted 5 November, 2022;
originally announced November 2022.
-
Microbulk Micromegas in non-flammable mixtures of argon and neon at high pressure
Authors:
F. J. Iguaz,
T. Dafni,
C. Canellas,
J. F. Castel,
S. Cebrián,
J. G. Garza,
I. G. Irastorza,
G. Luzón,
H. Mirallas,
E. Ruiz Chóliz
Abstract:
We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of drift and amplification voltages and pressures from 1 bar to 10 bar for argon and from 5 bar to 10 bar in neon, in steps of 1 bar. Maximum gains higher than 1.7e3 (…
▽ More
We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of drift and amplification voltages and pressures from 1 bar to 10 bar for argon and from 5 bar to 10 bar in neon, in steps of 1 bar. Maximum gains higher than 1.7e3 (1.7e4) in argon (neon) are measured for all pressures, remarkably without the significant decrease with pressure typically observed in other amplification structures. A competitive energy resolution at 22.1 keV, but with a slight degradation with pressure, is observed:from 10.8% at 1 bar to 15.6% FWHM at 10 bar in argon and from 8.3% at 5 bar to 15.0% FWHM at1 10 bar in neon. The experimental setup, procedure and the results will be presented and discussed in detail. The work is motivated by the TREX-DM experiment, that is operating in the Laboratorio Subterráneo de Canfranc with the mentioned mixtures, although the results may be of interest for other applications of time projection chambers at high pressures.
△ Less
Submitted 5 June, 2022; v1 submitted 18 April, 2022;
originally announced April 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination
Authors:
Konrad Altenmüller,
Juan F. Castel,
Susana Cebrián,
Theopisti Dafni,
David Díez-Ibáñez,
Javier Galán,
Javier Galindo,
Juan Antonio García,
Igor G. Irastorza,
Gloria Luzón,
Cristina Margalejo,
Hector Mirallas,
Luis Obis,
Alfonso Ortiz de Solórzano,
Oscar Pérez
Abstract:
Surface contamination of $^{222}$Rn progeny from the $^{238}$U natural decay chain is one of the most difficult background contributions to measure in rare event searches experiments. In this work we propose AlphaCAMM, a gaseous chamber read with a segmented Micromegas, for the direct measurement of $^{210}$Pb surface contamination of flat samples. The detection concept exploits the readout capabi…
▽ More
Surface contamination of $^{222}$Rn progeny from the $^{238}$U natural decay chain is one of the most difficult background contributions to measure in rare event searches experiments. In this work we propose AlphaCAMM, a gaseous chamber read with a segmented Micromegas, for the direct measurement of $^{210}$Pb surface contamination of flat samples. The detection concept exploits the readout capabilities of the Micromegas detectors for the reconstruction of $^{210}$Po alpha tracks to increase the signal-to-background ratio. We report here on the design and realization of a first 26$\times$26 cm$^2$ non-radiopure prototype, with which the detection concept is demonstrated by the use of a new algorithm for the reconstruction of alpha tracks. AlphaCAMM aims for minimum detectable $^{210}$Pb activities of $100$ nBq cm$^{-2}$ and sensitivity upper limits about $60$ nBq cm$^{-2}$ at 95\% of C.L., which requires an intrinsic background level of $5\times10^{-8}$ alphas cm$^{-2}$ s$^{-1}$. We discuss here the prospects to reach these sensitivity goals with a radiopure AlphaCAMM prototype currently under construction.
△ Less
Submitted 20 July, 2022; v1 submitted 5 January, 2022;
originally announced January 2022.
-
REST-for-Physics, a ROOT-based framework for event oriented data analysis and combined Monte Carlo response
Authors:
Konrad Altenmüller,
Susana Cebrián,
Theopisti Dafni,
David Díez-Ibáñez,
Javier Galán,
Javier Galindo,
Juan Antonio García,
Igor G. Irastorza,
Gloria Luzón,
Cristina Margalejo,
Hector Mirallas,
Luis Obis,
Oscar Pérez,
Ke Han,
Kaixiang Ni,
Yann Bedfer,
Barbara Biasuzzi,
Esther Ferrer-Ribas,
Damien Neyret,
Thomas Papaevangelou,
Cristian Cogollos,
Eduardo Picatoste
Abstract:
The REST-for-Physics (Rare Event Searches Toolkit for Physics) framework is a ROOT-based solution providing the means to process and analyze experimental or Monte Carlo event data. Special care has been taken on the traceability of the code and the validation of the results produced within the framework, together with the connectivity between code and data stored registered through specific versio…
▽ More
The REST-for-Physics (Rare Event Searches Toolkit for Physics) framework is a ROOT-based solution providing the means to process and analyze experimental or Monte Carlo event data. Special care has been taken on the traceability of the code and the validation of the results produced within the framework, together with the connectivity between code and data stored registered through specific version metadata members.
The framework development was originally motivated to cover the needs at Rare Event Searches experiments (experiments looking for phenomena having extremely low occurrence probability like dark matter or neutrino interactions or rare nuclear decays), and its components naturally implement tools to address the challenges in these kinds of experiments; the integration of a detector physics response, the implementation of signal processing routines, or topological algorithms for physical event identification are some examples. Despite this specialization, the framework was conceived thinking in scalability, and other event-oriented applications could benefit from the data processing routines and/or metadata description implemented in REST, being the generic framework tools completely decoupled from dedicated libraries.
REST-for-Physics is a consolidated piece of software already serving the needs of different physics experiments - using gaseous Time Projection Chambers (TPCs) as detection technology - for background data analysis and detector characterization, as well as generic detector R\&D. Even though REST has been exploited mainly with gaseous TPCs, the code could be easily applied or adapted to other detection technologies. We present in this work an overview of REST-for-Physics, providing a broad perspective to the infrastructure and organization of the project as a whole. The framework and its different components will be described in the text.
△ Less
Submitted 19 November, 2021; v1 submitted 13 September, 2021;
originally announced September 2021.
-
First results of the CAST-RADES haloscope search for axions at 34.67 $μ$eV
Authors:
A. Álvarez Melcón,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
H. Bräuniger,
S. Calatroni,
G. Cantatore,
F. Caspers,
J. F Castel,
S. A. Cetin,
C. Cogollos,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
A. Díaz-Morcillo,
B. Döbrich,
H. Fischer,
W. Funk,
J. D Gallego,
J. M García Barceló,
A. Gardikiotis,
J. Garza,
B. Gimeno,
S. Gninenko
, et al. (34 additional authors not shown)
Abstract:
We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$μ$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An…
▽ More
We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$μ$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g$_{aγ}\gtrsim 4\times10^{-13} \text{GeV}^{-1}$ over a mass range of 34.6738 $μ$eV < $m_a$ < 34.6771 $μ$eV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 $μ$eV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.
△ Less
Submitted 27 October, 2021; v1 submitted 28 April, 2021;
originally announced April 2021.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
The TREX-DM experiment at the Canfranc Underground Laboratory
Authors:
J Castel,
S Cebrián,
T Dafni,
J Galán,
IG Irastorza,
G Luzón,
C Margalejo,
H Mirallas,
A Ortiz de Solórzano,
A Peiró,
E Ruiz-Chóliz
Abstract:
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly…
▽ More
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly presented.
△ Less
Submitted 22 March, 2020; v1 submitted 30 October, 2019;
originally announced October 2019.
-
Physics potential of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
D. Attie,
S. Basso,
P. Brun,
N. Bykovskiy,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
M. Cicoli,
M. Civitani,
C. Cogollos,
J. P. Conlon,
D. Costa,
T. Dafni,
R. Daido,
A. V. Derbin,
M. A. Descalle,
K. Desch,
I. S. Dratchnev,
B. Döbrich,
A. Dudarev,
E. Ferrer-Ribas,
I. Fleck,
J. Galán,
G. Galanti
, et al. (66 additional authors not shown)
Abstract:
We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the…
▽ More
We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the strong CP problem, can account for the cold dark matter of the Universe and be responsible for the anomalous cooling observed in a number of stellar systems. At the same time, IAXO will have enough sensitivity to detect lower mass axions invoked to explain: 1) the origin of the anomalous "transparency" of the Universe to gamma-rays, 2) the observed soft X-ray excess from galaxy clusters or 3) some inflationary models. In addition, we review string theory axions with parameters accessible by IAXO and discuss their potential role in cosmology as Dark Matter and Dark Radiation as well as their connections to the above mentioned conundrums.
△ Less
Submitted 6 June, 2019; v1 submitted 19 April, 2019;
originally announced April 2019.
-
Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment
Authors:
J Galan,
X Chen,
H Du,
C Fu,
K Giboni,
F Giuliani,
K Han,
B Jiang,
X Ji,
H Lin,
Y Lin,
J Liu,
K Ni,
X Ren,
S Wang,
S Wu,
C Xie,
Y Yang,
D Zhang,
T Zhang,
L Zhao,
S Aune,
Y Bedfer,
E Berthoumieux,
D Calvet
, et al. (42 additional authors not shown)
Abstract:
The PandaX-III experiment plans to search for neutrinoless double beta decay (0$νββ$) of $^{136}$Xe in the China **** underground Laboratory (CJPL). The experiment will use a high pressure gaseous Time Projection Chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to the software side of the experiment. As software tool we use REST, a f…
▽ More
The PandaX-III experiment plans to search for neutrinoless double beta decay (0$νββ$) of $^{136}$Xe in the China **** underground Laboratory (CJPL). The experiment will use a high pressure gaseous Time Projection Chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to the software side of the experiment. As software tool we use REST, a framework developed for the reconstruction and simulation of TPC-based detector systems. We study the potential for background reduction by introducing appropiate parameters based on the properties of 0$νββ$ events. We exploit for the first time not only the energy density of the electron track-ends, but also the electron scattering angles produced by an electron near the end of its trajectory. To implement this, we have added new algorithms for detector signal and track processing inside REST. Their assessment shows that background can be reduced by about 7 orders of magnitude while kee** 0$νββ$ efficiency above 20% for the PandaX-III baseline readout scheme, a 2-dimensional 3mm-pitch stripped readout. More generally, we use the potential of REST to handle 2D/3D data to assess the impact on signal-to-background significance at different detector granularities, and to validate the PandaX-III baseline choice. Finally, we demonstrate the potential to discriminate surface background events generated at the readout plane in the absence of $t_o$, by making use of event parameters related with the diffusion of electrons.
△ Less
Submitted 22 July, 2019; v1 submitted 10 March, 2019;
originally announced March 2019.
-
Background assessment for the TREX Dark Matter experiment
Authors:
J. Castel,
S. Cebrian,
I. Coarasa,
T. Dafni,
J. Galan,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
H. Mirallas,
A. Ortiz de Solorzano,
E. Ruiz-Choliz
Abstract:
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing…
▽ More
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
△ Less
Submitted 22 September, 2019; v1 submitted 11 December, 2018;
originally announced December 2018.
-
Design and commissioning of a 600 L Time Projection Chamber with Microbulk Micromegas
Authors:
Heng Lin,
Denis Calvet,
Lei Chen,
Xun Chen,
Theopisti Dafni,
Changbo Fu,
Javier Galan,
Ke Han,
Shouyang Hu,
Yikai Huo,
Igor G. Irastorza,
Xiangdong Ji,
Xiaomei Li,
Xinglong Li,
Jianglai Liu,
Hector Mirallas,
Damien Neyret,
Kaixiang Ni,
Hao Qiao,
Xiangxiang Ren,
Shaobo Wang,
Siguang Wang,
Yong Yang,
Ying Yuan,
Tao Zhang
, et al. (1 additional authors not shown)
Abstract:
We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an active volume of 270 L. At 10 bar operating pressure, the active volume contains about 20 kg of xenon gas and can image charged particle tracks. Drift electrons…
▽ More
We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an active volume of 270 L. At 10 bar operating pressure, the active volume contains about 20 kg of xenon gas and can image charged particle tracks. Drift electrons are collected by the charge readout plane, which accommodates a tessellation of seven Micromegas modules. Each of the Micromegas covers a square of 20 cm by 20 cm. A new type of Microbulk Micromegas is chosen for this application due to its good gain uniformity and low radioactive contamination. Initial commissioning results with 1 Micromegas module running with 1 bar argon and isobutane gas mixture and 5 bar xenon and trimethylamine (TMA) gas mixture are reported. We also recorded extended background tracks from cosmic ray events and highlighted the unique tracking feature of this gaseous TPC.
△ Less
Submitted 27 November, 2019; v1 submitted 9 April, 2018;
originally announced April 2018.
-
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Authors:
F Aznar,
J Castel,
S Cebrian,
I Coarasa,
T Dafni,
J Galan,
JG Garza,
FJ Iguaz,
IG Irastorza,
G Luzon,
H Mirallas,
A Ortiz de Solorzano,
E Ruiz-Choliz,
JA Villar
Abstract:
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effe…
▽ More
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effective thresholds below 0.4 keV (electron equivalent). The preliminary background model, following a complete material screening program, points to levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive. The status of the commissioning, description of the background model and the corresponding WIMP sensitivity will be presented here.
△ Less
Submitted 28 September, 2017;
originally announced September 2017.
-
Cosmogenic production of tritium in dark matter detectors
Authors:
J. Amare,
J. Castel,
S. Cebrian,
I. Coarasa,
C. Cuesta,
T. Dafni,
J. Galan,
E. Garcia,
J. G. Garza,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
M. Martinez,
H. Mirallas,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
E. Ruiz-Choliz,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and…
▽ More
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
△ Less
Submitted 24 November, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers
Authors:
Xun Chen,
Changbo Fu,
Javier Galan,
Karl Giboni,
Franco Giuliani,
Linghui Gu,
Ke Han,
Xiangdong Ji,
Heng Lin,
Jianglai Liu,
Kaixiang Ni,
Hiroki Kusano,
Xiangxiang Ren,
Shaobo Wang,
Yong Yang,
Dan Zhang,
Tao Zhang,
Li Zhao,
Xiangming Sun,
Shouyang Hu,
Siyu Jian,
Xinglong Li,
Xiaomei Li,
Hao Liang,
Huanqiao Zhang
, et al. (45 additional authors not shown)
Abstract:
Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China ** ** underground Laboratory (CJPL). In the first phase of the experiment…
▽ More
Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China ** ** underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% $^{136}$Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct tracks of NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure $\sim$5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.
△ Less
Submitted 27 October, 2016; v1 submitted 27 October, 2016;
originally announced October 2016.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
The potential of discrimination methods in a high pressure xenon TPC for the search of the neutrinoless double-beta decay of Xe-136
Authors:
F. J. Iguaz,
F. Aznar,
J. F. Castel,
S. Cebrian,
T. Dafni,
J. Galan,
J. G. Garza,
I. G. Irastorza,
G. Luzon,
H. Mirallas,
E. Ruiz-Choliz
Abstract:
In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which may provide extra discrimination from background events. The PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on Micromegas readout planes,…
▽ More
In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which may provide extra discrimination from background events. The PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on Micromegas readout planes, to be located at the **** Underground Laboratory in China. Its detection concept is based on two results obtained within the T-REX project: Micromegas readouts can be built with extremely low levels of radioactivity; and the operation in xenon-trimethylamine at 10 bar in realistic experimental conditions has proven an energy resolution of 3% FWHM at the region of interest. In this work, two discrimination methods are applied to simulated signal and background data in a generic 200 kg HPXe-TPC, based on two well-known algorithms of graph theory: the identification of connections and the search for the longest path. Rejection factors greater than 100 are obtained for small pixel sizes and a signal efficiency of 40%. Moreover, a new observable (the blob charge density) rejects better surface contaminations, which makes the use of a trigger signal ($T_0$) not imperative in this experiment.
△ Less
Submitted 30 September, 2016;
originally announced September 2016.
-
Micromegas for dark matter searches: CAST/IAXO & TREX-DM
Authors:
J. G. Garza,
S. Aune,
J. F. Castel,
S. Cebrián,
T. Dafni,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
I. Giomataris,
F. J. Iguaz,
I. G. Irastorza,
G. Luzón,
H. Mirallas,
T. Papaevangelou,
A. Peiró,
A. Tomás,
T. Vafeiadis
Abstract:
The most compelling candidates for Dark Matter to day are WIMPs and axions. The applicability of gasesous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) to the search of these particles is explored within this work. Both particles would produce an extremely low rate at very low energies in particle detectors. Micromegas detectors can provide both low background rates an…
▽ More
The most compelling candidates for Dark Matter to day are WIMPs and axions. The applicability of gasesous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) to the search of these particles is explored within this work. Both particles would produce an extremely low rate at very low energies in particle detectors. Micromegas detectors can provide both low background rates and low en- ergy threshold, due to the high granularity, radiopurity and uniformity of the readout. Small (few cm wide) Micromegas detectors are used to image the axion-induced x-ray signal expected in the CERN Axion Solar Telescope (CAST) experiment. We show the background levels obtained in CAST and the prospects to further reduce them to the values required by the Internation Axion Observatory (IAXO). We also present TREX-DM, a scaled-up version of the Micromegas used in axion research, but this time dedicated to the low-mass WIMP detection. TREX-DM is a high-pressure Micromegas-based TPC designed to host a few hundreds of grams of light nuclei (argon or neon) with energy thresholds potentially at the level of 100 eV. The detector is described in detail, as well as the results of the commissioning and characterization phase on surface. Besides, the back- ground model of TREX-DM is presented, along with the anticipated sensitivity of this search, which could go beyond current experimental limits.
△ Less
Submitted 21 September, 2016;
originally announced September 2016.
-
Gaseous time projection chambers for rare event detection: Results from the T-REX project. I. Double beta decay
Authors:
I. G. Irastorza,
F. Aznar,
J. Castel,
S. Cebrián,
T. Dafni,
J. Galán,
J. A. García,
J. G. Garza,
H. Gómez,
D. C. Herrera,
F. J. Iguaz,
G. Luzón,
H. Mirallas,
E. Ruiz,
L. Seguí,
A. Tomás
Abstract:
As part of the T-REX project, a number of R&D and prototy** activities have been carried out during the last years to explore the applicability of gaseous Micromegas-read TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. In both this and its companion paper, we compile the main results of the project and give an outlook of application prospects…
▽ More
As part of the T-REX project, a number of R&D and prototy** activities have been carried out during the last years to explore the applicability of gaseous Micromegas-read TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. In both this and its companion paper, we compile the main results of the project and give an outlook of application prospects for this detection technique. While in the companion paper we focus on axions and WIMPs, in this paper we focus on the results regarding the measurement of the DBD of $^{136}$Xe in a high pressure Xe (HPXe) TPC. Particularly relevant are the results obtained in Xe + TMA mixtures with microbulk Micromegas, showing very promising results in terms of gain, stability of operation, and energy resolution at pressures up to 10 bar. TMA at levels of $\sim$1\% reduces electron diffusion by a factor of 10 with respect to pure Xe, improving the quality of the topological pattern, with a positive impact on the discrimination capability. Operation with a medium size prototype (30 cm diameter and 38 cm drift) of 1 kg of Xe at 10 bar in the fiducial volumen has allowed to test the detection concept in realistic experimental conditions. Microbulk Micromegas are able to image the DBD ionization signature with high quality while, at the same time, measuring its energy deposition with a resolution of at least $\sim$3% FWHM @ Q$_{ββ}$, and probably down to $\sim$1% FWHM. In addition, first results on the topological signature information show promising background discrimination capabilities out of reach of other experimental implementations. Moreover, microbulk Micromegas have very low levels of intrinsic radioactivity, and offer cost-effective scaling-up options. All these results demonstrate that Micromegas-read HPXe TPC is a very competitive technique for the next generation DBD experiments.
△ Less
Submitted 24 December, 2015;
originally announced December 2015.
-
Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter
Authors:
I. G. Irastorza,
F. Aznar,
J. Castel,
S. Cebrián,
T. Dafni,
J. Galán,
J. A. García,
J. G. Garza,
H. Gómez,
D. C. Herrera,
F. J. Iguaz,
G. Luzón,
H. Mirallas,
E. Ruiz,
L. Seguí,
A. Tomás
Abstract:
As part of the T-REX project, a number of R&D and prototy** activities have been carried out during the last years to explore the applicability of Micromegas-read gaseous TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. While in the companion paper we focus on DBD, in this paper we focus on the results regarding the search for dark matter candi…
▽ More
As part of the T-REX project, a number of R&D and prototy** activities have been carried out during the last years to explore the applicability of Micromegas-read gaseous TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. While in the companion paper we focus on DBD, in this paper we focus on the results regarding the search for dark matter candidates, both axions and WIMPs. Small ultra-low background Micromegas detectors are used to image the x-ray signal expected in axion helioscopes like CAST at CERN. Background levels as low as $0.8\times 10^{-6}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$ have already been achieved in CAST while values down to $\sim10^{-7}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained in a test bench placed underground in the Laboratorio Subterráneo de Canfranc. Prospects to consolidate and further reduce these values down to $\sim10^{-8}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$will be described. Such detectors, placed at the focal point of x-ray telescopes in the future IAXO experiment, would allow for 10$^5$ better signal-to-noise ratio than CAST, and search for solar axions with $g_{aγ}$ down to few 10$^{12}$ GeV$^{-1}$, well into unexplored axion parameter space. In addition, a scaled-up version of these TPCs, properly shielded and placed underground, can be competitive in the search for low-mass WIMPs. The TREX-DM prototype, with $\sim$0.300 kg of Ar at 10 bar, or alternatively $\sim$0.160 kg of Ne at 10 bar, and energy threshold well below 1 keV, has been built to test this concept. We will describe the main technical solutions developed, as well as the results from the commissioning phase on surface. The anticipated sensitivity of this technique might reach $\sim10^{-44}$ cm$^2$ for low mass ($<10$ GeV) WIMPs, well beyond current experimental limits in this mass range.
△ Less
Submitted 6 May, 2016; v1 submitted 19 December, 2015;
originally announced December 2015.
-
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
Authors:
F. Aznar,
J. Castel,
F. E. Christensen,
T. Dafni,
T. A. Decker,
E. Ferrer-Ribas,
J. A. Garcia,
I. Giomataris,
J. G. Gracia,
C. J. Hailey,
R. M. Hill,
F. J. Iguaz,
I. G. Irastorza,
A. C. Jakobsen,
G. Luzon,
H. Mirallas,
T. Papaevangelou,
M. J. Pivovaroff,
J. Ruz,
T. Vafeiadis,
J. K. Vogel
Abstract:
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed…
▽ More
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and signal spot area.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
Modelling the behaviour of microbulk Micromegas in Xenon/trimethylamine gas
Authors:
E. Ruiz-Choliz,
D. Gonzalez-Diaz,
A. Diago,
J. Castel,
T. Dafni,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
H. Mirallas,
O. Sahin,
R. Veenhof
Abstract:
We model the response of a state of the art micro-hole single-stage charge amplication device (`microbulk' Micromegas) in a gaseous atmosphere consisting of Xenon/trimethylamine at various concentrations and pressures. The amplifying structure, made with photo-lithographic techniques similar to those followed in the fabrication of gas electron multipliers (GEMs), consisted of a 100 um-side equilat…
▽ More
We model the response of a state of the art micro-hole single-stage charge amplication device (`microbulk' Micromegas) in a gaseous atmosphere consisting of Xenon/trimethylamine at various concentrations and pressures. The amplifying structure, made with photo-lithographic techniques similar to those followed in the fabrication of gas electron multipliers (GEMs), consisted of a 100 um-side equilateral-triangle pattern with 50 um-diameter holes placed at its vertexes. Once the primary electrons are guided into the holes by virtue of an optimized field configuration, avalanches develop along the 50 um-height channels etched out of the original doubly copper-clad polyimide foil. In order to properly account for the strong field gradients at the holes' entrance as well as for the fluctuations of the avalanche process (that ultimately determine the achievable energy resolution), we abandoned the hydrodynamic framework, resorting to a purely microscopic description of the electron trajectories as obtained from elementary cross-sections. We show that achieving a satisfactory description needs additional assumptions about atom-molecule (Penning) transfer reactions and charge recombination to be made.
△ Less
Submitted 16 June, 2015;
originally announced June 2015.
-
Low Background Micromegas in CAST
Authors:
J. G. Garza,
S. Aune,
D. Calvet,
J. F. Castel,
F. E. Christensen,
T. Dafni,
M. Davenport,
T. Decker,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
I. Giomataris,
R. M. Hill,
F. J. Iguaz,
I. G. Irastorza,
A. C. Jakobsen,
D. Jourde,
H. Mirallas,
I. Ortega,
T. Papaevangelou,
M. J. Pivovaroff,
J. Ruz,
A. Tomás,
T. Vafeiadis,
J. K. Vogel
Abstract:
Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activiti…
▽ More
Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activities for the future International Axion Observatory (IAXO). The use of low background techniques and the application of discrimination algorithms based on the high granularity of the readout have led to background levels below 10$^{-6}$ counts/keV/cm$^2$/s, more than a factor 100 lower than the first generation of Micromegas detectors. The best levels achieved at the Canfranc Underground Laboratory (LSC) are as low as 10$^{-7}$ counts/keV/cm$^2$/s, showing good prospects for the application of this technology in IAXO. The current background model, based on underground and surface measurements, is presented, as well as the strategies to further reduce the background level. Finally, we will describe the R&D paths to achieve sub-keV energy thresholds, which could broaden the physics case of axion helioscopes.
△ Less
Submitted 17 March, 2015;
originally announced March 2015.
-
X-ray detection with Micromegas with background levels below 10$^{-6}$ keV$^{-1}$cm$^{-2}$s$^{-1}$
Authors:
S. Aune,
F. Aznar,
D. Calvet,
T. Dafni,
A. Diago,
F. Druillole,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
A. Gardikiotis,
J. G. Garza,
T. Geralis,
I. Giomataris,
H. Gómez,
D. González-Díaz,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
D. Jourde,
G. Luzón,
H. Mirallas,
J. P. Mols,
T. Papaevangelou,
A. Rodríguez
, et al. (4 additional authors not shown)
Abstract:
Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detector…
▽ More
Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detectors' response. The upgrades encompass the readout electronics, a new detector design and the implementation of a more efficient cosmic muon veto system. Background levels below 10$^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained at sea level for the first time, demonstrating the feasibility of the expectations posed by IAXO, the next generation axion helioscope. Some results obtained with a set of measurements conducted in the x-ray beam of the CAST Detector Laboratory will be also presented and discussed.
△ Less
Submitted 16 December, 2013;
originally announced December 2013.