-
Bayesian Estimation of Laser Linewidth from Delayed Self-Heterodyne Measurements
Authors:
Lutz Mertenskötter,
Markus Kantner
Abstract:
We present a statistical inference approach to estimate the frequency noise characteristics of ultra-narrow linewidth lasers from delayed self-heterodyne beat note measurements using Bayesian inference. Particular emphasis is on estimation of the intrinsic (Lorentzian) laser linewidth. The approach is based on a statistical model of the measurement process, taking into account the effects of the i…
▽ More
We present a statistical inference approach to estimate the frequency noise characteristics of ultra-narrow linewidth lasers from delayed self-heterodyne beat note measurements using Bayesian inference. Particular emphasis is on estimation of the intrinsic (Lorentzian) laser linewidth. The approach is based on a statistical model of the measurement process, taking into account the effects of the interferometer as well as the detector noise. Our method therefore yields accurate results even when the intrinsic linewidth plateau is obscured by detector noise. The regression is performed on periodogram data in the frequency domain using a Markov-chain Monte Carlo method. By using explicit knowledge about the statistical distribution of the observed data, the method yields good results already from a single time series and does not rely on averaging over many realizations, since the information in the available data is evaluated very thoroughly. The approach is demonstrated for simulated time series data from a stochastic laser rate equation model with 1/f-type non-Markovian noise.
△ Less
Submitted 18 May, 2023; v1 submitted 12 May, 2023;
originally announced May 2023.
-
Accurate evaluation of self-heterodyne laser linewidth measurements using Wiener filters
Authors:
Markus Kantner,
Lutz Mertenskötter
Abstract:
Self-heterodyne beat note measurements are widely used for the experimental characterization of the frequency noise power spectral density (FN-PSD) and the spectral linewidth of lasers. The measured data, however, must be corrected for the transfer function of the experimental setup in a post-processing routine. The standard approach disregards the detector noise and thereby induces reconstruction…
▽ More
Self-heterodyne beat note measurements are widely used for the experimental characterization of the frequency noise power spectral density (FN-PSD) and the spectral linewidth of lasers. The measured data, however, must be corrected for the transfer function of the experimental setup in a post-processing routine. The standard approach disregards the detector noise and thereby induces reconstruction artifacts, i.e., spurious spikes, in the reconstructed FN-PSD. We introduce an improved post-processing routine based on a parametric Wiener filter that is free from reconstruction artifacts, provided a good estimate of the signal-to-noise ratio is supplied. Building on this potentially exact reconstruction, we develop a new method for intrinsic laser linewidth estimation that is aimed at deliberate suppression of unphysical reconstruction artifacts. Our method yields excellent results even in the presence of strong detector noise, where the intrinsic linewidth plateau is not even visible using the standard method. The approach is demonstrated for simulated time series from a stochastic laser model including 1/f-type noise.
△ Less
Submitted 25 January, 2023;
originally announced January 2023.
-
Entangled Two-Photon Absorption Spectroscopy with Varying Pump Wavelength
Authors:
Lutz Mertenskötter,
Kurt Busch,
Roberto de J. León-Montiel
Abstract:
In virtual-state spectroscopy, information about the energy-level structure of an arbitrary sample is retrieved by Fourier transforming sets of measured two-photon absorption probabilities of entangled photon pairs where the degree of entanglement and the delay time between the photons have been varied. This works well for simple systems but quickly becomes rather difficult when many intermediate…
▽ More
In virtual-state spectroscopy, information about the energy-level structure of an arbitrary sample is retrieved by Fourier transforming sets of measured two-photon absorption probabilities of entangled photon pairs where the degree of entanglement and the delay time between the photons have been varied. This works well for simple systems but quickly becomes rather difficult when many intermediate states are involved. We propose and discuss an extension of entangled two-photon absorption spectroscopy that solves this problem by means of repeated measurements at different pump wavelengths. Specifically, we demonstrate that our extension works well for a variety of realistic experimental setups.
△ Less
Submitted 23 April, 2021;
originally announced April 2021.