-
Absolute frequency measurement of molecular iodine hyperfine transitions at 554 nm and its application to stabilize a 369 nm laser for Yb+ ions cooling
Authors:
Y. T. Chen,
N. C. Xin,
H. R. Qin,
S. N. Miao,
Y. Zheng,
J. W. Zhang,
L. J. Wang
Abstract:
We investigate 13 hyperfine structures of transition lines of 127I2 near 554 nm, namely, the R(50) 22-0, P(46) 22-0, P(121) 24-0, P(69) 25-1, R(146) 25-0, R(147) 28-1, P(160) 26-0, P(102) 26-1, R(96) 23-0, R(49) 22-0, P(45) 22-0, P(92) 23-0, and R(72) 25-1 transitions, and measure their absolute frequencies with an optical frequency comb. A 369 nm frequency-tripled laser is frequency stabilized by…
▽ More
We investigate 13 hyperfine structures of transition lines of 127I2 near 554 nm, namely, the R(50) 22-0, P(46) 22-0, P(121) 24-0, P(69) 25-1, R(146) 25-0, R(147) 28-1, P(160) 26-0, P(102) 26-1, R(96) 23-0, R(49) 22-0, P(45) 22-0, P(92) 23-0, and R(72) 25-1 transitions, and measure their absolute frequencies with an optical frequency comb. A 369 nm frequency-tripled laser is frequency stabilized by locking the 554 nm harmonic-frequency laser to the R(146) 25-0 a15 line of 127I2 via modulation transfer spectroscopy. A frequency stability of 5E-12 is observed over a 1000 s integration time. The measurement of the molecular iodine spectroscopy at 554 nm enriches high-precision experimental data, and also enables theoretical predictions. Meanwhile, the 369 nm frequency-tripled laser stabilized by molecular iodine spectroscopy has wide applications in frequency metrology, and quantum information processing based on Yb+ ions.
△ Less
Submitted 11 September, 2023;
originally announced September 2023.
-
$^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ sympathetic-cooling bi-species Coulomb crystal applied to microwave frequency standard
Authors:
Y Zheng,
H. R. Qin,
S. N. Miao,
N. C. Xin,
Y. T. Chen,
J. Z. Han,
J. W. Zhang,
L. J. Wang
Abstract:
We reported the realization of a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ bi-species Coulomb crystal comprising $^{174}\mathrm{Yb}^+$ ions as coolant and verified its potential for application as a $^{113}\mathrm{Cd}^+$ microwave frequency standard employing sympathetic cooling.The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The…
▽ More
We reported the realization of a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ bi-species Coulomb crystal comprising $^{174}\mathrm{Yb}^+$ ions as coolant and verified its potential for application as a $^{113}\mathrm{Cd}^+$ microwave frequency standard employing sympathetic cooling.The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The $^{113}\mathrm{Cd}^+$ ions are trapped in the center, which reduces considerably RF heating and excess micromotion to which the $^{113}\mathrm{Cd}^+$ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to $5\times10^{-16}$, which represents an order of magnitude improvement over sympathetic cooled $^{40}\mathrm{Ca}^+$-$^{113}\mathrm{Cd}^+$ crystal. The uncertainty from the second-order Zeeman effect, which contributes the largest uncertainty to the microwave-ion frequency standard, is reduced to $4\times10^{-16}$. The relevant AC Stark shift uncertainty is estimated to be $4\times10^{-19}$. These results indicate using $^{174}\mathrm{Yb}^+$ as coolant ions for $^{113}\mathrm{Cd}^+$ is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ two-component crystal.
△ Less
Submitted 4 July, 2023;
originally announced July 2023.
-
Second-order Doppler frequency shifts of trapped ions in a linear Paul trap
Authors:
S. N. Miao,
J. W. Zhang,
Y. Zheng,
H. R. Qin,
N. C. Xin,
Y. T. Chen,
J. Z. Han,
L. J. Wang
Abstract:
The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS. Based on the hypothesis that the ion density is un…
▽ More
The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS. Based on the hypothesis that the ion density is uniformly distributed in the radial direction, we propose a new model to accurately evaluate the total SODFS for ion microwave clocks. The effectiveness of the model has been verified both in simulation and experiment, especially for ion ensemble with temperature less than 100 mK. We believe that our new model offers advantages in accurately evaluating the SODFS for the ion trap, especially those of laser-cooled ion microwave clocks based on large ion clouds.
△ Less
Submitted 16 June, 2022;
originally announced June 2022.
-
Determination of hyperfine splittings and Landé $g_J$ factors of $5s~^2S_{1/2}$ and $5p~^2P_{1/2,3/2}$ states of $^{111,113}$Cd$^+$ for a microwave frequency standard
Authors:
J. Z. Han,
R. Si,
H. R. Qin,
N. C. Xin,
Y. T. Chen,
S. N. Miao,
C. Y. Chen,
J. W. Zhang,
L. J. Wang
Abstract:
Regarding trapped-ion microwave-frequency standards, we report on the determination of hyperfine splittings and Landé $g_J$ factors of $^{111,113}$Cd$^+$. The hyperfine splittings of the $5p~^2P_{3/2}$ state of $^{111,113}$Cd$^+$ ions were measured using laser-induced fluorescence spectroscopy. The Cd$^+$ ions were confined in a linear Paul trap and sympathetically cooled by Ca$^+$ ions. Furthermo…
▽ More
Regarding trapped-ion microwave-frequency standards, we report on the determination of hyperfine splittings and Landé $g_J$ factors of $^{111,113}$Cd$^+$. The hyperfine splittings of the $5p~^2P_{3/2}$ state of $^{111,113}$Cd$^+$ ions were measured using laser-induced fluorescence spectroscopy. The Cd$^+$ ions were confined in a linear Paul trap and sympathetically cooled by Ca$^+$ ions. Furthermore, the hyperfine splittings and Landé $g_J$ factors of the $5s~^2S_{1/2}$ and $5p~^2P_{1/2,3/2}$ levels of $^{111,113}$Cd$^+$ were calculated with greater accuracy using the multiconfiguration Dirac--Hartree--Fock scheme. The measured hyperfine splittings and the Dirac--Hartree--Fock calculation values were cross-checked, thereby further guaranteeing the reliability of our results. The results provided in this work can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, and subsequently the stability and accuracy of the microwave frequency standard based on trapped Cd$^+$ ions.
△ Less
Submitted 17 January, 2022;
originally announced January 2022.
-
Sympathetic cooling of a large ${}^{113}\mathrm{Cd}^{+}$ ion crystal with ${}^{40}\mathrm{Ca}^{+}$ in a linear Paul trap
Authors:
S. N. Miao,
H. R. Qin,
N. C. Xin,
Y. T. Chen,
J. W. Zhang,
L. J. Wang
Abstract:
We have sympathetically cooled and crystallized ${}^{113}\mathrm{Cd}^{+}$ ions with laser-cooled ${}^{40}\mathrm{Ca}^{+}$ ions, and directly observed the complete large bicrystal structure in a linear Paul trap. The large two-component crystal contains up to $3.5\times10^3$ ${}^{40}\mathrm{Ca}^{+}$ ions and $6.8\times10^3$ ${}^{113}\mathrm{Cd}^{+}$ ions. The temperature of the crystallized…
▽ More
We have sympathetically cooled and crystallized ${}^{113}\mathrm{Cd}^{+}$ ions with laser-cooled ${}^{40}\mathrm{Ca}^{+}$ ions, and directly observed the complete large bicrystal structure in a linear Paul trap. The large two-component crystal contains up to $3.5\times10^3$ ${}^{40}\mathrm{Ca}^{+}$ ions and $6.8\times10^3$ ${}^{113}\mathrm{Cd}^{+}$ ions. The temperature of the crystallized ${}^{113}\mathrm{Cd}^{+}$ ions was measured to be as low as 41 mK with a large mass ratio. Moreover, we have studied several properties and structures of the ultracold sample. The factors affecting the sympathetic cooling effect were studied, including the electrical parameters and the number ratio between laser-cooled ions and sympathetically-cooled ions. The results of this paper enrich the experimental research of large two-component ion crystals, and the ultracold sample of ${}^{113}\mathrm{Cd}^{+}$ ions makes it possible to further improve the accuracy of the cadmium-ion microwave frequency standard.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Progress toward a microwave frequency standard based on laser-cooled large scale 171Yb+ ion crystal
Authors:
N. C. Xin,
H. R. Qin,
S. N. Miao,
Y. T. Chen,
J. Z. Han,
J. W. Zhang,
L. J. Wang
Abstract:
We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was f…
▽ More
We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to $8.5 \times {10^{ - 13}}/\sqrt τ$ for averaging times between 10 and 1000 s.
△ Less
Submitted 9 January, 2022;
originally announced January 2022.
-
Precision determination of the ground-state hyperfine splitting of trapped ${}^{113}$Cd${}^{+}$ ions
Authors:
S. N. Miao,
J. W. Zhang,
H. R. Qin,
N. C. Xin,
J. Z. Han,
L. J. Wang
Abstract:
We measured the ground-state hyperfine splitting of trapped ${}^{113}$Cd${}^{+}$ ions to be 15199862855.02799(27) Hz with a fractional uncertainty of $1.8\times10^{-14}$. The ions were trapped and laser-cooled in a linear quadrupole Paul trap. The fractional frequency stability was measured to be ${4.2} \times 10^{-13}/\sqrtτ $, obtained from Ramsey fringes of high signal-to-noise ratio and taken…
▽ More
We measured the ground-state hyperfine splitting of trapped ${}^{113}$Cd${}^{+}$ ions to be 15199862855.02799(27) Hz with a fractional uncertainty of $1.8\times10^{-14}$. The ions were trapped and laser-cooled in a linear quadrupole Paul trap. The fractional frequency stability was measured to be ${4.2} \times 10^{-13}/\sqrtτ $, obtained from Ramsey fringes of high signal-to-noise ratio and taken over a measurement time of nearly 5 hours, which is close to the short-term stability limit estimated from the Dick effect. Our result is consistent with previous reported values, but the measurement precision is four times better than the best result obtained to date.
△ Less
Submitted 24 October, 2021;
originally announced October 2021.