-
RADES axion search results with a High-Temperature Superconducting cavity in an 11.7 T magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
X. Granados,
J. Gutierrez,
L. Herwig,
I. G. Irastorza,
N. Lamas,
A. Lozano-Guerrero,
W. L. Millar,
C. Malbrunot,
J. Miralda-Escudé,
P. Navarro,
J. R. Navarro-Madrid,
T. Puig,
M. Siodlaczek,
G. T. Telles
, et al. (1 additional authors not shown)
Abstract:
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hint…
▽ More
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hinting at an axion-like particle was found. Correspondingly, in this mass range, a limit on the axion to photon coupling-strength was set in the range between g$_{aγ}\gtrsim$ 6.2e-13 GeV$^{-1}$ and g$_{aγ}\gtrsim$ 1.54e-13 GeV$^{-1}$ with a 95% confidence level.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
Thin Film (High Temperature) Superconducting Radiofrequency Cavities for the Search of Axion Dark Matter
Authors:
J. Golm,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
B. Döbrich,
J. D. Gallego,
J. M. García Barceló,
X. Granados,
J. Gutierrez,
I. G. Irastorza,
T. Koettig,
N. Lamas,
J. Liberadzka-Porret,
C. Malbrunot,
W. L. Millar,
P. Navarro,
C. Pereira Carlos,
T. Puig,
G. J. Rosaz,
M. Siodlaczek,
G. Telles,
W. Wuensch
Abstract:
The axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 $μ$eV. The figure of merit of our detector depends linearly on the quali…
▽ More
The axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 $μ$eV. The figure of merit of our detector depends linearly on the quality factor of the cavity and therefore we are researching the possibility of coating our cavities with different superconducting materials to increase the quality factor. Since the experiment operates in strong magnetic fields of 11 T and more, superconductors with high critical magnetic fields are necessary. Suitable materials for this application are for example REBa$_2$Cu$_3$O$_{7-x}$, Nb$_3$Sn or NbN. We designed a microwave cavity which resonates at around 9~GHz, with a geometry optimized to facilitate superconducting coating and designed to fit in the bore of available high-field accelerator magnets at CERN. Several prototypes of this cavity were coated with different superconducting materials, employing different coating techniques. These prototypes were characterized in strong magnetic fields at 4.2 K.
△ Less
Submitted 9 February, 2022; v1 submitted 4 October, 2021;
originally announced October 2021.
-
Effect of dc voltage pulsing on high-vacuum electrical breakdowns near Cu surfaces
Authors:
Anton Saressalo,
Iaroslava Profatilova,
William L. Millar,
Andreas Kyritsakis,
Sergio Calatroni,
Walter Wuensch,
Flyura Djurabekova
Abstract:
Vacuum electrical breakdowns, also known as vacuum arcs, are a limiting factor in many devices that are based on application of high electric fields near their component surfaces. Understanding of processes that lead to breakdown events may help mitigating their appearance and suggest ways for improving operational efficiency of power-consuming devices. Stability of surface performance at a given…
▽ More
Vacuum electrical breakdowns, also known as vacuum arcs, are a limiting factor in many devices that are based on application of high electric fields near their component surfaces. Understanding of processes that lead to breakdown events may help mitigating their appearance and suggest ways for improving operational efficiency of power-consuming devices. Stability of surface performance at a given value of the electric field is affected by the conditioning state, i.e. how long the surface was exposed to this field. Hence, optimization of the surface conditioning procedure can significantly speed up the preparatory steps for high-voltage applications. In this article, we use pulsed dc systems to optimize the surface conditioning procedure of copper electrodes, focusing on the effects of voltage recovery after breakdowns, variable repetition rates as well as long waiting times between pulsing runs. Despite the differences in the experimental scales, ranging from $10^{-4}$ s between pulses, up to pulsing breaks of $10^5$ s, the experiments show that the longer the idle time between the pulses, the more probable it is that the next pulse produces a breakdown. We also notice that secondary breakdowns, i.e. those which correlate with the previous ones, take place mainly during the voltage recovery stage. We link these events with deposition of residual atoms from vacuum on the electrode surfaces. Minimizing the number of pauses during the voltage recovery stage reduces power losses due to secondary breakdown events improving efficiency of the surface conditioning.
△ Less
Submitted 10 November, 2020; v1 submitted 5 August, 2020;
originally announced August 2020.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.