A quantitative assessment of Imaging High-Z and Medium-Z materials using Muon Scattering Tomography
Authors:
A. F. Alrheli,
D. Barker,
C. De Sio,
D. Kikoła,
A. K. Kopp,
M. Mhaidra,
J. P. Stowell,
L. F. Thompson,
J. J. Velthuis,
M. J. Weekes
Abstract:
Muon Scattering Tomography (MST) has been shown to be a powerful technique for the non-invasive imaging of high-shielded objects. We present here the application of the MST technique to investigate two types of nuclear waste packages, a small-steel drum and a large nuclear waste cask, namely, a CASTOR V/52. We have developed a quantitative method using the contrast-to-noise ratio (CNR) to evaluate…
▽ More
Muon Scattering Tomography (MST) has been shown to be a powerful technique for the non-invasive imaging of high-shielded objects. We present here the application of the MST technique to investigate two types of nuclear waste packages, a small-steel drum and a large nuclear waste cask, namely, a CASTOR V/52. We have developed a quantitative method using the contrast-to-noise ratio (CNR) to evaluate the performance of an MST detector system in differentiating between high-, medium-, and low-Z materials inside nuclear waste packages with different shielding types. This study reveals that our MST detector system is able to differentiate between a (10 $\times$ 10 $\times$ 10 cm$^3$) uranium cube, embedded within a concrete matrix inside the small-steel drum, and regions of background signal in six hours of muon exposure time with a CNR value of 3.1$\pm$0.2. During our investigation of the highly-shielded cask, the reconstructed images of the cask contents indicated the ability of our system to detect irregular baskets, such as empty baskets, with a CNR value of 5.0$\pm$0.3 after 30 days of muon exposure. These studies were done using a Monte Carlo simulation tuned to the performance of resistive plate chambers (RPCs) based muon tomography system built by the University of Bristol, which had a reported position resolution of 350 micron.
Here we also report the dependence of the performance on the position resolution. We argue that using a combination of RPC and drift chambers (DC) detectors with 700 micron and 4 mm position resolutions respectively is able to generate tomographic images of well-shielded materials in a few hours of muon exposure time. With these position resolutions, our system needs six hours of muon exposure time to produce a good quality image of a cube of uranium with side-length of 10 cm shielded by a concrete matrix with CNR value of 2.4$\pm$0.25.
△ Less
Submitted 12 May, 2022; v1 submitted 5 January, 2022;
originally announced January 2022.
Material Identification in Nuclear Waste Drums using Muon Scattering Tomography and Multivariate Analysis
Authors:
M. J. Weekes,
A. F. Alrheli,
D. Barker,
D. Kikoła,
A. K. Kopp,
M. Mhaidra,
J. P. Stowell,
L. F. Thompson,
J. J. Velthuis
Abstract:
The use of muon scattering tomography for the non-invasive characterisation of nuclear waste is well established. We report here on the application of a combination of feature discriminators and multivariate analysis techniques to locate and identify materials in nuclear waste drums. After successful training and optimisation of the algorithms they are then tested on a range of material configurat…
▽ More
The use of muon scattering tomography for the non-invasive characterisation of nuclear waste is well established. We report here on the application of a combination of feature discriminators and multivariate analysis techniques to locate and identify materials in nuclear waste drums. After successful training and optimisation of the algorithms they are then tested on a range of material configurations to assess the system's performance and limitations. The system is able to correctly identify uranium, iron and lead objects on a ~few \text{cm} scale. The system's sensitivity to small uranium objects is also established as $0.90^{+0.07}_{-0.12}$, with a false positive rate of $0.12^{+0.12}_{-0.07}$.
△ Less
Submitted 24 February, 2021; v1 submitted 24 November, 2020;
originally announced December 2020.