-
Measurement of the Neutron Cross Section on Argon Between 95 and 720 MeV
Authors:
S. Martynenko,
B. Bhandari,
J. Bian,
K. Bilton,
C. Callahan,
J. Chaves,
H. Chen,
D. Cline,
R. L. Cooper,
D. L. Danielson,
J. Danielson,
N. Dokania,
S. Elliott,
S. Fernandes,
S. Gardiner,
G. Garvey,
V. Gehman,
F. Giuliani,
S. Glavin,
M. Gold,
C. Grant,
E. Guardincerri,
T. Haines,
A. Higuera,
J. Y. Ji
, et al. (50 additional authors not shown)
Abstract:
We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstrea…
▽ More
We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. We also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140 ns - 180 ns, 120 ns - 140 ns, 112 ns - 120 ns, 104 ns - 112 ns, 96 ns - 104 ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin: $σ(146~\rm{MeV})=0.60^{+0.14}_{-0.14}\pm0.08$(syst) b, $σ(236~\rm{MeV})=0.72^{+0.10}_{-0.10}\pm0.04$(syst) b, $σ(319~\rm{MeV})=0.80^{+0.13}_{-0.12}\pm0.040$(syst) b, $σ(404~\rm{MeV})=0.74^{+0.14}_{-0.09}\pm0.04$(syst) b, $σ(543~\rm{MeV})=0.74^{+0.09}_{-0.09}\pm0.04$(syst) b.
△ Less
Submitted 14 March, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
MiniBooNE and MicroBooNE Combined Fit to a 3+1 Sterile Neutrino Scenario
Authors:
A. A. Aguilar-Arevalo,
B. C. Brown,
J. M. Conrad,
R. Dharmapalan,
A. Diaz,
Z. Djurcic,
D. A. Finley,
R. Ford,
G. T. Garvey,
S. Gollapinni,
A. Hourlier,
E. -C. Huang,
N. W. Kamp,
G. Karagiorgi,
T. Katori,
T. Kobilarcik,
K. Lin,
W. C. Louis,
C. Mariani,
W. Marsh,
G. B. Mills,
J. Mirabal-Martinez,
C. D. Moore,
R. H. Nelson,
J. Nowak
, et al. (14 additional authors not shown)
Abstract:
This letter presents the results from the MiniBooNE experiment within a full "3+1" scenario where one sterile neutrino is introduced to the three-active-neutrino picture. In addition to electron-neutrino appearance at short-baselines, this scenario also allows for disappearance of the muon-neutrino and electron-neutrino fluxes in the Booster Neutrino Beam, which is shared by the MicroBooNE experim…
▽ More
This letter presents the results from the MiniBooNE experiment within a full "3+1" scenario where one sterile neutrino is introduced to the three-active-neutrino picture. In addition to electron-neutrino appearance at short-baselines, this scenario also allows for disappearance of the muon-neutrino and electron-neutrino fluxes in the Booster Neutrino Beam, which is shared by the MicroBooNE experiment. We present the 3+1 fit to the MiniBooNE electron-(anti)neutrino and muon-(anti)neutrino data alone, and in combination with MicroBooNE electron-neutrino data. The best-fit parameters of the combined fit with the exclusive CCQE analysis (inclusive analysis) are $Δm^2 = 0.29 eV^2 (0.33 eV^2)$, $|U_{e4}|^2 = 0.016 (0.500)$, $|U_{μ4}|^2 = 0.500 (0.500)$, and $\sin^2(2θ_{μe})=0.0316 (1.0)$. Comparing the no-oscillation scenario to the 3+1 model, the data prefer the 3+1 model with a $Δχ^2/\text{dof} = 24.7 / 3 (17.3 / 3)$, a $4.3σ(3.4σ)$ preference assuming the asymptotic approximation given by Wilks' theorem.
△ Less
Submitted 9 September, 2022; v1 submitted 5 January, 2022;
originally announced January 2022.
-
MiniBooNE Data Releases
Authors:
A. A. Aguilar-Arevalo,
B. C. Brown,
J. M. Conrad,
R. Dharmapalan,
A. Diaz,
Z. Djurcic,
D. A. Finley,
R. Ford,
G. T. Garvey,
S. Gollapinni,
A. Hourlier,
E. -C. Huang,
N. W. Kamp,
G. Karagiorgi,
T. Katori,
T. Kobilarcik,
K. Lin,
W. C. Louis,
C. Mariani,
W. Marsh,
G. B. Mills,
J. Mirabal-Martinez,
C. D. Moore,
R. H. Nelson,
J. Nowak
, et al. (16 additional authors not shown)
Abstract:
The MiniBooNE experiment has provided data releases for most publications. Occasionally it is necessary to move data release pages. This document provides a single point of reference that will be updated by the collaboration to point to the present location of the MiniBooNE data releases.
The MiniBooNE experiment has provided data releases for most publications. Occasionally it is necessary to move data release pages. This document provides a single point of reference that will be updated by the collaboration to point to the present location of the MiniBooNE data releases.
△ Less
Submitted 25 October, 2021;
originally announced October 2021.
-
The Mini-CAPTAIN Liquid Argon Time Projection Chamber
Authors:
CAPTAIN Collaboration,
C. E. Taylor,
B. Bhandari,
J. Bian,
K. Bilton,
C. Callahan,
J. Chaves,
H. Chen,
D. Cline,
R. L. Cooper,
D. L. Danielson,
J. Danielson,
N. Dokania,
S. Elliot,
S. Fernandes,
S. Gardiner,
G. Garvey,
V. Gehman,
F. Giuliani,
S. Glavin,
M. Gold,
C. Grant,
E. Guardincerri,
T. Haines,
A. Higuera
, et al. (51 additional authors not shown)
Abstract:
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryost…
▽ More
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Updated MiniBooNE Neutrino Oscillation Results with Increased Data and New Background Studies
Authors:
MiniBooNE Collaboration,
A. A. Aguilar-Arevalo,
B. C. Brown,
J. M. Conrad,
R. Dharmapalan,
A. Diaz,
Z. Djurcic,
D. A. Finley,
R. Ford,
G. T. Garvey,
S. Gollapinni,
A. Hourlier,
E. C. Huang,
N. W. Kamp,
G. Karagiorgi,
T. Katori,
T. Kobilarcik,
K. Lin,
W. C. Louis,
C. Mariani,
W. Marsh,
G. B. Mills,
J. Mirabal-Martinez,
C. D. Moore,
R. H. Nelson
, et al. (17 additional authors not shown)
Abstract:
The MiniBooNE experiment at Fermilab reports a total excess of $638.0 \pm 132.8$ electron-like events ($4.8 σ$) from a data sample corresponding to $18.75 \times 10^{20}$ protons-on-target in neutrino mode, which is a 46\% increase in the data sample with respect to previously published results, and $11.27 \times 10^{20}$ protons-on-target in antineutrino mode. The additional statistics allow seve…
▽ More
The MiniBooNE experiment at Fermilab reports a total excess of $638.0 \pm 132.8$ electron-like events ($4.8 σ$) from a data sample corresponding to $18.75 \times 10^{20}$ protons-on-target in neutrino mode, which is a 46\% increase in the data sample with respect to previously published results, and $11.27 \times 10^{20}$ protons-on-target in antineutrino mode. The additional statistics allow several studies to address questions on the source of the excess. First, we provide two-dimensional plots in visible energy and cosine of the angle of the outgoing lepton, which can provide valuable input to models for the event excess. Second, we test whether the excess may arise from photons that enter the detector from external events or photons exiting the detector from $π^0$ decays in two model independent ways. Beam timing information shows that almost all of the excess is in time with neutrinos that interact in the detector. The radius distribution shows that the excess is distributed throughout the volume, while tighter cuts on the fiducal volume increase the significance of the excess. We conclude that models of the event excess based on entering and exiting photons are disfavored.
△ Less
Submitted 8 March, 2021; v1 submitted 30 June, 2020;
originally announced June 2020.
-
First Measurement of the Total Neutron Cross Section on Argon Between 100 and 800 MeV
Authors:
B. Bhandari,
J. Bian,
K. Bilton,
C. Callahan,
J. Chaves,
H. Chen,
D. Cline,
R. L. Cooper,
D. Danielson,
J. Danielson,
N. Dokania,
S. Elliott,
S. Fernandes,
S. Gardiner,
G. Garvey,
V. Gehman,
F. Giuliani,
S. Glavin,
M. Gold,
C. Grant,
E. Guardincerri,
T. Haines,
A. Higuera,
J. Y. Ji,
R. Kadel
, et al. (51 additional authors not shown)
Abstract:
We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided…
▽ More
We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided in bins of the neutron kinetic energy calculated from time-of-flight measurements. These interactions are reconstructed with custom-made algorithms specifically designed for the data in a time projection chamber the size of the Mini-CAPTAIN detector. The energy averaged cross section is $0.91 \pm{} 0.10~\mathrm{(stat.)} \pm{} 0.09~\mathrm{(sys.)}~\mathrm{barns}$. A comparison of the measured cross section is made to the GEANT4 and FLUKA event generator packages.
△ Less
Submitted 26 June, 2019; v1 submitted 12 March, 2019;
originally announced March 2019.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
The CAPTAIN Detector and Physics Program
Authors:
The CAPTAIN Collaboration,
H. Berns,
H. Chen,
D. Cline,
J. Danielson,
Z. Djurcic,
S. Elliott,
G. Garvey,
V. Gehman,
C. Grant,
E. Guardincerri,
R. Kadel,
T. Kutter,
D. Lee,
K. Lee,
Q. Liu,
W. Louis,
C. Mauger,
C. McGrew,
R. McTaggart,
J. Medina,
W. Metcalf,
G. Mills,
J. Mirabal-Martinez,
S. Mufson
, et al. (22 additional authors not shown)
Abstract:
The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented wi…
▽ More
The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented with a 2,000 channel liquid argon TPC and a photon detection system. Subsequent to the commissioning phase, the detector will collect data in a high-energy neutron beamline that is part of the Los Alamos Neutron Science Center to measure cross-sections of spallation products that are backgrounds to measurements of neutrinos from a supernova burst, cross-sections of events that mimic the electron neutrino appearance signal in long-baseline neutrino physics and neutron signatures to constrain neutrino energy reconstruction in LBNE's long-baseline program. Subsequent to the neutron running, the CAPTAIN detector will be moved to a neutrino source. Two possibilities are an on-axis run in the NuMI beamline at FNAL and a run in the neutrino source produced by the SNS. An on-axis run at NuMI produces more than one million events of interest in a two or three year run at neutrino energies between 1 and 10 GeV - complementary to the MicroBooNE experiment, which will measure similar interactions at a lower energy range - 0.5 to 2 GeV. At the SNS the neutrinos result from the decays stopped positively charged pions and muons yielding a broad spectrum up to 50 MeV. If located close to the spallation target, CAPTAIN can detect several thousand events per year in the same neutrino energy regime where neutrinos from a supernova burst are. Measurements at the SNS yield a first measurement of the cross- section of neutrinos on argon in this important energy regime.
△ Less
Submitted 6 September, 2013;
originally announced September 2013.