Characteristics of dark current from an S-band rf gun with exchangeable photocathode system
Authors:
Frank Jackson,
Louise Cowie,
Marta Furmaniak Phillipe Goudket,
Boris Militsyn,
Julian McKenzie Tim Noakes
Abstract:
Field emission or dark current from RF electron guns is problematic for accelerators for several reasons, and can be more difficult to predict, measure and understand, compared to the main beam. The work presented here is a study of the dark current emitted from the CLARA 3GHz 2.5 cell electron gun with exchangeable photocathode, which is a type of gun used for single pass high quality low emittan…
▽ More
Field emission or dark current from RF electron guns is problematic for accelerators for several reasons, and can be more difficult to predict, measure and understand, compared to the main beam. The work presented here is a study of the dark current emitted from the CLARA 3GHz 2.5 cell electron gun with exchangeable photocathode, which is a type of gun used for single pass high quality low emittance beams for uses such as Free Electron Lasers. The main purpose of these studies was to identify sources of dark current emission within the gun, by examining the dark current distribution and patterns on scintillating screens. It is shown that the features of the patterns can be reproduced qualitatively, and to some extent quantitatively, by finite element simulations. Thus, certain surfaces within the gun and cathode apparatus which contribute most significantly to problematic dark current can be identified, and further development and preparation of the guns and their cathodes can be informed to minimise dark current.
△ Less
Submitted 2 July, 2024; v1 submitted 1 March, 2024;
originally announced March 2024.
-
Transverse phase space tomography in the CLARA accelerator test facility using image compression and machine learning
Authors:
Andrzej Wolski,
Mark A. Johnson,
Matthew King,
Boris L. Militsyn,
Peter H. Williams
Abstract:
We describe a novel technique, based on image compression and machine learning, for transverse phase space tomography in two degrees of freedom in an accelerator beamline. The technique has been used in the CLARA accelerator test facility at Daresbury Laboratory: results from the machine learning method are compared with those from a conventional tomography algorithm (algebraic reconstruction), ap…
▽ More
We describe a novel technique, based on image compression and machine learning, for transverse phase space tomography in two degrees of freedom in an accelerator beamline. The technique has been used in the CLARA accelerator test facility at Daresbury Laboratory: results from the machine learning method are compared with those from a conventional tomography algorithm (algebraic reconstruction), applied to the same data. The use of machine learning allows reconstruction of the 4D phase space distribution of the beam to be carried out much more rapidly than using conventional tomography algorithms, and also enables the use of image compression to reduce significantly the size of the data sets involved in the analysis. Results from the machine learning technique are at least as good as those from the algebraic reconstruction tomography in characterising the beam behaviour, in terms of the variation of the beam size in response to variation of the quadrupole strengths.
△ Less
Submitted 2 September, 2022;
originally announced September 2022.
-
The Development of Energy-Recovery Linacs
Authors:
Chris Adolphsen,
Kevin Andre,
Deepa Angal-Kalinin,
Michaela Arnold,
Kurt Aulenbacher,
Steve Benson,
Jan Bernauer,
Alex Bogacz,
Maarten Boonekamp,
Reinhard Brinkmann,
Max Bruker,
Oliver Brüning,
Camilla Curatolo,
Patxi Duthill,
Oliver Fischer,
Georg Hoffstaetter,
Bernhard Holzer,
Ben Hounsell,
Andrew Hutton,
Erk Jensen,
Walid Kaabi,
Dmitry Kayran,
Max Klein,
Jens Knobloch,
Geoff Krafft
, et al. (24 additional authors not shown)
Abstract:
Energy-recovery linacs (ERLs) have been emphasised by the recent (2020) update of the European Strategy for Particle Physics as one of the most promising technologies for the accelerator base of future high-energy physics. The current paper has been written as a base document to support and specify details of the recently published European roadmap for the development of energy-recovery linacs. Th…
▽ More
Energy-recovery linacs (ERLs) have been emphasised by the recent (2020) update of the European Strategy for Particle Physics as one of the most promising technologies for the accelerator base of future high-energy physics. The current paper has been written as a base document to support and specify details of the recently published European roadmap for the development of energy-recovery linacs. The paper summarises the previous achievements on ERLs and the status of the field and its basic technology items. The main possible future contributions and applications of ERLs to particle and nuclear physics as well as industrial developments are presented. The paper includes a vision for the further future, beyond 2030, as well as a comparative data base for the main existing and forthcoming ERL facilities. A series of continuous innovations, such as on intense electron sources or high-quality superconducting cavity technology, will massively contribute to the development of accelerator physics at large. Industrial applications are potentially revolutionary and may carry the development of ERLs much further, establishing another shining example of the impact of particle physics on society and its technical foundation with a special view on sustaining nature.
△ Less
Submitted 27 September, 2022; v1 submitted 5 July, 2022;
originally announced July 2022.
-
European Strategy for Particle Physics -- Accelerator R&D Roadmap
Authors:
C. Adolphsen,
D. Angal-Kalinin,
T. Arndt,
M. Arnold,
R. Assmann,
B. Auchmann,
K. Aulenbacher,
A. Ballarino,
B. Baudouy,
P. Baudrenghien,
M. Benedikt,
S. Bentvelsen,
A. Blondel,
A. Bogacz,
F. Bossi,
L. Bottura,
S. Bousson,
O. Brüning,
R. Brinkmann,
M. Bruker,
O. Brunner,
P. N. Burrows,
G. Burt,
S. Calatroni,
K. Cassou
, et al. (111 additional authors not shown)
Abstract:
The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified…
▽ More
The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.
△ Less
Submitted 30 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Pushing the Capture Limit of Thermionic Gun Linacs
Authors:
Sadiq Setiniyaz,
Alejandro Castilla,
Julian McKenzie,
Robert Apsimon,
Boris Militsyn,
Deepa Angal-Kalinin,
Graeme Burt
Abstract:
Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving uncaptured electrons to cause problems due to back bombardment, shortening of cathode life, etc. Any solution to increase capture should be effective, simple, reli…
▽ More
Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving uncaptured electrons to cause problems due to back bombardment, shortening of cathode life, etc. Any solution to increase capture should be effective, simple, reliable, compact, and low cost in order to be adopted by industry. To address this, we present the design of a 6 MeV high capture efficiency S-band electron linac that captures 90% of the initial DC beam. This linac does not require any extra parts that would increase the cost as the high efficiency is achieved via a low-field-amplitude in the first bunching cell to decrease the number of backstreaming electrons, to velocity bunch the electron beam, and recapture backstreaming electrons. Under the low field amplitude, any electrons launched at decelerating phases travel backward with low speeds, thus most of them can catch the next RF cycle, and get re-accelerated/recaptured. As the electron speed is low, the cell length is also shorter than existing linacs. Such a short field is achieved by the use of asymmetric cells with differential coupling to the side-coupled cells. Our novel design has implications for all commercial high current thermionic gun linacs for increasing beam current and increasing cathode lifetime.
△ Less
Submitted 31 August, 2021; v1 submitted 20 May, 2021;
originally announced May 2021.
-
The Large Hadron-Electron Collider at the HL-LHC
Authors:
P. Agostini,
H. Aksakal,
S. Alekhin,
P. P. Allport,
N. Andari,
K. D. J. Andre,
D. Angal-Kalinin,
S. Antusch,
L. Aperio Bella,
L. Apolinario,
R. Apsimon,
A. Apyan,
G. Arduini,
V. Ari,
A. Armbruster,
N. Armesto,
B. Auchmann,
K. Aulenbacher,
G. Azuelos,
S. Backovic,
I. Bailey,
S. Bailey,
F. Balli,
S. Behera,
O. Behnke
, et al. (312 additional authors not shown)
Abstract:
The Large Hadron electron Collider (LHeC) is designed to move the field of deep inelastic scattering (DIS) to the energy and intensity frontier of particle physics. Exploiting energy recovery technology, it collides a novel, intense electron beam with a proton or ion beam from the High Luminosity--Large Hadron Collider (HL-LHC). The accelerator and interaction region are designed for concurrent el…
▽ More
The Large Hadron electron Collider (LHeC) is designed to move the field of deep inelastic scattering (DIS) to the energy and intensity frontier of particle physics. Exploiting energy recovery technology, it collides a novel, intense electron beam with a proton or ion beam from the High Luminosity--Large Hadron Collider (HL-LHC). The accelerator and interaction region are designed for concurrent electron-proton and proton-proton operation. This report represents an update of the Conceptual Design Report (CDR) of the LHeC, published in 2012. It comprises new results on parton structure of the proton and heavier nuclei, QCD dynamics, electroweak and top-quark physics. It is shown how the LHeC will open a new chapter of nuclear particle physics in extending the accessible kinematic range in lepton-nucleus scattering by several orders of magnitude. Due to enhanced luminosity, large energy and the cleanliness of the hadronic final states, the LHeC has a strong Higgs physics programme and its own discovery potential for new physics. Building on the 2012 CDR, the report represents a detailed updated design of the energy recovery electron linac (ERL) including new lattice, magnet, superconducting radio frequency technology and further components. Challenges of energy recovery are described and the lower energy, high current, 3-turn ERL facility, PERLE at Orsay, is presented which uses the LHeC characteristics serving as a development facility for the design and operation of the LHeC. An updated detector design is presented corresponding to the acceptance, resolution and calibration goals which arise from the Higgs and parton density function physics programmes. The paper also presents novel results on the Future Circular Collider in electron-hadron mode, FCC-eh, which utilises the same ERL technology to further extend the reach of DIS to even higher centre-of-mass energies.
△ Less
Submitted 12 April, 2021; v1 submitted 28 July, 2020;
originally announced July 2020.
-
Transverse phase space characterisation in the CLARA FE accelerator test facility at Daresbury Laboratory
Authors:
A. Wolski,
D. C. Christie,
B. L. Militsyn,
D. J. Scott,
H. Kockelbergh
Abstract:
We compare three techniques for characterising the transverse phase space distribution of the beam in CLARA FE (the Compact Linear Accelerator for Research and Applications Front End, at Daresbury Laboratory, UK): emittance and optics measurements using screens at three separate beamline locations; quadrupole scans; and phase space tomography. We find that where the beam distribution has significa…
▽ More
We compare three techniques for characterising the transverse phase space distribution of the beam in CLARA FE (the Compact Linear Accelerator for Research and Applications Front End, at Daresbury Laboratory, UK): emittance and optics measurements using screens at three separate beamline locations; quadrupole scans; and phase space tomography. We find that where the beam distribution has significant structure (as in the case of CLARA FE at the time the measurements presented here were made) tomography analysis is the most reliable way to obtain a meaningful characterisation of the transverse beam properties. We present the first experimental results from four-dimensional phase space tomography: our results show that this technique can provide an insight into beam properties that are of importance for optimising machine performance.
△ Less
Submitted 23 October, 2019;
originally announced October 2019.
-
Procedure of simulations for Evaluations of Transient Parameters Stability for RF Cavities Due to Effects of Pulsed RF Heating
Authors:
V. Paramonov,
B. Militsyn,
A. Skassyrskaya
Abstract:
The Pulsed RF Heating (PRFH) is the well known effect in the development of high gradient accelerating cavities. There is a lot of research dedicated to the tolerable strength of electromagnetic field and the corresponding temperature rise leading to the surface degradation and cavity performance violation. To provide high quality of electron bunches, RF gun cavities operate in electron sources wi…
▽ More
The Pulsed RF Heating (PRFH) is the well known effect in the development of high gradient accelerating cavities. There is a lot of research dedicated to the tolerable strength of electromagnetic field and the corresponding temperature rise leading to the surface degradation and cavity performance violation. To provide high quality of electron bunches, RF gun cavities operate in electron sources with high electric, and hence, magnetic RF fields. Being at the safe side with respect to cavity surface degradation, related to the PRFH result for S band in essentially transient thermal deformations, leading to the cavity frequency shift and quality factor change even within a few microseconds in the RF pulse. Thermo-elastic deformations consist of slow heat propagation from the cavity surface and fast elastic wave propagation from the very thin heated surface layer inside the cavity body with different in five orders typical velocities. For simulations of PRFH effects for more or less practical cavity design we can get results only in direct numerical simulations with certified software like ANSYS. The critical issue for such direct simulations is to combine in a single model the possibility of correct description for such qualitatively different process and to prove the reasonable precision of simulations. This report describes the procedure for simulation of PRFH related transient thermo-elastic deformations in S band cavities. The results of test simulations are presented to show the relative precision of simulations.
△ Less
Submitted 26 December, 2018;
originally announced December 2018.
-
PERLE: Powerful Energy Recovery Linac for Experiments - Conceptual Design Report
Authors:
D. Angal-Kalinin,
G. Arduini,
B. Auchmann,
J. Bernauer,
A. Bogacz,
F. Bordry,
S. Bousson,
C. Bracco,
O. Brüning,
R. Calaga,
K. Cassou,
V. Chetvertkova,
E. Cormier,
E. Daly,
D. Douglas,
K. Dupraz,
B. Goddard,
J. Henry,
A. Hutton,
E. Jensen,
W. Kaabi,
M. Klein,
P. Kostka,
F. Marhauser,
A. Martens
, et al. (17 additional authors not shown)
Abstract:
A conceptual design is presented of a novel ERL facility for the development and application of the energy recovery technique to linear electron accelerators in the multi-turn, large current and large energy regime. The main characteristics of the powerful energy recovery linac experiment facility (PERLE) are derived from the design of the Large Hadron electron Collider, an electron beam upgrade u…
▽ More
A conceptual design is presented of a novel ERL facility for the development and application of the energy recovery technique to linear electron accelerators in the multi-turn, large current and large energy regime. The main characteristics of the powerful energy recovery linac experiment facility (PERLE) are derived from the design of the Large Hadron electron Collider, an electron beam upgrade under study for the LHC, for which it would be the key demonstrator. PERLE is thus projected as a facility to investigate efficient, high current (> 10 mA) ERL operation with three re-circulation passages through newly designed SCRF cavities, at 801.58 MHz frequency, and following deceleration over another three re-circulations. In its fully equipped configuration, PERLE provides an electron beam of approximately 1 GeV energy. A physics programme possibly associated with PERLE is sketched, consisting of high precision elastic electron-proton scattering experiments, as well as photo-nuclear reactions of unprecedented intensities with up to 30 MeV photon beam energy as may be obtained using Fabry-Perot cavities. The facility has further applications as a general technology test bed that can investigate and validate novel superconducting magnets (beam induced quench tests) and superconducting RF structures (structure tests with high current beams, beam loading and transients). Besides a chapter on operation aspects, the report contains detailed considerations on the choices for the SCRF structure, optics and lattice design, solutions for arc magnets, source and injector and on further essential components. A suitable configuration derived from the here presented design concept may next be moved forward to a technical design and possibly be built by an international collaboration which is being established.
△ Less
Submitted 24 May, 2017;
originally announced May 2017.
-
A plasma wakefield acceleration experiment using CLARA beam
Authors:
G. Xia,
D. Angal-Kalinin,
J. Clarke,
J. Smith,
E. Cormier-Michel,
J. Jones,
P. H. Williams,
J. W. Mckenzie,
B. L. Militsyn,
K. Hanahoe,
O. Mete,
A. Aimidula,
C. P. Welsch
Abstract:
We propose a Plasma Accelerator Research Station (PARS) based at proposed FEL test facility CLARA (Compact Linear Accelerator for Research and Applications) at Daresbury Laboratory. The idea is to use the relativistic electron beam from CLARA, to investigate some key issues in electron beam transport and in electron beam driven plasma wakefield acceleration, e.g. high gradient plasma wakefield exc…
▽ More
We propose a Plasma Accelerator Research Station (PARS) based at proposed FEL test facility CLARA (Compact Linear Accelerator for Research and Applications) at Daresbury Laboratory. The idea is to use the relativistic electron beam from CLARA, to investigate some key issues in electron beam transport and in electron beam driven plasma wakefield acceleration, e.g. high gradient plasma wakefield excitation driven by a relativistic electron bunch, two bunch experiment for CLARA beam energy doubling, high transformer ratio, long bunch self-modulation and some other advanced beam dynamics issues. This paper presents the feasibility studies of electron beam transport to meet the requirements for beam driven wakefield acceleration and presents the plasma wakefield simulation results based on CLARA beam parameters. Other possible experiments which can be conducted at the PARS beam line are also discussed.
△ Less
Submitted 24 April, 2014;
originally announced April 2014.
-
Proton-driven plasma wakefield acceleration: a path to the future of high-energy particle physics
Authors:
AWAKE Collaboration,
R. Assmann,
R. Bingham,
T. Bohl,
C. Bracco,
B. Buttenschon,
A. Butterworth,
A. Caldwell,
S. Chattopadhyay,
S. Cipiccia,
E. Feldbaumer,
R. A. Fonseca,
B. Goddard,
M. Gross,
O. Grulke,
E. Gschwendtner,
J. Holloway,
C. Huang,
D. Jaroszynski,
S. Jolly,
P. Kempkes,
N. Lopes,
K. Lotov,
J. Machacek,
S. R. Mandry
, et al. (25 additional authors not shown)
Abstract:
New acceleration technology is mandatory for the future elucidation of fundamental particles and their interactions. A promising approach is to exploit the properties of plasmas. Past research has focused on creating large-amplitude plasma waves by injecting an intense laser pulse or an electron bunch into the plasma. However, the maximum energy gain of electrons accelerated in a single plasma sta…
▽ More
New acceleration technology is mandatory for the future elucidation of fundamental particles and their interactions. A promising approach is to exploit the properties of plasmas. Past research has focused on creating large-amplitude plasma waves by injecting an intense laser pulse or an electron bunch into the plasma. However, the maximum energy gain of electrons accelerated in a single plasma stage is limited by the energy of the driver. Proton bunches are the most promising drivers of wakefields to accelerate electrons to the TeV energy scale in a single stage. An experimental program at CERN -- the AWAKE experiment -- has been launched to study in detail the important physical processes and to demonstrate the power of proton-driven plasma wakefield acceleration. Here we review the physical principles and some experimental considerations for a future proton-driven plasma wakefield accelerator.
△ Less
Submitted 2 April, 2014; v1 submitted 20 January, 2014;
originally announced January 2014.
-
Electron Sources for Future Lightsources, Summary and Conclusions for the Activities during FLS 2012
Authors:
Thorsten Kamps,
Carlos Hernandez-Garcia,
Chase Boulware,
John Corlett,
Katherine Harkay,
Fay Hannon,
Mikhail Krasilnikov,
Boris Militsyn,
Torsten Quast,
Fernando Sannibale,
Jochen Teichert
Abstract:
This paper summarizes the discussions, presentations, and activity of the Future Light Sources Workshop 2012 (FLS 2012) working group dedicated to Electron Sources. The focus of the working group was to discuss concepts and technologies that might enable much higher peak and average brightness from electron beam sources. Furthermore the working group was asked to consider methods to greatly improv…
▽ More
This paper summarizes the discussions, presentations, and activity of the Future Light Sources Workshop 2012 (FLS 2012) working group dedicated to Electron Sources. The focus of the working group was to discuss concepts and technologies that might enable much higher peak and average brightness from electron beam sources. Furthermore the working group was asked to consider methods to greatly improve the robustness of operation and lower the costs of providing electrons.
△ Less
Submitted 26 July, 2013; v1 submitted 5 July, 2013;
originally announced July 2013.
-
Gallium Arsenide preparation and QE Lifetime Studies using the ALICE Photocathode Preparation Facility
Authors:
N. Chanlek,
R. M. Jones,
J. D. Herbert,
L. B. Jones,
K. J. Middleman,
B. L. Militsyn
Abstract:
In recent years, Gallium Arsenide (GaAs) type photocathodes have become widely used as electron sources in modern Energy Recovery Linac based light sources such as the Accelerators and Lasers in Combined Experiments (ALICE) at Daresbury Laboratory and as polarised electron source for the proposed International Linear Collider (ILC). Once activated to a Low Electron Affinity (LEA) state and illumin…
▽ More
In recent years, Gallium Arsenide (GaAs) type photocathodes have become widely used as electron sources in modern Energy Recovery Linac based light sources such as the Accelerators and Lasers in Combined Experiments (ALICE) at Daresbury Laboratory and as polarised electron source for the proposed International Linear Collider (ILC). Once activated to a Low Electron Affinity (LEA) state and illuminated by a laser, these materials can be used as a high-brightness source of both polarised and un-polarised electrons. This paper presents an effective multi-stage preparation procedure including heat cleaning, atomic hydrogen cleaning and the activation process for a GaAs photocathode. The stability of quantum efficiency (QE) and lifetime of activated to LEA state GaAs photocathode have been studied in the ALICE load-lock photocathode preparation facility which has a base pressure in the order of 10^-11 mbar. These studies are supported by further experimental evidence from surface science techniques such as X-ray Photoelectron Spectroscopy (XPS) to demonstrate the processes at the atomic level.
△ Less
Submitted 1 June, 2010;
originally announced June 2010.
-
Spin-Momentum Correlations in Quasi-Elastic Electron Scattering from Deuterium
Authors:
I. Passchier,
L. D. van Buuren,
D. Szczerba,
R. Alarcon,
Th. S. Bauer,
D. Boersma,
J. F. J. van den Brand,
H. J. Bulten,
R. Ent,
M. Ferro-Luzzi,
M. Harvey,
P. Heimberg,
D. W. Higinbotham,
S. Klous,
H. Kolster,
J. Lang,
B. L. Militsyn,
D. Nikolenko,
G. J. L. Nooren,
B. E. Norum,
H. R. Poolman,
I. Rachek,
M. C. Simani,
E. Six,
H. de Vries
, et al. (2 additional authors not shown)
Abstract:
We report on a measurement of spin-momentum correlations in quasi-elastic scattering of longitudinally polarized electrons with an energy of 720 MeV from vector-polarized deuterium. The spin correlation parameter $A^V_{ed}$ was measured for the $^2 \vec{\rm H}(\vec e,e^\prime p)n$ reaction for missing momenta up to 350 MeV/$c$ at a four-momentum transfer squared of 0.21 (GeV/c)$^2$. The data giv…
▽ More
We report on a measurement of spin-momentum correlations in quasi-elastic scattering of longitudinally polarized electrons with an energy of 720 MeV from vector-polarized deuterium. The spin correlation parameter $A^V_{ed}$ was measured for the $^2 \vec{\rm H}(\vec e,e^\prime p)n$ reaction for missing momenta up to 350 MeV/$c$ at a four-momentum transfer squared of 0.21 (GeV/c)$^2$. The data give detailed information about the spin structure of the deuteron, and are in good agreement with the predictions of microscopic calculations based on realistic nucleon-nucleon potentials and including various spin-dependent reaction mechanism effects. The experiment demonstrates in a most direct manner the effects of the D-state in the deuteron ground-state wave function and shows the importance of isobar configurations for this reaction.
△ Less
Submitted 21 September, 2001;
originally announced September 2001.
-
The Charge Form Factor of the Neutron from the Reaction \pol{2H}(\pol{e},e'n)p
Authors:
I. Passchier,
R. Alarcon,
Th. S. Bauer,
D. Boersma,
J. F. J. van den Brand,
L. D. van Buuren,
H. J. Bulten,
M. Ferro-Luzzi,
P. Heimberg,
D. W. Higinbotham,
C. W. de Jager,
S. Klous,
H. Kolster,
J. Lang,
B. L. Militsyn,
D. Nikolenko,
G. J. L. Nooren,
B. E. Norum,
H. R. Poolman,
I. Rachek,
M. C. Simani,
E. Six,
D. Szczerba,
H. de Vries,
K. Wang
Abstract:
We report on the first measurement of spin-correlation parameters in quasifree electron scattering from vector-polarized deuterium. Polarized electrons were injected into an electron storage ring at a beam energy of 720~MeV. A Siberian snake was employed to preserve longitudinal polarization at the interaction point. Vector-polarized deuterium was produced by an atomic beam source and injected i…
▽ More
We report on the first measurement of spin-correlation parameters in quasifree electron scattering from vector-polarized deuterium. Polarized electrons were injected into an electron storage ring at a beam energy of 720~MeV. A Siberian snake was employed to preserve longitudinal polarization at the interaction point. Vector-polarized deuterium was produced by an atomic beam source and injected into an open-ended cylindrical cell, internal to the electron storage ring. The spin correlation parameter A^V_{ed} was measured for the reaction \pol{2H}(\pol{e},e'n)p at a four-momentum transfer squared of 0.21 (GeV/c)^2 from which a value for the charge form factor of the neutron was extracted.
△ Less
Submitted 19 July, 1999;
originally announced July 1999.